• 제목/요약/키워드: Cold and hot energy

검색결과 231건 처리시간 0.026초

국의 온도가 공복감, 열량 및 영양소 섭취량에 미치는 영향 (Effects of Soup Temperature on Hunger, Energy and Nutrient Intake)

  • 김석영;장희애;김주영;박경민
    • Journal of Nutrition and Health
    • /
    • 제36권8호
    • /
    • pp.859-869
    • /
    • 2003
  • The purpose of this study was to compare the effects of soup temperature on hunger, energy, and nutrient intake. The hot meal consisted of 400 g of hot beef-vegetable soup (75$^{\circ}C$), Yubu Chobap, Bulgogi, cucumber pickle and radish pickle. The cold meal component were the same as the hot meal except 300 g of water (8$^{\circ}C$) and boiled vegctables (100 g), instead of the hot beef-vegetable soup ot the hot meal. Thirst, core temperature and blood pressure were also measured before and after consumption the test meals in a within-subjects, repeated measures design. 30 women consumed 17% more kilocalories, 13% more protein and lipid and 16% more carbohydrate in the cold meal than in the hot meal. The core temperature at the end of the test meal was higher in the hot meal than in the cold meal. Energy and nutrient intake were inversely correlated with the hunger scores within 1 hour after the hot meal, however those are not related with each other in the cold meal. So hunger feeling might be disturbed in the cold meal. It is concluded that energy and nutrient consumptions were higher in the cold meal, partly because of the distrubed hunger feeling in the cold meal.

열전소자가 적용된 냉·온수 매트용 전열 모듈의 기초 열설계에 관한 수치해석적 연구 (Numerical Analysis on the Thermal Design of a Heat Exchanger for a Cold & Hot Water Mattress Equipped with Thermoelectric Modules)

  • 양호동;박설현
    • 한국기계가공학회지
    • /
    • 제20권3호
    • /
    • pp.113-121
    • /
    • 2021
  • In this study, the thermal characteristics of cold and hot water mattress units equipped with thermoelectric modules were investigated via numerical analyses. Cold and hot water mattress products that are currently in existence use manual methods requiring refrigerants to be added to the hot water boiler. However, the cold and hot water mattress units using thermoelectric modules can provide improved efficiency via energy savings and actively resolving environmental pollution problems. To determine the efficiency of the thermoelectric module, the mattress was modeled and its efficiency was analyzed for the cooling and heating processes using two 100-W-class and one 200-W-class thermoelectric modules, respectively. From the results of this study, it was confirmed that when two 100-W-class modules were used, the application area was larger than when a single 200-W-class module was used, with uniform temperature distribution and improved performance compared to existing products in terms of electrical energy.

환기량의 주거건물 냉난방에너지 소비에 대한 영향 : 미국 한랭기후 및 고온다습기후의 단독주택을 중심으로 (Ventilation Rate Impact on Heating and Cooling Energy Consumption in Residential Buildings : Concentrated on a Detached House in Cold and Hot/Humid Climatic Zones of USA)

  • 문진우
    • 설비공학논문집
    • /
    • 제23권11호
    • /
    • pp.747-753
    • /
    • 2011
  • The purpose of this study was to quantify the impact of the ventilation rate on heating and cooling energy consumption in a detached house. For it, a series of simulations for the application of the diverse ventilation rate (ACH) were computationally conducted for a prototypical detached residential building in the cold climate (Detroit, Michigan) and hot/humid climate (Miami, Florida) of USA. Analysis revealed that ventilation is a significant heat losing source in the cold climate; thus, the higher ventilation rate significantly increases the heating energy consumption and energy cost in the cold climate; while the impact on energy increase for heating and cooling energy consumption is similar in hot/humid climate with less significancy compared to cold climate. The research outcome of this study could be a fundamental data for determining the optimal ventilation rate in terms of indoor air quality, but also building energy performance well.

Design and Exergy Analysis for a Combined Cycle of Liquid/Solid $CO_2$ Production and Gas Turbine using LNG Cold/Hot Energy

  • Lee, Geun-Sik
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권1호
    • /
    • pp.34-45
    • /
    • 2007
  • In order to reduce the compression power and to use the overall energy contained in LNG effectively, a combined cycle is devised and simulated. The combined cycle is composed of two cycles; one is an open cycle of liquid/solid carbon dioxide production cycle utilizing LNG cold energy in $CO_2$ condenser and the other is a closed cycle gas turbine which supplies power to the $CO_2$ cycle, utilizes LNG cold energy for lowering the compressor inlet temperature, and uses the heating value of LNG at the burner. The power consumed for the $CO_2$ cycle is investigated in terms of a solid $CO_2$ production ratio. The present study shows that much reduction in both $CO_2$ compression power (only 35% of the power used in conventional dry ice production cycle) and $CO_2$ condenser pressure could be achieved by utilizing LNG cold energy and that high cycle efficiency (55.3% at maximum power condition) in the gas turbine could be accomplished with the adoption of compressor inlet cooling and regenerator. Exergy analysis shows that irreversibility in the combined cycle increases linearly as a solid $CO_2$ production ratio increases and most of the irreversibility occurs in the condenser and the heat exchanger for compressor inlet cooling. Hence, incoming LNG cold energy to the above components should be used more effectively.

EGR Cooler 대체용 Vortex Tube의 에너지 분리 현상에 관한 실험적 연구 (Experimental Study on the Energy Separation of the Vortex Tube for EGR Cooler)

  • 김창수;박성영
    • 한국산학기술학회논문지
    • /
    • 제11권1호
    • /
    • pp.55-60
    • /
    • 2010
  • 고압의 가스를 이용하여 고온 가스와 저온 가스를 분리하거나 입자상 물질의 분리에 사용 할 수 있는 장치인 볼텍스 튜브의 에너지 분리 특성을 적용하여 자동차의 EGR Cooler 대체장치의 기본 설계 자료를 구축하기 위하여 실험을 수행하였다. 설계를 위한 기초 자료를 확보하기 위하여, 볼텍스 튜브의 입구 압력, 저온출구 및 고온출구압력 변화에 따른 에너지 분리 특성을 분석하였다. 공급압력이 상승할수록 에너지 분리 효과가 상승하였으며, 최고온도는 저온유량비가 약 0.85 에서, 최저온도는 저온유량비가 약 0.35 에서 발생하였다. 볼텍스 튜브의 고온측 출구온도는 고온측 및 저온측 출구압력에 영향을 받으며, 저온측 출구온도는 출구압력 변화에 독립적인 온도변화 특성을 나타내었다. 본 연구의 결과는 자동차의 EGR Cooler 대체장치의 기본 설계 자료로 응용될 수 있을 것이다.

Analysis of energy and daylight performance of adjustable shading devices in region with hot summer and cold winter

  • Freewan, Ahmed A.;Shqra, Lina W.
    • Advances in Energy Research
    • /
    • 제5권4호
    • /
    • pp.289-304
    • /
    • 2017
  • Large glazed surfaces and windows become common features in modern buildings. The spread of these features was influenced by the dependence of designers on mechanical and artificial systems to provide occupants with thermal and visual comfort. Countries with hot summer and cold winter conditions, like Jordan, require maximum shading from solar radiation in summer, and maximum exposure in winter to reduce cooling and heating loads respectively. The current research aims at designing optimized double-positioned external shading device systems that help to reduce energy consumption in buildings and provide thermal and visual comfort during both hot and cold seasons. Using energy plus, a whole building energy simulation program, and radiance, Lighting Simulation Tool, with DesignBuilder interface, a series of computer simulations for energy consumption and daylighting performance were conducted for offices with south, east, or west windows. The research was based on comparison to determine the best fit characteristics for two positions of adjustable horizontal louvers on south facade or vertical fins on east and west facades for summer and winter conditions. The adjustable shading systems can be applied for new or retrofitted office or housing buildings. The optimized shading devices for summer and winter positions helped to reduce the net annual energy consumption compared to a base case space with no shading device or with curtains and compared to fix shading devices.

자동변속기용 부품의 에너지 절감을 위한 최적 설계 연구 (A Study on the Optimum Design for Energy Saving of an Auto Transmission Part)

  • 이학선;김태형;김선현;홍의창;이정환
    • 소성∙가공
    • /
    • 제24권3호
    • /
    • pp.181-186
    • /
    • 2015
  • Many in the industrial world that consume high amounts of energy are trying to reduce energy when manufacturing their products. Energy saving during manufacturing is a cost reduction. Reduced cost is necessary for profit improvement. The Piston Under Drive Brake used in the current study is an automotive transmission part. The original machining after hot forging was changed to machining after cold forging of a plate in order to save energy and cost. Two extrusion shapes along the outer diameter caused decreased tool life because of the interrupted cut during turning. Therefore, a thickness reduction of two extrusion areas in the outer diameter was needed. The current study suggests an effective way to reduce the thickness of interrupted cut by using progressive blanking.

데이터센터의 냉방에너지 절감을 위한 냉각시스템 분석 및 개선 방안 (Analysis and Improvement of Cooling System for Energy Saving in Data Center Building)

  • 장용호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.314-319
    • /
    • 2011
  • Energy Cost has been rapidly increased with the internal heat gain of data center to keep the temperature condition. But the cooling units for server systems are fully operated to satisfy the indoor temperature condition, it results in the excessive energy consumption. In this study, various cooling systems were studied for data center and cold aisle containment system was proved to be the best solution for server cooling system. Because it protects the cooling zone from the hot aisle space. Effective cooling and prohibition of recirculation air from hot aisle was possible by the cold aisle containment system.

  • PDF

An Experimental Study on the Mass and Energy Release for a Hot Leg Break LBLOCA During Post Blowdown

  • S.J. Hong;Kim, J.H.;Park, G.C.
    • Nuclear Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.108-127
    • /
    • 2000
  • Hot leg break LBLOCA(Large Break LOCA) had a potential to be a containment maximum pressure accident in YGN3&4, which was induced from excessive conservatism in the CE analysis methodology of mass and energy release. This study conducted mass and energy release experiment for the hot leg break LBLOCA during post blowdown with an integral test facility, SNUF(Seoul National University Facility). This facility simulated YGN 3&4 with volume ratio of 1/1140 based on Ishii's three level scaling. Experiment showed that SI(Safety Injection) water refilled cold leg first and core later. SI water was vaporized in the core, which resulted in the repressurization of reactor. This increase of pressure drove the water in cold leg to flow up half height of U tubes. However, since the water was drained back soon, the release through the SG side broken section by evaporation was negligibly small. This study also provided experimental assessment of RELAP5 results by KAERI for the release through the SG side broken section.

  • PDF

Compressional MHD wave transport in the boundary region between cold and hot plasmas

  • Park, Seong-Kook;Lee, Dong-Hun;Kim, Ki-hong
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2003년도 한국우주과학회보 제12권2호
    • /
    • pp.40-40
    • /
    • 2003
  • When the magnetotail is disturbed by an impulsive input such as the substorm onset, compressional magnetohydrodynamic (MHD) waves play an important role in delivering perturbed energy and exciting various wave modes and currents. The plasmasheet, in which relatively hot plasmas exist, is surrounded by relatively cold plasmas at the plasma sheet boundary layer (PSBL) and the equatorial plasmasphere. Since the Alfven speed significantly varies near these regions, the compressional waves are expected to undergo mode conversion by inhomogeneity at the boundary between cold and hot plasma regions. We investigate how the initial compressional MHD wave energy is reflected, transmitted, and absorbed across that boundary by adopting the invariant imbedding method (IIM) which gives the exact reflection, transmission, and absorption coefficients without any theoretical approximations for given frequencies and wave numbers. The IIM method is very useful in quantifying the reflection and transmission of compressional waves in the sense that we can calculate how much fast mode wave energy is delievered into shear Alfven waves or field-aligned currents. Our results show that strongly localized absorption occurs at the boundary region. This feature suggests that localized field-aligned currents can be impulsively excited at such boundary regions by any compressional disturbances, which is highly associated with impulsive auroral brightening at the substorm onset. We compare our results with previous studies in cold inhomogeneous plasmas.

  • PDF