• 제목/요약/키워드: Collapse area

검색결과 339건 처리시간 0.039초

심장이식 후 부신피질호르몬 투여로 인한 거골의 무혈성 괴사 - 1예 보고 - (Corticosteroid-induced Avascular Necrosis of Talus after Cardiac Transplantation)

  • 박홍기;엄기석
    • 대한족부족관절학회지
    • /
    • 제4권2호
    • /
    • pp.83-86
    • /
    • 2000
  • A vascular necrosis of the talus has frequently been reported following trauma because talus has no muscle insertions, sixty percent of the surface of the talus is covered by hyaline cartilage, takes only a small area for entrance of a blood supply. Osteonecrosis is also associated with a variety of nontraumatic disorders. There are many indications for steroid usage, patient with rheumatoid arthritis, systemic lupus erythematosus, chronic obstructive pulmonary disease, and status- post renal or cardiac transplantation may be on long- term steroid usage, osteonecrosis may develop. A vascular necrosis of the talus secondary to chronic steroid usage is an unusual case. Delay in detection of osteonecrosis may lead to fragmentation and collapse of the talar body. When pain on range of motion is present and conservative treatment have been exhausted, surgical treatment is indicated, that is, fusion of the ankle joint. However it is important that conservative treatment may prevent its various sequelae with early diagnosis because steroid - treated patients have a more operative risk and increased risk for postoperative infection. We report a rare case of corticosteroid induced avascular necrosis of talus after cardiac transplantation.

  • PDF

복개 구조물을 이용한 저토피 계곡부 터널의 통과방안에 대한 연구 (A study on the shallow tunneling method using cover structure)

  • 정용진;남현우;최호식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.564-569
    • /
    • 2005
  • Usually, Steel pipe grouting method or cut and cover method has been applied to tunnel with very shallow overburden or it is situated in valley. However, in case of lack of overburden height to reinforcement tunnel crown which is very difficult to construction. Also, application of cut and cover method that do not consider surrounding site condition causes popular enmity generation and environmental damage. It is the best alternative method that reduces the amount of excavated soil and excavate tunnel under ground to solve these problems. The tunneling method using cover structure which is to prevent a tunnel from collapse because this method can be reduce excavation area and construct tunnel under ground after set a cover structure and backfill ground. In this study, to know more effective structure type, comparative analysis was performed to behavior characters of slab and arch type construction that can be used to cover structure. Also a 2D and 3D numerical analysis have been performed to verify the stability of ground during excavation. As the result, the tunneling method using cover structure that it can be good alternative method for tunnel with shallow overburden and it through valley

  • PDF

연약지반내 굴착터널의 안정성 평가 및 최적보강설계에 관한 연구 (Stability analysis of a tunnel excavated in weak rocks and the optimal design for the support pattern)

  • 최성웅;신희순
    • 터널과지하공간
    • /
    • 제7권3호
    • /
    • pp.191-201
    • /
    • 1997
  • Geological and geotechnical surveys, in general, should precede the excavation to ensure the safety of the tunnel and should be followed up according to the various geological condition during the excavation. However actually the standard support patterns which were decided during the design step used be insisted for the whole excavation steps in spite of the various geological conditions. OO tunnel was excavated with NATM and a support pattern type-V in weak rocks. When the tunnel was excavated up to 25m long, the severe displacement was generated in the portal area and the shotcrete was damaged to make the cracks and the tunnel face was totally collapsed. It might happen owing to the one-day heavy rain, but the exact reason for that accident should be found out and the new optimal support patternt needed. Consequently three dimensional numerical analysis was applied for the evaluation of the cause of the tunnel collapse instead of two dimensional analysis, because three dimensional analysis can show better the real field phenomenon than two dimensional analysis in which the load distribution methods are adopted for the tunnel excavation. We could simulate the actual situations with three dimensional finite difference code and propose the new optimal support patterns.

  • PDF

Hybrid Control System for Managing Voltage and Reactive Power in the JEJU Power System

  • Seo, Sang-Soo;Choi, Yun-Hyuk;Kang, Sang-Gyun;Lee, Byong-Jun;Shin, Jeong-Hoon;Kim, Tae-Kyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.429-437
    • /
    • 2009
  • This paper proposes a hybrid voltage controller based on a hierarchical control structure for implementation in the Jeju power system. The hybrid voltage controller utilizes the coordination of various reactive power devices such as generators, switched shunt devices and LTC to regulate the pilot voltage of an area or zone. The reactive power source can be classified into two groups based on action characteristics, namely continuous and discrete. The controller, which regulates the pilot bus voltage, reflects these characteristics in the coordination of the two types of reactive power source. However, the continuous type source like generators is a more important source than the discrete type for an emergency state such as a voltage collapse, thereby requiring a more reactive power reserve of the continuous type to be utilized in the coordination in order to regulate the pilot bus voltage. Results show that the hybrid controller, when compared to conventional methods, has a considerable improvement in performance when adopted to control the pilot bus voltage of the Jeju island system.

굽힘하중을 받는 보강 사각관 보의 좌굴변형거동 해석 (Bending Analysis of Reinforced Tube Beams)

  • 최낙삼;이성혁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.60-65
    • /
    • 2007
  • Local buckling behaviors of aluminum square tube beams reinforced by aluminum plates under three point bending loads have been analyzed using experimental tests combined with theoretical and finite element analyses. For this analysis true stresses were determined from applied loads and cross-sectional area records of a tensile specimen with a rectangular cross-section by real-time photographing. True strains were also obtained from in-situ local elongation measurements of the specimen gage portion by the multi-point scanning laser extensometer. Six kinds of aluminum tube beam specimens reinforced by aluminum plates were employed for the bending test. The bending deformation behaviors up to the maximum load analyzed by the numerical simulation agreed well with experimental ones. After passing the maximum load, reinforcing plate hindering the local buckling of the tube beam was debonded from the aluminum tube beam. An aluminum tube beam strengthened by aluminum plate on the upper web showed the most excellent bending capacity, which could be explained on the basis of the neutral axis shift and the local buckling deformation range.

  • PDF

COLOR GRADIENT IN THE KING TYPE GLOBULAR CLUSTER NGC 7089

  • Sohn, Young-Jong;Chun, Mun-Suk;Lee, Jae-Woo;Oh, Jung-Min
    • Journal of Astronomy and Space Sciences
    • /
    • 제16권2호
    • /
    • pp.91-104
    • /
    • 1999
  • We use BV CCD images to investigate the reality of the color gradient within a King type globular cluster NGC 7089. Surface photometry shows that there is a strong radial color gradient in the central region of the cluster in the sense of bluer center with the amplitude of ~0.39 $\pm$ 0.07 mag/$arcsec^2$ in (B - V). In the outer region of the cluster, however, the radial color gradient shows a reverse case, i.e., redder toward the center. (B - V) color profile which was derived from resolved stars in VGC 7089 field also shows a significant color gradient in the central region of the clusters, indicating that lights from the combination of red giant stars and blue horizontal branch stars cause the radial color gradient. Color gradient of the outer region of NGC 7089 may be due to the unresolved background of the cluster. Similar color gradients in the central area of clusters have been previously observed exserved exclusively in highly concentrated systems classified as post core collapse clusters. We caution, however, to confirm the reality of the color gradient from resolved stars, we need more accurate imaging data of the cluster with exceptional seeing condition because the effect of completeness correlates with local density of stars.

  • PDF

복합통수능시험기를 이용한 실린더형 플라스틱 보드 드레인의 성능 평가 (Capacity Evaluation of Cylindrical Plastic Board Drain with The Composite Discharge Capacity Apparatus)

  • 이찬우;정두회;김윤태;진규남
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.293-299
    • /
    • 2008
  • If a conventional type of Plastic Board Drain (PBD) is installed to the deep clay deposit, it is subjected to a high lateral earth pressure. a flow channel of PBD may be reduced by the collapse of cores and clogged by the intrusion of filter into the space between cores which are made by lateral pressure. It could decrease the ability of initial discharge capacity and the reliability of long term discharge capacity. A cylindrical plastic board drain (C-PBD) considered in this study consists of cylindrical core and several supports so that it can prevent the reduction of area of flow channel from the higher lateral earth pressure effectively. The discharge capacity of C-PBD was compared to that of a conventional PBD through performing experiments using the composite discharge capacity apparatus which can consider in-situ condition such as penetration of drains, ground settlement and discharge capacity. As a result, C-PBD showed much better performance than PBD in the ability of discharge. It was observed that the C-PBD was folded whereas the conventional PBD was folded after the experiment.

  • PDF

지반침하지역에서의 탄성파 굴절법 탐사 적용사례 (Case Study on the Seismic Refraction Survey in a Subsidence Area)

  • 윤상호;지준;이두성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.577-584
    • /
    • 2000
  • Seismic refraction survey was peformed for 10 lines along NE-SW and NW-SE directions above Nampoong gallery at Makyo-ri, Dogye, Samcheok, Kangwon-do. 48 geophones were laid in line with the interval of 1m, and a 5Kg hammer was used as a source at 5 points for each line. Data processing was done using reciprocal time method, GRM, and traveltime tomography which utilizes wavefront expansion method for forward process and SIRT for inversion. The result shows that the first layer has its lower boundary between 3.49m and 8.88m. The P-wave velocity of the first and the second layer were estimated as 270 360m/s and 1550 1940m/s respectively. When the boundary of the first and second layer is smooth enough and the velocity difference is large enough, GRM has little advantage over reciprocal time method. The result of reciprocal method and traveltime tomography shows consistency. The northeast part of the boundary has syncline structure, which is similar to the topography above. This implies that the collapse of the cavities of Nampoong gallery result in the subsidence of the ground surface. The subsidence is in progress across the Youngdong railroad, therefore a proper reinforcement work is required.

  • PDF

선수 충돌시 구조거동과 충돌격벽에 미치는 영향 (Collision Response of Bow Structure and Its Affected Collision Bulkhead in Bow Collision)

  • 신영식;박명규
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.195-204
    • /
    • 2000
  • In this paper a complicated structural behavior in collision and its effect of energy translation to the collision bulkhead was examined through a methodology of the numerical simulation to obtain a ideal bow construction and a location of collision bulkhead against head on collision. In the present the bow structure is normally designed in consideration of its specific structural arrangements and internal and external loads in these area such as hydrostatic and dynamic pressure, wave impact and bottom slamming in accordance with the Classification rules, and the specific location of collision bulkhead by SOLAS requirement. By these studies the behavior of the bow collapse due to collision was synthetically evaluated for the different size of tankers and its operational speed limits, and by the result of these simulation it provides the optimal design concept for the low construction to prevent the subsequent plastic deformation onto or near to the collision bulkhead boundary and to determine the rational location of collision bulkhead.

  • PDF

무한사면에서의 사면붕괴와 보강대책 사례연구 (A Case Study about the Slope Collapse and Reinforcement Method on the Infinite Slope)

  • 유병옥;홍정표;전종헌;이태선;민경남
    • 터널과지하공간
    • /
    • 제16권2호
    • /
    • pp.146-155
    • /
    • 2006
  • 연구지역은 고속도로 신설구간에 형성된 대절토 무한사면으로 불연속면을 따라 사면파괴활동이 시작되었다. 보강은 락앵커 공법을 시공하여 상부구간 안정화를 시도하였다. 그러나 앵커보강 하부구간에 대규모 붕괴가 추가 발생하였고 이후 2차례 더 진행되었다. 붕괴원인을 분석하기 위하여 시료를 채취하고 직접전단시험을 실시하여 잔류전단강도를 확인하였다. 그리고 붕괴지반의 앵커력 확보를 화인하기 위하여 앵커인발시험을 실시하고 앵커설계에 반영하였다. 앵커는 붕괴면의 굴곡이 심하고 연경의 변화가 심한 지반상태를 고려하여 계단식 옹벽과 조합하여 앵커력을 확보하도록 하였다.