• 제목/요약/키워드: Colloidal suspensions

검색결과 45건 처리시간 0.022초

열전달 유체 적용을 위한 카본 나노유체 특성 분석 (Characterization of carbon nanofluids applicable to heat transfer fluids)

  • 김두현;황유진;권영환;이재근;홍대승;문성용;김수형
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.538-541
    • /
    • 2008
  • The carbon laden suspensions in water with no surfactants have poor stability caused by the hydrophobic layer of particles. In this study, the water-based carbon nano colloide(CNC) was successfully produced using electro-chemical one-step method without agent. The properties of CNC were characterized by using various techniques such as particle size analyzer, TEM, FT-IR, turbidity meter, viscometer, and transient hot-wire method. The average size of the suspended in the CNC was 15 nm in diameter. The thermal conductivity of CNC compared with water was increased up to 14% with 4.2wt% concentration. The CNC was stable over 600hr. The enhanced colloidal stability of CNC may be caused by the chemical structures, such as, hydroxide and carboxyl groups formed in outer atomic layer of carbon, which (i) made the carbon nanofparticles hydrophilic and (ii) prevented the aggregation among nanoparticles.

  • PDF

무기 콜로이드 현탁액의 십자류 정밀여과에 의한 투과유속의 감소거동 (Flux Decline Behavior in Cross-flow Microfiltration of Inorganic Colloidal Suspensions)

  • 남석태;한명진
    • 멤브레인
    • /
    • 제15권4호
    • /
    • pp.338-348
    • /
    • 2005
  • 정밀여과 모세관 막을 이용한 무기 콜로이드 현탁액의 투과유속 감소특성을 검토하였다. 무기 현탁입자의 종류에 따른 투과거동은 알루미나 현탁액의 투과유속이 벤토나이트 현탁액보다 평균 2배정도 컸으며, 운전시간 경과에 따른 투과유속의 감소도 알루미나 현탁액이 벤토나이트 현탁액에 비하여 전체적으로 서서히 감소하는 경향을 보였다. 운전 시간 10분까지의 투과유속 감소율을 나타내는 초기투과유속 감소율은 벤토나이트 현탁액이 알루미나 현탁액보다 더 컸다. 막 투과유속 감소는 케익오염과 세공막힘오염에 기인하며, 막오염 형태에 있어 벤토나이트 현탁액의 세공막힘오염이 알루미나 현탁액 보다 현저히 크게 나타났다. 운전압력 $1.0\;kg_f/cm^2$에서 총 막오염에 대한 성분오염의 비율은 알루미나 현탁액의 경우 완전세공막힘 $9.35\%$, 표준세공막힘 $6.82\%$, 케익여과 $83.832\%$이었다. 순환흐름속도의 증가로 인해 투과유속은 증가하였고, 알루미나 현탁액은 $6.5\%$, 벤토나이트 현탁액은 $13.5\%$ 증가하였다. 세공크기가 $0.34\;{\mu}m$인 막의 투과유속은 세공의 크기가 $0.24\;{\mu}m$인 막보다 컸으며, 세공크기의 증가에 따른 투과유속은 알루미나 현탁액이 1.61배, 벤토나이트 현탁액이 1.76배 증가하였다.

정밀여과 모세관 막을 이용한 벤토나이트 콜로이드 현탁액의 투과유속 감소특성 (Characteristics of Flux Decline in Microfiltration Capillary Membrane of Bentonite Colloidal Suspensions)

  • 남석태;한명진
    • 멤브레인
    • /
    • 제15권1호
    • /
    • pp.52-61
    • /
    • 2005
  • 폴리에틸렌 정밀여과 모세관막을 이용한 벤토나이트 콜로이드 현탁액의 투과유속 감소특성을 검토하였다. 운전시간이 경과하면서 투과유속이 감소되는 원인은 막표면 위에서 케익층의 성장과 입자들에 의한 세공막힘 때문이었으며, 운전시간이 경과하여 정상상태에 도달하면 투과유속은 케익여과 모델에 의해 지배받는다. 운전압력이 높은 경우의 투과유속 감소는 세공막힘과 케익층이 치밀해졌기 때문이다. 운전압력이 증가함에 따라 J/J₁는 감소하였으며, 0.5 kg/sub f//㎠일 때의 45%, 2.0 kg/sub f//㎠일 때 38%로 감소하였다. 운전압력 0.5 kg/sub f//㎠에서 총 막오염에 대한 성분오염의 비율은 표준세공막힘 14.6%, 완전세공막힘 23.4% 그리고 케익여과 62.0% 이었다. 순환흐름속도의 증가로 인해 투과유속은 증가하였고, 그 효과는 운전압력이 1.0 kg/sub f//㎠일 때가 운전압력 2.0 kg/sub f//㎠ 경우보다 컸다. 세공크기가 0.34 ㎛인 막의 투과유속은 세공의 크기가 0.24 ㎛인 막보다 컸으며, 용액의 농도에 따른 투과유속은 농도가 낮은 용액이 컸다. 세공크기가 0.34 ㎛인 막의 막오염 형태는 유사하지만 농도가 200 ppm인 용액의 경우 1000 ppm인 용액에 비하여 상대적으로 미약한 세공막힘 현상을 보였다.

Effect of Chemical Stabilizers in Silver Nanoparticle Suspensions on Nanotoxicity

  • Bae, Eun-Joo;Park, Hee-Jin;Park, Jun-Su;Yoon, Je-Yong;Kim, Young-Hun;Choi, Kyung-Hee;Yi, Jong-Heop
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권2호
    • /
    • pp.613-619
    • /
    • 2011
  • Colloidal silver nanoparticles (AgNPs) have been commercialized as the typically stabilized form via the addition of a variety of surfactants or polymers. Herein, to examine the effects of stabilizing AgNPs in suspension, we modified the surface of bare AgNPs with four type of surfactants (NaDDBS, SDS, TW80, CTAB) and polymers (PVP, PAA, PAH, CMC). The modified AgNPs was applied to compare suspension stability and nanotoxicity test using Escherichia coli (E. coli) as a model organism. Modification of AgNPs surface using chemical stabilizer may be not related with molecular weight, but chemical structure such as ionic state and functional group of stabilizer. In this study, it is noteworthy that AgNPs modified with a cationic stabilizer (CTAB, PAH) were importantly toxic to E. coli, rather than anionic stabilizers (NaDDBS, SDS). Comparing similar anionic stabilizer, i.e., NaDDBS and SDS, the result showed that lipophilicity of chemical structure can affect on E. coli, because NaDDBS, which contains a lipophilic benzene ring, accelerated the cytotoxicity of AgNPs. Interestingly, none of the stabilizers tested, including biocompatible nonionic stabilizers (i.e., TW80 and cellulose) caused a reduction in AgNP toxicity. This showed that toxicity of AgNPs cannot be reduced using stabilizers.

층류유동 조건에서 SiO2 나노유체의 대류 열전달 특성에 대한 연구 (Investigation of Convective Heat Transfer Characteristics of Aqueous SiO2 Nanofluids under Laminar Flow Conditions)

  • 박현아;박지현;정락교;강석원
    • 한국산학기술학회논문지
    • /
    • 제17권9호
    • /
    • pp.1-11
    • /
    • 2016
  • 본 연구에서는 벽면으로부터 균일한 열 유속 조건에서 나노유체의 층류유동에 의한 대류 열전달 향상과 관련하여 유동관 내 벽면에서의 나노입자 거동의 영향에 대한 수치해석 및 실험 연구에 대해서 논한다. $SiO_2$ 나노유체의 동적 열전도도는 스테인리스 원형 관(길이 1 m 및 직경 1.75 mm)의 외면에 부착된 T형 열전대를 활용하여 측정하였다. 실험에 사용된 나노유체는 직경이 24 nm인 구형의 $SiO_2$ 나노 입자를 초순수에 분산시켜 제조하였다. 나노 유체의 향상된 열전도도(즉, 최대 7.9 %의 증가)는 기본유체(즉, 초순수)와 나노유체 간 유동에서 벽면 온도 변화를 측정하여 비교함으로써 확인하였다. 하지만, 수치해석 결과에서는 실험으로부터 발견된 경향이 발견되지 못했는데, 이는 수치해석 모델이 기본적으로 연속체역학 및 안정된 콜로이드 용액에 나노 입자를 포함하는 유동특성에 기반을 두기 때문으로 분석된다. 이에 따라, 열교환 표면에서 나노입자와 벽면 간 상호작용(예: 나노입자의 고립된 침전)에 의한 표면특성 변화와 같은 비연속체역학 기반의 효과를 확인하기 위하여, 나노유체의 흐름 직후 정제수를 활용한 추가실험을 수행하였다.