• Title/Summary/Keyword: Cold room

Search Result 415, Processing Time 0.026 seconds

Standardization of Ice Mechanics Experimental Procedures in a Cold Room (Cold Room을 이용한 얼음 및 동토의 재료특성 계측 실험기법의 표준화)

  • Kim, Jung-Hyun;Choi, Kyung-Sik;Seo, Young-Kyo
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.2 s.75
    • /
    • pp.60-66
    • /
    • 2007
  • The first Korean cold room facility for ice mechanics experiments was assembled in 2004. Since then, the $4m{\times}6m$ cold room facility has been used, extensively under various environmental and loading conditions. After reviewing published references on cold room testing methods and also by trial and error, the standard procedures for testing and preparing laboratory ice material were established for the measurement of basic ice properties. In this paper, laboratory experimental techniques with the cold room facility and standard procedures established for ice material properties are introduced. Test specimens include laboratory-grown fresh water ice and frozen soils. Tests are carried out for unconfined compressive strength. Preparation and dimension of the specimen are the most important issues arising in cold room tests. The details of specimen preparation, testing procedure and strength test results are also discussed.

3-D Simulation of Air Flow in Cold Storage Room for Uniform Temperature Distribution (저온저장고 내부의 균일한 온도분포를 위한 3차원 공기유동 분석)

  • 성제중;고학균;조성인;양길모
    • Journal of Biosystems Engineering
    • /
    • v.25 no.4
    • /
    • pp.279-286
    • /
    • 2000
  • Most of the domestic cold storage rooms are inefficient for agricultural products because of temperature gradients inside the storage rooms. Temperature gradients are developed mainly by improper airflow pattern inside the storage room, which is a main cause of the spoilage of the agricultural products. There proper airflow pattern is essential to minimize these temperature gradients and the spoilage. The performance and characteristics of a cold storage room were determined as a function of airflow pattern and temperature distribution in forced circulation cold storage room. A commercial CFD(computational fluid dynamics) code was used to simulate 3-D airflow in the cold storage room. Solving the flow equations for the storage room, a standard k-$\varepsilon$ turbulent model was implemented to calculate steady state turbulent velocity distribution. The CFD prediction results were compared with temperature measurements inside the cold storage room. In case of pallet storage, Temperature gradients inside pallet storage was reduced because the contact area of cold air expanded through an alley of airflow in storage. But is case of bulk storage, the last temperature of storage considerably rose more than the initial temperature of storage. The reason was that bulk storage didn't include any alley of airflow in storage.

  • PDF

Changes of egg Quality according to eggshell treatment and storage condition (계란의 난각 처리와 보관 방법에 따른 품질 변화)

  • Lee Sung-Mo;Hong Chong-Hae
    • Korean Journal of Veterinary Service
    • /
    • v.28 no.3
    • /
    • pp.225-234
    • /
    • 2005
  • Egg has been considered as one of the most important food sources in both nutritionally and economically. However, because the hazards of egg flow chains' complexity from producers to consumers and the insufficiency of cold chain systems in Korea are still remained, preventive measures for egg safety should be established. This experiment was carried out to investigate the changes of egg qualify during storage in order to find out the proper storage condition and eggshell treatment. Eggs were stored at cold condition $(5^{\circ}C,\;relative\;humidity;\;RH:\;65\pm3\%)$ and room Condition $(1st: Sep\; 6\~Nov\; 15,\;2001,\; 10\~30^{\circ}C,\;RH\;41\~86\%,\;2nd;\; Dec\;13,\;2001\~Feb\;21,\;2002,\;4\~23^{\circ}C,\;RH\;36\~89\%)$ after eggshell treatment (unwashed, washed and coated egg) during'10 weeks and examined weight loss and interior quality periodically. Weight loss was in decreasing order room washed > room unwashed > cold washed > cold unwashed > room coated > cold coated egg. And, Haugh unit was decreasing order room washed > room unwashed > room coated > cold washed > cold unwashed > cold coated egg. Our findings show that both coated eggs and refrigeration reduces the rate of decline in Haugh units and egg weight. And, washed eggs had lower average Haugh units and a higher weight loss than any of the eggshell treatment in both storage conditions. Conclusively, for washing eggshell, 150 ppm of sodium hypochlorite, regular exchange and temperature control of water should be consistent and also eggs should be dried immediately after washing. Also, national guidelines for temperature and moisture of storage places, transportation and expiration data should be established to keep quality and weight loss of eggs. Storage temperature that is a critical factor in the quality and safety of eggs should be kept under 12'c and labelling of expiration date should be obligatory.

Establishment of Effective Freshness Indicators for Seafood During Room-Temperature Distribution Using Commercial Cold Packs and Styrofoam Boxes (시판 보냉팩 및 스티로폼 박스 상온 유통시 효율적인 수산물 선도지표 설정)

  • Lee, Ji Un;Heu, Min Soo;Lee, Jung-Suck
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.55 no.5
    • /
    • pp.670-680
    • /
    • 2022
  • Owing to the lack of a cold-chain distribution system, most seafood is generally distributed under room temperature conditions. However the degradation of freshness during the distribution process can lead to disputes between sellers and consumers. The most widely used method for low-temperature distribution for seafood includes packaging it with styrofoam boxes and cold packs. In this study, vacuum-packed frozen fillets of four fish species of [white meat (Paralichthys olivaceus and Sebastes schlegelii) and red meat (Scomber japonicus and Scomberomorus niphonius)] were placed in styrofoam boxes with cold packs. Thereafter, changes in chemical (including pH, volatile basic nitrogen, and trimethylamine), physical (odor intensity, hardness, and chewiness), and microbial (viable cell count) characteristics of the fillets were measured during storage at 25℃. To identify the suitable method of determining freshness during the room-temperature distribution, several factors were considered, which included significant difference verification, correlation coefficients, and economic efficiency (experimental cost and time). Volatile basic nitrogen, pH, odor intensity, and viable cell count are the most rapid and accurate freshness indicators for determining freshness of frozen fish fillets during.

A Study on the Stability of Diluted Bee Venom Solution (봉약침액(蜂藥鍼液)의 안정성(安定性) 연구(硏究))

  • Kang, Mi-Suk;Byun, Im-Jeung;Lee, Seong-No;Kim, Kee-Hyun
    • Journal of Pharmacopuncture
    • /
    • v.6 no.2
    • /
    • pp.105-111
    • /
    • 2003
  • Objective : The purpose of this study was to investigate the stability of bee venom according to the keeping method and period. Method : The author observed microbial contamination of bee venom in nutrient agar, broth, YPD agar and YPD media and antibacterial activity for S. aureus, E. coli manufactured 12, 6 and 3 months ago as the two type of room temperature and $4^{\circ}C$ cold storage. Results : 1. 1:3,000 and 1:4,000 diluted bee venom solution did not show microbial contamination both room temperature and cold storage within twelve months. 2. There was antibacterial activity of diluted bee venom for S. aureus in cold storage within twelve months and there was no antibacterial activity of diluted bee venom for S. aureus in twelve months, room temperature storage. 3. We could not observe the zone of inhibition around paper disc of all for E.coli. in 1:3,000, 1:30,000 and 1:3,000,000 diluted bee venom solution, respectively. According to results, we expect that diluted bee venom solution is stable both cold and room temperature storage within twelve months.

An Experimental Study on Generation and Measurement Method of EG/AD Model Ice at Cold Room for Improvement of Its Properties (EG/AD 모형빙 정도 향상을 위한 콜드룸에서의 생성기법 및 계측기법 연구)

  • Cho, Seong-Rak;Jeong, Seong-Yeob;Ha, Jung-Seok;Kang, Kuk-Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.6
    • /
    • pp.414-420
    • /
    • 2013
  • Generation and measurement methods of EG/AD model ice, which is used in KIOST ice model basin are investigated for improvement of its properties. Temperature of seed water, air temperature in the freezing phase and the target air temperature in the tempering phase were changed in the cold room, and the properties of model ice was measured in this conditions. We also verified a conventional measuring method of flexural strength of model ice caused a little measuring error in cold room, so that we suggested a new measuring method that must be used higher supports than double the thickness of the model ice. In this study, we improved the generation and measurement technique of EG/AD model ice, and the developed procedure at cold room can be applied to the KIOST ice model basin.

Effects of cold and room temperature storage on the sprouting and marketability of early-grown spring potatoes

  • Heon-Seop Won;Kyusuk Han;Young Hun Lee
    • Food Science and Preservation
    • /
    • v.31 no.1
    • /
    • pp.33-45
    • /
    • 2024
  • Three spring potato varieties (Atlantic, Chubaek, and Superior) were cultivated for 80, 90, and 100 days and compared in terms of their total and marketable yields and specific gravities. Subsequently, changes in the quality parameters (weight loss, sprouting rate, disease incidence, dry weight, and specific gravity) of potatoes cultivated for 100 days were monitored during two-month storage in improved and semi-underground warehouses at 4℃ and room temterature. The productivities of Atlantic, Superior, and Chubaek were maximized at cultivation periods of 100, 100, and >90 days, respectively. In all cases, cold storage resulted in <5.3% weight loss and no marketability loss. However, two-month room temperature storage resulted in pronounced marketability loss due to weight loss (6.2, 7.3% and 10.9% for Atlantic, Superior, and Chubaek, respectively) and sprouting (in ~13%, >75%, and 99% of Atlantic, Superior, and Chubaek tubers, respectively). The marketability of Atlantic, Superior, and Chubaek during cold storage was maintained for >2, ~2, and <2 months, respectively. All varieties were characterized by rapid sprouting, low dry weight and specific gravity, and rapid marketability loss during storage.

Comparative Assessment of Freshness Preservation in Vacuum-Packed Frozen Olive Flounder Paralichthys olivaceus and Mackerel Scomber japonicus Fillets During Room Temperature Distribution Using Varied Quantities of Commercially Available Cold Packs (시판 보냉팩 개수에 따른 진공포장 냉동 넙치(Paralichthys olivaceus) 및 고등어(Scomber japonicus) 필렛의 상온유통 중 선도유지능 비교평가)

  • So Hee Kim;Ji Un Lee;Eun Bi Jeon;Jin Kim;Pantu Kumar Roy;Shin Young Park;Jung-Suck Lee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.6
    • /
    • pp.818-825
    • /
    • 2023
  • The surge in online seafood consumption has increased parcel delivery, leading to a need to implement effective preservation methods. As the cold chain system is not fully established in Korea, styrofoam boxes and cold packs are commonly used for low-temperature seafood distribution. The impact of cold packs on product preservation depends on the number utilized. Herein, the freshness of vacuum-packed frozen fish fillets (Paralichthys olivaceus and Scomber japonicus) stored at 25±0.5℃ for up to 84 h was measured. Chemical (pH and volatile base nitrogen), microbiological (viable cell count), and physical (odor intensity) properties were assessed using 2 or 4 cold packs in a styrofoam box. Four cold packs yielded lower values, indicating superior freshness, and extended fish freshness by approximately 12 h compared with two cold packs. Therefore, it is recommended to use a minimum of 4 cold packs (-350 g/cold pack) in a styrofoam box for distributing approximately 300 g of frozen fish fillets at room temperature during the summer, considering an average delivery period of 2 days in Korea.

Changes in Onion (Allium cepa L.) Bulb Quality during Storage at Room Temperature and Greenhouse (비닐하우스를 이용한 양파의 상온 저장 중 품질 변화)

  • Ko, Eun Young;Hong, Sae Jin;Keum, Young Soo;Park, Se Won
    • Korean Journal of Plant Resources
    • /
    • v.25 no.5
    • /
    • pp.591-595
    • /
    • 2012
  • This study was conducted to investigate the possibility of changes in onion (cv. 'Turbo' and 'Changnyongdaego') bulb quality during storage at room and cold temperature. Increased weight loss was found in the onion bulb stored at both cold and room temperature conditions. 4% weight loss was found in bulbs stored at room temperature and 2% at cold storage as compared to fresh cultivated onion bulb; after three months. Initially, there was no significant difference in the firmness of bulbs between cultivars and storage conditions. Hunter a value of bulb stored at room temperature was higher than the value of bulb stored at cold temperature. 27% and 7.9% decay was found after three months in 'Changnyongdaego' and 'Turbo' cultivars stored under room temperature condition respectively. In contrast, only 2% decay was noticed in both cultivars stored at cold storage condition. Hunter L value of onion bulb gradually decreased in both room and cold temperature storage conditions. In conclusion, quality of onion bulb can be maintained until three months. For long term storage and quality maintenance, under room temperature conditions a resistance cultivar should be selected.

An Experimental Study for the Mechanical Properties of Model Ice Grown in a Cold Room (Cold Room을 이용한 모형빙의 재료특성에 관한 실험적 연구)

  • Kim, Jung-Hyun;Choi, Kyung-Sik;Jeong, Seong-Yeob;Seo, Young-Kyo;Cho, Seong-Rak;Lee, Chun-Ju
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.3
    • /
    • pp.64-70
    • /
    • 2008
  • A full-scale field experiment is an important part in the design of ships and offshore structures. Full-scale tests in the ice-covered sea, however, are usually very expensive and difficult tasks. Model tests in a refrigerated ice tank may substitute this difficulty of full-scale field tests. One of the major tasks to perform proper model tests in an ice towing tank is to select a realistic material for model ice which shows correct similitude with natural sea ice. This study focuses on the testing material properties and the selection of model ice material which will be used in an ice model basin. The first Korean ice model basin will be constructed at the Maritime & Ocean Engineering Research Institute (MOERI) in 2009. With an application to the MOERI ice model basin, in this study the material properties of EG/AD/S model ice of IOT (Institute for Ocean Technology) Canada, were tested. Through comprehensive bending tests, the elastic modulus and the flexural strength of EG/AD/S model ice were evaluated and the results were compared with published test results from Canada. Instead of using an ice model basin, a cold room facility was used for making a model ice specimen. Since the cold room adopts a different freezing procedure to make model ice, the strength of the model ice specimen differs from the published test results. The reason for this difference is discussed and the future development for a making model ice is recommended.