• Title/Summary/Keyword: Cold function test

Search Result 64, Processing Time 0.023 seconds

Comparative Study of Normal Group and Depression Group(pulmonary Function is Below Expected Value) by DSOM (폐기능검사상 기능저하군과 정상군의 한방변증 비교분석)

  • Kim, Jin-Young;Shin, Woo-Jin;Sim, Sung-Heum;Baek, Sang-In;Lee, Byung-Guon;Park, Dong-Il
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.3
    • /
    • pp.723-733
    • /
    • 2009
  • The purpose of this study is to evaluate the difference about pathogenesis of normal group and depression group(who' pulmonary function is below expected value). Author used DSOM to investigate oriental pathogenesis. Depression group is consisted of people who's FVC%(forced vital capacity)is below 80% or $FEV_1$/FVC%(Forced Expiratory Volume in 1sec/FVC) is below 70%, and they don't have history of lung disease(Athma, tuberculosis, COPD, suchlike). Normal group is consisted of people who's FVC%(Forced Vital Capacity) is in 80-120% and $FEV_1$/FVC%(Forced Expiratory Volume in 1sec/FVC) is above 70%. they also don't have history of lung disease. Author carried out each group's PFT(pulmonary function test) by ATS(American Thoracic Society) method. DSOM was used for oriental pathogenesis investigation of two groups. There was significant difference between normal group and depression group in Kidney(p<0.05). In depression group comparison of sex, there was significant difference between male and female in stagnation of qi, cold, heat, spleen, phlegm(p<0.05). In Normal group there was significant difference between male and female in stagnation of qi, blood stasis, cold, heat, spleen(p<0.05). In depression group comparison of smoke, there was no significant difference between smoker and non-smoker(p<0.05). In Normal group comparison of smoke, there was significant difference between smoker and non-smoker in heat(p<0.05). This result showed difference of the pathogenesis between Depression group and Normal group.

Flow Network Analysis for the Flow Control of a Main Cooling Water System in the HANARO Fuel Test Loop (하나로 핵연료 시험 루프 주냉각수 계통의 유량 제어에 대한 유동 해석)

  • Park, Young-Chul;Lee, Yong-Sub;Chi, Dae-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.5
    • /
    • pp.7-12
    • /
    • 2009
  • A nuclear fuel test loop(after below, FTL) is installed in the IRI of an irradiation hole in HANARO for testing the neutron irradiation characteristics and thermo hydraulic characteristics of a fuel loaded in a light water power reactor or a heavy water power reactor. There is an in-pile section(IPS) and an out-pile section(OPS) in this test loop. When HANARO is operated normally, the fuel loaded into the IPS has a nuclear reaction heat generated by a neutron irradiation. To remove the generated heat and to maintain the operation conditions of the test fuel, a main cooling water system(MCWS) is installed in the OPS of the FTL. The MCWS is composed of a main cooler, a pressurizer, two circulation pumps, a main heater, an interconnection pipe line and instruments. The interconnection pipeline is a closed loop which is connected to an inlet and an outlet of the IPS respectively. The MCWS is under a cold function test during a start-up period. This paper describes the system flow network analysis results of the flow control of a main cooling water system in the HANARO fuel test loop. It was confirmed through the results that the flow was met the system design requirements.

The flow characteristics of a Main Cooling Water System for Nuclear Fuel Test Loop Installed in HANARO (하나로 핵연료 시험루프의 주냉각수 계통 유동해석)

  • Park, Young-Chul;Lee, Young-Sub;Chi, Dai-Yong;Ahn, Seong-Ho;Kim, Yong-Ki
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.444-447
    • /
    • 2008
  • A nuclear fuel test loop (after below, FTL) is installed in IR1 of an irradiation hole in HANARO for testing neutron irradiation characteristics and thermo hydraulic characteristics of a fuel loaded in a light water power reactor (PWR) or a heavy water power reactor (CANDU). There is an in-pile section (IPS) and an out-pile section (OPS) in this test loop. When HANARO is normally operated, the fuel loaded in the IPS has a nuclear reaction heat generated by a neutron irradiation. To remove the generated heat and to maintain an operation condition of the test fuel, a main cooling water system (MCWS) is installed in the OPS of the FTL. The pump can not continuously suck a fluid and not pressurize the fluid during a cold function test. To verify the flow characteristics of the MCWS, a flow net work analysis has been conducted. When the higher elevation pipelines wholly filled with coolant, it was confirmed through the analysis results that the pump pressurized the coolant normally. And the analysis results described the system characteristics with operation temperature and pressure variation satisfactorily.

  • PDF

Experimental Study of the Role of Gas-Liquid Scheme Injector as an Acoustic Resonator in a Combustion Chamber

  • Kim Hak-Soon;Sohn Chae-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.896-904
    • /
    • 2006
  • In a liquid rocket engine, the role of gas-liquid scheme injector as an acoustic resonator or absorber is studied experimentally for combustion stability by adopting linear acoustic test. The acoustic-pressure signals or responses from the chamber are monitored by acoustic amplitude. Acoustic behavior in a rocket combustor with a single injector is investigated and the acoustic-damping effect of the injector is evaluated for cold condition by the quantitative parameter of damping factor as a function of injector length. From the experimental data, it is found that the injector can play a significant role in acoustic damping when it is tuned finely. The optimum tuning-length of the injector to maximize the damping capacity is near half of a full wavelength of the first longitudinal overtone mode traveling in the injector with the acoustic frequency intended for damping in the chamber. When the injector has large diameter, the phenomenon of the mode split is observed near the optimum injector length and thereby, the acoustic-damping effect of the tuned injectors can be degraded.

A Study on Thermal Environmental Performance Test of the Rotary Compressor Stirling Cryocooler (회전압축기형 스털링 냉동기의 열환경 성능시험에 관한 연구)

  • Park, Seong-Je;Hong, Yong-Ju;Kim, Hyo-Bong;Kimm, Dae-Woong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1953-1958
    • /
    • 2007
  • This paper presents the results of a series of performance tests for the integral Stirling cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate environmental specification. Integral Stirling cryocooler for thermal imaging system have matured to the stage of undergoing formal qualification test program. The thermal environmental test of the Stirling cryocooler is presented in this paper. We performed that low and high temperature keeping test from $-40^{\circ}C$ to $+71^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooldown time to 80K and steady state input power at 80K were determined as a function of cooler components temperatures at the compressor, hot end and cold tip. Tests performed on this cooler have been successful with a measured cooldown time to 80K of less than 5 minutes 24seconds for $71^{\circ}C$ ambient temperature with input power of 11W

  • PDF

Evaluation of Texture and Mechanical Property on Annealing Condition of Ni-Plated Hybrid Cu Sheet (어닐링처리에 따른 니켈 도금한 하이브리드 동판의 집합조직 및 기계적 특성평가)

  • Lee, Jung-Il;Lee, Joo-Ho;Cho, Kyung-Won;Kim, Kun-Nam;Kim, Gang-Beom;Jang, Tae-Soon;Park, No-Jin
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.21 no.3
    • /
    • pp.144-149
    • /
    • 2008
  • It has been reported that copper and copper alloys have a large anisotropy of functional properties such as electrical, thermal and mechanical properties, which means that the texture of polycrystalline alloy should be considered to achieve better properties. In this study, the determination of grain growth orientation and texture formation in the cold-rolled, heat-treated and Ni-plated hybrid copper sheets was investigated. Grain growth direction and texture formation were analyzed by the X-ray pole figure. The influence of texture on the mechanical properties could be quantitatively confirmed by the results from the orientation distribution function and the tensile test. The heat-treated texture in the cold-rolled hybrid copper sheet is also investigated and discussed.

Research on Development and Performance Evaluation for Thruster of Reaction Control System for KSLV-I (KSLV-I RCS 추력기 개발 및 수행 평가에 대한 연구)

  • Jeon, Sang-Woon;Jung, Seul
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.3
    • /
    • pp.19-27
    • /
    • 2010
  • KSLV(Korea Space Launch Vehicle)-I is designed as a launch vehicle to enter a 100 kg-class satellite to the LEO(Low-Earth Orbit). Attitude angles of the upper-stage, including roll, pitch and yaw are controlled by cold gas thruster system using nitrogen gas. The thruster for the KSLV-I is the main pneumatic valve in the RCS(Reaction Control System). In this paper, the design, function tests, and environment tests of the thruster for KSLV-I are described. The developed thrusters are experimentally evaluated and successfully passed the required qualification and acceptance tests.

Study of texture, mechanical and electrical properties of cold drawn AGS alloy wire

  • Zidani, M.;Bessais, L.;Farh, H.;Hadid, M.D.;Messaoudi, S.;Miroud, D.;Loudjani, M.K.;Helbert, A.L.;Baudin, T.
    • Steel and Composite Structures
    • /
    • v.22 no.4
    • /
    • pp.745-752
    • /
    • 2016
  • An investigation has been done to study the evolution of the microstructure, mechanical and electrical properties of AlMgSi alloy destined for the transport of electric energy, in function of the deformation caused by the cold drawing process. We identified that drawing of aluminum wire causes development of a fibrous texture of type <111> and <100>. We notice also that the electrical resistivity and mechanical resistance increases with the increasing of the deformation level. Characterization methods used in this work is: The Electron Back Scattered Diffraction EBSD, X-Ray diffraction, Vickers microhardness, Tensile test, Measuring electrical resistivity, the Scanning Electron Microscope (SEM) and Energy Diffraction Spectrum (EDS).

Design and test result of a superconducting double-spoke cavity

  • Jiang, Tiancai;Huang, Yulu;Zhang, Shengxue;Liu, Lubei;Xiong, Pingran;Li, Chunlong;Guo, Hao;Yue, Weiming;Zhang, Shenghu;He, Yuan
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.877-883
    • /
    • 2019
  • Superconducting multi-spoke cavities are outstanding alternative choice for acceleration of heavy ions in medium velocity regimes. Based on the scheme of China ADS, several researches on the superconducting double-spoke cavities were done and two prototype cavities have been developed. In this paper, the RF design, the mechanical design and fabrication considerations of the bare cavity will be described in detail. After Buffered Chemical Polishing and High Pressure Rinsing, one of the prototype cavities was installed into the Vertical Test Stand for high gradient RF testing at 4.2 K. The measurement results of the quality factor as a function of the accelerating field and the maximum surface field will be presented. An accelerating gradient of more than 15 MV/m is achieved during the test, with maximum surface electric field of 58 MV/m, and maximum surface magnetic field of 117 mT.

Changes in Acrosin Activity and Membrane Function of Boar Spermatozoa

  • Kim, C.K.;Kim, I.;Y.C. Chung;J.W. Ryu;H.J. Yoon;K. Kang;Kim, I.C.;Lee, J.H.;S.E. Yeon
    • Proceedings of the KSAR Conference
    • /
    • 2001.03a
    • /
    • pp.86-86
    • /
    • 2001
  • The aims of this work were to determine the acrosin activity and to evaluate the structural and functional integrity of AS boar spermatozoa. The acrosin activity of spermatozoa were 5.40, 4.10 and 3.40 mIU/10$^{6}$ sperm in raw, extended and frozen semen respectively , which differed significantly each other (P<0.05). After the raw and extended semen were exposured to cold and thermal shock, the acrosin activities of spermatozoa in the raw semen were 5.39, 5.21 and 5.29 mIU/10$^{6}$ sperm for control (non-shock), cold shock and thermal shock, and those of extended semen were 4.21, 3.98 and 4.00 mIU/10$^{6}$ sperm. This value among treatments did not differ significantly. The acrosin activities of spermatozoa in the extended and stored semen were 3.27, 3.52, 3.46 and 3.23 mIU/10/suup 6/ sperm, while hypo-osmotic test(HOST) values were 56.5%, 64.7%, 66.0% and 56.0%, following 4 days storage at 4$^{\circ}C$, 17$^{\circ}C$ , $25^{\circ}C$ and 37$^{\circ}C$, respectively. The results at 17$^{\circ}C$ and $25^{\circ}C$ appeared to be best compared with the other storage temperatures.

  • PDF