• Title/Summary/Keyword: Cold Surface Temperature

Search Result 641, Processing Time 0.036 seconds

Atmospheric Characteristics of Fog Incidents at the Nakdong River : Case Study in Gangjeong-Goryeong Weir (낙동강 유역 안개 발생시 기상 특성: 강정고령보 사례를 중심으로)

  • Park, Jun Sang;Lim, Yun-Kyu;Kim, Kyu Rang;Cho, Changbum;Jang, Jun Yeong;Kang, Misun;Kim, Baek-Jo
    • Journal of Environmental Science International
    • /
    • v.24 no.5
    • /
    • pp.657-670
    • /
    • 2015
  • Visibility and Automatic Weather System(AWS) data near Nakdong river were analyzed to characterize fog formation during 2012-2013. The temperature was lower than its nearby city - Daegu, whereas the humidity was higher than the city. 157 fog events were observed in total during the 2 year period. About 65% of the events occurred in fall (September, October, and November) followed by winter, summer, and spring. 94 early morning fog events of longer than 30 minutes occurred when south westerly wind speed was lower than 2 m/s. During these events, the water temperature was highest followed by soil surface and air temperatures due to the advection of cold and humid air from nearby hill. The observed fog events were categorized using a fog-type classification algorithm, which used surface cooling, wind speed threshold, rate of change of air temperature and dew point temperature. As a result, frontal fog observed 6 times, radiation 4, advection 13, and evaporation 66. The evaporation fog in the study area lasted longer than other reports. It is due to the interactions of cold air drainage flow and warm surface in addition to the evaporation from the water surface. In particular, more than 60% of the evaporation fog events were accompanied with cold air flows over the wet and warm surface. Therefore, it is needed for the identification of the inland fog mechanism to evaluate the impacts of nearby topography and land cover as well as water body.

Correlations of Frost Properties Considering the Environmental Parameters over a Cold Flat Plate (수평편판에서의 착상인자를 고려한 서리 물성치의 상관식)

  • Lee, Kwan-Soo;Kim, Yong-Chul;Jhee, Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.8
    • /
    • pp.1046-1052
    • /
    • 2001
  • This study has been performed experimentally to measure the frost properties over a cold flat plate in order to obtain the correlations of the frost properties with various environmental parameters. Correlations of the frost surface temperature, thickness, density, and thermal conductivity are presented along with the experimental results as a function of environmental parameters, distance from the leading edge of test plate, and time. These correlations can be used to predict the frost properties with a maximum error of 8% in the following ranges : air temperature 15∼25$\^{C}$, relative humidity 60∼80%, air velocity 1∼3m/s and cooling plate temperature -15∼-25$\^{C}$.

A Study on the Internal Temperature Reduction of PKG-A Water-jet-room by Substituting Heat Insulation Materials (단열재 개선을 통한 PKG-A Water Jet Room 온도저감 연구)

  • Jung, Young In;Choi, Sang Min
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.3
    • /
    • pp.425-435
    • /
    • 2019
  • Purpose: The purpose of this study was to resolve the Naval ship's Local Operation Panel(LOP) malfunction problems which caused by overheating in summer season and dispatching to equatorial regions. Methods: Instead of using dual type heat insulation materials(consist with ceramic wool and glass wool), aerogel heat insulation materials were used for decreasing heat emissions from gas-turbine heat waste steam pipes passing water-jet- room. Experiment and Computational analysis of heat flow were conducted to analyze the internal room temperature changes. Results: The results of this study are as follows; The aerogel heat insulation materials suppress heat emission more efficiently than dual type insulation materials. The cold surface temperature of insulation was far more decreased and internal room, LOP surface temperature also showed significant results too. Conclusion: The substituted heat insulation materials appeared remarkable performance in decreasing room temperature that it could be used for suppressing the LOP overheatings and malfunctions.

The cold water mass along the southeast and east coasts of Korea in 2016-2017

  • Choo, Hyo-Sang
    • Fisheries and Aquatic Sciences
    • /
    • v.24 no.7
    • /
    • pp.243-259
    • /
    • 2021
  • The spatial and temporal behaviors and fluctuations of the cold water that appeared in the South East Sea and the East Sea coast from 2016 to 2017 were investigated. The water temperature drop was large in the east coast from April to June and the southeast coast from July to September, and the temperature drop period was longer in the southeast coast. The water temperature fluctuated sensitively to the wind direction, and it gradually decreased in the southwest wind but rose as if jumping in the northeast wind. Wind stress and surface water temperature had an inverse correlation, which was larger in Bukhang-Idukseo, and decreased toward the north of Guryongpo. The cold water appeared mainly in Geojedo-Pohang after 1 to 2 days when the southwest wind was strong, but when the wind became weak, it shrank to the Idukseo (Ulgi-Gampo) and extended into the open sea in a tongue shape. Cold water was distributed only in Samcheok-Toseong in mid-May, Idukseo-Guryongpo and Hupo-Jukbyeon-Samcheok from late May to mid-July, and Bukhang-Idukseo in August-September. The intensity of cold water was greatest in mid-August, and the center of cold water descended from the east coast to the southeast coast from spring to summer. The water temperature fluctuation was dominant at the periods of 1 d and 7-21 d. In wavelet spectrum analysis of water temperature and wind, wind speed increase-water temperature decrease showed phase difference of 12 h in 2 d, 18 h in 3 d, 1.5 d in 4-8 d, and 2-3 d in 8-24 d period. The correlation between the two parameters was large in Geojedo and Namhang, Bukhang-Idukseo, Guryongpo-Jukbyeon, and Samcheok-Toseong. Monitoring stations with high correlation in all periods were generally parallel to the monsoon direction.

The Comparison and Distribution of Temperatures Established in Display Stands and Food Surfaces for Cold and Frozen Foods in large Discount Stores in Korea (대형할인매장에서의 냉장.냉동식품 판매대의 설정온도와 판매식품 표면온도 비교 및 온도분포 분석)

  • Choi, Moon-Sil;Choi, Jeong-Ae;Kim, Mee-Hye;Bahk, Gyung-Jin
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.4
    • /
    • pp.308-314
    • /
    • 2011
  • This study surveyed and compared the temperatures established in display stands and food surfaces for cold and frozen foods in large discount stores in Korea. The temperatures established in display stands for cold food ranged with $3.5{\pm}1.8^{\circ}C$ as mean, minimum and maximum were $0^{\circ}C$ and $7^{\circ}C$. However, the surface temperatures of cold food on sale ranged with $10.7{\pm}2.9^{\circ}C$ as a mean, minimum $4.6^{\circ}C$ and maximum $18.4^{\circ}C$. Totally, the surface temperature of cold food on sale was $7.2^{\circ}C$, as a mean, higher than established in display stands for cold food in large discount stores in Korea. 53% of the surveyed cold foods were more than $10^{\circ}C$ in surface temperature and only 47% was less than $10^{\circ}C$. The differences between temperatures were lowest in fruits, salads and vegetables, but highest in milk products. On the other hand, the temperatures established in display stands for frozen food showed a range with $-20.7{\pm}1^{\circ}C$ as a mean. However, the surface temperatures of frozen food on sale showed a range with $-15.4{\pm}5^{\circ}C$ as a mean, minimum $-28^{\circ}C$ and maximum $-4.6^{\circ}C$ (included defrosting). The surface temperatures of frozen food, frozen meats, frozen processed foods and ice creams were $-13.8^{\circ}C$, $-15.9^{\circ}C$, and $-16.8^{\circ}C$, respectively. Only 32.3% of surveyed frozen foods showed less than $-18^{\circ}C$ in surface temperature. In conclusion, the temperatures established on cold and frozen food display stands were less than those of cold and frozen food surfaces on sale. There was also much variation in food surface temperatures during cold and frozen food storage and sales. Therefore, a temperature management system technology use at the distribution level for cold and frozen foods will be developed.

Nature of Cold Injury and Resistance in Wheat and Barley (맥류의 한해와 내동성에 관하여)

  • 남윤일;연규복;구본철
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.34 no.s02
    • /
    • pp.96-114
    • /
    • 1989
  • There are several meterorolgical stresses in the winter cereal crops. Among these stresses, cold injury is one of the most important stresses for wheat and barley production in Korea. The reduction in grain yield of the wheat and barley due to cold injury has occurred almost every year in Korea. The objective of the study was to get the basic information in relation to the cold injury and to detect the method minimizing the damage of cold injury. When the air temperature was the ranges of -13$^{\circ}C$ to -15$^{\circ}C$, the soil temperature at the crown part of the plant was very stable, whereas in the ranges of -2$^{\circ}C$ to -3$^{\circ}C$ the soil surface temperature was more unstable and cold than air and subterranean temperatures. The different parts of the plant in wheat and barley possess the different levels of cold hardiness. In comparison to the cold hardiness of plant parts, the leaf and crown are the less sensitive to cold injury than root and vascular transitional zone. The type and extent of stress is determined by the redistribution pattern of water during freezing. These types from freezing processes were three types: a) Equilibrium freezing pattern b) Non -equilibrium freezing pattern, c) Non-equilibrium freezing pattern typical of tender tissues. Cold hardiness in wheat plants were more harder than barley plants at vegitative stage, but inverted at the reproductive stage. Injuries by low temperature during the seasons of barley cultivation in Korea were occured mainly in four stage; in the first and third stage, frost injury occurs, the second stage, freezing injury, and the fourth stage, chilling injury.

  • PDF

Climate change in Korea inferred from subsurface temperatures (한국의 지중온도를 이용한 기후변화연구)

  • Lee, Young-Min;Kim, Hyoung-Chan;Song, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.442-444
    • /
    • 2006
  • On long time scale and over large areas ground surface temperatures (GSTs) track surface air temperatures (SATs). Additionally, GST changes penetrate into the subsurface and are recorded as transient temperature perturbation to the background thermal filed. Therefore, climate change can be reconstructed from borehole temperature measurements We present GST hi story reconstructed from temperature measurements in a borehole at Pocheon The result shows that GST cold period in the late 19th century and then increased by about 2K to 1990. GST history matches well with surface air temperatures measured from 1907 to 2001 at the Seoul Meteorological Station and GST history reconstructed from temperature measurements in three boreholes at Ulsan.

  • PDF

Characteristics of Water Temperature Inversion Observed in a Region West of Jeju Island in April 2015 (2015년 4월에 제주 서부해역에서 발생한 수온역전층 특성)

  • Kim, Seong Hyeon
    • Ocean and Polar Research
    • /
    • v.42 no.2
    • /
    • pp.97-113
    • /
    • 2020
  • In-situ observations were carried out in April 2015 to investigate the occurrence of water temperature inversion in a region west of Jeju Island. Analysis of in-situ in the western part of Jeju island showed that cold water moved to the southeast from the surface to the middle layer and warm water moved from the middle to the lower layer of the northwest direction. The water temperature inversion occurred at 84 stations (63.1%) out of 133 stations. At the boundary of the water temperature inversion layer, it was formed in the middle layer and disappeared. In the strongly appearing, it started from the middle layer to the lower layer. The shape of the water temperature inversion layer was different. As a result of horizontal water temperature slope analysis of the water temperature inversion zone, maximum 0.23℃/km was obtained and the mean was 0.06℃/km. The role of water temperature inversion as an indicator to determine the formation of water front. As a result of the water mass analysis, Jeju Warm Current Water and Tsushima Warm Current Water of high temperature and high salt intruded from the middle to the bottom. In the middle layer occurred as the Yellow Sea Cold Water of low water temperature and low salinity expanded.

Automated Cold Volume Calibration of Temperature Variation in Cryogenic Hydrogen Isotope Sorption Isotherm (극저온(20K) 수소동위원소 흡착 등온선의 온도 변화에 대한 자동 저온 부피 교정)

  • Park, Jawoo;Oh, Hyunchul
    • Korean Journal of Materials Research
    • /
    • v.29 no.5
    • /
    • pp.336-341
    • /
    • 2019
  • The gas adsorption isotherm requires accurate measurement for the analysis of porous materials and is used as an index of surface area, pore distribution, and adsorption amount of gas. Basically, adsorption isotherms of porous materials are measured conventionally at 77K and 87K using liquid nitrogen and liquid argon. The cold volume calibration in this conventional method is done simply by splitting a sample cell into two zones (cold and warm volumes) by controlling the level sensor in a Dewar filled with liquid nitrogen or argon. As a result, BET measurement for textural properties is mainly limited to liquefied gases (i.e. $N_2$ or Ar) at atmospheric pressure. In order to independently investigate other gases (e.g. hydrogen isotopes) at cryogenic temperature, a novel temperature control system in the sample cell is required, and consequently cold volume calibration at various temperatures becomes more important. In this study, a cryocooler system is installed in a commercially available BET device to control the sample cell temperature, and the automated cold volume calibration method of temperature variation is introduced. This developed calibration method presents a reliable and reproducible method of cryogenic measurement for hydrogen isotope separation in porous materials, and also provides large flexibility for evaluating various other gases at various temperature.