• Title/Summary/Keyword: Cold box

Search Result 130, Processing Time 0.024 seconds

Experimental Study on Adfreeze Bond Strength Between Frozen Sand and Aluminium with Varying Freezing Temperature and Vertical Confining Pressure (동결온도와 수직구속응력 변화에 따른 모래와 알루미늄 재료의 접촉면에서 작용하는 동착강도 실험 연구)

  • Ko, Sung-Gyu;Choi, Chang-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.9
    • /
    • pp.67-76
    • /
    • 2011
  • Bearing capacity of pile foundations in cold region is dominated by adfreeze bond strength between surrounding soil and pile perimeter. Adfreeze bond strength is considered to be the most important design parameter for foundations in cold region. Many studies in last 50 years have been conducted to analyze characteristics of adfreeze bond strength. However, most studies have been performed under constant temperature and normal stress conditions in order to analyze affecting factors like soil type, pile material, loading speed, etc. In this study, both freezing temperature and normal stress acting on pile surface were considered to be primary factors affecting adfreeze bond strength, while other factors such as soil type, pile material and loading speed were predefined. Direct shear box was used to measure adfreeze bond strength between Joomoonjin sand and aluminium because it is easy to work for various roughness. Test was performed with temperatures of > $0^{\circ}C$, $-1^{\circ}C$, $-2^{\circ}C$, $-5^{\circ}C$, and $-10^{\circ}C$ and vertical confining pressures of 1atm, 2atm, and 3atm. Based on the test results, the effects of temperature and vertical stress on adfreeze bond strength were analyzed. The test results showed that adfreeze bond strength increases with decreased temperature and increased vertical stress. It was also noted that two types of distinct sections exist, owing to the rate of increase of adfreeze bond strength along the change of freezing temperature: 1)rapidly increasing section and 2)gradually decreasing section. In addition, the results showed that a main factor affecting adfreeze bond strength switches from friction angle to adhesion as freezing temperature decreases.

Studies on the CA Storage of Sweet Persimmon in Polyethylene Film Pack (Polyethylene film포장(包裝)에 의(依)한 단감의 CA저장(貯藏)에 관(關)한 연구(硏究))

  • Min, Byong-Yong;Oh, Sang-Lyong
    • Korean Journal of Food Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.128-134
    • /
    • 1975
  • For development of long-term storage method of sweet-persimmons using polyethylene film bags, basic experiment was conducted with 30 boxes of sweet-persimmons in 1973 and the same experiment was extended for industrial application with 2,500 boxes of the persimmons in the cold storage of Jinyoung Sweet-persimmon Association in 1974. Investigation was made on change of the quality by storage period. At the same time, persimmons put in the cold storage test were shipped to market at different time in order to monitor consumer response and commercial feasibility. The followings are conclusion obtained from the result of this experiment. 1. Storage of sweet-persimmon, Buyu, produced in Jinyoung, Kimhae was possible for 1 month at $2^{\circ}C{\pm}1^{\circ}C$ cold storage. This storage period was extended to 4 months until the end of February in case that the fruits were hermetically sealed in P.E. film bags of 0.08 to 0.1 mm thickness. 2. During the storage period of sweet-persimmons packed in the film bags, the loss of weight due to evaporation was effectively prevented with use of the film of bag thicker than 0.04 mm. 3. The storage ability of 3-5 persimmons per small bag was somewhat superior to that of many persimmons packed in the large box of 15kg capacity. 4. The thicker the film of bags, the more $CO_2$ gas was accumulated inside, however, from 1 month after beginning of the storage the rate of $CO_2$ accumulation became very low maintaining the stabilized level of 5-6% at the plot of 0.06-0.08mm thick bags. 5. While the persimmons were in storage, decreased was the content of total sugars, total acids, and vitamin C, of which the phenomenon was remarkable especially with the fruits of non-packed plot. 6. The sweet-persimmons in the film bags subjected to cold storage when shipped to market in their intact condition were more beneficial than when they were shipped out in unpacked condition. The intact fruits packed in the P.E. film bags were able to keep their commercial value for 10days in the outdoor situation. 7. The sweet-persimmons that were packed in the film bags and put in the cold storage had maintained promissing marketability and the economic feasibility was acknowledged when the experimental practice was applied to industrial scale.

  • PDF

HEAT PIPE TYPE EXHAUST HEAT RECOVERY SYSTEM FOR HOT AIR HEATER

  • Kang, G.C.;Kim, Y.J.;Ryou, Y.S.;Rhee, K.J.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.654-661
    • /
    • 2000
  • Area of greenhouse increases rapidly up to 45,265ha by the year of 1998 in Korea. Hot air heater with light oil combustion is the most common heater for greenhouse heating in the winter season. However, exhaust gas heat discharged to atmosphere through chimney reaches up to 10~20% of total heat of the oil combusted in the furnace. In order to recapture the heat of this exhaust gas and to recycle for greenhouse heating, the heat pipe type exhaust heat recovery system was manufactured and tested in this experiment. The exhaust heat recovery system was made for space heating in the greenhouse. The system consisted of a heat exchanger made of heat pipes, ${\emptyset}15.88{\times}600mm$ located in the rectangular box of $600{\times}550{\times}330mm$, a blower and air ducts. The rectangular box was divided by two compartments where hot chamber exposed to exhaust gas in which heat pipes could pick up the heat of exhaust gas, and by evaporation of the heat transfer medium in the pipes it carries the heat to the cold compartment, then the blower moves the heat to greenhouse. The number of heat pipe was 60, calculated considering the heat exchange amount between flue gas and heat transfer capacity of heat pipe. The working fluid of heat pipe was acetone because acetone is known for its excellent heat transfer capacity. The system was attached to the exhaust gas path. According to the performance test it could recover 53,809 to 74,613kJ/hr depending on the inlet air temperature of 12 to $-12^{circ}C$ respectively when air flow rate $1,100\textrm{m}^3/hr$. The exhaust gas temperature left the heat exchanger dropped to $100^{circ}C$ from $270^{circ}C$ by the heat exchange between the air and the flue gas, the temperature difference was collected by the air and the warm air temperature was about $60^{circ}C$ at the air flow rate of $1,100\textrm{m}^3/hr$. This heat pipe type exhaust heat recovery system can reduce fuel cost by 10% annually according to the economic analysis.

  • PDF

Analysis of ZjWRKY3, ZjWRKY7 induced by multiple stress in Zoysia japonica (다양한 스트레스에 유도되는 들잔디 ZjWRKY3, ZjWRKY7의 분석)

  • Kim, Woo-Nam;Song, In-Ja;Kang, Hong-Gyu;Sun, Hyeon-Jin;Yang, Dae-Hwa;Lee, Yong-Eok;Kwon, Yong-Ik;Lee, Hyo-Yeon
    • Journal of Plant Biotechnology
    • /
    • v.44 no.3
    • /
    • pp.220-228
    • /
    • 2017
  • Many crops including cereals, tuber crops, feeds, and turf grasses are often damaged by various environmental stresses such as drought, salt, cold, and high temperature, causing the reduction of their productivity. Plants are sessile and cannot escape from environmental stresses. Thus, plants evolve in the direction of overcoming the environmental stresses. Some plant genes such as ARF, ABI3, NAC, HSF, and WRKY are known to respond to environmental stresses as they transcriptionally regulate the stress response pathways. For example, the OsWRKY76 gene contributes to the enhanced resistance to low temperatures and pathogenic infections. The AtWRKY28 also plays a role in environmental stresses. Zoysiagrass (Zoysia japonica Steud.) is popularly grown for gardens and golf courses. However, the function of the WRKY gene, another environmental stress-related gene, is not known in zoysiagrass. In this study, the ZjWRKY3 and ZjWRKY7 genes with one shared WRKY domain have been isolated in zoysiagrass. The expression of these genes increased in response to low temperature, drought, and salt stresses. Furthermore, the infection of the brown patch-causing Rhozoctonia solani induced the expression of ZjWRKY3 and ZjWRKY7. The corresponding proteins bind to the W-box of the Zjchi promoter, possibly regulating their transcriptions. The researchers suggest that the ZjWRKY3 and ZjWRKY7 genes transcriptionally regulate abiotic and biotic stress related downstream genes.

Construction and Assembly of KSTAR Current Leads and the Helium Control System (KSTAR 전류인입선 및 헬륨냉매 제어시스템 제작 및 설치)

  • Song, N.H.;Woo, I.S.;Lee, Y.J.;Kwag, S.W.;Bang, E.N.;Lee, K.S.;Kim, J.S.;Jang, Y.B.;Park, H.T.;Hong, J.S.;Park, Y.M.;Kim, Y.S.;Choi, C.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.5
    • /
    • pp.388-396
    • /
    • 2007
  • KSTAR (Korea Superconducting Tokamak Advanced Research) current lead system (CLS) has a role to interconnect magnet power supply (MPS) in room temperature (300 K) and superconducting (SC) bus-line, electrically. For the first plasma experiments, it should be assembled 4 current leads (CL) on toroidal field (TF) current lead box (CLB) and 14 leads on poloidal field (PF) CLB. Two current leads, with the design currents 17.5 kA, and SC bus-lines are connected in parallel to supply 35 kA DC currents on TF magnet. Whereas, it could supply $20\;{\sim}\;26\;kA$ to each pairs of PF magnets during more than 350 s. At the cold terminals of the leads, there are joined SC bus-lines and it was constructed helium coolant control system, aside from main tokamak system, to protect heat flux through current leads and enhanced Joule heat due to supplied currents. Throughout the establishment processes, it was tested the high vacuum pumping, helium leak of the helium lines and hardwares mounted between the helium lines, flow controls for CL, and liquid nitrogen cool-down of possible parts (current leads, CL helium lines, and thermal shield helium lines for CLB), for the accomplishment of the required performances.

Explainable Artificial Intelligence (XAI) Surrogate Models for Chemical Process Design and Analysis (화학 공정 설계 및 분석을 위한 설명 가능한 인공지능 대안 모델)

  • Yuna Ko;Jonggeol Na
    • Korean Chemical Engineering Research
    • /
    • v.61 no.4
    • /
    • pp.542-549
    • /
    • 2023
  • Since the growing interest in surrogate modeling, there has been continuous research aimed at simulating nonlinear chemical processes using data-driven machine learning. However, the opaque nature of machine learning models, which limits their interpretability, poses a challenge for their practical application in industry. Therefore, this study aims to analyze chemical processes using Explainable Artificial Intelligence (XAI), a concept that improves interpretability while ensuring model accuracy. While conventional sensitivity analysis of chemical processes has been limited to calculating and ranking the sensitivity indices of variables, we propose a methodology that utilizes XAI to not only perform global and local sensitivity analysis, but also examine the interactions among variables to gain physical insights from the data. For the ammonia synthesis process, which is the target process of the case study, we set the temperature of the preheater leading to the first reactor and the split ratio of the cold shot to the three reactors as process variables. By integrating Matlab and Aspen Plus, we obtained data on ammonia production and the maximum temperatures of the three reactors while systematically varying the process variables. We then trained tree-based models and performed sensitivity analysis using the SHAP technique, one of the XAI methods, on the most accurate model. The global sensitivity analysis showed that the preheater temperature had the greatest effect, and the local sensitivity analysis provided insights for defining the ranges of process variables to improve productivity and prevent overheating. By constructing alternative models for chemical processes and using XAI for sensitivity analysis, this work contributes to providing both quantitative and qualitative feedback for process optimization.

A Study on Effective Width of Press-Braked Steel Plates with a Free Edge (둥근 모서리를 갖는 절곡 자유돌출판의 유효폭 분석)

  • Choi, Byung Ho;Cho, Kwang Il;Kim, Tae Bong
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.5
    • /
    • pp.355-363
    • /
    • 2016
  • This study numerically investigates buckling behavior of press braked steel plates with a free edge that consists of the upper flange of U-shaped box girder. Since the press-braked plates include a rounded edge, the effective width to thickness ratio of the press-braked upper flange is obscure to determine the nominal compressive strength. This study performed 3D finite element analyses to evaluate an equivalent effective width of cold-formed plate with a free edge. Through the parametric numerical analyses, the elastic buckling stresses of the rounded corner plates were compared with those of general flat plates and then, the equivalent effective width has been estimated. A comparative study with Euler buckling formula speculated in the domestic design specifications has been conducted.

Coupling of Electromagnetic and Electrostatic Waves in Inhomogeneous Plasmas

  • Kim, Kyung-Sub;Kim, Eun-Hwa;Lee, Dong-Hun
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.82-82
    • /
    • 2003
  • It is well known that electromagnetic (EM) waves are mode converted to electrostatic (ES) waves in inhomogeneous plasmas. We examine this issue in a three-dimensional multi-fluid numerical model. First, we derive a set of coupled linear wave equations when a one-dimensional inhomogeneous density profile is assumed in a cold and collisionless plasma. The massive ions are considered as fixed because we are interested in high frequency waves in plasmas. It is shown that the EM mode satisfies the 0th order modified Bessel equation near the resonant region where the frequency matches the local electron plasma frequency. It is expected that the EM waves are coupled and damped to the ES waves owing to the logarithmic singular behavior at such resonances. Second, we numerically test the same case in a 3-D multi-fluid model. An impulsive input is assumed to excite EM waves in the inhomogeneous 3-D box model. The wave spectra of electric and magnetic fields are presented and compared with the analytical results. Our results suggest that the EM energy is irreversibly converted into the ES energy wherever the resonant condition is satisfied. Finally we discuss how the mode conversion appears in both electric and magnetic fields by analyzing time histories of each component. We also compare our results with MHD wave coupling. It is numerically confirmed in this study that the coupling of EM and ES waves is similar to that of compressional and transverse MHD waves.

  • PDF

THERMAL DESIGN OF A PROTOMODEL SPACE INFRARED CRYOGENIC SYSTEM (적외선 우주망원경 냉각시스템 시험모델 열설계)

  • Yang Hyung-Suk;Kim Dong-Lak;Lee Byoung-Seob;Kim Geon-Hee;Lee Dae-Hee;Pak Soo-Jong;Nam Uk-Won
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.2
    • /
    • pp.153-160
    • /
    • 2006
  • A Protomodel Space Infrared Cryogenic System (PSICS) cooled by a stirling cry-ocooler has been designed. The PSICS has an IR sensor inside the cold box which is cooled by a stirling cryocooler with refrigeration capacity of 500mW at 80K in a vacuum vessel. It is important to minimize the heat load so that the background thermal noise can be reduced. In order to design the cryogenic system with low heat load and to reduce the remained heat load, we have performed numerical analyses. In this paper, we present the design factors and the results obtained by the thermal analysis of the PSICS.

Cooling performance test of the superconducting fault current limiter

  • Yeom, H.;Hong, Y.J.;In, S.;Ko, J.;Kim, H.B.;Park, S.J.;Kim, H.;Kim, H.R.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.4
    • /
    • pp.66-70
    • /
    • 2014
  • The superconducting fault current limiter (SFCL) is an electrical power system device that detects the fault current automatically and limits the magnitude of the current below a certain safety level. The SFCL module does not have any electrical resistance below the critical temperature, which facilitates lossless power transmission in the electric power system. Once given the fault current, however, the superconducting conductor exhibits extremely high electrical resistance, and the magnitude of the current is accordingly limited to a low value. Therefore, SFCL should be maintained at a temperature below the critical temperature, which justifies the cryogenic cooling system as a mandatory component. This report is a study which reported on the cooling system for the 154 kV-class hybrid SFCL owned by Korea Electric Power Corporation (KEPCO). Using the cryocooler, the temperature of liquid nitrogen (LN2) was lowered to 71 K. The cryostat was pressurized to 5 bars to improve the dielectric strength of nitrogen and suppress nitrogen bubble foaming during operation of SFCL. The SFCL module was immersed in the liquid nitrogen of the cryostat to maintain the superconducting state. The performance test results of the key components such as cryocooler, LN2 circulation pump, cold box, and pressure builder are shown in this paper.