• 제목/요약/키워드: Cold-Air

검색결과 1,226건 처리시간 0.025초

빙축열을 이용한 저온공조시스템 운전 특성 연구 (Study on operation characteristics of the cold air distribution systems with an ice storage tank)

  • 염한길;박병규;고득용
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.301-312
    • /
    • 1999
  • Experiments were carried out to evaluate performance of the cold air distribution systems with an ice storage tank in test room. Cold air distribution systems provide primary air for comfort conditioning or process cooling at coil discharge temperatures$4^{\circ}C$ to$11^{\circ}C$. The application of a cold air distribution system allows for the downsizing of air distribution equipment and central plant equipment when ice storage tank is used. The benefit of a cold air distribution system include a decrease in the floor-to-floor height, increase floor space, reduced building capital costs, reduced energy use and demand. The use of cold air distribution can result in the most cost effective system and is currently being implemented world wise as the new standard in air conditioning systems. In this study, the cold air distribution system is compared with the general ice storage system. Under the same cooling load conditions, experimental results show that the supply air volume of cold air distribution system decrease 38%, and decrease 45% flow rate of brine for the general ice storage system.

  • PDF

바람길 활용을 위한 정맥의 찬공기 관리 방안 - 낙남정맥을 사례로 - (Management Strategies of Local Cold Air in Jeongmaek for utilizing urban Ventilation Corridor - A Case Study of the Nak-nam Jeongmaek -)

  • 엄정희
    • 한국지리정보학회지
    • /
    • 제22권1호
    • /
    • pp.154-167
    • /
    • 2019
  • 기후변화에 따른 각종 환경문제가 발생하는 가운데, 도시에서는 폭염, 열대야와 같은 도시 열환경 문제가 심각해지고 있다. 한국은 찬공기 생성에 유리한 산림지역이 국토면적의 약 63%을 차지하고 있으며, 주요 산줄기인 정맥은 도시지역과 밀접하게 위치해 있기 때문에 찬공기를 활용하는 것은 도시 열환경 완화에 매우 효과적인 방안이 될 수 있다. 본 연구에서는 낙남정맥을 대상으로 정맥에 위치한 도시들의 바람길 활용 방안을 마련하기 위해 정맥의 찬공기 특성을 알아보고, 이를 바탕으로 낙남정맥의 찬공기 관리방안을 제안하였다. 또한, 낙남정맥에 위치한 진주시와 산청군을 대상으로 상세분석을 수행하여, 정맥에서 생성된 찬공기 흐름이 인근 도시 지역에 미치는 영향을 분석하고 이를 바탕으로 도시지역에서 찬공기를 활용하기 위한 관리방안을 제시하였다. 찬공기 특성 분석을 위해 독일에서 개발된 모형인 KALM(Kaltluftabflussmodell)을 활용하였으며, 야간 6시간 동안 생성되는 찬공기 흐름 및 찬공기층 높이를 파악하였다. 분석 결과, 시간이 경과함에 따라 정맥에서 생성된 찬공기 흐름이 뚜렷해지고, 찬공기층의 높이는 증가하였다. 찬공기 분석 결과를 바탕으로, 찬공기 흐름을 유지 및 확대할 수 있는 관리방안을 제안하였다. 예를 들어, 찬공기 생성이 활발한 산림지역 일대를 '찬공기 보전지역'으로 지정하고, 원활한 찬공기 흐름을 위해 관리가 필요한 지역을 '찬공기 관리지역'으로 지정하여 전략을 제시하였다. 본 연구의 결과는 낙남정맥에 위치한 도시지역의 쾌적한 열환경 조성을 위한 바람길 활용방안의 일환으로 낙남정맥의 체계적인 관리계획을 수립하는데 기초자료로 활용될 수 있을 것으로 기대한다.

공기공급 시스템에 적용되는 Vortex Tube의 에너지 분리특성에 관한 연구(I) -저온출구 orifice의 직경변화에 의한 영향- (A Study for Energy Separation of Vortex Tube using Air Supply System (I) - the effect of diameter of cold end orifice -)

  • 이병화;추홍록;상희선
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.9-18
    • /
    • 1998
  • The vortex tube is a simple device for separating a compressed gaseous fluid stream into two flows of high and low temperature without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air supply system. The phenomena of energy separation through the vortex tube was investigated experimentally. This study is focused on the effect of the diameter of cold end orifice diameter on the energy separation. The experiment was carried out with various cold end orifice diameter ratio from 0.22 to 0.78 for different input pressure and cold air flow ratio. The experimental results were indicated that there are an optimum diameter of cold end orifice for the best cooling performance. The maximum cold air temperature difference was appeared when the diameter ratio of the cold end orifice was 0.5. The maximum cooling capacity was obtained when the diameter ratio of the cold end orifice was 0.6 and cold air flow ratio was 0.7.

  • PDF

Temporal Variation of Air Temperature in Ice-Valley at Milyang in Association with Ice Formation

  • Lee, Soon-Hwan;Hwang, Soo-Jin
    • 한국지구과학회지
    • /
    • 제28권5호
    • /
    • pp.598-602
    • /
    • 2007
  • A long-term in situ observation was carried out in the Ice-valley at Milyang in order to explain the factors and processes associated with the summertime ice formation. The variation of temperature inside Ice-valley in relation with ice formation in summer time was found to depend on precipitation rate in spring and cold air sinking in autumn and winter. The rate of temperature rising tends to correspond to sensible heat release depending on the precipitation amount at the freezing location. The reason of the cold air accumulation in a talus in the Ice-valley is the cold air sinking over the surface of talus due to the occurrence of outside clod air mass and the accumulated cold air from autumn to spring flow outside at the bottom of talus. The out-flowing cold air can result in the ice formation in the hot summer.

LNG 냉열을 이용한 공기액화분리시스템의 시뮬레이션 및 공정 해석 (Process Analysis and Simulation for System of Air Liquefaction Separation Using LNG Cold Energy)

  • 한단비;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제30권3호
    • /
    • pp.276-281
    • /
    • 2019
  • The process of separating oxygen and nitrogen from the air is mainly performed by electric liquefaction, which consumes a lot of electricity, resulting in higher operating costs. On the other hand, when used for cold energy of LNG, electric power can be reduced compared to the electric Linde cycle. Currently, LNG cold energy is used in the cold refrigeration warehouse, separation of air-liquefaction, and LNG cold energy generation in Japan. In this study, the system using LNG cold energy and the Linde cycle process system were simulated by PRO/II simulators, respectively, to cool the elevated air temperature from the compressor to about $-183^{\circ}C$ in the air liquefaction separation process. The required amount of electricity was compared with the latent heat utilization fraction of LNG, the LNG supply pressure, and the LNG cold energy usage. At the air flow rate of $17,600m^3/h$, the power source unit of the Linde cycle system was $0.77kWh/m^3$, compared with $0.3kWh/m^3$.

압축냉각공기와 오일미스트를 이용한 환경친화 연삭가공기술 (Ecological Grinding Technology Using Compressed Cold Air and Oil Mist)

  • 이석우;최헌종;허남환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.24-27
    • /
    • 2002
  • The environmental problems by using coolant demanded the new cooling methods. As one of them, the studies on the finding with compressed cold air and oil mist have been done. The cooling method using compressed cold air was effective through going down the temperature of compressed air supplied below $-25^{\circ}$ and increasing the amount of compressed cold air, but had not enough cooling effect due to the low performance of lubrication. Therefore, the cooling methods using oil mist newly were suggested. This method can satisfy both cooling effect and lubrication with only small amount of coolant, also have the benefit in the point of decreasing the environmental pollution. This paper focused on analyzing the grinding characteristics of the cooling method using oil mist. The grinding test according to compressed cold air, oil mist spray pressure and oil mist supply direction were done.

  • PDF

저온 냉풍시스템을 이용한 환경친화적 가공시스템의 성능평가 (Performance Evaluation of Environmentally Conscious Machining System Using Low Temperature Air System)

  • 배정철;김경중;김경중;강명창;김정석
    • 한국공작기계학회논문집
    • /
    • 제13권2호
    • /
    • pp.127-132
    • /
    • 2004
  • In industrially advanced countries, environmentally conscious machining was eagerly studied because of ecological and economical reasons. As the environmental regulations become stricter, the new machining technologies which take environmental aspects into consideration are being developed. Recently the research institutions have established application method for dry, semi-dry, oil-mist and compressed cold air machining. In this paper the performance of new compressed cold air system for environmentally conscious machining is investigated and machinability of dry and new compressed cold air machining is evaluated. A series of tests are carried out by using measuring equipments in condition of dry and compressed cold air machining.

촉매가 장착된 가솔린엔진에서 동기화된 2차공기분사에 의한 배기 탄화수소 저감 (Reducing Exhaust Hydrocarbon at Gasoline Engine with Catalytic Converter using Synchronized Secondary Air Injection)

  • 심현성;민경덕;정석호
    • 한국자동차공학회논문집
    • /
    • 제9권2호
    • /
    • pp.67-74
    • /
    • 2001
  • A synchronized secondaty air injection method has been developed to hydrocarbon emission by injecting secondary air intermittently into exhaust port. The method has been tested in a single cylinder spark-ignition engine operating at cold-steady / cold-start conditions. Effects of air injection timing, intake pressure and engine air-fuel ratio have been investigated at cold-steady condition. Also, hydrocarbon emission and exhaust gas temperature with catalytic conberter are compared with a continuous SAI method and base condition at cold-start condition. Resules show that hydrocarbon reduction rate and exhaust gas temperature are sensitive to the timing of synchronized SAI. At cold-steady condition, HC emission is minimum at engine air-fuel ratio of 10. At cold-start condition, the accumulated hydrocarbon emission during the first 120 s decreases about 56% and 22% with the synchronized and continuous SAI, respectively, compared to that of base condition.

  • PDF

운전자 졸음시 냉풍 자극이 뇌파 및 심전도 반응에 미치는 영향 (The Effect of Cold Air Stimulation on Electroencephalogram and Electrocardiogram during the Driver's Drowsiness)

  • 김민수;김동규;박종일;금종수
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.134-141
    • /
    • 2017
  • The purpose of this study was to analyze physiological changes via a cold air reaction experiment to generate basic data that are useful for the development of an automobile active air conditioning system to prevent drowsiness. The $CO_2$ concentration causing drowsiness in vehicle operation was kept below a certain level. Air was blown to the driver's face by using an indoor air cooling apparatus. Sleepiness and the arousal state of the driver in cold wind were measured by physiological signals. It was evident in the EEG that alpha waves decreased and beta waves increased, caused by cold air stimulation. The ${\alpha}/{\beta}$ ratio was reduced by about 52.9% and an alert state confirmed. In the electrocardiogram analysis, the efficiency of cold air stimulation was confirmed by the mean heart rate interval change. The R-R interval had a delay time of about one minute compared to the EEG response. The findings confirmed an arousal effect from sleepiness due to cold air stimulation.

3차원 CFD 시뮬레이션을 이용한 돔형 저온저장고 개발 (Development of Dome-Type Cold Storage Facility Using 3-D CFD Simulation)

  • 양길모;고학균;홍지향
    • Journal of Biosystems Engineering
    • /
    • 제28권1호
    • /
    • pp.35-44
    • /
    • 2003
  • This study was conducted to develop proper model for cold storage facility that could of for uniform heat movement and air movement f3r green grocery and improve improper design of the existing container-type cold storage facility. For that reason, new model(dome-type) cold storage facility was developed using 3-D CFD(computational fluid dynamics) simulation. The size was 6m${\times}$6m${\times}$5m. Its size and configuration were same to simulation model. Unit cooler was designed to send cold air in 4 side ways. A dome-type cold storage facility showed uniform distributions of air temperature and velocity because cold air was forced to move down along the ceiling and the wall and then circulated to the unit cooler from the central part of the floor. Dome-type cold storage facility also showed by low wind velocity, below 1 m/s that could minimized cold damage and quality deterioration.