• 제목/요약/키워드: Colonic polyp

검색결과 16건 처리시간 0.025초

Evaluation of Enterotoxigenic Bacteroides fragilis from Colonic Washings from Patients Undergoing Colonoscopy

  • Van, Ni;Ahlberg, Ned;Jung, Byung Chul;Lee, Min Ho;Ahn, Seung Ju;Lee, In-Soo;Kim, Yoon Suk;Rhee, Ki-Jong
    • 대한의생명과학회지
    • /
    • 제18권4호
    • /
    • pp.362-368
    • /
    • 2012
  • Enterotoxigenic Bacteroides fragilis (ETBF) is an intestinal commensal bacterium implicated as a risk factor for colon cancer. The key virulence factor is a secreted toxin called B. fragilis toxin (BFT). In this study we used an in vitro bioassay to examine the prevalence of ETBF in colonic washings from patients with colorectal polyps and normal control patients. We found that 9.3% of polyp patients and 10.9% of non-polyp patients harbored ETBF, respectively. A total of nine ETBF clinical isolates were isolated and confirmed to be positive for the BFT gene by PCR analysis and the ability to induce IL-8 secretion in the colonic epithelial cell line HT29/c1. Two of the ETBF clinical strains were characterized further in vitro and in vivo. We found that the two ETBF clinical isolates induced E-cadherin cleavage in HT29/c1 cells and promoted colonic inflammation in C57BL/6 mice. Our results indicate that the prevalence of ETBF in polyp patients were similar in non-polyp patients suggesting that ETBF carriage does not positively correlate to polyp incidence.

A large and pedunculated inflammatory pseudotumor with pseudosarcomatous change of the cecum mimicking a malignant polyp: a case report and literature review

  • Jong Suk Oh;Hyung Wook Kim;Su Bum Park;Dae Hwan Kang;Cheol Woong Choi;Su Jin Kim;Hyeong Seok Nam;Dae Gon Ryu
    • Clinical Endoscopy
    • /
    • 제56권1호
    • /
    • pp.119-124
    • /
    • 2023
  • Inflammatory pseudotumor (IPT) is a rare benign tumor of unknown etiology that can occur in almost any organ system. It has neoplastic features such as local recurrence, invasive growth, and vascular invasion, leading to the possibility of malignant sarcomatous changes. The clinical presentations of colonic IPT may include abdominal pain, anemia, a palpable mass, and intestinal obstruction. A few cases of colonic IPT have been reported, but colonic IPT with pedunculated morphology is very rare. Furthermore, since it can mimic malignant polyps, understanding the endoscopic findings of colonic IPT is important for proper treatment. Herein, we present a case of colonic IPT with pseudosarcomatous changes, presenting as a large polyp, mimicking a malignant polyp in the cecum, along with a literature review.

Relationship between Colonic Polyp Type and the Neutrophil/Lymphocyte Ratio as a Biomarker

  • Karaman, Hatice;Karaman, Ahmet;Erden, Abdulsamet;Poyrazoglu, Orhan Kursat;Karakukcu, Cigdem;Tasdemir, Arzu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권5호
    • /
    • pp.3159-3161
    • /
    • 2013
  • Aim: We designed this study to investigate the neutrophil lymphocyte ratio as a biomarker in distinguishing colonic polyps which are neoplastic or non-neoplastic. Materials and Methods: One hundred and twenty-five patients with colonic polyps were enrolled into the study. The following data were obtained from a computerized patient registry database: mean platelet volume (MPV), uric acid (UA), platelet count (PC), alkaline phosphatase (ALP), gamma-glutamyl transpeptidase (GGT) and the neutrophil to lymphocyte ratio (NLR). Exclusion criteria were active infectious disease, hematological disorders, and malignancies. Colonic polyps divided into two groups as neoplastic polyps (tubular adenoma, villous adenoma, tubulovillous adenoma) and non-neoplastic polyps (hyperplastic polyps, inflammatory pseudopolyps etc). The relationship between colonic polyp type and NLR was evaluated with statistical analysis. Results: There were 67 patients (53.6%) with neoplastic and 58 (46.4%) patients with non-neoplastic polyps. Mean NLRs of neoplastic and non-neoplastic groups were respectively $3.32{\pm}2.54$ and $2.98{\pm}3.16$ (P<0.05). Conclusion: Although sensitivity and specificity are not high, NLR may be used as a biomarker of neoplastic condition of colonic polyps.

Factors influencing endoscopic estimation of colon polyp size in a colon model

  • Koen Robert Beukema;Jaimy A. Simmering;Marjolein Brusse-Keizer;Sneha John;Rutger Quispel;Peter B. Mensink
    • Clinical Endoscopy
    • /
    • 제55권4호
    • /
    • pp.540-548
    • /
    • 2022
  • Background/Aims: Colorectal polyps are removed to prevent progression to colorectal cancer. Polyp size is an important factor for risk stratification of malignant transformation. Endoscopic size estimation correlates poorly with pathological reports and several factors have been suggested to influence size estimation. We aimed to gain insight into the factors influencing endoscopic polyp size estimation. Methods: Images of polyps in an artificial model were obtained at 1, 3, and 5 cm from the colonoscope's tip. Participants were asked to estimate the diameter and volume of each polyp. Results: Fifteen endoscopists from three large-volume centers participated in this study. With an intraclass correlation coefficient of 0.66 (95% confidence interval [CI], 0.62-0.71) for diameter and 0.56 (95% CI, 0.50-0.62) for volume. Polyp size estimated at 3 cm from the colonoscope's tip yielded the best results. A lower distance between the tip and the polyp was associated with a larger estimated polyp size. Conclusions: Correct endoscopic estimation of polyp size remains challenging. This finding can affect size estimation skills and future training programs for endoscopists.

Accuracy of FDG-PET/CT for Detection of Incidental Pre-Malignant and Malignant Colonic Lesions - Correlation with Colonoscopic and Histopathologic Findings

  • Kunawudhi, Anchisa;Wong, Alexandra K;Alkasab, Tarik K;Mahmood, Umar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권8호
    • /
    • pp.4143-4147
    • /
    • 2016
  • Purpose: We evaluated all PET/CTs acquired for patients without a primary diagnosis of colorectal cancer, and compared results for those who had subsequent colonoscopy within 6 months, to assess the accuracy of FDG PET/CT for detection of incidental pre-malignant polyps and malignant colon cancers. Materials and Methods: Medical records of 9,545 patients who underwent F-18 FDG PET/CT studies over 3.5 years were retrospectively reviewed. Due to pre-existing diagnosis of colorectal cancer, 818 patients were excluded. Of the remainder, 157 patients had colonoscopy within 6 months (79 males; mean age 61). We divided the colon into 4 regions and compared PET/CT results for each region with colonoscopy and histopathologic findings. True positive lesions included colorectal cancer, villous adenoma, tubulovillous adenoma, tubular adenoma and serrated hyperplastic polyp/hyperplastic polyposis. Results: Of 157 patients, 44 had incidental colonic uptake on PET/CT (28%). Of those, 25 had true positive (TP) uptake, yielding a 48% positive predictive value (PPV); 9% (4/44) were adenocarcinoma. There were 23 false positive (FP) lesions of which 4 were hyperplastic polyp, one was juvenile polyp and 7 were explained by diverticulitis. Fifty eight patients had false negative PET scans but colonoscopy revealed true pre-malignant and malignant pathology, yielding 23% sensitivity. The specificity, negiative predictive value (NPV) and accuracy were 96%, 90% and 87%, respectively. The average SUVmax values of TP, FP and FN lesions were 7.25, 6.11 and 2.76, respectively. There were no significant difference between SUVmax of TP lesions and FP lesions (p>0.95) but significantly higher than in FN lesions (p<0.001). The average size (by histopathology and colonoscopy) of TP lesions was 18.1 mm, statistically different from that of FN lesions which was 5.9 mm (p<0.001). Fifty-one percent of FN lesions were smaller than 5 mm (29/57) and 88% smaller than 10 mm (50/57). Conclusions: The high positive predictive value of incidental focal colonic FDG uptake of 48% for colonic neoplasia suggests that colonoscopy follow-up is warranted with this finding. We observed a low sensitivity of standardly acquired FDG-PET/CT for detecting small polyps, especially those less than 5 mm. Clinician and radiologists should be aware of the high PPV of focal colonic uptake reflecting pre-malignant and malignant lesions, and the need for appropriate follow up.

Image-Enhanced Endoscopy in Lower Gastrointestinal Diseases: Present and Future

  • Lee, Han Hee;Lee, Bo-In
    • Clinical Endoscopy
    • /
    • 제51권6호
    • /
    • pp.534-540
    • /
    • 2018
  • From dye-assisted conventional chromoendoscopy to novel virtual chromoendoscopy, image-enhanced endoscopy (IEE) is continuously evolving to meet clinical needs and improve the quality of colonoscopy. Dye-assisted chromoendoscopy using indigo carmine or crystal violet, although slightly old-fashioned, is still useful to emphasize the pit patterns of the colonic mucosa and predict the histological structures of relevant lesions. Equipment-based virtual chromoendoscopy has the advantage of being relatively easy to use. There are several types of virtual chromoendoscopy that vary depending on the manufacturer and operating principle. IEE plays distinctive roles with respect to histologic characterization of colorectal polyps and prediction of the invasion depth of colorectal cancers. In addition, the newest models of IEE have the potential to increase adenoma and polyp detection rates in screening colonoscopy.

Automatic Electronic Cleansing in Computed Tomography Colonography Images using Domain Knowledge

  • Manjunath, KN;Siddalingaswamy, PC;Prabhu, GK
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권18호
    • /
    • pp.8351-8358
    • /
    • 2016
  • Electronic cleansing is an image post processing technique in which the tagged colonic content is subtracted from colon using CTC images. There are post processing artefacts, like: 1) soft tissue degradation; 2) incomplete cleansing; 3) misclassification of polyp due to pseudo enhanced voxels; and 4) pseudo soft tissue structures. The objective of the study was to subtract the tagged colonic content without losing the soft tissue structures. This paper proposes a novel adaptive method to solve the first three problems using a multi-step algorithm. It uses a new edge model-based method which involves colon segmentation, priori information of Hounsfield units (HU) of different colonic contents at specific tube voltages, subtracting the tagging materials, restoring the soft tissue structures based on selective HU, removing boundary between air-contrast, and applying a filter to clean minute particles due to improperly tagged endoluminal fluids which appear as noise. The main finding of the study was submerged soft tissue structures were absolutely preserved and the pseudo enhanced intensities were corrected without any artifact. The method was implemented with multithreading for parallel processing in a high performance computer. The technique was applied on a fecal tagged dataset (30 patients) where the tagging agent was not completely removed from colon. The results were then qualitatively validated by radiologists for any image processing artifacts.

Profile of Colorectal Polyps: a Retrospective Study from King Fahad Hospital, Madinah, Saudi Arabia

  • Albasri, Abdulkader;Yosef, Hala;Hussainy, Akbar;Bukhari, Saud;Alhujaily, Ahmed
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권6호
    • /
    • pp.2669-2673
    • /
    • 2014
  • Aim: To evaluate the predominant colorectal polyps in the Almadinah region of Saudi Arabia. Materials and Methods: In this iretrospective study, we analyzed pathology reports of colonoscopies performed in King Fahad Hospital, Madinah, Saudi Arabia during the period 2006 to 2013. Data based on patient age, gender, size, site and type of polyps and the degree of dysplasia were analyzed by software SPSS 17 and compared with other published studies from different geographic regions of the world. Results: During these years, 224 patients had colonic polyps, of whom 149 (66.5%) were men and 75 (33.5%) were women. The most common types of polyps were adenomatous (166), followed by hyperplastic polyps (24), juvenile (18), inflammatory (13), lipomatous (2) and one patient with Peutz-Jegher polyps. Tubulovillous adenoma was the commonest adenomatous polyp (102), followed by tubular (41) and villous (23) types. The sigmoid colon was the most commonly involved region (36.6%). Dysplasia was significantly associated with female patients who had large size tubulovillous polyps located in the left colon. Conclusions: The type and distribution of colorectal polyps in Saudi Arabia is very similar to Western countries. Patient gender, and size, histological type and location of polyps are closely related to dysplastic change in colonic polyps.

Utility of narrow-band imaging with or without dual focus magnification in neoplastic prediction of small colorectal polyps: a Vietnamese experience

  • Tien Manh Huynh;Quang Dinh Le;Nhan Quang Le;Huy Minh Le;Duc Trong Quach
    • Clinical Endoscopy
    • /
    • 제56권4호
    • /
    • pp.479-489
    • /
    • 2023
  • Background/Aims: Accurate neoplastic prediction can significantly decrease costs associated with pathology and unnecessary colorectal polypectomies. Narrow-band imaging (NBI) and dual-focus (DF) mode are promising emerging optical technologies for recognizing neoplastic features of colorectal polyps digitally. This study aimed to clarify the clinical usefulness of NBI with and without DF assistance in the neoplastic prediction of small colorectal polyps (<10 mm). Methods: This cross-sectional study included 530 small colorectal polyps from 343 consecutive patients who underwent colonoscopy at the University Medical Center from September 2020 to May 2021. Each polyp was endoscopically diagnosed in three successive steps using white-light endoscopy (WLE), NBI, and NBI-DF and retrieved for histopathological assessment. The diagnostic accuracy of each modality was evaluated with reference to histopathology. Results: There were 295 neoplastic polyps and 235 non-neoplastic polyps. The overall accuracies of WLE, WLE+NBI, and WLE+NBI+NBI-DF in the neoplastic prediction of colorectal polyps were 70.8%, 87.4%, and 90.8%, respectively (p<0.001). The accuracy of WLE+NBI+NBI-DF was significantly higher than that of WLE+NBI in the polyp size ≤5 mm subgroup (87.3% vs. 90.1%, p<0.001). Conclusions: NBI improved the real-time neoplastic prediction of small colorectal polyps. The DF mode was especially useful in polyps ≤5 mm in size.

소아 대장용종증 환자의 임상양상 및 내시경적, 조직학적 소견 (Clinical, Endoscopic and Pathologic Findings of Colonic Polyposis in Korean Children)

  • 임미선;서정기;고재성;양혜란;강경훈;김우선
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제13권2호
    • /
    • pp.154-163
    • /
    • 2010
  • 목 적: 대장용종증은 소아에서는 드문 질환군으로 다수의 용종으로 인한 출혈, 복통, 장중첩증 등이 반복될 수 있고 용종의 악성화나 장외종양이 발생할 수 있으나 아직은 이에 관한 연구가 많지 않다. 본 연구에서는 소아 대장용종증의 임상 양상과 내시경적, 조직학적 특징을 살펴보고자 하였다. 방 법: 서울대병원 어린이병원에서 1987년부터 2009년까지 대장내시경을 시행 받은 2,956명의 소아 환자중에서 대장용종증으로 진단받은 37명의 환자를 대상으로 의무기록 분석을 시행하였다. 대장용종증 환자들의 진단 시 평균나이는 8세였다. 결 과: Peutz-Jeghers 증후군이 22예로 가장 많았으며 연소성 용종증 7예, 가족성 선종성 용종증 6예, 림프성용종증 2예이었다. 내원 시 가장 흔한 주소는 혈변이었다. 50% 이상의 환자에서 혈변과 복통이 동반되었고 일부에서 항문종괴, 설사, 변비가 동반되었다. 용종의 수와 크기는 다양하였고 위장과 소장에 용종이 동반된 환자는 각각 21명, 17명이었다. Peutz-Jeghers 증후군 환자에서는 주로 다엽성의 목이 있는 용종이 관찰되었다. 연소성 용종증 환자에서는 둥글고 목이 있는 용종이 대부분이었다. 가족성 선종성 용종증 환자에서는 작고 둥글며 목이 없는 용종이 관찰되었다. 림프성 용종증 환자에서는 목이 없는 용종이 관찰되었다. 모든 환자는 내시경적 용종절제술을 시행받았고 14명(38%)은 수술적 용종절제술을 시행받았다. 부분장절제술을 시행받은 환자는 13명(35%)이었고, 가족성 선종성 용종증 환자 4명은 전대장절제술을 시행받았다. Peutz-Jeghers 증후군 환자 중 일부에서 장외 종양이 발생하였으나 용종의 악성화는 없었다. 결 론: 소아의 대장용종증 환자는 출혈, 복통 등의 증상을 보이며 장중첩증 등의 합병증이 발생할 수 있어 조기 진단과 치료가 필요하며 정기적인 대장내시경 검사를 통해 합병증을 예방하고 용종의 악성화나 장외 종양 여부를 확인해야 한다.