• 제목/요약/키워드: Cold flow

Search Result 1,092, Processing Time 0.025 seconds

Study on Spray Characteristics of GCSC Injector with Recess in High Pressure Condition (고압조건에서 기체-액체 분사기의 리세스에 따른 분무 특성 연구)

  • Kim, Jong-Gyu;Han, Yeoung-Min;Choi, Hwan-Seok;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.57-60
    • /
    • 2011
  • The spray characteristics according to the recess length of the GCSC injector and the change of momentum flux ratio(MFR) of the gas and the liquid have been examined through high pressure cold flow test using a high pressure chamber. The liquid in this experiment was water, and the gas was nitrogen. The spray images were taken by a back-lit strobe imaging technique. Results showed that the spray was a wide hollow cone at the lower MFR(liquid velocity was fixed) and the spray became a narrow solid cone as the MFR was increased. And the injector with short recess length produced a narrow solid cone at the higher MFR.

  • PDF

A Study on International Case and Application for Propulsion System Test Complex (추진기관 시스템 시험설비 개발을 위한 해외사례 분석 및 적용방안)

  • Park, Ju-Hyun;Park, Soon-Sang;Han, Yeoung-Min;Kim, Ji-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.96-99
    • /
    • 2012
  • The test facility for confirming performance of a propulsion system is essential infra-structure to develop launch vehicle system. Using the PSTC, cold flow and combustion tests are performed to the propulsion system of individual stage in launcher. Moreover the ground test for the total launching process is conducted. In order to construct the PSTC, we not only have surveyed technology of internal and external countries, but also actively use the case in terms of the system. The test facility consists of feeding system, test stand, control and measurement, and flame deflector.

  • PDF

An Experimental Study on the Cooling Characteristics of an Infrared Detector Cryochamber (적외선 센서용 극저온 용기의 냉각특성에 관한 실험적 연구)

  • Kang Byung Ha;Lee Jung Hoon;Kim Ho-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.889-894
    • /
    • 2004
  • Infrared (IR) detectors are widely used for many applications, such as temperature measurement, intruder and fire detection, robotics and industrial equipment, thermoelstic stress analysis, medical diagnostics, and chemical analysis. Quantum detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Thermal analysis of cryochamber includes the conduction heat transfer through a cold well, the gases conduction and gas outgassing, as well as radiation heat transfer, The transient cooling characteristics of an infrared detector cryochamber are investigated experimentally in the present study. The transient cooling load increases as the gas pressure is increased. Gas pressure becomes significant as the cooling process proceeds. Cool down time is also increased as the gas pressure is increased. It is also found that natural convection effects on cool down time become significant when the gas pressure is increased.

Experimental investigation of dew formation and heat transfer in the original upper structure of Sokkuram grotto (원형 석굴암 상부구조의 장마철 결로 및 열전달 현상의 실험적 연구)

  • 이진기;송태호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.588-597
    • /
    • 1999
  • Sokkuram grotto, a UNESCO cultural heritage in Kyongju Korea, was originally covered with crushed rocks over its dome with ventilating holes. The grotto was perfectly preserved for more than 12 centuries until the upper structure was replaced with a concrete dome in the early 20th century to protect from total collapse. Since then, heavy dew formed on the granite surface to seriously damage the sculptures until it was further remodeled with air-conditioning facilities in the 60s. It is considered that the original upper porous structure had a dehumidifying capability. This research is made to unveil the dehumidifying mechanism of the rock layer during the rainy season in that area. A rock layer and a concrete layer are tested in a temperature/humidity-controlled room. No dew formation is observed for the two specimen for continued sunny days or continued rainy days. However, heavy dew formed on the concrete surface for a sunny day after long rainy days. It is thought that the sun evaporates water on the ground and dew is formed at the surface as the highly humid air touches the yet cold concrete. On the contrary, no dew formation is observed for the rock layer at any time. Even in the above worst situation, air flows downward through the cool rock layer and moisture is removed before reaching inside. Temperature measurement, flow visualization, observation of dew formation and measurement of air velocity are made to verify the mechanisms.

  • PDF

Effect analysis of ISLOCA pathways on fission product release at Westinghouse 2-loop PWR using MELCOR

  • Kim, Seungwoo;Park, Yerim;Jin, Youngho;Kim, Dong Ha;Jae, Moosung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.2878-2887
    • /
    • 2021
  • As the amount of fission product released from ISLOCA was overestimated because of conservative assumptions in the past, several studies have been recently conducted to evaluate the actual release amount. Among several pathways for the ISLOCA, most studies were focused on the pathway with the highest possibility. However, different ISLOCA pathways may have different fission product release characteristics. In this study, fission product behavior was analyzed for various pathways at the Westinghouse two-loop plant using MELCOR. Four pathways are considered: the pipes from a cold leg, from a downcomer, from a hot leg to the outlet of RHR heat exchanger, and the pipe from the hot leg to the inlet of RHR pump (Pathway 1-4). According to the analysis results, cladding fails at around 2.5 h in Pathways 1 and 2, and on the other hand, about 3.3 h in Pathways 3 and 4 because the ISLOCA pathways affect the safety injection flow path. While the release amount of cesium and iodine ranges between 20 and 26% in Pathways 1 to 3, Pathway 4 allows only 5% to the environment because the break location is submerged. Also, as more than 90% of cesium released to the environment passes through the personnel door, reinforcing the pressure capacity of the doors would be a significant factor in the accident management of the ISLOCA.

Diffusion Simulation Using Envi-Met. in Urban Planetary Boundary Layer (Envi-Met.을 이용한 도심 대기경계층 내 확산장 변화 수치 모의)

  • Choi, Hyun-Jeong
    • Journal of Climate Change Research
    • /
    • v.7 no.3
    • /
    • pp.357-371
    • /
    • 2016
  • Buildings in the city acts as a cause of distorted wind direction, wind speed, causing the stagnation of the air flow. In the recent trend of climate change can not but consider the temperature rise of the urbanization. This study was aimed to analyze the thermal comfort of planetary boundary layer in different artificial constructions areas which has a direct impact on urban climate, and estimating the warming phenomena. Envi-met model was used to consider the urban structure associated with urban growth in order to precisely determine the impact of the building on the city weather condition. The analyzed values of thermal comfort index were temperature, wind speed, horizontal and vertical turbulent diffusivity. In particular, analysis of the PPD(Predicted Percentage of Dissatisfied) represents the human thermal comfort. In this study, by adjusting the arrangement and proportion of the top floor building in the urban it was found that the inflow of the fresh air and cooling can be derived low PPD. Vertical heat flux amount of the city caused by climate change was a factor to form a high potential temperature in the city and the accumulation of cold air does not appear near the surface. Based on this, to make the city effectively respond to climate change may require a long-term restructuring of urban spatial structure and density management.

Real operation of 2 kW class reverse-Brayton refrigeration system with using scroll compressor package

  • Kim, Hyobong;Yeom, Hankil;Choo, Sangyoon;Kim, Jongwoo;Park, Jiho;In, Sehwan;Hong, Yong-Ju;Park, Seong-Je;Ko, Junseok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.4
    • /
    • pp.40-44
    • /
    • 2020
  • This paper describes the real operation of 2 kW class reverse-Brayton refrigeration system with neon as a working fluid. The refrigeration cycle is designed with operating pressure of 0.5 and 1.0 MPa at low and high pressure side, respectively. Compressor package consists of several helium scroll compressors witch are originally used for driving GM cryocooler. Three segments of plate heat exchanger are adopted to cover the wide temperature range and the refrigeration power is produced by turbo expander. The developed refrigeration system is successfully operated at its target temperature of 77 K. In experiments, all parameters such as pressure, temperature, mass flow rate and valve opening are measured to investigate characteristics during cool-down process and normal state. The difference between design and real operation is discussed with measured experimental data. At normal state of 77 K operation, the developed reverse-Brayton refrigeration system shows 1.83 kW at 68.2 K of cold-end temperature.

A Study on the Yin-Yang Characteristics of Bland Taste (담미(淡味)의 음양(陰陽) 특성에 대한 고찰(考察))

  • Ahn, Jinhee
    • Journal of Korean Medical classics
    • /
    • v.35 no.2
    • /
    • pp.121-141
    • /
    • 2022
  • Objectives : This paper aims to examine the Yin-Yang characteristics of bland taste. Methods : Medicinals including bland taste were searched in herbology textbooks and mainly in the Bencaogangmu, of which major discourses were analyzed to examine the Yin-Yang characteristics of bland taste. Results & Conclusions : Most medicinals with bland taste were sweet-bland-cold, holding properties of cooling heat, stimulating urination and detoxification. These properties could be explained in relation to the Triple Burner's metabolism of Qi and fluids, as they stimulate perspiration and urination, improving the flow of fluids which in turn supports production of Original Qi, by working on the TB's Qi circulation system. In the bland taste discourse, it was understood that bland taste moves the Qi system and produces fluids, by first ascending then descending. Zhudanxi and the Neijing have opposing views on whether bland taste is Yin or Yang, but both saw blandness to have both Yin and Yang qualities. Characteristics of the bland taste could be better understood in relation to the Triple Burner. The phrase 'bland is attached to sweet taste[淡附于甘]' refers to the likeliness between the two tastes in that bland taste has the Central Earth qualities, integrating others and concealing itself in its blandness, its taste unspecific, mild and unstimulating thus communicating the Qi within the entire Triple Burner from Upper to Middle to Lower, as does sweet taste.

On the validation of ATHLET 3-D features for the simulation of multidimensional flows in horizontal geometries under single-phase subcooled conditions

  • Diaz-Pescador, E.;Schafer, F.;Kliem, S.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3567-3579
    • /
    • 2022
  • This paper provides an assessment of fluid transport and mixing processes inside the primary circuit of the test facility ROCOM through the numerical simulation of Test 2.1 with the system code ATHLET. The experiment represents an asymmetric injection of cold and non-borated water into the reactor coolant system (RCS) of a pressurized water reactor (PWR) to restore core cooling, an emergency procedure which may subsequently trigger a core re-criticality. The injection takes place at low velocity under single-phase subcooled conditions and presents a major challenge for the simulation in lumped parameter codes, due to multidimensional effects in horizontal piping and vessel arising from density gradients and gravity forces. Aiming at further validating ATHLET 3-D capabilities against horizontal geometries, the experiment conditions are applied to a ROCOM model, which includes a newly developed horizontal pipe object to enhance code prediction inside coolant loops. The obtained results show code strong simulation capabilities to represent multidimensional flows. Enhanced prediction is observed at the vessel inlet compared to traditional 1-D approach, whereas mixing overprediction from the descending denser plume is observed at the upper-half downcomer region, which leads to eventual deviations at the core inlet.

Effects of the Convector Plate Shape and the Atmospheric Gas on Characteristics of Heat Transfer in a Batch Annealing Furnace (BAF에서 분위기 가스와 대류판 형태가 열전달 특성에 미치는 영향)

  • Yoon, Soon Hyun;Kim, Moon Kyung;Kim, Dae Seong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.8
    • /
    • pp.72-79
    • /
    • 1996
  • In a BAF(Batch Annealing Furnace), various studies have been pursued in order to reduce energy consumption rate to improve productivity and to stabilize the properties of products. The purpose of this study was to investigate the effects of both the atmospheric gas and convector plate shapes on the augmentation of heat transfer. The use of hydrogen instead of nitrogen as an atmospheric gas, combined with high convection in the BAF, has shown that considerable increases in furnace out put and significantly improved material quality are attainable. Because convector plate shapes make the atmosheric gas easily flow density, high diffusivity and reducing character of hydrogen, a better heat transfer rates resulting in uniform material temperature distribution and improved coil surface quality can be achieved. Also, it was found that the closed convector plate took more time for the annealing cycle time than the other plate type(open-type)by about ten hours.

  • PDF