• Title/Summary/Keyword: Collimation

Search Result 114, Processing Time 0.019 seconds

A Study on 3-Dimensional Surface Measurement using Confocal Principle (공초점 원리를 이용한 3차원 표면형상 측정에 관한 연구)

  • Kang, Young-June;Song, Dae-Ho;You, Weon-Jae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.2
    • /
    • pp.169-176
    • /
    • 2001
  • In modern industry, the accuracy and the sulfate-finish requirements for machined parts have been becoming ever more stringent. In addition, the measurement and understanding of surface topography is rapidly attracting the attention of the physicist and chemist as well as the engineer. Optical measuring method is used in vibration measurement, crack and defect detection with the advent of opto-mechatronics, and it is expected to play an important role in surface topography. In this study, the principle of confocal microscope is described, and the advanced 3-D surface measuring system that has better performance than the traditional confocal microscope is developed. Suitable fixtures arc developed and integrated with the computer system for generating 3-D surface and form data. Software for data acquisition and analysis of various parameters in surface geometrical features has been developed.

  • PDF

Recent Advances in Nuclear Medicine Imaging Instrumentation (핵의학 영상기기의 최근 진보)

  • Jung, Jin-Ho;Choi, Yong;Hong, Key-Jo;Min, Byung-Jun;Hu, Wei;Kang, Ji-Hoon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.98-111
    • /
    • 2008
  • This review introduces advances in clinical and pre-clinical single photon emission computed tomography (SPECT) and positron emission tomography (PET) providing noninvasive functional images of biological processes. Development of new collimation techniques such as multi-pinhole and slit-slat collimators permits the improvement of system spatial resolution and sensitivity of SPECT. Application specific SPECT systems using smaller and compact solid-state detector have been customized for myocardial perfusion imaging with higher performance. Combined SPECT/CT providing improved diagnostic and functional capabilities has been introduced. Advances in PET and CT instrumentation have been incorporated in the PET/CT design that provide the metabolic information from PET superimposed on the anatomic information from CT. Improvements in the sensitivity of PET have achieved by the fully 3D acquisition with no septa and the extension of axial field-of-view. With the development of faster scintillation crystals and electronics, time-of-flight (TOF) PET is now commercially available allowing the increase in the signal-to-noise ratio by incorporation of TOF information into the PET reconstruction process. Hybrid PET/SPECT/CT systems has become commercially available for molecular imaging in small animal models. The pre-clinical systems have improved spatial resolution using depth-of-interaction measurement and new collimators. The recent works on solid state detector and dual modality nuclear medicine instrumentations incorporating MRI and optical imagers will also be discussed.

EXPERIMENTAL APPROACHES FOR WATER DISCHARGE CHARACTERISTICS IN PEMFC USING NEUTRON IMAGING TECHNIQUE AT CONRAD, HMI

  • Kim, Tae-Joo;Kim, Jong-Rok;Sim, Cheul-Muu;Lee, Sung-Ho;Son, Young-Jin;Kim, Moo-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.135-142
    • /
    • 2009
  • In this investigation, we prepared a 1 and 3-parallel serpentine single PEMFC, which has an active area of $100\;cm^2$ and a flow channel cross section of $1{\times}1mm$. Distribution and transport of water in a non-operating PEMFC were observed by varying flow types and the flow rates (250, 400, and 850 cc/min). This investigation was performed at the neutron imaging facility at the CO1d Neutron RAdiography facility (CONRAD), HMI, Germany of which the collimation ratio and neutron fluence rate are 250, $1{\times}10^{6}n/s/cm^2$, respectively. The neutron image was continuously recorded by a scintillator and lens-CCD coupled detector system every 10 seconds. It has been observed that although the distilled water was supplied into the cathode channel only, the neutron image showed a water movement from the cathode to the anode channel. The water at the cathode channel was completely discharged as soon as the pressurized air was supplied. But the water at the anode channel was not easily removed by the pressurized air except for the 3-parallel serpentine type with 850cc/min of air flow rate. Moreover, the water at the MEA wasn't removed for any of the cases.

The Application of the Running of a Dummy Linac and Accessories (실습을 위한 모형 선형가속기 및 부속기구 제작 활용)

  • Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.123-130
    • /
    • 2008
  • Purpose: To provide practical education, most universities should be equipped with medical appliances in need. As compensatory measures, Gimcheon College has produced in-house dummy linac and dummy accessories, we are going to report efficiency and its usage. Materials and Methods: Dummy linear accelerator (DLINAC-001) has the same mechanical functions as rotation of gantry and collimation in linear accelerator. In addition, to maximize practical education, we have produced and utilized in-house custom blocks, wedge filters, electron cones and head rests. Results: The in-house produced linear accelerator with the same mechanical functions as the linear accelerator, DLINAC-001 can be effectively used in practicing diverse medical instruments. Conclusion: We have produced dummy linear accelerators and dummy accessories and utilized them in practice classes, which can provide the students with clinical training in diverse fields. Consequently, the students exposed to the maximized educational effectiveness can be easily equipped with the practical competence required in real clinical fields.

  • PDF

Development of Optical System for ARGO-M

  • Nah, Jakyoung;Jang, Jung-Guen;Jang, Bi-Ho;Han, In-Woo;Han, Jeong-Yeol;Park, Kwijong;Lim, Hyung-Chul;Yu, Sung-Yeol;Park, Eunseo;Seo, Yoon-Kyung;Moon, Il-Kwon;Choi, Byung-Kyu;Na, Eunjoo;Nam, Uk-Won
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.1
    • /
    • pp.49-58
    • /
    • 2013
  • ARGO-M is a satellite laser ranging (SLR) system developed by the Korea Astronomy and Space Science Institute with the consideration of mobility and daytime and nighttime satellite observation. The ARGO-M optical system consists of 40 cm receiving telescope, 10 cm transmitting telescope, and detecting optics. For the development of ARGO-M optical system, the structural analysis was performed with regard to the optics and optomechanics design and the optical components. To ensure the optical performance, the quality was tested at the level of parts using the laser interferometer and ultra-high-precision measuring instruments. The assembly and alignment of ARGO-M optical system were conducted at an auto-collimation facility. As the transmission and reception are separated in the ARGO-M optical system, the pointing alignment between the transmitting telescope and receiving telescope is critical for precise target pointing. Thus, the alignment using the ground target and the radiant point observation of transmitting laser beam was carried out, and the lines of sight for the two telescopes were aligned within the required pointing precision. This paper describes the design, structural analysis, manufacture and assembly of parts, and entire process related with the alignment for the ARGO-M optical system.

Broad Beam Gamma-Ray Spectrometric Studies with Environmental Materials

  • El-Kateb, Abdul-Hamid Hussein
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.2
    • /
    • pp.75-84
    • /
    • 2018
  • Background: Gamma-ray spectrometry helps in radiation shielding problems and different applications of radioisotopes. Experimental arrangements including broad beam geometries are widely used. The aim is to investigate and evaluate the ${\gamma}-ray$ spectra via attenuation by environmental materials. Materials and Methods: The photo peak to nominated parts in the ${\gamma}-ray$ spectra and the attenuation coefficients ${\mu}_b/{\rho}$ from broad beam geometries are measured for the materials water, soil, sand and cement at the energies 0.662, 1.25, and 1.332 MeV with a $3{^{\prime}^{\prime}}{\times}3{^{\prime}^{\prime}}$ NaI(Tl) detector. Results and Discussion: The ${\gamma}-ray$ spectra vary according to changes in the effective atomic number $Z_{eff}$ of the attenuator, the photon energy and the solid angle. The peak to total ratios are the most sensitive parts to variations in the experimental conditions and overturn in the region 0.663 MeV to 1.332 MeV. This is indicated as inversion trend. The results are discussed in view of $Z_{eff}$ and the experimental conditions. The intensity build-up is larger at the lower energy and larger scattering angles in agreement with Klein-Nishina formula and other results. The build-up factor B is$${\sim_=}$$1 at high ${\gamma}-energies$ and small scattering angles. Conclusion: The sensitivity to material characteristics decrease gradually from peak: to total, to Compton valley, to Compton plateau ratios. Rigorous collimation is necessary at small energies. Cement, of the largest $Z_{eff}$, is characterized by the maximum broad beam mass attenuation coefficients ${\mu}_b/{\rho}$. The obtained results provide information to decide for the suitable experimental set-up based on aim of the work.

Optical Simulation Study on the Effect of Reflecting Properties of Reflection Films on the Performances of Collimating Films for the LCD Backlight Applications

  • Lee, Jeong-Ho;Ju, Young-Hyun;Park, Ji-Hee;Lee, Ji-Young;Nahm, Kie-Bong;Ko, Jae-Hyeon;Kim, Joong-Hyun
    • Journal of Information Display
    • /
    • v.9 no.1
    • /
    • pp.26-32
    • /
    • 2008
  • The dependence of optical performances of collimating films such as prism films and pyramid films on the reflecting properties of reflection films were investigated by using a ray tracing technique. The angular distribution of the luminance and the on-axis luminance gain were obtained by using a simple backlight model composed of a reflection film, a virtual flat light source, and a collimating film. Three kinds of reflecting properties were used, which were a perfect Lambertian reflector, a perfect mirror reflector, and a reflector having both diffuse and specular properties. It was found that the on-axis luminance gain was the highest in the simulation where a mirror reflector was used, while the viewing angle was the widest where the Lambertian reflector was used. This result indicates that it is necessary to optimize the simulation condition such as the reflecting properties in order to predict the optical performances of collimating films accurately. Quantitative correlation between the optical characteristics of collimating films and the reflecting properties of reflection films can be used to improve simulation technique for the development and the optimization of collimating films for LCD backlight applications.

Analysis of Coast Topography by RTK GPS and Echo Sounder

  • Lee, Jea-One;Kim, Jin-Soo
    • Korean Journal of Geomatics
    • /
    • v.2 no.1
    • /
    • pp.57-64
    • /
    • 2002
  • Measuring the depth of water is very important in ensuring the protection and safety of seaside. There are many difficulties in making the contour bathymetric map, and contour line due to the limitation of continuous measurement of water depth and collimation with the conventional measuring and positioning methods. But the real-time kinematic GPS (RTK GPS) positioning using a carrier phase enables us to decide a precise position without breaking a signal even under the condition of a moving environment. It is also possible to obtain an accurate depth of water in real time with a fathometer through the measuring of time delay between sending and receiving epochs. This research aims at investigation of accuracy potential of RTK GPS in combination with Echo Sounder(E/S) for the coastal mapping. Apart from this purpose, the accuracy of ambiguity resolution with the OTF(On the Fly) method was tested with respect to the initialization time. The result shows that the accuracy is better than 1cm with 5-minute initialization in the distance of 10km baseline. The seaside topography was measured by the RTK GPS only, on the other hand the seafloor topography was surveyed in combination of RTK GPS and E/S. Comparing to the volume of seaside measured by RTK GPS and digital topographical map, the difference of only 2 % was achieved. This indicates that the coastal mapping with RTK GPS is successfully conducted. In addition it is also demonstrated that the 3-dimensional perspective model resulted from the undersea topography measured by RTK GPS and E/S is very close to that from the digital map. Through this study, it was verified that RTK GPS is to be very useful method in the analysis of coastal morphology owing to its capability of getting the precise DTM for the using of harbor reclamation, dredging, and the estimation of soil movement in a river.

  • PDF

Compact Infrared/Visible Laser Transmitter Featuring an Extended Detectable Trajectory

  • Kim, Haeng-In;Lee, Hong-Shik;Lee, Sang-Shin
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.331-335
    • /
    • 2012
  • A miniaturized laser beam transmitter, in which a visible laser module at ${\lambda}$=650 nm is precisely stacked upon an infrared (IR) module at ${\lambda}$=905 nm, has been proposed and constructed to provide an IR collimated beam in conjunction with a collinear monitoring visible beam. In particular, the IR beam is selectively dispersed through a perforated sheet diffuser, so as to create a rapidly diverging close-range beam in addition to a highly defined long-range beam simultaneously. The complementary close-range beam plays a role in mitigating the blind region in the vicinity of the transmitter, which is inevitably missed by the main long-range beam, thereby uniformly extending the transmitter's effective trajectory that is sensed by a receiver. The proposed transmitter was designed through numerical simulations and then fabricated by incorporating a diffuser sheet, perforated with an aperture of 2 mm. For the manufactured transmitter, the IR long-range beam was observed to have divergences of ~2.3 and 1.6 mrad in the fast and slow axes, respectively, while the short-range beam yielded a divergence of ~24 mrad. The angular alignment between the long-range IR and visible beams was as accurate as ~0.5 mrad. According to an outdoor feasibility test involving a receiver, the combination of the IR long- and short-range beams was proven to achieve a nearly uniform trajectory over a distance ranging up to ~600 m, with an average detectable cross-section of ${\sim}60{\times}80cm^2$.

Development of Multi-channel Fiber Laser and Beam Alignment Method (다채널 광섬유 레이저 및 다중 빔 정렬 기술 개발)

  • Kim, Youngchan;Ryu, Daegeon;Noh, Young-Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.245-251
    • /
    • 2022
  • We have developed a multi-channel fiber laser for tiled laser beam combining and a laser output array system for multi-beam alignment. The fiber laser is a master oscillator power amplifier configuration that has a common seed, a preamplifier, and a 7-channel amplifier. The output power of each channel is more than 10 W. The laser output array system is a packed cylindrical configuration for a high fill-factor, and it has capabilities for collimation and tilt control with built-in PZT. Multi-beam alignment to a target is successfully implemented using PZT controlled with a stochastic parallel gradient descent (SPGD) algorithm.