• 제목/요약/키워드: Color meter

검색결과 171건 처리시간 0.03초

Uniformity calibration of large area full color light emitted diodes screens

  • Gibour, Veronique;Leroux, Thierry;Boher, Pierre;Bouwens, Luc
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.475-478
    • /
    • 2004
  • In this paper, we describe a powerful solution for efficient LED wall calibration through the use of a quality 2D-luminance meter : the MURATest and a dedicated applicative software. The intended calibration allows adjusting individually the intensity of each LED so as to obtain a good uniformity on the module. Furthermore the intensity of each module can be adjusted one to the others so as to obtain a good uniformity on a complete display and maintain it even after module exchange for display maintenance needs.

  • PDF

법랑 재료의 혼합에 따른 색상 변화에 대한 연구 (A Study on the Colors of Enamel Wear)

  • 한두희
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2002년도 춘계학술발표논문집
    • /
    • pp.197-199
    • /
    • 2002
  • Samples of enamel wear for kitchen works were made at the Kordco Enamel Co. We analyzed the colors of enamel wears with Color Meter (JS555). The colors of enamel wears could be controled by mixing ratio of frits and pigments. Many kinds of frits and pigments were tested, and colors of enamel wears could be changed by variable frits. Colors were weakly changed by several mixing ratio of pigments.

Hemoglobin 평가를 위한 초기 기구의 특성 및 측정법 고찰 (A Review of the Characteristics of Early Apparatus and Methods for Hemoglobin Estimation)

  • 권영일
    • 대한임상검사과학회지
    • /
    • 제48권4호
    • /
    • pp.401-410
    • /
    • 2016
  • 19세기 후반부터 과학적 논리와 기술이 임상병리학 분야에 적극적으로 활용되기 시작하였다. 이로 인해 많은 검사들이 도구와 기기를 이용하기 시작하였다. 이 때 등장한 혈색소 측정법 중에서 육안색조비교법이 일반적으로 사용되었고, 비중측정법과 가스정량법은 활용도가 낮았다. 육안색조비교법을 적용한 기기로는 Gowers' hemoglobinometer, von Fleischl's hemoglobinometer, Dare's hemoglobinometer, Oliver's hemoglobinometer 그리고 Haden-Hausser hemoglobinometer, Spencer Hb meter 등이 있다. 육안색조비색법은 초기에 혈액을 증류수를 이용하여 희석하고 용혈시킨 후 색조를 측정하는 방법을 활용하였지만, 이후 측정방법을 개선하면서 혈액을 희석없이 측정하거나 발색의 안전성을 위해 acid 혹은 alkaline hematin을 형성시키는 방법들로 발전하였다. 비중을 이용한 측정법으로 Hammerschlag method와 Schmaltz and Peiper's method가 활용되었지만 대중적으로 사용되지는 않았다. 가스정량법은 van Slyke 장치를 이용하여 간접적으로 헤모글로빈 농도를 추정하는 방법으로 가장 정확한 결과를 제공하였다. 본 조사에서는 19세기 후반과 20세기 초 중반까지 사용된 혈색소 측정기기와 측정법에 대한 특징 및 제한점 등을 알아 보았고, 이를 통하여 현재의 측정방법 및 새롭게 등장하는 기술들에 대한 이해와 응용력을 향상시키고자 하였다. 또한 이번 조사가 진단검사 기술분야의 다양한 역사유물에 대한 고찰뿐만 아니라 역사자료 체계화에 대한 필요성을 자각하는 시발점이 되기를 희망한다.

피복제 적하법에 의한 Ag 피복 Cu 미립자의 제조 및 광학적 특성 (Preparation and Optical Properties of Ag-Coated Cu Powder by Dropping Method of Coating Agent)

  • 유연태
    • 한국재료학회지
    • /
    • 제13권9호
    • /
    • pp.555-560
    • /
    • 2003
  • Ag-coated Cu particles were prepared by dropping method of coating agent and were evaluated by scanning electron microscope and color difference meter. The shape of Cu particles having obvious crystal plan and edge was changed spherically according to the increase of Ag coating amount. When the Ag coating amount was 50 wt% to Cu particles, the whiteness of Ag-coated Cu particles was almost similar to that of pure Ag particles. Adding $NH_4$OH in reductant solution could increase effectively the whiteness of the Ag-coated particles. The Ag-coated particles having the highest whiteness was obtained when the content of hydrazine in reductant solution was 0.48 M.

무채색 무늬가 포함된 배경색의 파스텔색상에 따른 뇌파반응 (Brain Waves Evoked by the Changes of Background Pastel Colors with a Pattern of Achromatic Color)

  • 이희란;김소영;김기성;홍경희
    • 한국의류산업학회지
    • /
    • 제19권5호
    • /
    • pp.653-660
    • /
    • 2017
  • Recently, consumers' evaluation and purchase of online design has been increasing due to the popularization of designing through personal computers, but there has not been enough studies on consumers' brain wave responses depending on the change of PC monitor's color. Therefore, this study investigated how brain waves changed when different background colors with gray patterns were presented through PC monitors. Six background colors with same tone of slightly low saturation were selected, including ivory, yellow, pink, green, blue and pure white as a base color. The brightness and characteristics of color used were analyzed using the luminance meter and color scales. Brain wave was measured by EEG measurement equipment. Brain wave measurement was carried out with 9 subjects at 6 points: F3, F4, T3, T4, O1, and O2. Stimuli were shown for 15 seconds each and black screens were displayed for 15 seconds between each stimulus. As results, the brain waves at O1 responded sensitively by different background colors, followed by F4 and T4. Brain index such as 'RT', 'RA', 'RG', 'RSA', and 'RAHB' showed significant differences depending on the background color at O1, whereas 'RST' differed at F4. Yellow and blue backgrounds pair was the only stimuli that showed significant differences in six brain indices mentioned. Yellow background had higher value of 'RG' at O1 and higher 'RST' at F4, indicating yellow background enhanced concentration. Blue background activated 'RT', 'RA', 'RSA', 'RAHB' at O1, meaning blue background induced calm and stable state.

Colorfastness of Black-Colored Fabrics with Various Fibers

  • Yang, Yoon-Young;Choi, Hae-Woon;Park, Myung-Ja
    • International Journal of Human Ecology
    • /
    • 제9권1호
    • /
    • pp.17-27
    • /
    • 2008
  • Black garments can lose color, image, and be the main cause of color staining when washed with other laundry that can cause color contamination from interaction with other garments. To know the fiber-based dye fastness for colored garments, 4-5 pieces of various fibers of different fabrics were selected; cotton, linen, wool, silk, rayon, acetate, polyester, and nylon. To determine the colorfastness to washing and crocking, the black fabrics were washed with alkali and neutral detergents under the Laund-O-Meter method under the Crockmeter method. In an alkali detergent laundering conditions, most colored samples did not undergo color or light fastness. However, most of the stained fabrics slightly changed in K/S values while other samples underwent severe changes. With neutral detergent laundering, sample fabrics underwent less shrinking, and had less naps. The stained fabrics also underwent less change in K/S values. With time-repeatedly-washing the original sample went through colorfastness to lose color. In crocking fastness, most samples produced good to excellent results under dry conditions but produced relatively low crocking fastness under wet conditions. Natural fibers especially showed lower crocking fastness than artificial fibers. In conclusion, garments of the same color should be laundered together. The black garments that are washed using neutral detergents can decrease the amount of damage from color change. While it is the responsibility of garment producers to provide appropriate quality indications they should also provide adequate instructions for consumers to understand and appropriately cope with the quality indications in order to contribute to establishing a correct laundering method.

Comparing the Dyeing Properties of Synthetic Mordants and Hwangsu Spring

  • Ahn, In-Yong;Suh, Hwa-Jin;Song, Eun-Young;Lee, Kyung-Ok;Kim, Jung-Su;Park, Young-Mi;Kwon, Oh-Oun
    • 한국염색가공학회:학술대회논문집
    • /
    • 한국염색가공학회 2012년도 제46차 학술발표회
    • /
    • pp.121-121
    • /
    • 2012
  • To evaluate the Hwangsu spring as natural mordants effect on dyeing. The natural mordant effect of Hwangsu spring was analyzed by pH, temperature, trace elements and organic matter. Hwangsu spring having pH 2.42 and $14.4^{\circ}C$ was harvested at the end of September, 2011, in Yeongcheon(Gyeongbuk Province, Korea) and left on a $0^{\circ}C$ and $25^{\circ}C$ before use. The Result of ICP analysis, it contain bned Fe(414.9 ppm), Al(88.9 ppm), Mn(4.9 ppm). Dyeing and post-mordant procedure; Fabrics(cotton, silk, rayon) were dyed with natural colorants(Sopbora Japonica L., Caesalpinia sappan L., Allium cepa L.) for 20 min at $80^{\circ}C$. Hwangsu spring, aluminium sulfate $14-18H_2O(Al_2(SO_4)_3{\cdot}14-18H_2O)$, iron sulfate peptahydrate($FeSO_4{\cdot}7H_2O$), copper sulfate pentahydrate($CuSO_4{\cdot}5H_2O$) were used by post mordants. But in the case of Caesalpinia sappan L. was dyed after pre-mordanting with Al(II). The fabrics were dyed with each mordant solutions at $25^{\circ}C$ for 10min. The colorless also was measured by color-differnce meter. Comparison with a synthetic mordants, the K/S values of cotton fabrics dyed with Hwangsu sping were increased.

  • PDF

부항자극에 대한 배수혈 어혈평가를 위한 색소침착 변화분석 (Analysis of Hyperpigmentation Change for Extravasated Blood Evaluation by Cupping Stimulation)

  • 김수병;이나라;주예일;이용흠;정병조
    • Korean Journal of Acupuncture
    • /
    • 제28권1호
    • /
    • pp.53-60
    • /
    • 2011
  • Objectives : Cupping therapy has been used as various treatment methods in oriental medicine clinic for a long time. Specially, Cupping stimulation caused skin hyperpigmentation which has been used as diagnosis method for extravasated blood & inner organs functional disease. But it was difficult to quantitatively measure and analyze the interrelation between extravasated blood and skin hyperpigmentation. The aim of this study is to measure the acupoint's RGB and melanin change pattern by stimulating under fixed 80kPa negative pressure and to evaluate the extravasated blood. Methods : To evaluate extravasated blood, 10 acupoints (left/right BL13, BL15, BL18, BL20, BL23) were stimulated by treatment 80kPa negative pressure for 1 minute. And then we measured the acupoints' skin color change patterns using the color meter, followed by RGB analysis and melanin change pattern. Results and Conclusions : We could observe the correlation of the acupoints' skin color condition related with RGB change pattern. All acupoints' color change degree were different. Regardless of acupoints' color degree due to extravasated blood, we observed in common the fact that RGB values decreased after stimulation and steadily increased according to time. We observed that melanin index increased after stimulation and recovered before stimulation-condition after the lapse of time. In other words, we confirmed the correlation between raised color change degree and $L^*a^*$ index change pattern. Therefore we observed the possibility of charting the $L^*a^*$ index following extravasated blood.

천연식물성 염료의 염색견뢰도에 관한 연구 (A Study on Colorfastness of the Natural Dye)

  • 최인려
    • 한국의상디자인학회지
    • /
    • 제3권1호
    • /
    • pp.5-14
    • /
    • 2001
  • The study was about on the colorfastness of the natural vegetable dye. Impatient Balsamina was chosen as a speciesof the natural vegetable dye. It has a long history for Korean Women‘s grooming on the nail to be reddened, Actually those were very easy to gather and easy to extract the colors from the leaves and the flowers, Also Impatient Balsamina were abundant near our environment. So this was a cue as a natural dye for the wool fabric, This study was designed to testify the possibility of the Impatient Balsamina as a natural vegetable. First, 2 kinds of extracts from the Impatient Balsamina were prepared. Second, 2 kinds of mordants and 3 kinds of dyeing process were used. And the dyed wool fabric were evaluated the color index using Chroma Meter, the result was recorded as L$^*$, a$^*$, b$^*$ value(65.86, 16.40, 36.80). The effect of the mordants was more effective in Cr mordant than Al mordant in the color fastness and the color affinity. The very interesting results were in the colorfastness to the drycleaning, that was graded 4 to 5, but the colorfastness to light was low, graded 2. Impatient Balsamina was veryfied, it could be a natural vegetable dye for the wool fabric.

  • PDF

HIS 칼라모델에서 색상 변환을 이용한 자동차 추적 알고리즘 (Vehicle tracking algorithm using the hue transform in HIS color model)

  • 이주신
    • 한국항행학회논문지
    • /
    • 제15권1호
    • /
    • pp.130-139
    • /
    • 2011
  • 본 논문에서는 HIS 칼라모델에서 색상변환을 이용한 자동차 추적 알고리즘을 제안 하였다. 제안된 알고리즘은 도로위에 두 개의 수평가상 데이터 샘플라인을 설치해 놓는다. 차영상은 프레임과 프레임 사이에서 검출하였다. 검출된 자동차의 차영상에서 색상 분포를 이용해서 자동차 동일성 판별과 차선 변경을 검출하였다. 제안된 알고리즘의 효능성을 검토하기 위하여 도로에 주행하는 자동차를 대상으로 두 가상 샘플라인을 통과하는 자동차의 동일성 판별과 차선 변경을 검출하고, 자동차의 속도 측정기와 제안된 방법을 비교한 결과 0.4% 이내임을 보였다.