• Title/Summary/Keyword: Collection rate

Search Result 1,083, Processing Time 0.026 seconds

An Analysis of the Determinants of the Collection Rate of Agricultural Plastic Waste (영농폐비닐 수거율 결정요인 분석)

  • Yi, Wooell;An, Donghwan
    • Journal of Korean Society of Rural Planning
    • /
    • v.25 no.3
    • /
    • pp.11-18
    • /
    • 2019
  • It is widely known that agricultural plastic waste incineration by farmers may cause big forest fire or fine dust in rural areas. Hence, how to increase the rate of collection and recycling of the agricultural plastic waste is of concern to policy makers especially for rural environment. The purpose of this study is to find the determinants of the collection rate of agricultural plastic waste. This study used the data from 'Research on Agricultural Waste' by the Korea Environment Corporation from year 2012 to 2015 for 163 regions. This study found that the compensation rate for collection, the frequency of collecting services, and the quality of waste are important to increase the collection rate. And the regions with more elderly and low income people are more likely to have higher collection rate. Finally, the chief producing regions that are specialized in a certain crop shows higher collection rate.

An Exploratory Study on Collection Evaluation Indicators for the Collection Development Policy in Public Libraries (공공도서관의 장서개발정책 수립을 위한 장서평가 지표에 관한 탐색적 연구)

  • Oh, Ji-Eun;Jeong, Dong Youl
    • Journal of the Korean Society for information Management
    • /
    • v.32 no.1
    • /
    • pp.43-62
    • /
    • 2015
  • This study was implemented to suggest various indicators of collection evaluation for collection development policy in public libraries. For the sake of the exploratory research, this study tried to show the usability of indicators of collection evaluation through actual data of a case study. Also to analyze indicators of collection evaluation, this study used the ten years circulation records of the Gwangjin District Public Library in Seoul. Majors indicators of collection evaluation were the rate of use and use factor of purchasing books by annual, the rate of use and use factor of librarian's recommended books by annual, the rate of non circulating books by annual, and the rate of use by residence annually.

Characteristics of particulate matter collection efficiency and ozone emission rate of an electrostatic precipitator by thickness of high-voltage electrode and distance of collection plates (고전압 전극 두께와 집진판 간격에 따른 전기집진기의 미세먼지 집진효율 및 오존발생 특성)

  • Lee, Jae-In;Woo, Sang-Hee;Kim, Jong Bum;Lee, Seung-Bok;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.171-180
    • /
    • 2018
  • To optimize the shape of the electrostatic precipitator for the removal of particulate matter in subway environments, the wind-tunnel experiments were carried out to characterize collection efficiency and ozone emission rate. As a standardized parameter, power consumption divided by the square of flow velocity, was increased, the $PM_{10}$ collection efficiency increased. If the standardized parameter is higher than 1.0 due to high power consumption or low flow velocity, increase in thickness of electrodes from 1 to 2 mm, or increase in distance of collection plates from 5 to 10 cm did not change the $PM_{10}$ collection efficiency much. Increase in thickness of high-voltage electrodes, however, can cause decrease in $PM_{10}$ collection efficiency by 28% for low power consumption and high flow velocity. The ozone emission rate decreased as distance of collection plates became wider, because the ozone emission rate per unit channel was constant, and the number of collection channels decreased as the distance of collection plates increased. When the distance of collection plates was narrow, the ozone emission rate increased with the increase of the thickness of electrodes, but the difference was negligible when the distance of collection plates was wide. It was found that the electrostatic precipitator having a thin high-voltage electrodes and a narrow distance of collection plates is advantageous. However, to increase the thickness of high-voltage electrodes, or to increase the distance of collection plates is needed, it is necessary to increase the applied voltage or reduce the flow rate to compensate reduction of the collection efficiency.

An Experiment on the Particle Collection Characteristics in a Packed Wet Scrubber (충진층식 세정집진기의 집진특성 실험)

  • 유경훈;노희환;최은수;김종균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.305-311
    • /
    • 2003
  • DOP aerosol particles with geometric mean diameter of 0.5-3.0 ${\mu}{\textrm}{m}$, geometric standard deviation of 1.1-1.3 and total number concentration of 1,500-8,000 Particles/㎤ were used to determine collection efficiencies of a packed wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. Meanwhile, as for the particle size variation, all of the collection efficiency curves increased rapidly between 0.57-1.41${\mu}{\textrm}{m}$ for the range of water injection rate above 30 L/min. It was also seen that the collection efficiency of a packed wet scrubber is mainly governed by the mechanism of inertial impaction.

A Study on the Analysis of Rate of Use and Core Collection for Collection Evaluation in Public Libraries: in the Case of Gwangjin District Public Library (공공도서관 장서평가를 위한 소장도서 이용도 및 핵심장서 분석에 관한 연구 - 광진정보도서관 사례를 중심으로 -)

  • Oh, Ji-Eun;Jeong, Dong Youl
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.49 no.1
    • /
    • pp.201-221
    • /
    • 2015
  • The purpose of this study is to suggest the usability of collection evaluation methods for collection development policy in public libraries. To achieve this purpose, this study applied Bonn's Use Factor, Turnover Rate of Collection, and Trueswell's 80/20 Rule to actual circulation data of the Gwangjin District Public Library in Seoul during last ten years. This study added practical meanings and values in collection evaluation through the analysis of total holdings and subject classes. Main items of analysis are the rate of use to total holdings and to holdings in specific subject classes by year, and the rate of core collection circulation by year. The results show relations between the rate of use and library's performance through the analysis of the rate of use both total holdings and subject classes. The results also figure out user's patterns and library appraisal of community users through the analysis of circulation data. In addition, the analysis of core collection gives a good basis for an effective collection development policy.

Collection Characteristics of a MOUDI Cascade Impactor for Coarse Particles (다단 임팩터(MOUDI)의 조대 입자 채취 특성)

  • 배귀남;지준호;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.6
    • /
    • pp.799-804
    • /
    • 1999
  • Particle collection characteristics of the MOUDI cascade impactor has been studied for coarse particles in the range of 2 to 20$mu extrm{m}$ in aerodynamic diameter. A vibrating orifice aerosol generator was empolyed to generate monodisperse test aerosols. The oleic acid and sodium chloride(NaCl) particles were used as test aerosols. Aluminum foil and Teflon filter were selected as impaction media. The sampling flow rate was changed from 25 to 35L/min. Particle collection efficiency for single stage was examined for liquid particles. The stage response was obtained experimentally for the cascade impactor composed of three stages and a backup filter. The results showed that most of particle collection efficiencies measured in this work are similar to the efficiency curves obtained by Marple et al.(1991). For particles less than cut-off size of the stage, the collection efficiencies of solid particles are similar to those of loquid particles. However, the collection efficiency of solid particles decreases with mereasing particle diameter for the particles greater than the actual cut-off size of the impactor. The particle collection efficiency increases with increasing sampling flow rate at the same particel size. However, the collection efficiency curves seem not to be greatly shifted with the flow rate. The stage responses obtained by direct measurements in this work are in good agreement with those derived from the collection efficiency curves for single stage.

  • PDF

The effect of temperature and breeding density of piggery on the collection of oral fluid in Korea (국내 양돈장의 사육 온도와 밀사율이 구강액 채취율에 미치는 영향)

  • Byeon, Hyeon Seop;Kim, Mihwa;Kwon, Sungae;Han, Mina;Han, Sung Tae;Jang, Rae Hoon;Chung, Yun-Soo;Kim, Seokhyun;Jeon, Bo-Young
    • Korean Journal of Veterinary Service
    • /
    • v.44 no.4
    • /
    • pp.217-225
    • /
    • 2021
  • We investigated the effect of temperature and stock density on the collection efficiency of oral fluid in the pig farm in Korea. Three pig farms with similar breeding environmental conditions were selected and four pens of each farm (total 12 pens) were tested for the collection efficiency of oral fluid from pigs. Collection rate was considered as significant when oral fluid was collected from 70% of pigs within a pen. In the case of growing pigs, when internal temperature of pig barn increased by one designated degree (5℃), the oral fluid collection rate significantly decreased by 24.7% (P<0.05). The collection rate of oral fluid also decreased by 7.1% (P<0.05) as the density rate increase by one designated degree (12.5%). It was estimated that the collection efficiency of oral fluid decreased when the internal temperature of pig barn was 30℃ or higher, or barn density is higher 25% or high. On the other hand, in the case of stall-housing sows, unlike growing pigs, there was no significant differences according to the temperature, so oral fluid collection was considered to be efficient even in hot season.

Optimization analysis on collection efficiency of vacuum cleaner based on two-fluid and CFD-DEM model

  • Wang, Lian;Chu, Xihua
    • Advances in Computational Design
    • /
    • v.5 no.3
    • /
    • pp.261-276
    • /
    • 2020
  • The reasonable layout of vacuum cleaner can effectively improve the collection efficiency of iron filings generated in the process of steel production. Therefore, in this study, the CFD-DEM coupling model and two-fluid model are used to calculate the iron filings collection efficiency of vacuum cleaner with different inclination/cross-sectional area, pressure drop and inlet angle. The results are as follows: The CFD-DEM coupling method can truly reflect the motion mode of iron filings in pneumatic conveying. Considering the instability and the decline of the growth rate of iron filings collection efficiency caused by high pressure drop, the layout of 75° inclination is suggested, and the optimal pressure drop is 100Pa. The optimal simulation results based on two-fluid model show that when the inlet angle and pressure drop are in the range of 45°~65° and 70Pa~100Pa, larger mass flow rate of iron filings can be obtained. It is hoped that the simulation results can offer some suggestion to the layout of vacuum cleaner in the rolling mill.

An analysis of contributing factors to financial status of regional health insurance (지역의료보험조합의 재정 상태에 영향을 미치는 요인분석)

  • Moon, Jong-Kook;Park, Myeong-Ho;Kim, Yong-Joon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.24 no.2 s.34
    • /
    • pp.211-220
    • /
    • 1991
  • Finances of health insurance can be explained by factors determining benefit expense and premium collection. This study was conducted to analyze factors contributing to the financial status of rural health Insurance. Nationwide 134 health insurance associations except the six pilot project counties were analyzed and obtained the followings. 1. In univariate analysis, statistically significant variables that explain 1) outpatient benefit expenditures include public health center utilization, proportion of pregnant women. premium and collection rate of premium 2) inpatient benefit expenditures include public health center utilization, Proportion of old age, proportion of pregnant women, premium and collection rate of premium 3) profits include public health center utilization, proportion of old age, proportion of pregnant women and collection rate of premium. 2. In multiple regression analysis, statistically significant determinants in 1) outpatient benefit include premium and public health utilization 2) inpatient benefit include premium 3) profit include public health center utilization, premium and collection rate of premium.

  • PDF

Approaches to Studying Low Birth Rate in Korea: A Critical Review (우리나라 저출산 관련 연구 동향 분석)

  • Na, Yu-Mi;Kim, Mi-Kyung
    • Korean Journal of Human Ecology
    • /
    • v.19 no.5
    • /
    • pp.817-833
    • /
    • 2010
  • This study was dedicated to searching better course of low birth rate study in Korea by carefully analyzing past and present low birth rate researches. For this 179 studies(101 master thesis and 78 journal articles) from 1991 to 2009 were analyzed. Next, using SPSS Win 12.0, the research type, topic, participants, data collection and method of data analysis were compared to the studies' years of publication. The most frequently applied research approach, topic, sampling method, data collection procedure and data analysis method in the research was found to be a literature study, solution and prevention of low birth rate related policy, literature study, literacy analysis. In conclusion, low birth rate studies should become more diversified in terms of types of the research, data collection method, and data analysis. Additionally, research topics should become more realistic and specified. Moreover, research results should be verified before they are applied to the policy.