• Title/Summary/Keyword: Cold Chamber

Search Result 278, Processing Time 0.023 seconds

Effect and Safety of Oxygen Chamber Therapy on Cold Hypersensitivity: A Randomized, Controlled Trial (냉증에 대한 산소챔버의 임상 효능 및 안전성 연구)

  • Ha, Hun-Yong;Yoon, Dal-Hwan;Go, Ho-Yeon;Han, Yong-Dae;Kim, Nam-Sik;Nam, Eun-Young;Kim, Hyung-Jun
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.26 no.4
    • /
    • pp.123-139
    • /
    • 2013
  • Purpose: Cold hypersensitivity is regarded to be associated with blood circulation. This study is aims to evaluate the effects and safety of oxygen chamber therapy on cold hypersensitivity by comparing the temperature and Visual Analogue Scale. Methods: 42 outpatients who visited ${\bigcirc}{\bigcirc}$ University Oriental Hospital from July 11th, 2013 to August 28th, 2013 were analyzed. Patients were subjected to thermometer, and those with thermal difference greater than $0.3^{\circ}C$ between upper arm and palm and also with more than VAS 4 of cold hypersensitivity were diagnosed with cold hypersensitivity. 42 outpatients diagnosed with cold hypersensitivity are divided into two groups, one is the experimental group consisted of 21 patients and other was control group consisted of 21 patients. The experimental group had oxygen chamber therapy 10 times for 4 weeks. Thereafter the effects of oxygen chamber therapy on cold hypersensitivity was analyzed with t-text using SPSS for Windows version 21. Results: After the oxygen chamber therapy, experimental group had considerable improvement on cold hypersensitivity, in consequence of decreasing rate of thermal difference and VAS of cold hypersensitivity. Ear deafness and hand numbness were reported as an adverse effects in experimental group, but there was no serious adverse effects. Conclusions: This clinical trial showed oxygen chamber therapy could be effective and safe to reduce cold hypersensitivity.

INVESTIGATION OF THE CNS HOLE SHAPE AND A PROPOSED INSTALLATION METHOD FOR A VACUUM CHAMBER FOR THE HANARO REACTOR

  • Cho Yeong-Garp;Kim Young-Ki;Lee Kye-Hong;Choung Yun-Hang
    • Nuclear Engineering and Technology
    • /
    • v.38 no.5
    • /
    • pp.455-458
    • /
    • 2006
  • The HANARO reactor has a vertical hole for a cold neutron source (CNS) in the heavy-water reflector tank, i.e., the CNS hole, which was considerably deformed during its welding to the horizontal cold neutron (CN) beam tube. This paper presents an investigation of the form of the CNS hole for the optimal design of the a vacuum chamber for the CNS. In addition, the installation method of the vacuum chamber into the CNS hole for minimizing the water thickness between the vacuum chamber and the nose of the CN beam tube is proposed.

Cold Flow and Ignition Tests for Technology Demonstration Model of 75-Tonf Thrust Chamber (75톤급 연소기 기술검증 시제 수류시험 및 점화시험)

  • Kim, Mun-Ki;Han, Yeoung-Min;Kim, Jong-Gyu;Ahn, Kyu-Bok;Lee, Kwang-Jin;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.97-100
    • /
    • 2009
  • Cold flow and ignition tests were performed for a technology demonstration model of a 75-tonf thrust chamber which is a candidate liquid rocket engine for a next Korea Space Launch Vehicle. The test facility was modified to support the new concepts of the thrust chamber such as ignition system, film cooling and LOx leading supply. The hydrodynamic characteristics of the supply pipelines, thrust chamber and igniter as well as the filling time of the propellants were obtained through the cold flow tests on the LOx and kerosene and the ignition cyclogram was determined using the results. The ignition test was successfully accomplished according to the cyclogram and therefore, a basic information was obtained for further hot firing tests.

  • PDF

The Effect of a Vortex Chamber Diameter Ratio on Energy Separation (보텍스 생성실 지름비가 에너지 분리에 미치는 영향)

  • 유갑종;이병화;최인수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.667-673
    • /
    • 2001
  • As an alternative cooling method to reduce environmental hazard, vortex tubes have been studied for energy separation into cold and hot streams. Hence, the experiments were carried out systematically to find the best ratio of vortex chamber diameter to tube diameter. Also, the work was don to investigate how inlet pressure and geometric ratios of vortex tube affected temperature differences at tow needs as ell as cooling capacity and cooling efficiency. The result showed that the maximum temperature differences at the both ends and the maximum cooling efficiency were obtained when the ratio of vortex chamber diameter was about 1.45, while the inlet pressure ws not higher than 0.7 MPa.

  • PDF

The Origin and Daily Dose of Allii Chinensis Bulbus in Treatise on Cold Damage Diseases and Synopsis of Prescriptions of the Golden Chamber (상한론(傷寒論)과 금궤요략(金匱要略)의 해백(薤白) 기원종과 1일 복용량)

  • Kim, In-Rak
    • The Korea Journal of Herbology
    • /
    • v.32 no.1
    • /
    • pp.41-45
    • /
    • 2017
  • Objectives : The purpose of this study was to assume the origin and daily dose of Allii Chinensis Bulbus in Treatise on Cold Damage Diseases and Prescriptions of the Gold Chamber. Methods : I assumed the origin with Book of Materica Medica such as Illustration and Classic of Materia Medica(本草圖經), Illustration and Consideration of Plant's Name and Reality(植物名實圖考), The Korean Herbal Pharmacopoeia Forth Edition, Annotation of Hangeul Treatise of Cold Damages Diseases, and daily dose based on general principle applied on dose of Treatise on Cold Damage Diseases. Results : In Treatise on Cold Damage Diseases and Prescriptions of the Gold Chamber, the original species of Allii Chinensis Bulbus was Allium chinense G. Don. It was to be measured with weight. It was too big to write on size due to it's 10~30mm length and 3~12mm in diameter. And due to irregular size, it can't be written on number, too. Daily dose of Allii Chinensis Bulbus in Whaeyeok-san(回逆散), Gwalluhaebaekbanha-tang(栝樓薤白半夏湯) was 3 Ryang(兩), which was the most common case in Treatise on Cold Damage Diseases. And that in Gwalluhaebaekgyeji-tang(栝樓薤白桂枝湯), Gwalluhaebaekbaekju-tang(栝樓薤白白酒湯) is 8 Ryang(兩), which was the largest dose as dried herb in Treatise on Cold Damage Diseases Conclusions : The original species of Allii Chinensis Bulbus was Allium chinense G. Don. The daily dose of Allii Chinensis Bulbus was 3 Ryang(兩)(19.5g) in Whaeyeok-san and Gwalluhaebaekbanha-tang, and was 8 Ryang(兩)(52g) in Gwalluhaebaekgyeji-tang and Gwalluhaebaekbaekju-tang.

Design of Oxygen Chamber System for Diagnosis and Treatment of Cold Hypersensitivity (냉증을 진단하고 치료하는 산소챔버 시스템의 설계)

  • Cho, Myeon-Gyun;Choi, Hyo Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.6013-6021
    • /
    • 2012
  • Although there are many patients who suffer from cold hypersensitivity and have a difficult time in living daily lives due to feeling cold at room temperature, it is about true that an accurate diagnostic method and an effective remedy for a cold hypersensitivity have not been developed yet. Therefore, in order to develop traditional medicine equipment for cold hypersensitivity, we have designed new oxygen chamber system which can diagnose cold hypersensitivity with multiple bionic sensors and supply a patient optimum amount of oxygen adaptively to the extent of their illness. In particular, diverging from conventional diagnosis based on the experience of doctor and subjective statements of patient, we introduced accurate method for diagnosis in comparing between output of multiple sensors and threshold derived from clinical trials. After all, the proposed oxygen chamber system will contribute to achieving scientific evidence and manufacturing of korean traditional medicine.

Cold Flow and Ignition Tests for a 75-tonf Kerosene-Cooled Liquid Rocket Engine Thrust Chamber (75톤급 액체로켓엔진 케로신 냉각 연소실 수류시험 및 점화시험)

  • Kang, Dong-Hyuk;Lim, Byoung-Jik;Ahn, Kyu-Bok;Seo, Seong-Hyeon;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.25-28
    • /
    • 2010
  • The Cold flow and ignition tests have been performed for a technology demonstration model of 75-tonf liquid rocket engine thrust chamber which was designed and manufactured on the basis of the previous development experience of a 30-tonf liquid rocket engine thrust chamber. The hydrodynamic characteristics of the facility supply pipelines and the filling time of the cooling kerosene were obtained through the cold flow tests. The ignition cyclogram was determinded using the results and the ignition test was successfully carried out. The acquired data and test technique of present ignition test will be used in hot firing tests.

  • PDF

Investigation of Small Current Interruption Performance for New Type of Interrupting Chamber in SF$_{6}$ Gas Circuit Breaker (신차단방식 SF$_{6}$ 가스 차단기의 소전류 차단성능 연구)

  • Song, Won-Pyo;Kweon, Ki-Yeoung;Lee, Jae-Sung;Song, Ki-Dong;Kim, Maeng-Hyun;Ko, Hee-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.11
    • /
    • pp.519-526
    • /
    • 2005
  • This paper presents computer simulation results for developing new type of SF$_{6}$ Circuit Breaker in terms of cold gas flow after small current interruption. This cold gas flows down a nozzle into the chamber of a circuit breaker. There are many difficult problems in analyzing the gas flow due to complex geometry, moving boundary, shock wave and so on. When predicting the dielectric capability of a gas circuit breaker after interruption, the gas pressure and density distributions due to the cold gas must be considered in addition to the electrical field imposed across the gas. A self-coded computational fluid dynamics (CFD) program is used for the simulation of cold gas flow in order to evaluate the electrical field characteristic across open contacts and transient characteristics of insulations after small current interruption.

Scale-up of Melting Chamber for a Pyrolysis Melting Incinemtion System (폐기물 열분해/용융 소각 시스템의 용융로 Scale-up 연구)

  • Yang, Won;Kim, Bong-Keun;Yu, Tae-U;Jeun, Keum-Ha
    • 한국연소학회:학술대회논문집
    • /
    • 2007.05a
    • /
    • pp.168-175
    • /
    • 2007
  • Ash melting chamber is one of the key facility of the pyrolysis-melting incineration system, and it should be designed and operated very carefully for avoiding solidification of slag. In this study, an example of numerical and experimental scale-up process of the melting chamber, in which high speed air is injected to the molten slag and generates bubbles, which enhances agitation of the slag and char combustion, is presented. Cold flow test, combustion and melting test in a lab-scale (30 kg/hr) chamber and a pilot scale (200 kg/hr) chamber. Minimum energy for maintaining molten slag is derived, and it was found that the molten slag can be maintained efficiently by concentrating heat into the bubbling slag.

  • PDF

Fuel-Side Cold-Flow Test and Pressure Drop Analysis on Technology Demonstration Model of 75 ton-class Regeneratively-Cooled Combustion Chamber (75톤급 재생냉각 연소기 기술검증시제 연료 수류시험 및 차압 해석)

  • Ahn, Kyu-Bok;Kim, Jong-Gyu;Lim, Byoung-Jik;Kim, Mun-Ki;Kang, Dong-Hyuk;Kim, Seong-Ku;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.807-812
    • /
    • 2011
  • Fuel-side cold-flow tests were performed on the technology demonstration model of a 75 ton-class liquid rocket engine combustion chamber for the first stage of the Korea space launch vehicle II. Pressure drop in the cooling channels of the combustion chamber was measured by changing fuel mass flow rate through a pressure regulating system. Pressure drop in each segment of the chamber could be obtained and a lot of pressure drop was caused by high flow velocity in the nozzle throat segment. The accuracy of a hydraulic analysis method for calculating a pressure loss in cooling channels could be verified by applying it to the cold-flow test conditions.

  • PDF