• Title/Summary/Keyword: Collimating Film

Search Result 12, Processing Time 0.016 seconds

Geometric Region Reconstruction of Steel-tube Computed Radiography Using Nonlinear Structural Analysis (비선형 구도해석에 의한 강관 CR영상의 기하학적 영역복원)

  • Hwang, Jae-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.6
    • /
    • pp.146-152
    • /
    • 2009
  • The steel-tube is exposed to a radiation from X-ray source. The transmitted radiation is detected by a detector, usually film or more recently an imaging plate(IP) of Computed Radiography(CR). The detected radiation overlaps the region of both sides of the object. The radiographic images reflect the projections of the rays, passing twice through both external and internal tube material. Nonlinear distortion due to the radioactive transmission and geometric disposition also appears on images. In this paper, an analytical approach is presented to achieve image reconstruction from the steel-tube CR images. Parameters related to radiation and measuring structure, such as intensities, absorption in material and geometric specifications linked with the collimating components, are calculated and identified in order to construct the renoval images for twofold regions of circle-type steel tubes. A correction procedure for region recovery most similar to the true tube is designed. The application of this approach on CR images is shown and reconstructed results are discussed.

Dose Verification of Intensity Modulated Radiation Therapy with Beam Intensity Scanner System

  • Vahc, Young-Woo;Park, Kwangyl;Ohyun Kwon;Park, Kyung-Ran;Lee, Yong-Ha;Yi, Byung-Yong;Kim, Sookil
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.248-251
    • /
    • 2002
  • The intensity modulated radiation therapy (IMRT) with a multileaf collimator (MLC) requires the conversion of a radiation fluence map into a leaf sequence file that controls the movement of the MLC during radiation treatment of patients. Patient dose verification is clinically one of the most important parts in the treatment delivery of the radiation therapy. The three dimensional (3D) reconstruction of dose distribution delivered to the target helps to verify patient dose and to determine the physical characteristics of beams used in IMRT. A new method is presented for the pretreatment dosimetric verification of two dimensional distributions of photon intensity by means of Beam Intensity Scanner System (BISS) as a radiation detector with a custom-made software for dose calculation of fluorescence signals from scintillator. The scintillator is used to produce fluorescence from the irradiation of 6MV photons on a Varian Clinac 21EX. The BISS reproduces 3D- relative dose distribution from the digitized fluoroscopic signals obtained by digital video camera-based scintillator(DVCS) device in the IMRT. For the intensity modulated beams (IMBs), the calculations of absorbed dose are performed in absolute beam fluence profiles which are used for calculation of the patient dose distribution. The 3D-dose profiles of the IMBs with the BISS were demonstrated by relative measurements of photon beams and shown good agreement with radiographic film. The mechanical and dosimetric properties of the collimating of dynamic and/or step MLC system alter the generated intensity. This is mostly due to leaf transmission, leaf penumbra and geometry of leaves. The variations of output according to the multileaf opening during the irradiation need to be accounted for as well. These phenomena result in a fluence distribution that can be substantially different from the initial and calculative intensity modulation and therefore, should be taken into account by the treatment planning for accurate dose calculations delivered to the target volume in IMRT.

  • PDF