Associations Between Mammography and Ultrasound Imaging Features and Molecular Characteristics of Triple-negative Breast Cancer

  • Li, Bo;Zhao, Xin;Dai, Shao-Chun;Cheng, Wen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권8호
    • /
    • pp.3555-3559
    • /
    • 2014
  • Background: The triple-negative breast cancer (TNBC) is an aggressive cancer characterized by the absence of estrogen receptor (ER), progesterone receptor (PR) and human epidermal growth factor receptor 2 (HER2). Preoperative mammography and ultrasound features of TNBC may potentially suggest characteristics of the disease and assist in treatment decisions. Materials and Methods: The study covered 153 patients with TNBC from May 2011 to May 2012 who were confirmed by postoperative pathology results in our hospital. We compared the radiological findings among the patients and sought to determine the significant iconographic features. The biomarkers p53 and Ki-67 are regarded as significant factors in TNBC. They were therefore used to divide the TNBC into four groups for assessment of relationships with TNBC imaging features. Results: On mammography, most TNBCs exhibit obscure (44.3%) masses. On ultrasound, the majority of masses (95.4%) were predominantly indistinct (50.7%), irregular (76.0%) or featuring posterior echo enhancement/shadowing. Color Doppler flow imaging (CDFI) emphasized hypervascular (32.9%) masses. Differences in CDFI by ultrasound among the four groups were statistically significant (p=0.009). There were obvious differences in the percentages of spiculated margin (p=0.049) and intensive posterior echo (p=0.006) with spotty flow imaging by ultrasound between the Ki-67 (+) p53 (+) and other groups. Conclusions: A combination of mammography and ultrasound revealed the imaging characteristics of TNBC included an obscure mass with less attenuated posterior echoes and some vascularity. A worse prognosis was associated with spiculated margin and intensive posterior echoes with spotty flow imaging.

경식도 심초음파 검사를 이용한 판막대치술 환자의 평가 (Postoperative Transesophageal Echocardiographic Evaluation in Patients with Cardiac Valve Replacement)

  • 조건현
    • Journal of Chest Surgery
    • /
    • 제24권3호
    • /
    • pp.265-270
    • /
    • 1991
  • Since advent of the prosthetic cardiac valve replacement, much efforts for accurate assessing value function in-vivo have been attempted. To evaluate the postoperative functional and morphological status of the replaced cardiac valve prosthesis, 33 patients with valve replacement were studied by transthoracic and transesophageal 2-dimensional echocardiac imaging as well as by color Doppler flow velocity imaging. Twenty four patients had mitral valve replacement. 6 patients had aortic valve replacement and 3 patients had both mitral and aortic valve replacement. There were 34 mechanical and 2 biological prosthesis. Comparing to transthoracic echocardiography, transesophageal approach showed transvalvular regurgitant jet flow amid the prosthetic mitral valve ring during. systole and much clear visualization of cardiac chamber behind prosthesis which could give shadowing effect to ultrasound beam. According to the quantitative grading by the length and area of mitral regurgitant flow, 24 out of 27 mitral valves revealed mild degree regurgitation considered as physiological after prosthetic bileaflet valve replacement and the other 3 valves including 2 biological prosthesis had moderate degree regurgitation which was regarded as pathologic one. 2 cases of left atrial thromboses and 1 case of paravalvular leakage which were not visible by transthoracic approach were identified by transesophageal echocardiography in patients with mitral valve replacement and patients with aortic valve replacement respectively. We conclude that in patients with prosthetic mitral valve replacement, transesophageal 2-dimensional imaging with color Doppler can suggest reliable information beyond that available from the transthoracic access even though it gives patient some discomfort to proceed.

  • PDF

계류 고환염전으로 오인된 드문 형태의 고환 림프종: 증례 보고 (Unusual Presentation of a Testicular Lymphoma Mimicking a Missed Testicular Torsion: A Case Report)

  • 김미진;이영환;김유리
    • 대한영상의학회지
    • /
    • 제82권5호
    • /
    • pp.1287-1291
    • /
    • 2021
  • 고환 림프종은 무통성 종괴를 주소로 내원하는 드문 고환 종양이다. 일반적으로 고환 림프종은 칼라 도플러 초음파에서 고혈관성을 보이며, 컴퓨터단층촬영이나 자기공명영상에서 조영증강을 보인다. 저자들은 우측 고환 종대를 주소로 내원한 67세 환자에서 초음파 검사상 크기가 커진 고환 내 혈류가 보이지 않아 계류염전으로 진단하였으나, 전산화단층촬영에서는 주변부에 일부 조영증강을 보이는 종괴로 관찰되었고, 수술 이후 림프종이 진단된 증례를 경험하여 보고하고자 한다.

진단용 초음파 Probe 및 Mode 변화에 따른 초음파 주사빈도가 콩나물 발아 과정에 미치는 영향 (Effect of the Bean Sprouts Growth by Scanning Frequency of Diagnostic Ultrasound Probe Type and Mode Change)

  • 최관용;임현수
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권5호
    • /
    • pp.150-154
    • /
    • 2015
  • Long time ultrasound scan can cause a temperature rise in human tissue and affect the physical body. This is closely connected with patients' safety. So many researchers have been studied on this matter with animals such as mammals and experimental rat, because diagnostic ultrasound has been used many types of human organ to find disease. Therefore, this study is tested on bean sprouts to search how far the tissue temperature changes because of the excessive scanning consequence from ultrasound diagnosis and frequent number of ultrasonic scanning and how much affect their growth. The United States and several European countries have restrictions for number of scanning, while South Korea does not have any limitation for using ultrasound diagnosis. Comparison was that how different condition affect its' growing. The testing group is like many pregnancy moms to have 50 minutes in B-mode and color doppler mode by linear, convex and sector probe every day for a week and the other is to scan only once during the testing period. As a result, it was confirmed that there was a significant growing difference on frequent ultrasonic scanning group compared to normal one. So the final conclusion is that there needs to have a significant limitation of ultrasound scan time and a number of inspection when having for diagnostic ultrasound and recommendation like USA and a few European countries.

Unusual Pseudoaneurysm of the Dorsalis Pedis Artery after an Iatrogenic Injury

  • Lee, Yeiwon;Ryu, Han Young;Kim, Young Jin;Ku, Gwan Woo
    • Journal of Chest Surgery
    • /
    • 제51권3호
    • /
    • pp.213-215
    • /
    • 2018
  • Aneurysm and pseudoaneurysm of the dorsalis pedis artery (DPA) are rare vascular entities. Pseudoaneurysms of the DPA are commonly due to blunt trauma, sharp penetrating injury, fracture, or iatrogenic injury. Herein, we report the case of a patient with a rare iatrogenic pseudoaneurysm that occurred after blood sampling. The diagnosis was suspected based on palpitation of a pulsatile mass on the dorsal foot and confirmed by color Doppler ultrasound and computed tomography angiography. Surgical treatment was successfully performed by reconstruction with an autologous venous graft. The patient recovered well, with no ischemic complications.

정상견에서 전방 췌장십이장 동맥의 초음파학적 혈관 저항지수 (Ultrasonographic Resistive Index of the Cranial Pancreaticoduodenal Artery in Normal Conscious Dogs)

  • Eom, Ki-Dong;Lee, Hae-oon;Seong, Yun-sang;Lee, Jeong-min;Lee, Jong-won;Oh, Tae-ho
    • 한국임상수의학회지
    • /
    • 제20권3호
    • /
    • pp.274-277
    • /
    • 2003
  • 임상적으로 건강한 비글견 17두와 췌장염으로 진단된 5두(요크셔테리어 3두, 토이푸들 2두)의 견에서, 화학보정 없이 전방 십이지장동맥(cranial pancreaticodudenal artery: cPDA) 혈관저항지수(resitive index: RI)를 측정하고 이를 비교 평가하였다. RI 측정을 위해 이중 펄스 색도플러 초음파와 11-MHz 선형 위상차 배열 탐촉자를 이용하였다. 췌장염견(0.75$\pm$0.04)견의 평균 RI는 정상견(0.63$\pm$0.04)과 비교하여 유의성(t = 5.79, p = 0.001)있게 증가된 소견을 보였다. 췌장염에 이환 또는 의증 환축에서는 cPDA의 RI 평가 또한 보조적 진단 가치가 있음을 확인하였다.

Clinical Application of an Image-Guided Intervention in Three Dogs

  • Choi, Minsik;Kwon, Dohoon;Ahn, Jisoo;Ko, Minjung;Ahn, Jiyoung;Jung, Joohyun;Kim, Hakhyun;Kang, Ji-Houn;Chang, Dongwoo
    • 한국임상수의학회지
    • /
    • 제37권2호
    • /
    • pp.100-105
    • /
    • 2020
  • A 9-month-old, 11.3 kg, intact, male, mixed-breed dog was referred for treatment of cor triatriatum dexter (CTD); a 5-month-old, 1.9 kg, intact, male Maltese for pulmonic stenosis (PS); and a 3-year-old, 6.62 kg, intact, female West Highland white terrier for esophageal stricture with regurgitation. A balloon catheter intervention was performed in the dog with CTD, and subsequent color Doppler ultrasound and abdominal ultrasound showed normal blood flow across the perforated membrane dividing the right atrium and the disappearance of the severe ascites present before treatment. Balloon catheter intervention in the dog with PS reduced the blood flow through the stenosis from 5.82 m/s to 3.97 m/s. In the dog with esophageal stricture, balloon catheter intervention widened the esophagus and no subsequent regurgitation was observed. Balloon catheter intervention is an interventional radiology procedure that represents a definitive treatment option for various stenotic lesions in dogs, including CTD, PS, and esophageal stricture. Although interventional radiology procedures for these diseases have already been reported, details of procedures and successful outcome have not been reported in Korea.

Prolonged oral sildenafil use-induced Mondor disease: a case report

  • Chung, Han Sol;Mun, You Ho
    • Journal of Yeungnam Medical Science
    • /
    • 제39권3호
    • /
    • pp.262-265
    • /
    • 2022
  • Penile Mondor disease (MD) is a palpable, painful, subcutaneous induration caused by superficial dorsal penile vein thrombosis. We report a case of penile MD that was suspected to be related to prolonged oral sildenafil use. A 46-year-old man visited our emergency department with sustained penile pain and swelling that began 7 hours after sexual intercourse. He had used oral sildenafil intermittently for 11 years and engaged in sexual intercourse the previous night after taking sildenafil. Examination revealed no evidence of intercourse-related trauma to the genital area or an increase in penile skin temperature. However, penile swelling and tenderness over the protruding dorsal penile vein were noted. A color Doppler ultrasound examination was performed immediately, which showed hyperechoic thrombosis in the right superficial dorsal penile vein that was dilated, with soft tissue swelling and no detectable flow signal in the thrombotic lesion. The patient was diagnosed as having penile MD. The patient was treated conservatively. Some reports have indicated the involvement of sildenafil in thrombogenesis. Physicians should be aware that prolonged oral sildenafil use may be associated with penile MD.

유방의 B세포 림프종의 비전형적 초음파 영상 소견: 증례 보고 (Unusual US Findings of Diffuse Large B-Cell Lymphoma of the Breast: A Case Report)

  • 이경은;우옥희;김정열;조규란;서보경
    • 대한영상의학회지
    • /
    • 제85권2호
    • /
    • pp.415-420
    • /
    • 2024
  • 유방 림프종은 유방 악성 종양의 드문 형태로 유병률이 낮다. 유방 림프종의 초음파 소견은 비특이적인 것으로 알려져 있다. 일반적으로 유방 림프종은 초음파에서 저에코의 단일 종괴로 보이며, 칼라 도플러 초음파에서 고혈관성을 보인다. 이에 저자들은 초음파에서 양측 유방에 다수의 고에코의 결절들로 보이는 비전형적인 유방 림프종의 증례를 보고한다.

카롤리병의 방사선학적 진단에 대한 고찰 (A Study on the Radiographic Diagnosis of Caroli's Disease)

  • 홍여진;김민아;김수빈;송진주;장경훈;전민철;한만석
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.385-392
    • /
    • 2023
  • 카롤리병은 섬유낭성 간질환이다. 상염색체 열성 장애로 담관의 선천적 다발성 확장이 특징이다. 카롤리병을 진단하는 방법으로 전산화단층촬영, 자기공명영상 검사, 담관 조영술, 초음파 검사가 있다. 전산화단층촬영검사는 섬유다낭성 간 질환을 감지하고 구별하는데 필수적이며, 간 내 담관의 확장을 판별하는 데 유용하다. 하지만 조영제를 사용함으로써 일어날 수 있는 부작용에 대한 인지가 필요하다. 자기공명영상검사는 대표적으로 자기공명담췌관조영술 방법을 이용한다. 비침습적 검사로 환자의 고통을 경감할 수 있고, 담췌관부의 해부학적 구조와 병변 유무를 쉽고 빠르게 관찰이 가능하다. 담관 조영술은 비대해진 담관 전체에 걸친 여러 낭성 확장을 직접 시각화할 수 있는 효과적인 진단 방법이다. 하지만 이 시술 또한 침습적인 시술이므로 진단이 아닌 치료 목적으로 권장된다. 초음파 검사는 전산화단층촬영과 유사한 소견을 확인할 수 있다. 간동맥 뿌리는 기존의 그레이 스케일 초음파에서 증명하기 쉽지 않다. 하지만 관 내 혈관 뿌리를 가진 확장된 담관을 묘사할 수 있을 뿐만 아니라 관 내 색상 도플러 신호를 쉽게 식별할 수 있다는 점에서 임상적 가치를 갖고 있다. 최근엔 영상진단의 발전으로 전산화단층촬영 검사, 자기공명영상 검사, 담관 조영술, 초음파 검사 등으로 조기 진단이 가능해졌다. 조기 진단을 통해 치료 후에 장기적인 예후가 개선될 수 있도록 영상 진단 발전에 더욱 기여하고자 각 검사별 카롤리병에 대하여 어떠한 양상이 나타나는지 고찰하였다