• 제목/요약/키워드: Column Fracture

검색결과 172건 처리시간 0.025초

파괴지수분석에 의한 WUF-W 접합부의 연쇄붕괴저항 회전능력평가 (Progressive Collapse-Resistant Rotational Capacity Evaluation of WUF-W Connection by Fracture Index Analysis)

  • 김선웅
    • 한국지진공학회논문집
    • /
    • 제22권6호
    • /
    • pp.353-360
    • /
    • 2018
  • This paper is to investigate the micro-behavior of the double-span beams with WUF-W seismic connection under combined axial tension and moment and to propose the rational rotational capacity of it for progressive collapse-resistant analysis and design addressing the stress and strain transfer mechanism. To this end, the behavior of the double-span beams under the column missing event is first investigated using the advanced nonlinear finite element analysis. The characteristics of fracture indices of double-span beams with WUF-W connection under combined axial tension and flexural moment are addressed and then proposed the rational rotational capacity as the basic datum for the progressive collapse-resistant design and analysis. The distribution of fracture indices related to stress and strain for the double-span beams is investigated based on a material and geometric nonlinear finite element analysis. Furthermore, the micro-behavior for earthquake and progressive collapse is explicitly different.

프로펠러샤프트용 Cross Groove형 등속조인트 케이지 강도해석 (Strength Analysis of Cross Groove Type Constant Velocity Joint Cage for Propeller Shaft)

  • 오병기
    • 한국자동차공학회논문집
    • /
    • 제16권2호
    • /
    • pp.74-79
    • /
    • 2008
  • The fracture strength of cross groove type constant velocity joint is largely determined by the fracture strength of the cage having window-like pockets for retaining the torque transmitting balls. A stress distribution acting on the cage is influenced by rigidities of the rim portion and of the column members, therefore requires a calculation such as FEA. To analyze fracture strength of cage, a 3-D elasto-plastic finite element analysis and a submodeling technique are used to achieve both computational efficiency and accuracy. The results are in reasonably good agreement with experiment.

Cyclic testing of steel column-tree moment connections with various beam splice lengths

  • Lee, Kangmin;Li, Rui;Chen, Liuyi;Oh, Keunyeong;Kim, Kang-Seok
    • Steel and Composite Structures
    • /
    • 제16권2호
    • /
    • pp.221-231
    • /
    • 2014
  • The purpose of this study was to evaluate the cyclic behavior of steel column-tree moment connections used in steel moment resisting frames. These connections are composed of shop-welded stub beam-to-column connection and field bolted beam-to-beam splice. In this study, the effects of beam splice length on the seismic performance of column-tree connections were experimentally investigated. The change of the beam splice location alters the bending moment and shear force at the splice, and this may affect the seismic performance of column-tree connections. Three full-scale test specimens of column-tree connections with the splice lengths of 900 mm, 1,100 mm, and 1,300 mm were fabricated and tested. The splice lengths were roughly 1/6, 1/7, 1/8 of the beam span length of 7,500 mm, respectively. The test results showed that all the specimens successfully developed ductile behavior without brittle fracture until 5% radians story drift angle. The maximum moment resisting capacity of the specimens showed little differences. The specimen with the splice length of 1,300 mm showed better bolt slip resistance than the other specimens due to the smallest bending moment at the beam splice.

이축 하중을 받는 이주형 철근콘크리트 교각의 손상도평가 (Damage Assessment of RC Column-Bent Pier under Bidirection Loading)

  • 박창규;이범기;윤상철;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.203-206
    • /
    • 2005
  • Reinforced concrete(RC) column-bent piers represent one of the popular piers used in highway bridges of Korea. Seismic performance of RC column-bent piers under bi-directional seismic loadings was experimentally investigated. Six column bent piers were constructed with two circular supporting columns which were made in 400 mm diameter and 2,000 mm height. Test parameters are different transverse reinforcement ratio and loading pattern. Three specimens were loaded with bi-directional lateral forces which were main cyclic loads in the longitudinal direction and sub-cyclic loads in the transverse direction. Other three specimens were loaded in the opposite way. Test results indicated that lateral strength and ductility of the latter specimens were bigger than those of the former specimens. Plastic hinge was formed with the spall of cover concrete and the fracture of the longitudinal reinforcing steels in the bottom part of two supporting columns for the former three specimens. Similar behavior was observed in the top and bottom parts of two supporting columns for the latter three specimens.

  • PDF

2주형 철근콘크리트 원형 교각의 내진 성능 (Seismic Performance Of RC Two Column-Bent Piers)

  • 정영수;박창규;이범기;이대형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.1-4
    • /
    • 2004
  • RC column bent piers represent one of the most popular piers used in highway bridges. Seismic performance of reinforced concrete (RC) column-bent piers under bidirectional seismic loadings was experimentally investigated. Six column bent piers were constructed with two circular supporting columns. Test parameters are different transverse reinforcement and loading pattern. Three specimens were loaded with bidirectional lateral forces which were main cyclic loads in the longitudinal direction and subcyclic loads in the transverse direction. Other three specimens were loaded in the opposite way. Test results indicated that lateral strength and ductility of the latter specimens were bigger than those of the former specimens. Plastic hinge was formed with the spall of cover concrete and the fracture of the longitudinal reinforcing steels in the bottom part of two supporting columns for the former three specimens. Similar behavior was observed in the top and bottom parts of two supporting columns for the latter three specimens.

  • PDF

Experimental study of beam-column connections with web opening in a low-rise steel frame

  • Wang, Xiuli;Yin, Zhanzhong;Li, Qingfu;Shen, Shizhao
    • Structural Engineering and Mechanics
    • /
    • 제26권3호
    • /
    • pp.263-276
    • /
    • 2007
  • Steel frame structures have been widely used in multi-storey and high-rise buildings and the connections in these structures are critical. In the Northridge and Kobe Earthquake, beam-column connections suffered damage due to brittle fracture. According to seismic design codes, ductility of the beam to column connection is also necessary. A study on the behavior of a beam to column connection with the aim of improving ductility as well as preventing brittle failure was carried out. In order to control the position of a plastic hinge on the beam, a connection with a hole in the beam web was developed. Five specimens with different parameters under cyclic load were assessed. The results are presented in terms of the stress distribution of the beam, hysteretic behavior, and ultimate capacity. Furthermore, the finite element method was also used to analyze the model, and the results were compared with those obtained from the experiment. It is shown from the analysis and experimental results that this type of connection is effective in terms of improving ductility for a beam to column connection in low-rise buildings.

골다공증성 흉요추부 압박 골절에서의 보존적 치료 (Conservative treatment of Osteoporotic Compression Fractures in Thoracolumbar spine)

  • 강규복;고영도
    • Journal of Trauma and Injury
    • /
    • 제18권2호
    • /
    • pp.107-111
    • /
    • 2005
  • Backgrounds: To evaluate the effectiveness of conservative treatment in osteoporotic thoraco-lumbar compression fractures and to identify the factors influencing the progression of compression. Materials and Methods: From January 2003 to October 2004, Patients who were admitted to our hospital for osteoporotic thoraco-lumbar compression fractures were reviewed retrospectively with follow-up more than 12 months (ave. 14.6 months). With simple x-ray lateral view, we evaluate wedge compression ratio (WCR) and kyphotic angle (KA) at initial and final follow-up. We separate the patients into two groups baesed on the amount of progression of vertebral compression and evaluate a relation with BMD, vertebral fracture level, initial WCR, initial KA. All datas were statistically analyzed. Results: An average of T-score was -3.5 and the changes of KA between initial and final follow-up were average $3.5^{\circ}$. Compression of anterior column were progressed to 8.5%. The changes between initial and final WCR in Group I (N=24) was 17.8%, and Group II (N=18) was 3.3%. T-score in group I was -3.4 and group II was -3.8 (p=0.228). vertebral fracture level were 10 T12, 12 L1, 2 L2 in group I; 6 T12, 6 L1, 6 L2 in group II (p=0.156). Initail WCR was 0.74 in group I, 0.63 in group II, and there was statistical difference between two groups(p=0002). Initial kyphotic angle was $13.9^{\circ}$in group I, $16.2^{\circ}$in group II repectively (p=0.392). Conclusion: The conservative treatment with short-term bed rest and early embulation is effective and valuable method to patients who have osteoporotic thoraco-lumbar compression fractures. There was no statistical difference between two groups according to BMD, vertebral fracture level, KA. But in comparison with initail WCR between two groups, there was statistical difference. That means, in the case of small initial compression of anterior column, the progression of compression was bigger than else. In these patients, more strict use of appropriate brace and careful follow-up should be needed.

Crack effect on the elastic buckling behavior of axially and eccentrically loaded columns

  • Zhou, L.;Huang, Y.
    • Structural Engineering and Mechanics
    • /
    • 제22권2호
    • /
    • pp.169-184
    • /
    • 2006
  • A close form solution of the maximum deflection for cracked columns with rectangular cross-sections was developed and thus the elastic buckling behavior and ultimate bearing capacity were studied analytically. First, taking into account the effect of the crack in the potential energy of elastic systems, a trigonometric series solution for the elastic deflection equation of an arbitrary crack position was derived by use of the Rayleigh-Ritz energy method and an analytical expression of the maximum deflection was obtained. By comparison with the rotational spring model (Okamura et al. 1969) and the equivalent stiffness method (Sinha et al. 2002), the advantages of the present solution are that there are few assumed conditions and the effect of axial compression on crack closure was considered. Second, based on the above solutions, the equilibrium paths of the elastic buckling were analytically described for cracked columns subjected to both axial and eccentric compressive load. Finally, as examples, the influence of crack depth, load eccentricity and column slenderness on the elastic buckling behavior was investigated in the case of a rectangular column with a single-edge crack. The relationship of the load capacity of the column with respect to crack depth and eccentricity or slenderness was also illustrated. The analytical and numerical results from the examples show that there are three kinds of collapse mechanisms for the various states of cracking, eccentricity and slenderness. These are the bifurcation for axial compression, the limit point instability for the condition of the deeper crack and lighter eccentricity and the fracture for higher eccentricity. As a result, the conception of critical transition eccentricity $(e/h)_c$, from limit-point buckling to fracture failure, was proposed and the critical values of $(e/h)_c$ were numerically determined for various eccentricities, crack depths and slenderness.

Welded Flange-Bolted Web 강접합부의 파괴모드 추정을 위한 유한요소해석 (Finite Element Analysis for the Failure Mode of Welded Flange-Bolted Web Connection)

  • 조창빈
    • 한국지진공학회논문집
    • /
    • 제3권4호
    • /
    • pp.33-46
    • /
    • 1999
  • 캘리포니아의 강구조 모멘트프레임은 1994년 노스리지 지진시 6.8의 규모와 진앙지에서 근접한 지리적인 악조건에도 불구하고 붕괴나 인명피해 없이 잘 견뎌냈다. 그러나 이후 시행된 조사에서 경제적으로 지진시 안전하다고 믿어져 널리 쓰인 welded flange-bolted web(WFBW) 강접합부(moment connection)의 기둥과 용접의 경계면에서 취성 파괴가 다수 발견되었다. 이논문은 선형파괴역학과 노스리지진이후의 WFBW 강접합부 실험을 이용하여 WFBW 강접합부와 노스리지지진이후 기존 강접합부의 대안으로 추천되고 있는 reduced beam section (RBS) 강접합부의 취성 파괴강도를 결정하는 수치적인 방법을 제안하고 이를 이용하여 이들 강접합부의 취성 파괴모드를 추정하였다.

  • PDF

확대단면에서 폐쇄형 외부 띠철근 배근 방법에 따른 보강기둥의 중심축하중 거동 평가 (Evaluation of Axial Behavior of Strengthened Columns according to Different Peripheral Closed Hoops in Jacket Section)

  • 황용하;양근혁;심재일;최용수
    • 대한건축학회논문집:구조계
    • /
    • 제35권7호
    • /
    • pp.139-146
    • /
    • 2019
  • This study examined the effect of various arrangement methods for forming peripheral closed hoops in the jacket section on the axial behavior of section enlargement strengthening columns. Four types of peripheral closed hoops arranged in the jacket section were prepared as follows: 1) Closed connection of prefabricated bar units (column P); 2) V-clip installation across the overlapped legs of channel-type bars (column V); 3) Use of glass fiber mesh for an alternative of steel bars (column F); and 4) combination of prefabricated bar units and glass fiber mesh (column PF). The V-clip is designed to form the closed hoops in the jacket section using the overlapped channel-type bars, preventing the opening of the channel bar legs. The glass fiber mesh is to examine the feasibility to apply for closed hoops in the jacket section as an alternative for steel bars, considering the easy construction. In the jacket section of all the strengthened columns, V-ties were arranged for supplementary ties, avoiding the interruption of the existing column. The axial stiffness and strength of the strengthened columns were insignificantly affected by the arrangement methods of closed hoops in the jacket section. The axial ductility ratio of the strengthened columns P, V, and PF was enhanced more than twice of that measured in the non-seismic existing column. However, the column F exhibited a lower ductility than the other strengthened columns because of the fracture of the mesh at the ultimate strength of the column. The V-clip approach was favorable to enhance the ductility of the strengthened column, preventing the opening of the legs of channel-type bars.