• 제목/요약/키워드: Cold flow

검색결과 1,090건 처리시간 0.031초

FTP-75 냉간 주행 모드로 운전하는 차량의 연료분사 모사시스템에 관한 연구 (A Study on the Fuel Injection System Simulating a Vehicle Driven with FTP-75 Mode for Cold Transition Period)

  • 오대산;이충훈
    • 한국분무공학회지
    • /
    • 제16권2호
    • /
    • pp.76-81
    • /
    • 2011
  • A fuel injection system which is operated with a real vehicle driving simulation was developed as an alternative to a vehicle test for the fuel injectors. The sensor signals that are supplied to the ECU were measured and recorded as a data file for a vehicle driven in FTP-75 mode in a chassis dynamometer. The imperative sensor signals of the throttle position, vehicle speed, engine speed, crank position, cam position, intake air flow, and cooling water and intake air temperature were reconstructed using FPGA DAQ boards and a PXI computer. The scanning results showed good agreement with the input signals that were reconstructed. The ECU HILS system operated successfully to drive six fuel injectors, which injected fuel in the same pattern as if they were mounted in the vehicle driven in FTP-75 mode. Also, the fuel injection system developed in this research shows the possibility of application in evaluating the characteristics of fuel injection rate for injectors according to properties of injected fuel with the real driving mode of vehicles.

Direct ECC Bypass Phenomena in the MIDAS Test Facility During LBLOCA Reflood Phase

  • B.J. Yun;T.S. Kwon;D.J. Euh;I.C. Chu;Park, W.M.;C.H. Song;Park, J.K.
    • Nuclear Engineering and Technology
    • /
    • 제34권5호
    • /
    • pp.421-432
    • /
    • 2002
  • As one of the advanced design features of the APR1400, direct vessel injection (DVI) system is being considered instead of conventional cold leg injection (CLI) system. It is known that the DVI system greatly enhances the reliability of the emergency core cooling (ECC) system. However, there is still a dispute on its performance in terms of water delivery to the reactor core during the reflood phase of a large-break loss-of-coolant accident (LOCA). Thus, experimental validation is under progress. In this paper, test results of direct ECC bypass performed in the steam-water test facility tailed MIDAS (Multi-dimensional Investigation in Downcomer Annulus Simulation) are presented. The test condition is determined, based on the preliminary analysis of TRAC code, by applying the ‘modified linear scaling method’with the l/4.93 length scale . From the tests, ECC direct bypass fraction, steam condensation rate and information on the flow distribution in the upper annulus downcomer region are obtained.

동해의 해수 순환에 대한 Numerical Modelling 연구 -I. 폐쇄해역으로 가정한 경우 (Numerical Study of the Circulation in the Japan Sea -I. Case of Closed Basin)

  • 김영의;정종률
    • 한국해양학회지
    • /
    • 제24권2호
    • /
    • pp.96-108
    • /
    • 1989
  • 동해의 해수 순환에 영향을 주는 요인들 가운데 대기와의 열 염교환과 바람에 대한 순환계의 반응을 Semtner(1974)의 3차원 수치모델을 이용하여 규명하였다. 동해와 북태평양을 연결하는 해협을 막아 유출입이 배제된 상태에서 구해진 한국 동안을 따라 북상하는 흐름과 동해 북동부의 반시계방향 순환 등의 표층 해수 순환은 Uda(1934) 및 Naganuma(1972)에 의한 해류모식도와 유사하다. 또한 100-200m 층에서 Kim and Kim(1983)이 지적한 북한한류와 비슷한 남향류가 한국 동안을 따라 나타났고, 동해 고유냉수가 형성되는 것과 유사한 형태로 동해 북동부 해역에서 상대적으로 고염인 해수의 침강현상이 나타났다.

  • PDF

KSLV-I RCS 충전모사 시스템 개발 (Development of the Gas Charging Simulator for Reaction Control System of KSLV-I)

  • 전상운;정슬;김지훈
    • 항공우주기술
    • /
    • 제8권2호
    • /
    • pp.122-126
    • /
    • 2009
  • KSLV-I은 100kg급 소형 인공위성을 지구 저궤도에 진입시키는 임무를 수행하여야 하며, 이를 위해 상단의 3축 자세제어를 위한 자세제어 시스템이 요구된다. 추력기 노즐을 통해 질소가스를 방출함으로써 발생하는 작용 반작용 모멘트를 제어모멘트로 사용하는 냉가스 추력기 자세제어 시스템을 KSLV-I 상단의 3축 자세제어 시스템으로 선정하였다. 충전 시스템의 유량 검증 및 충전 시나리오 작성을 위해 지상 충전 시스템 개발 전단계로 충전모사 시스템의 개발이 필요하다. 본 논문에서는 KSLV-I 충전 모사 시스템의 오리피스 설계, 시스템 개발, 충전 시험에 관한 것이다.

  • PDF

화력발전용 가스재열기의 응력 해석 (Stress Analysis of Gas-Gas Heater in Thermal Power Plant)

  • 황석환;최재승;이후광
    • 한국정밀공학회지
    • /
    • 제19권1호
    • /
    • pp.204-211
    • /
    • 2002
  • Today\`s industrialized plants are required to reduce SOx emitted from stacks at factories, utility power stations, etc. For this purpose, flue gas desulfurization(FGD) system is installed in thermal power plant and gas-gas heater(GGH) is used to play a vital role to reheat the wet treated gas from FGD. The sector plates are located at cold and hot sides of gas-gas heater. They serve as sealing to prevent mixing treated and untreated gases. Therefore, the deformation of the sector plate due to its dead weight and gas pressure should be considered as major factor for the sector plate design. And finite element analysis(FEA) for rotor part in GGH is performed with original model and two weight-reduced models with different diaphragm thickness, respectively. Stress concentrations at rotor diaphragm happen due to the dead weight, pressure difference between treated and untreated gas, and thermal distribution in the rotor. As the thickness of diaphragm is decreased, the stress level is increased. The direction of treated gas and untreated gas flow may affect the stress level.

GA 강판에 대한 $CO_2$ 수직용접자세의 특성에 관한 연구 (A study on the characteristics of vertical welding positions using GA steel sheet in the $CO_2$ welding)

  • 김재성;조용준;이경철;이보영
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2007년 추계학술발표대회 개요집
    • /
    • pp.36-38
    • /
    • 2007
  • The instability of the arc in the $CO_2$ arc welding affects the quality of the weld in the automotive industry. This paper evaluates the effects of the arc stability in $CO_2$ arc welding with respect to vertical welding positions. In this experiment, galva-annealed steel sheets(CA) were used as specimens, and these materials were welded by adopting new Cold Metal Transfer (CMT) process. For each sample, fillet joint welding trials were carried out using the same conditions. Each part of welding joints was welded with vertical-up, vertical-down position at $45^{\circ},\;90^{\circ}\;and\;135^{\circ}$ degrees. A high speed camera and a welding signal monitoring system were used for monitoring fluid-flow phenomena in weld pools and frequency measurements, respectively. Through this study, the welding position were found to be key factors mainly to influence the arc stability in $CO_2$ welding moreover and that the arc stability in the vertical-up welding position was observed to be more stable than the vertical-down welding position below $90^{\circ}$.

  • PDF

원전 혼합배관 고주기 열피로 평가방법론의 적용성 평가 (Applicability Evaluation of Methodology for Evaluating High Cycle Thermal Fatigue of a Mixing Tee in Nuclear Power Plants)

  • 김선혜;성희동;최재붕;허남수;박정순;최영환
    • 한국압력기기공학회 논문집
    • /
    • 제7권4호
    • /
    • pp.44-50
    • /
    • 2011
  • Turbulent mixing of hot and cold coolants is one of the possible causes of high cycle thermal fatigue in piping systems of nuclear power plants. A typical situation for such mixing appears in turbulent flow through a T-junction. Since the high cycle thermal fatigue caused by thermal striping was not considered in the piping fatigue design in several nuclear power plants, it is very important to evaluate the effect of thermal striping on the integrity of mixing tees. In the present work, before conducting detailed evaluation, three thermal striping evaluation methodology suggested by EPRI, JSME and NESC are analyzed. Then, a by-pass pipe connected to the shutdown cooling system heat exchanger is investigated by using these evaluation methodology. Consequently, the resulting thermal stresses and the fatigue life of the mixing tee are reviewed and compared to each other. Futhermore, the limitation of each methodology are also presented in this paper.

국산과 중국산 형개의 Pulegone함량분석 (Quantitative Analysis of Pulegone in Schizonepeta tenuifolia Briq.)

  • 김호경;이아영;이혜원;천진미;최지현;신자원;고병섭
    • Applied Biological Chemistry
    • /
    • 제49권2호
    • /
    • pp.125-128
    • /
    • 2006
  • Schizonepeta tenuifolia Briq. are used in folk medicine as common cold, sore throat, headache and skin infection in Korea, China and Japan. To compare the contents of domestic and Chinese Schizonepeta tenuifolia quantitative HPLC analysis was performed using a Luna $C_{18}$ column $(4.6{\times}250\;mm,\;5{\mu}m)$, with 1 ml/min of flow rate of 0.01% formic acid in water : acetonitrile = 50 : 50 under UV 254 nm of detector. Pulegone was detected at retention time of about 17.14 min.

마이크로컴퓨터를 이용한 가솔린 기관용 전자제어장치의 개발에 관한 연구 (A Study on the Development of an Electronic Control Unit for a Gasoline Engine using Microcomputer)

  • 김태훈;조진호
    • 한국자동차공학회논문집
    • /
    • 제3권6호
    • /
    • pp.224-237
    • /
    • 1995
  • An ECU(Electronic Control Unit) with 16 bit microcomputer has been developed. This system includes hardware and software for more precise control on fuel injection, ignition timing, and idle speed. This control system employs an air flow sensor of the hot wire type, a direct ignition system, an idle speed control system using a solenoid valve, and a crank angle sensor. Especially, the crank angle sensor provides two separate signals: One is the position signal(POS) which indicates 180 degree pulses per revolution, and the other is the reference signla(REF) that represents each cylinder individually. The conventional engine control system requires at least two engine revolutions in order to identify the cylinder number. However, the developed engine control system can recognize the cylinder number within a quarter of an engine revolution. Therfore, the developed engine control system has been able to control fuel injection and ignition timing more quickly and accurately, Furthermore, the number of misfire reduces during the cold start.

  • PDF

지역냉방 시스템용 판형 열교환기의 주름높이에 따른 열전달 및 압력강하 특성 (Heat Transfer and Pressure Drop Characteristic of Plate Heat Exchanger with Corrugation Height for District Cooling System)

  • 권오경;김현중
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.23-29
    • /
    • 2011
  • The objectives of this paper are to study the characteristics of heat transfer and pressure drop of the plate heat exchanger with corrugation height by numerical analysis. Plate heat exchanger of three types was designed, which was corrugation height 3.1mm, 2.8mm and 2.5mm. The plate heat exchanger was numerically investigated for Reynolds number in a range of 950~3,380. The temperatures of the hot side were performed at $14.5^{\circ}C$ while that of the cold side was conducted at $4.5^{\circ}C$. The results show that the performance of heat transfer coefficient for corrugation height 2.5mm increases about 9.5~17.1% compared to that of corrugation height 3.1mm. On the other hand, the performance of pressure drop for corrugation height 2.5mm is remarkably higher than that of corrugation height 3.1mm, about 65.7~86.0%.