• 제목/요약/키워드: Column Height

검색결과 392건 처리시간 0.024초

Seismic behavior of steel reinforced concrete special-shaped column-beam joints

  • Liu, Z.Q.;Xue, J.Y.;Zhao, H.T.
    • Earthquakes and Structures
    • /
    • 제11권4호
    • /
    • pp.665-680
    • /
    • 2016
  • This paper focuses on the study of seismic behavior of steel reinforced concrete special-shaped column-beam joints. Six specimens, which are designed according to the principle of strong-member and weak-joint core, are tested under low cyclic reversed load. Key parameters include the steel form in column section and the ratio of column limb height to thickness. The failure mode, load-displacement curves, ductility, stiffness degradations, energy dissipation capacity and shear deformation of joint core of the test subassemblies are analyzed. The results indicate that SRC special-shaped column-beam joints have good seismic behavior. All specimens failed due to the shear failure of the joint core, and the failure degree between the two sides of joint core is similar for the exterior joint but different for the corner joint. Compared to the joints with channel steel truss, the joints with solid web steel skeleton illustrate better ductility and energy dissipation capacity, but the loading capacity and stiffness are roughly close. With the increasing of the ratio of column limb height to thickness, the joints illustrate higher loading capacity and stiffness, better energy dissipation capacity, but worse ductility.

Effect of cooling rate on the post-fire behavior of CFST column

  • Afaghi-Darabi, Alireza;Abdollahzadeh, Gholamreza
    • Computers and Concrete
    • /
    • 제23권4호
    • /
    • pp.281-294
    • /
    • 2019
  • The post-fire behavior of structural elements and the cooling process has always been one of the main concerns of the structural engineers. The structures can be cooled at different rates, where they affect the structure's behavior. In the present study, a numerical model has been developed using the Abaqus program to investigate the effect of cooling rate on the post-fire behavior of the CFST column. To verify the model, results of an experimental study performed on CFST columns within a full heating and cooling cycle have been used. In this model, coMParison of the residual strength has been employed in order to examine the behavior of CFST column under different cooling rates. Furthermore, a parametric study was carried out on the strength of steel and concrete, the height of the specimens, the axial load ratio and the cross-sectional shape of the specimen through the proposed model. It was observed that the cooling rate affects the behavior of the column after the fire, and thus the higher the specimen's temperature is, the more effect it has on the behavior. It was also noticed that water cooling had slightly more residual strength than natural cooling. Furthermore, it was recognized from the parametric study, that by increasing the strength of steel and concrete and the load ratio, as well as modifying the cross-sectional shape from circular to square, residual strength of column at the cooling phase was less than that of the heating phase. In addition, with reducing column height, no change was witnessed in the column behavior after the cooling phase.

Empirical Correlations for Breakup Length of Liquid Jet in Uniform Cross Flow-A Review

  • No, Soo-Young
    • 한국분무공학회지
    • /
    • 제18권1호
    • /
    • pp.35-43
    • /
    • 2013
  • The empirical correlations for the prediction of breakup length of liquid jet in uniform cross flow are reviewed and classified in this study. The breakup length of liquid jets in cross flow was normally discussed in terms of the distances from the nozzle exit to the column breakup location in the x and y directions, called as column fracture distance and column fracture height, respectively. The empirical correlations for the prediction of column fracture distance can be classified as constant form, momentum flux ratio form, Weber number form and other parameter form, respectively. In addition, the empirical correlations for the prediction of column fracture height can be grouped as momentum flux ratio form, Weber number form and other parameter form, respectively. It can be summarized that the breakup length of liquid jet in a cross flow is a basically function of the liquid to air momentum flux ratio. However, Weber number, liquid-to-air viscosity ratio and density ratio, Reynolds number or Ohnesorge number were incorporated in the empirical correlations depending on the investigators. It is clear that there exist the remarkable discrepancies of predicted values by the existing correlations even though many correlations have the same functional form. The possible reasons for discrepancies can be summarized as the different experimental conditions including jet operating condition and nozzle geometry, measurement and image processing techniques introduced in the experiment, difficulties in defining the breakup location etc. The evaluation of the existing empirical correlations for the prediction of breakup length of liquid jet in a uniform cross flow is required.

고유동 콘크리트를 이용한 콘크리트 충전강관 기둥의 실물대 시공실험 (Full Scale Tests of Concrete Filled Steel Tube Column using High Fluidity Concrete)

  • 김욱종;이도범
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2001년도 학술대회지
    • /
    • pp.222-227
    • /
    • 2001
  • 고층 건축물에 사용할 CFT 기둥에 적합한 고유동 콘크리트를 개발하고, 이를 적용하여 실물대의 Mockup 실험을 진행하여 시공시 문제점 및 관리기술을 확보하고자 하였다. 사전에 재료선정실험을 진행하여 CFT 기둥에 가장 적합한 재료를 선정하고, 시공성을 향상시키기 위하여 2단계에 걸쳐 실험을 진행하였다. 1차 실험에서는 타설방법, 유도관의 유무, 타선속도, 낙하높이 등을 변수로 실험을 진행하여 그중 시공성이 우수하면서 품질관리에 문제가 없는 변수를 대상으로 2차 실험을 진행하였다 2차 실험에서는 $9.6{\cal}m$ 높이의 강관에 타설방법을 달리하여 콘크리트 충전실험을 진행하였다. 실험결과 시공성 향상을 위하여 기존의 시공지침과 차이를 가진 변수에서도 우수한 충전성능을 보임을 확인하였다.

  • PDF

Batch Column에서의 슬러지농도변화에 대한 연구 (Study on Sludge Concentration Change in Batch Column)

  • 박석균;강선홍;김동하
    • 상하수도학회지
    • /
    • 제20권3호
    • /
    • pp.443-450
    • /
    • 2006
  • For understanding sludge concentration profile as a function of time, sludge was sampled at each sampling port. When sludge concentration was 3g/L, the vertical sludge concentration distribution was similar to that of 2g/L of sludge concentration. During the early stage of sludge settling, sludge concentration increased remarkably as the sludge interface height in batch column became lower. The higher sludge concentration became, the worse sludge setteability became. Also, the type of sludge settling was influenced with sludge concentration gradient in batch column. In the same concentration, the greater sludge concentration gradient was, the faster sludge interface settled down. And the changing sludge concentrations in a batch settling or a continuous settling were simulated by using the equation of sludge interface height change model.

Effect of Buffer Composition, Sephadex Grade and Column Size on Filtration Based Quality Improvement of Semen from Murrah Buffalo Bull

  • Maurya, V.P.;Tuli, R.K.;Goyal, R.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제16권2호
    • /
    • pp.165-171
    • /
    • 2003
  • Sixty semen ejaculates collected at weekly interval from four Murrah Buffalo bulls over a period of seven months (Nov.1999 to May 2000) were used in the present study. Three buffer medium (sodium citrate, TES and Tris) were used for soaking of sephadex. Three grades of sephadex (G-15,G-100, and G-200) were used for preparation of columns. Columns of three different height (one, two and three cm) were used for separation of semen. Twenty semen ejaculates were used in each project. In the first experiment each semen ejaculates was divided into four parts. One part was kept as control and other three parts were passed thought one cm column of sephadex G-15 prepared in three different buffers. There was significant (p<0.05) increase in percent progressive sperm motility and percent live spermatozoa and decrease in percent abnormal spermatozoa and percent spermatozoa with damaged acrosome as well as sperm numbers after filtration through all the three columns. Sperm quality obtained in the filtrate of column prepared in Tris buffer was better in comparison to other two buffers. So the Tris buffer was used in the second trial. Twenty semen ejaculates were used in this experiment. Each semen ejaculate was divided into four parts. One part was kept as control (non-filtered) and other three parts were passed through columns of different grade of sephadex (G-15, G-100 and G-200). Progressive sperm motility and live sperm percentage improved significantly while decline in percent abnormal spermatozoa and percent spermatozoa with damaged acrosome and sperm concentration was observed after filtration through all the columns as compared to control (non-filtered) semen. Since post filtration quality of semen was better in the sephadex G-100 column, therefore it was selected for the next experiment. In third experiment, Tris buffer and sephadex G-100 were used for preparing columns of different height (one, two and three cm) and twenty semen ejaculates were filtered. The quality characteristics of semen (percent progressive sperm motility, percent live spermatozoa and sperm concentration) after filtration through one cm column were significantly (p<0.05) higher than after filtration through columns of two and three cm height. However non -significant (p>0.05) difference due to height of columns was observed for percent abnormal and percent damaged acrosome but 1 cm column comparatively gave better result than of 2 and 3 cm column height.

Cyclic behavior of steel beam-concrete wall connections with embedded steel columns (II): Theoretical study

  • Li, Guo-Qiang;Gu, Fulin;Jiang, Jian;Sun, Feifei
    • Steel and Composite Structures
    • /
    • 제23권4호
    • /
    • pp.409-420
    • /
    • 2017
  • This paper theoretically studies the cyclic behavior of hybrid connections between steel coupling beams and concrete shear walls with embedded steel columns. Finite element models of connections with long and short embedded steel columns are built in ABAQUS and validated against the test results in the companion paper. Parametric studies are carried out using the validated FE model to determine the key influencing factors on the load-bearing capacity of connections. A close-form solution of the load-bearing capacity of connections is proposed by considering the contributions from the compressive strength of concrete at the interface between the embedded beam and concrete, shear yielding of column web in the tensile region, and shear capacity of column web and concrete in joint zone. The results show that the bond slip between embedded steel members and concrete should be considered which can be simulated by defining contact boundary conditions. It is found that the loadbearing capacity of connections strongly depends on the section height, flange width and web thickness of the embedded column. The accuracy of the proposed calculation method is validated against test results and also verified against FE results (with differences within 10%). It is recommended that embedded steel columns should be placed along the entire height of shear walls to facilitate construction and enhance the ductility. The thickness and section height of embedded columns should be increased to enhance the load-bearing capacity of connections. The stirrups in the joint zone should be strengthened and embedded columns with very small section height should be avoided.

수피에 의한 중금속 흡착시 경금속의 영향과 중금속간의 흡착 경쟁 (Effect of Light Metal Ions and Competition among Heavy Metal Ions during the Adsorption of Heavy Metal Ions by Bark)

  • 백기현;김동호;최돈하
    • 한국환경농학회지
    • /
    • 제16권2호
    • /
    • pp.115-118
    • /
    • 1997
  • When the light metals such as $Ca^{++}$ and $Mg^{++}$ were added to heavy metal solution, the adsorption of heavy metals was increased by 20 to 30% more, but there were no differences between species. $Pb^{++}$ was the most adsorbed metal(99.5%), and the adsorption ratio of $Cd^{++}$ was significantly improved. In addition, when the light metal concentration was increased to 100ppm, the adsoption ratios of all four heavy metals were reached to 92 to 99%, while coniferous barks showed only 85 to 92%. On the mixture of four heavy metals, the adsorbed amount of each metal was significantly reduced, compared with that of one heavy metal, while $Zn^{++}$ showed the adsorption improvement to 95%. On the column experiment, $Pb^{++}$ was almost completely adsorbed in the upper part of column, and the adsorbed amount of $Cu^{++}$ was gradually decreased depending on column depth. However, $Cd^{++}$ and $Zn^{++}$ were not influenced by column height, and constantly adsorbed on various column height. Based on the above results, each heavy metal had different adsorption mechanism.

  • PDF

Analysis of seismic mid-column pounding between low rise buildings with unequal heights

  • Jiang, Shan;Zhai, Changhai;Zhang, Chunwei;Ning, Ning
    • Earthquakes and Structures
    • /
    • 제15권4호
    • /
    • pp.395-402
    • /
    • 2018
  • Floor location of adjacent buildings may be different in terms of height elevation, and thus, the slab may hit on the columns of adjacent insufficiently separated buildings during severe ground motions. Such impacts, often referred to as mid-column pounding, can be catastrophic. Substantial pounding damage or even total collapse of structures was often observed in large amount of adjacent low rise buildings. The research on the mid-column pounding between low rise buildings is in urgency need. In present study, the responses of two adjacent low rise buildings with unequal heights and different dynamic properties have been analyzed. Parametric studies have also been conducted to assess the influence of story height difference, gap distance and input direction of ground motion on the effect of structural pounding response. Another emphasis of this study is to analyze the near-fault effect, which is important for the structures located in the near-fault area. The analysis results show that collisions exhibit significant influence on the local shear force response of the column suffering impact. Because of asymmetric configuration of systems, the structural seismic behavior is distinct by varying the incident directions of the ground motions. Results also show that near-fault earthquakes induced ground motions can cause more significant effect on the pounding responses.

Seismic behavior of steel tube reinforced concrete bridge columns

  • Tian, Tian;Qiu, Wen-liang;Zhang, Zhe
    • Steel and Composite Structures
    • /
    • 제28권1호
    • /
    • pp.63-71
    • /
    • 2018
  • This paper reports an experimental study that was accomplished to assess the seismic behavior of steel tube reinforced concrete bridge columns (SBCs). The motivation of this study was to verify a supposition that the core steel tube may be terminated at a rational position in the column to minimize the material cost while maintaining the seismic behavior of this composite column. Four SBC specimens were tested under combined constant axial load and cyclic reversed lateral loads. The unique variable in the test matrix was the core steel tube embedment length, which ranged from 1/3 to 3/3 of the column effective height. It is observed that SBCs showed two distinctly different failure patterns, namely brittle shear failure and ductile flexural failure. Tests results indicate that the hysteretic responses of SBCs were susceptible to the core steel tube embedment length. With the increase of this structural parameter, the lateral strength of SBC was progressively improved; the deformability and ductility, however, exhibited a tendency of first increase and then decrease. It is also found that in addition to maintained the rate of stiffness degradation and cumulative energy dissipation basically unchanged, both the ductility and deformability of SBC were significantly improved when the core steel tube was terminated at the mid-height of the column, and these were the most unexpected benefits accompanied with material cost reduction.