• 제목/요약/키워드: Collision Tube

검색결과 46건 처리시간 0.023초

Hollow Cathode Discharge에서 플라즈마 특성에 관한 연구 (Study on Characteristics of Plasma in Hollow Cathode Discharge)

  • 윤만영;신종순
    • 한국인쇄학회지
    • /
    • 제23권2호
    • /
    • pp.93-101
    • /
    • 2005
  • The measured plasma temperature of Ar hollow cathode discharge for several metal cathodes are about $620\;{\sim}\;780K$ at discharge current of $7\;{\sim}\;10mA$. The optogalvanic signals were measured using hollow cathode discharge tube with argon as buffer gas at change of discharge currents. A change of ionization rate due to electron collision causes an increase or decrease of the electric conductivity. This change in electric conductivity generates the optogalvanic signal. We conclude that optogalvanic signal has close relation with the lowest metastable atoms density at low current.

  • PDF

퍼지 AHP를 이용한 수중터널의 재해위험도 분석 (Risk Assessment of Submerged Floating Tunnels based on Fuzzy AHP)

  • 한상훈
    • 한국산학기술학회논문지
    • /
    • 제13권7호
    • /
    • pp.3244-3251
    • /
    • 2012
  • 대형 해양구조물의 건설과 운영에서 중요한 항목 중의 하나가 재해위험도를 분석하고 평가하는 것이다. 이에 본 연구에서는 수중터널의 건설과 운영 시에 발생할 수 있는 재해 위험요소를 도출하고 퍼지 AHP(Analytic Hierarchy Process) 방법으로 이러한 위험요소의 수준을 파악하고자 하였다. 재해 위험도로는 자연재해 위험도와 인적재해 위험도로 구분하고 이러한 위험도 항목들이 수중터널에 미치는 영향을 전문가 설문을 통하여 조사하였다. 조사된 전문가 설문결과 데이터를 퍼지 AHP 기법으로 분석하여 재해위험도를 각 위험요소별로 정량화하였다. 또한, 수중 터널과 교량, 해저터널, 침매터널의 재해위험도 수준을 분석하여 수중터널이 가지고 있는 고유의 재해위험도 수준을 평가하였다. 재해위험도에서는 쯔나미와 지진이 가장 위험도 인식수준이 높았고, 인적재해 위험도는 화재와 폭발의 위험도 인식이 높은 수준이었다. 또한, 수중터널은 침매터널에 비해서는 1.4배, 교량에 비해서는 3.2배 위험도 인식수준이 높은 것으로 조사되었다.

C-arm CT의 필수 성능평가 기준 마련을 위한 연구 (A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography)

  • 김은혜;박혜민;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

Rovibrational Energy Transitions and Coupled Chemical Reaction Modeling of H+H2 and He+H2 in DSMC

  • Kim, Jae Gang
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제16권3호
    • /
    • pp.347-359
    • /
    • 2015
  • A method of describing the rovibrational energy transitions and coupled chemical reactions in the direct simulation Monte Carlo (DSMC) calculations is constructed for $H(^2S)+H_2(X^1{\Sigma}_g)$ and $He(^1S)+H_2(X^1{\Sigma}_g)$. First, the state-specific total cross sections for each rovibrational states are proposed to describe the state-resolved elastic collisions. The state-resolved method is constructed to describe the rotational-vibrational-translational (RVT) energy transitions and coupled chemical reactions by these state-specific total cross sections and the rovibrational state-to-state transition cross sections of bound-bound and bound-free transitions. The RVT energy transitions and coupled chemical reactions are calculated by the state-resolved method in various heat bath conditions without relying on a macroscopic properties and phenomenological models of the DSMC. In nonequilibrium heat bath calculations, the state-resolved method are validated with those of the master equation calculations and the existing shock-tube experimental data. In bound-free transitions, the parameters of the existing chemical reaction models of the DSMC are proposed through the calibrations in the thermochemical nonequilibrium conditions. When the bound-free transition component of the state-resolved method is replaced by the existing chemical reaction models, the same agreement can be obtained except total collision energy model.

Wind load parameters and performance of an integral steel platform scaffold system

  • Zhenyu Yang;Qiang Xie;Yue Li;Chang He
    • Wind and Structures
    • /
    • 제36권4호
    • /
    • pp.263-275
    • /
    • 2023
  • As a new kind of construction facility for high rise buildings, the integral steel platform scaffold system (ISPS) consisting of the steel skeleton and suspended scaffold faces high wind during the construction procedure. The lattice structure type and existence of core tubes both make it difficult to estimate the wind load and calculate the wind-induced responses. In this study, an aeroelastic model with a geometry scale ratio of 1:25 based on the ISPS for Shanghai Tower, with the representative square profile, is manufactured and then tested in a wind tunnel. The first mode of the prototype ISPS is a torsional one with a frequency of only 0.68 Hz, and the model survives under extreme wind speed up to 50 m/s. The static wind load and wind vibration factors are derived based on the test result and supplementary finite element analysis, offering a reference for the following ISPS design. The spacer at the bottom of the suspended scaffold is suggested to be long enough to touch the core tube in the initial status to prevent the collision. Besides, aerodynamic wind loads and cross-wind loads are suggested to be included in the structural design of the ISPS.

LCD-백라이트용 형광램프의 수은량 (Mercury Quantity in a Fluorescent Lamp for a Backlight of LCD-TVs)

  • 봉재환;김윤중;황하청;김동준;정종문;김정현;구제환;조광섭
    • 한국진공학회지
    • /
    • 제17권6호
    • /
    • pp.495-500
    • /
    • 2008
  • Ne+Ar의 혼합 기체와 수은이 주입된 세관 형광램프에서 플라즈마의 형성에 필요한 기체 수은의 량을 계산하였다. 전자($kT_e{\sim}1\;eV$)와 중성 원자(Ne, Ar, Hg)들과의 충돌에 의한 각 원자들의 이온화를 계산하여, 양광주 플라즈마의 밀도($n_o{\sim}10^{17}m^{-3}$)를 생성하는 조건으로부터 기체 수은 원자의 밀도 $3.43{\times}10^{22}m^{-3}$을 얻었다. $32{\sim}42$ 인치 LCD-TV용 액정표시장치에 사용되는 직경이 4 mm인 형광램프의 혼합 기체 Ne(95%)+Ar(5%) 50 Torr에 대하여, 글로우 방전에 필요한 기체 수은의 량은 $0.02{\sim}0.08\;mg$으로 계산되었다.