• Title/Summary/Keyword: Colour vision test

Search Result 5, Processing Time 0.019 seconds

A Computerized Scoring Method of The Hahn Double 15 Hue Test (한식(韓式) 2중(重) 15색상(色相) 검사(檢査)의 컴퓨터를 이용(利用)한 점수화(點數化) 방법(方法))

  • Park, Wan-Seoup;Lee, Jong-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.521-527
    • /
    • 1996
  • The Hahn double 15 hue test is used for social and vacational aptitude test to separate strongly and mildly affected subjects among the colour vision defective persons, detected using colour vision test. However, the assessment of colour vision defect type and severity is based on the hue confusions which are represented diagrammatically on Hahn double 15 hue score sheet, this qualitative assessment of the test results have not provide a numerical score suitable for methematical analysis. This paper presented a new proposal for quantitatively scoring the Hahn double 15 hue test based on those hue confusions made by the subject. With this program large numbers of double 15 hue test results can be processed easily and rapidly, and program helps to compare the severity of specific type colour vision defect and monitor acquired colour vision defect which has various disease process, continuously.

  • PDF

A Comparison Study of Colour Perception considering Peripheral Vision on Display Device (디스플레이상에서 주변시를 고려한 색채 인지 비교 연구)

  • Hong, Ji-Young;Park, Yun-Sun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.43-53
    • /
    • 2016
  • In this study, under the assumption that there may be differences in colour attributes that can be perceived according to the brightness of the background and the size of the colour stimulus, a test was conducted where colour matching was done for stimulus sizes of $10^{\circ}$ and $20^{\circ}$ in terms of peripheral vision by varying the background brightness. The test results showed that depending on the background brightness and the specific combinations of the Munsell colour attributes used as the test stimulus, colours can be perceived differently even if they are the same colours. In addition, in contrast to findings from previous studies on colour perception according to the stimulus size, it was found that even if the size of the colour stimulus is relatively small, colours can be perceived more colourfully or more brightly with changes in the background brightness. Based on the findings of this study, degradation in image quality can be improved, which may occur when the size of the input image is changed at a later time, and also, contributions can be made when it comes to the reproduction of effective sold three-dimensional structures that reflect visual qualities when processing 3D holographic imagery, in addition to 2D imagery.

Discussion on Preliminary Test for Male High School Students in Gwang-ju Area (광주지역 남자 고등학생들의 예비검사에 대한 고찰)

  • Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.95-99
    • /
    • 2007
  • This study performed apreliminary test with male high school students in Gwangju metropolitan city in order to determine visual function information of high school students. For the items in this preliminary test, there were inquiry, test for long distance unaided visual acuity, pinhole visual acuity test, colour vision test, cover test and stereo test. Most complaint related to eye was about blurred vision (28.4%) and over 90% of subjects had one or more, and among them, over 50% appealed two or more complaints. 76.1% of all subjects showed less than 0.7 in unaided distance visual acuity. In pinhole visual acuity test, 98% had an improved unaided pinhole visual acuity and most of them experienced an improvement and 2% had no change or dropped. The students with normal stereoscopic vision test were 85.6% and the students under normal range were 14.4%. In colour vision test, 7.9% of them were protanomaly and deuteranomaly and none of them had trichromasy and total color blindness. In cover test, it showed 30.2% of orthophoria, 8.2% of esophoria and 61.5% of exophoria, and none of them had strabismus.

  • PDF

Effect of the Polaroid Lens in Binocular Vision (양안시에서 편광렌즈의 영향)

  • Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.135-151
    • /
    • 2003
  • This study compared the effect of Polaroid$^{(R)}$ lenses on binocular vision by assessing visual acuity, stereopsis, and visual evoked potential(VEP), through Polaroid$^{(R)}$, CR 39 and sunglass lenses. The spectral absorptions of Polaroid$^{(R)}$, CR 39 and sunglass lenses were measured using a spectrophotometer (Hitachi. U-3501). The VEP were recorded by the Nicolet system. Thirty normal adult(fifteen males, fifteen females, mean=21.9 years, range=20 to 25) subjects were recorded. The subjects were provided a history including : general health, family health, medication, genetics, allergy and disease. All had normal or corrected to normal acuity with no history of visual disorders. Corrected visual acuity, colour vision and stereopsis were recorded for each subject monocularly and binocularly. Each test was repealed through the sunglass, CR 39, and Polaroid$^{(R)}$ lenses. Subjects viewed the VEP stimulus both monocularly and binocularly through the test lenses while the VEPs were recorded. The results suggest that the binocular visual acuity and stereoacuity is better than with monocular vision. On other hand, the analysis of VEP suggests that the amplitude of wave is smaller when the monocular eye receives the VEP stimulus compared with that when the binocular eye is stimulated by the VEP target with the sunglass, CR 39, and Polaroid$^{(R)}$ lens. But, the latency period of each eye was similar to results between the dominant eye and the non-dominant eye by the CR 39, sunglass, and polaroid lens. In conclusion, this study indicates that the binocular vision appears to be better through the brown Polaroid$^{(R)}$ lens than through the other test lenses.

  • PDF

Development of An Optometric Questionnaire for the Elderly Suitable for Optical Shops in Korea (한국 안경원 실정에 맞는 노안용 문진표의 개발)

  • Noh, Young-Jin;Kim, Dal-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.161-167
    • /
    • 2010
  • Purpose: The aim of this study was to help the rapid and effective eye-tests of old patients by developing an optometric questionnaire for the elderly suitable for optical shops in Korea. Methods: We surveyed several previous studies about the age-related changes of the eye, and deduced 10 items which were appropriate for optometric eye-tests. Excluding the items that could be easily found in a routine eye-test and that was just physiological changes, we principally chose anomaly items which could be catched by simple oral questions. The questionnaire was mainly composed of clinically important items that were frequently observed. Results: To diagnose optometric symptoms related to eye-aging, we listed 15 questions on the questionnaire for the elderly. Each of the 15 questions was respectively about the decline in the amplitude of accommodation (no.1), anisometropia (no.2), xerophthalmia (no.3), muscae volitantes (no.4-5), dark adaptation (no.6) light and dark adaptation (no.7), contrast sensitivity (no.8), contrast sensitivity and anisometropia (no.9), contrast sensitivity and colour vision (no.10), the field of view (no.11), stereoscopic vision (no.12), colour vision (no.13), cataract (no.14), and presbyopia (no.15). Each question was easy to understand and related to the generally observed symptoms. Conclusions: Our optometric questionnaire for the elderly, which was developed by the procedure mentioned above, was expected to be a help for examining the aging eye and offer the basis of eye-tests of older patients in Korean optical shops.