• 제목/요약/키워드: Cold room

Search Result 415, Processing Time 0.032 seconds

Measurement of Finger Blood Flow in Raynaud's Phenomenon by Radionuclide Angiography (레이노드 현상에서 수지혈류 측정에 관한 연구)

  • Lim, Sang-Moo;Chung, June-Key;Lee, Myung-Chul;Choi, Sung-Jae;Koh, Chang-Soon;Kim, Sang-Joon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.183-190
    • /
    • 1987
  • In Raynaud's phenomenon, the authors measured finger blood flow after ice water exposure by analyzing the time activity curve of radionuclide angiography on both hands. The results were as follows: 1) The digital blood flow did not decrease after ice water exposure in normal subjects. 2) In the patients with Raynaud's phenomenon, there were two groups: the one had decreased digital blood flow after cold exposure, and the other had paradoxically increased digital blood flow after cold exposure. 3) There was no difference in the digital blood flow of hand in room temperature between the normal and the patients with reduced digital blood flow after cold exposure, but the digital blood flow of the hand in room temperature was markedly reduced in the patients with paradoxically increased flow after cold exposure. 4) In the static image the difference was not significant in comparision with the dynamic study, because it represents pooling of the blood in the vein rather than flow. 5) After the treatment with nifedipine, the digital blood flow increased. In conclusion, the radionuclide angiography was useful in measuring the digital blood flow in Raynaud's phenomenon, and further studies with various drugs is expected.

  • PDF

Effect of Humidity on the Storage Life of Satsuma Mandarin (저장습도가 온주밀감의 저장에 미치는 영향)

  • Lee, Sang-Yang;Koh, Jeong-Sam
    • Applied Biological Chemistry
    • /
    • v.42 no.3
    • /
    • pp.223-228
    • /
    • 1999
  • The storage effects of satsuma mandarin(Citrus unshiu Marc. var. miyagawa) by humidity control during storage; 90% relative humidity (RH) and 85% RH at $3^{circ}C$, and room temperature were investigated. After 98 days' storage, weight losses were 3.40% for 90% RH, 6.92% for 85% RH, and 11.87% for room temperature storage. Decay ratio was increased rapidly from 3.87% on 98 days' to 48.75% on 126 days' storage for 90% RH. Soluble solids and flesh ratio were declined gradually, but the differences were not significantly. Firmness of fruits was continuously reduced during storage, especially on room temperature storage by the softening of the fruits. Acid content and vitamin C were gradually reduced during storage. Coloration was continuously progressed on room temperature, compared to cold storage. In order to keep freshness of the fruits, optimum storage period of early variety of Satuma mandarin was regarded for 100 days at $3^{circ}C$, 85% RH on the basis of sensory evaluation and chemical compositions.

  • PDF

Semiquantitative Dynamic Headspace GC-MS Analysis for Organic Compounds Outgassed from FAB Materials of Air Shower (에어샤워부품의 용출 가스 중 유기화합물의 반 정량적 Headspace GC-MS 분석)

  • Park, Hyun-Mee;Baig, Soung-Woo;Kim, Young-Man;Lee, Kang-Bong
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.412-422
    • /
    • 2000
  • The polymeric FAB materials of air shower used in clean room of wafer industry have been outgassed with the dynamic headspace (ca.$100^{\circ}C$) for half an hour, and analyzed using GC-MS. The air in the clean room running air shower was sampled using sorbent tube method, and the organic compounds adsorbed in the sorbent tube were extracted using Soxhlet extraction method, and analyzed using GC-MS. The analytical results from FAB materials of air shower (electric over current relay, acryl plate. polycarbonate window, filter, fan housing, steel galvanized cold plate and canvas buffer) indicated that most of chemicals were originated from polymer fragments of FAB materials. Their analytical results have been compared with those from the air of clean room running air shower. These comparative results could lead to identify whether the sources of trace organic contaminants in clean room air are originated from the polymeric FAB material of air shower.

  • PDF

An Experimental Study on Correlation of Compression Ignition Condition at Cold Start with Hydrogen HCCI Engine (냉시동시 압축착화 조건의 상관관계에 관한 수소 HCCI 기관의 실험적 연구)

  • Lee, Kwangju;Lee, Jonggoo;Ahn, Byunghoh;Lee, Jongtai
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.628-633
    • /
    • 2012
  • It was found that the pure hydrogen-air pre-mixture was self-ignited at a high compression ratio without any assisting method in room temperature, thus refuting the preconception that compression ignition of hydrogen engine was impossible. Therefore, in order to analyze the correlation of compression ignition condition at cold start with hydrogen HCCI engine clearly, the possibility of compression igniting compression ratio is investigated with the change of equivalence ratio and engine speed, experimentally. As the results, it is confirmed that the possibility of compression-igniting compression ratio at cold start was decreased by increasing equivalence ratio due to decreasing auto-ignition temperature. In addition, it is grasped that the possibility of compression-igniting compression ratio at cold start is decreased around 14.9% by increasing engine speed at same supply energy.

The Effect of Cold-rolling on Microstructure and Transformation Behavior of Cu-Zn-Al shape Memory Alloy (냉간가공에 의한 CuZnAl계 현상기억합급의 결정립미세화와 특성평가)

  • Lee, Sang-Bong;Park, No-Jin
    • Korean Journal of Materials Research
    • /
    • v.9 no.3
    • /
    • pp.322-326
    • /
    • 1999
  • In this study, cold-rolling and appropriate annealing was adopted for the grain refining of Cu-26.65Zn-4. 05Al-0.31Ti(wt%) shape memory alloy. For the cold deformation of this alloy the ducti1e $\alpha$-phase must be contained. After heat treatment at $550^{\circ}C$ the $(\alpha+$\beta)$-dual phase with 40vol.% $\alpha$-phase was obtained which could be rolled at room temperature. This alloy was cold rolled into a final thickness of 1.0mm with total reduction degrees of 70% and 90%. The rolled sheets were betanized at $800^{\circ}C$ for various times, then quenched into ice water. The grain size of co]d rolled samples were $60~80\mu\textrm{m}$ which is much smaller comparing with the hot-rolled samples. And the 90% rolled sample showed smaller grain size than the case of the 70% rolled one. The small grain size had influence on the phase transformation temperatures and stabilization of the austenitic phases.

  • PDF

Effect of Mo and Cu Contents on Work Hardening of Cold Drawn Stainless Steel 304H Wires for Spring (스프링용 스테인레스강 304H 신선재의 가공경화에 미치는 Mo와 Cu 농도의 영향)

  • Kim S. W.
    • Korean Journal of Materials Research
    • /
    • v.15 no.10
    • /
    • pp.632-638
    • /
    • 2005
  • To investigate the effect of Mo and Cu contents on tensile strength of cold drawn stainless steel 304H wires, metallographical and mechanical tests were performed for the wire specimens drawn to different drawing strains at room temperature. It was confirmed that the contents of Mo ana Cu have little influence on the tensile strength of drawn specimens, even though the strain induced martensite transformation decreased with increasing the contents of Mo and Cu. These results were explained by the strengthening of the formed martensite itself due to the solid solution effect of interstitial solutes, carbon and nitrogen. The contents of these elements were slightly higher in the specimens containing additionally added Mo and Cu.

A Study on the Catecholamine under the Room Temperature and $5^{\circ}C$ Refrigerator Environment in Rat (실온과 $5^{\circ}C$ 냉장고 환경에서 흰쥐 Catecholamine 분비에 관한 연구)

  • Hong, Seyng-Eui;Yoon, Tai-Young;Kim, Hyung-Suk
    • Journal of Preventive Medicine and Public Health
    • /
    • v.20 no.2 s.22
    • /
    • pp.215-220
    • /
    • 1987
  • Under the extreme change of the environment, animals react physiologically to adapt to the stress and secrete catecholamines. Cold exposure is a kind of the environmental stress. Author tried to determine the amount of catecholamines in rat urine as a parameter of physiological response to cold stress. Urinary catecholamine was measured by using HPLC with fluorescence detector, cation exchange column prepacked with Bio·Rex 70 and ammonium pentaborate as catecholamine eluent. The amount of dopaminc in normal state rat urine was 42.0 ng, but under the low temperature of $5^{\circ}C$, the dopamine amount was increased to 221.25 ng/5 ml. Above findings are suggesting that catecholamine secretion, especially dopamine, increases in the stressful condition such as cold exposure.

  • PDF

A Comparative Analysis and Process Design among the Gear Blank Forging Process (기어블랭크 단조공정의 비교해석 및 공정설계)

  • 최호준;허성창;장동환;황병복
    • Transactions of Materials Processing
    • /
    • v.8 no.6
    • /
    • pp.541-553
    • /
    • 1999
  • Cold forging is a special type of forging process in which metal is forced to flow plastically under compressive force into a variety of shapes in room temperature. Gear blank, which is produced by cold forging, is concerned with the production method of transmission gear. Based on the results of simulation of the current four-stage process, the gear blank forging process for improving the conventional process sequence is designed. The rigid plastic finite element analysis for improving the conventional process. The new process consists of three stage operations with one annealing treatment after first operation. Based on the results of simulation of the proposed process, a required equipment could be selected. The new designed process appears to be more economical in producing the gear blank.

  • PDF

Experiment of tong-neck Flange Cold Forging Process Using Plasticine (플라스티신을 이용한 롱넥 플랜지 냉간 단조 공정의 모사 실험)

  • 이호용;임중연;이상돈
    • Transactions of Materials Processing
    • /
    • v.10 no.1
    • /
    • pp.67-74
    • /
    • 2001
  • The cold forging process to produce a long-neck flange is investigated by using model material test. The two stage process with optimum design condition is examined using plasticine, which is suitable to model steel at room temperature. The similarity theory is employed to estimate the forging load of each sequence by strict application of similarity condition between steel(AISI 1015) and plasticine material The model test results are compared with the simulation results and shows good agreement. The proper forging process with least forming energy can be resulted in $25^{\circ}$ of extrusion semi-die angle.

  • PDF

Effects of skin temperature change, cold pain and muscle activity by Cold Air Application type on the induced delayed onset muscle soreness (지연성 근육통 유발 후 냉기 적용 방법이 피부온도의 변화, 냉각 통과 근육 기능에 미치는 효과)

  • Choi, Yoorim;Jung, Bongjae;Hwang, Byeongjun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.99-106
    • /
    • 2013
  • The purpose of this study was to after induced delayed onset muscle soreness, the purpose of this study is to present the effective way on skin temperature changes and cold pain for 14 subjects during to applied with only Cold-jet stream and Cold-jet stream with infra red. 14 healthy men and women who delayed onset muscle soreness eccentric contractions induced by exercise and then the biceps alone was applied to the Cold-jet stream. We measured the time that skin temperature fall from room temperature to $10^{\circ}C$(first period), the time rewarmed from $10^{\circ}C$ to $20^{\circ}C$(second period), the time fall again to $10^{\circ}C$(third period) and the time rewarmed again to $20^{\circ}C$(fourth period). Cold-jet stream with infrared combination therapy was performed with the same method. Results of this study were 1st and 2nd experimental cooling experiments in the to fall to $10^{\circ}C$ Cold-jet stream with infrared combination therapy than in the Cold-jet stream was longer(p<.05). At second period, It took longer in Cold-jet stream with infrared rewarmed than Cold-jet stream to rewarm skin(p<.05). Cold-jet stream with infrared combination therapy than Cold-jet stream had less incidence of cold pain(p<.05). Thickness of biceps brachii were found significant difference related measurment each group was consistent. In this study, Cold-jet stream with infrared combination therapy more effective than Cold-jet stream in reduced cold pain and lowering skin temperature. This work was supported by education capacity building project fund of Taegu Science University, 2012.