• Title/Summary/Keyword: Collector Method

Search Result 259, Processing Time 0.03 seconds

A Study on the Standardization of Test Method of Flat-Plate Liquid-heating Solar Collectors (액체식 평판형 태양열 집열기 성능 실험의 표준화에 관한 연구)

  • 윤석범
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.3
    • /
    • pp.27-32
    • /
    • 1990
  • Standardization of solar collector test method is desirable for improvement solar collector quality and Valuation of collector thermal performance. In the present work, test loop proposed by Chun, is modified for convenience of test and obtained accurate collector thermal performance. An experimental investigation hat been carried out with a modified collector test loop under a real sun condition in order to confirm the utility of modified test loop and study the effect of variation of flow rate on thermal efficiency, the range of optimum flow rate and critical incident angle.

  • PDF

Probabilistic Structure Design of Automatic Salt Collector Using Reliability Based Robust Optimization (신뢰성 기반 강건 최적화를 이용한 자동채염기의 확률론적 구조설계)

  • Song, Chang Yong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.5
    • /
    • pp.799-807
    • /
    • 2020
  • This paper deals with identification of probabilistic design using reliability based robust optimization in structure design of automatic salt collector. The thickness sizing variables of main structure member in the automatic salt collector were considered the random design variables including the uncertainty of corrosion that would be an inevitable hazardousness in the saltern work environment. The probabilistic constraint functions were selected from the strength performances of the automatic salt collector. The reliability based robust optimum design problem was formulated such that the random design variables were determined by minimizing the weight of the automatic salt collector subject to the probabilistic strength performance constraints evaluating from reliability analysis. Mean value reliability method and adaptive importance sampling method were applied to the reliability evaluation in the reliability based robust optimization. The three sigma level quality was considered robustness in side constraints. The probabilistic optimum design results according to the reliability analysis methods were compared to deterministic optimum design results. The reliability based robust optimization using the mean value reliability method showed the most rational results for the probabilistic optimum structure design of the automatic salt collector.

A Reliability Analysis Application and Comparative Study on Probabilistic Structure Design for an Automatic Salt Collector (자동채염기의 확률론적 구조설계 구현을 위한 신뢰성 해석 응용과 비교연구)

  • Song, Chang Yong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.12
    • /
    • pp.70-79
    • /
    • 2020
  • This paper describes a comparative study of characteristics of probabilistic design using various reliability analysis methods in the structure design of an automatic salt collector. The thickness sizing variables of the main structural member were considered to be random variables, including the uncertainty of corrosion, which would be an inevitable hazard in the work environment of the automatic salt collector. Probabilistic performance functions were selected from the strength performances of the automatic salt collector structure. First-order reliability method, second-order reliability method, mean value reliability method, and adaptive importance sampling method were applied during the reliability analyses. The probabilistic design performances such as reliability probability and numerical costs based on the reliability analysis methods were compared to the Monte Carlo simulation results. The adaptive importance sampling method showed the most rational results for the probabilistic structure design of the automatic salt collector.

Flow Analysis of the Rotating Sludge Suction Collector by Numerical Simulation (수치시뮬레이션을 이용한 흡입식 슬러지 수집기의 유동해석)

  • Suh, Sang-Ho;Roh, Hyung-Woon;Byun, Jong-Youn
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.5 s.38
    • /
    • pp.22-27
    • /
    • 2006
  • Sedimentation phenomenon of suspended solids occurs by the gravitational force. Pollution particles are separated from slowly flowing waste water in clarifier. Recently, the sludge suction collector is Preferred rather than the scraper type sludge collector due to the enhancement of the clarifier efficiency. The sludge suction collector is usually operated by the user's experiences without any scientific and/or technical consideration. To evaluate the performance of sludge suction collector, the three dimensional numerical simulation was conducted by the finite volume method. To analyze the performance, the velocity vectors and the suction flow rates of the orifices were investigated. The result showed that each suction flow rate through out the collector was equivalent in the sludge suction collector and the efficiency of suction collector was good to remove high concentrated sludge in clarifier.

Variation of Flow Characteristics in the Rotating Suction Sludge Collector (흡입식 슬러지 수집기가 회전할 때의 유동특성 변화)

  • Jin, Hee-Nam;Byun, Jong-Youn;Roh, Hyung-Woon;Suh, Sang-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1851-1856
    • /
    • 2004
  • Sedimentation phenomenon of suspended solids occurs by the gravitational force. Pollution particles are separated from slowly flowing wastewater in clarifier. Recently, the sludge suction collector is preferred rather than the scraper type sludge collector due to enhancement of the clarifier efficiency. The sludge suction collector is usually operated by the user's experiences without any scientific and/or technical consideration. To evaluate the performance of sludge suction collector, the three dimensional computer simulation was conducted by the finite volume method. To analyze the performance, the velocity vectors and the suction flow rates of the orifices were investigated. The result showed that each suction flow rate through out the collector was equivalent in the sludge suction collector and the efficiency of suction collector was good to remove high concentrated sludge in clarifier.

  • PDF

Performance Analysis for Sludge Suction Collector in Clarifier (침전지의 흡입식 슬러지 수집기에 대한 성능해석)

  • Jin, Hee-Nam;Byun, Jong-Youn;Suh, Sang-Ho;Roh, Hyung-Woon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.415-420
    • /
    • 2003
  • Sedimentation phenomenon of suspended solids occurs by the gravitational force. Pollution particles are separated from slowly flowing wastewater in clarifier. Recently, the sludge suction collector is preferred rather than the scraper type sludge collector due to enhancement of the clarifier efficiency. The sludge suction collector is usually operated by the user's experiences without any scientific and/or technical consideration. To evaluate the performance of sludge suction collector, the three dimensional computer simulation was conducted by the finite volume method. To analyze the performance, the velocity vectors and the suction flow rates of the orifices were investigated. The result showed that each suction flow rate through out the collector was equivalent in the sludge suction collector and the efficiency of suction collector was good to remove high concentrated sludge in clarifier.

  • PDF

Research on Effective Use of Radiation for Flat plate Type Collector (평판형 집열기에서 일사성분의 유효성에 관한 연구)

  • Choi, Sung-Woo;Chung, Sung-Sik;Ha, Jong-Yul;Kawasima, Yousuke
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2135-2140
    • /
    • 2004
  • This study represented experimental research on the flat plate solar collector. For the flat plate Solar system, it is sensitive of the Global radiation. In Actually, it suppose to be dependent on the direct radiation. Also, the existing method's factors are depend upon Global radiation in the flat plate collector system. therefore it needs which is depend upon direct radiation. In this experiment, the flat plate collector is used for obtaining the method's factors of the direct radiation. As a result, the correct $({\tau}{\alpha})_e$ is found out for practical value.

  • PDF

Characterization of degree of alignment of polymer microfibers electrospun on a rotating water collector

  • Li, Shichen;Lee, Bong-Kee
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.125-130
    • /
    • 2021
  • In this study, the degree of alignment of polymer microfibers produced by electrospinning using a rotating water collector was evaluated. Aligned micro- and nano-fibers are required in various practical applications involving anisotropic properties. The degree of fiber alignment has many significant effects; hence, and accurate quantitative analysis of fiber alignment is necessary. Therefore, this study developed a simple and efficient method based on two-dimensional fast Fourier transform, followed by ellipse fitting. As a demonstrative example, the polymer microfibers were electrospun on the rotating water collector as the alignment of microfibers can be easily controlled. The analysis shows that the flow velocity of the liquid collector significantly affects the electrospun microfiber alignment, that is, the higher the flow velocity of the liquid collector, the greater is the degree of microfiber alignment. This method can be used for analyzing the fiber alignment in various fields such as smart sensors, fibers, composites, and textile engineering.

The Algorithm for Calculating the Base-Collector Breakdown Voltage of NPN BJT for Integrated Circuits (직접회로용 NPN BJT의 베이스-컬렉터간 역방향 항복전압 추출 알고리즘)

  • 이은구;김철성
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.2
    • /
    • pp.67-73
    • /
    • 2003
  • The algorithm (or calculating the base-collector breakdown voltage of NPN BJT(Bipolar Junction Transistor) for integrated circuits is Proposed. The method for calculating the electric field using the solution of Poisson's equation is presented and the method for calculating the breakdown voltage using the integration of ionization coefficients is presented. The base-collector breakdown voltage of NPN BJT using 20V process obtained from the proposed method shows an averaged relative error of 8.0% compared with the measured data and the base-collector breakdown voltage of NPN BJT using 30V process shows an averaged relative error of 4.3% compared with the measured data

A Study on the Thermal Performance of a Solar House by a F-chart Method (F-chart 설계법(設計法)에 의한 태양열주택(太陽熱住宅)의 난방성능(暖房性能)에 관(關)한 연구(硏究))

  • Lee, Young-Soo;Seoh, Jeong-Ill;Yim, Jang-Soon
    • Solar Energy
    • /
    • v.2 no.2
    • /
    • pp.1-9
    • /
    • 1982
  • This paper presents a method. for estimating the useful output of solar heating sys-terns. Heating load calculations, climatic data and various conditions are used in this procedure to estimate the fraction of the monthly heating load supplied by solar energy for a particular system the design procedure presented in this paper referred to the f-chart method. The results of this study are as follows; 1) The collected energy is not rised lineary to collector area. 2) If the heating area has equivalent solar collector area, the solar energy utilization for space heating is over 90%. 3) Transmittance- absorptance product for radiation at normal incidence, (${\tau}{\alpha}$)/(${\tau}{\alpha}$)n, during most of the heating season is 0.92 for a two-cover collector. 4) Orientation of the collector has little effect on the annual performance of solar heating system within the $15^{\circ}$.

  • PDF