• Title/Summary/Keyword: Cold Air Distribution

Search Result 149, Processing Time 0.027 seconds

Process Design of Pulley for Automobile Airconditoner in Cold Forging (자동차 냉방기용 내부 풀리의 냉간 단조 공정 설계)

  • 김동진;정덕진;김병민;최재찬
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.4
    • /
    • pp.199-206
    • /
    • 1997
  • The inner pulley is an automobile component used as air conditioner clutch assembly. In cold forging of inner pulley, the design requirements are to keep the same height of the inner rib and outer one, and to make uniform the hardness distribution in the forged product. In industry, the design of forging processes is performed based on experience-oriented technology, that is, designers experience and expensive trial and error. Using the rigid-plastic finite element simulations. we design the optimal process conditions, which has a preforming operation. Also the final product configuration of forging has to be designed again in view of metal flow involved in the operation, derived from the finite element simulations. The forged pulley is investigated by checking the hardness distribution and it is noted that distribution has improved to be even and high enough for industrial application.

  • PDF

The numerical model for predicting frost layer growth (서리층 성장 예측을 위한 수치적 모델)

  • Lee, K.S.;Jhee, S.;Lee, T.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.249-258
    • /
    • 1997
  • In this study, a numerical model for analyzing frost formation phenomena on a cold flat plate has been developed. Both regions of air flow and frost layer have been coupled to calculate the amount of the heat and mass transfer between air flow and frost layer. Experiments have been also conducted to validate the numerical model. The present numerical results show a good agreement with the experimental data. The present numerical model also provides some useful data such as the temperature distribution inside the frost layer which could not be obtained through the experiments.

  • PDF

An Analysis of Cold Air Generation Area Considering Climate-Ecological Function -A Case Study of Changwon, South Korea- (기후생태적 기능을 고려한 찬공기 생성지역 분석 -창원시를 대상으로-)

  • Song, Bong-Geun;Park, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.13 no.1
    • /
    • pp.114-127
    • /
    • 2010
  • The purpose of this study is to find out cold and fresh air producing areas using climate-ecological functions in Changwon city, Gyeongsangnam-do, South Korea. The evaluation of climate-ecological functions were composed of the six factors: patch size with cold air generation and inflow functions, farmland and grassland ratio, mean slope degree, cross section types, mean slope length and roughness of bottom in valley. The analysis results of each evaluation factor in the study area were divided into 5 grades according to the capacity of cold air generation. The first-grade area with the highest factor values for cold air generation was take up 3.51% of the total study area, second grade was 13.48%, third grade was 31.65%, fourth grade was 27.28%, and fifth grade was 24.09%. According to the spatial distribution of cold air producing areas, the valleys around Mt. Bongnim, Changwon tunnel, and Anmin tunnel had higher evaluation grade. It will require the future research to establish the climate-ecological conservation areas and to construct the wind corridor based on the long-term microclimatic monitoring.

A Study on The Performance of Ventilation and Thermal Environment for a Combined Type Diffuser in a Residential Space (거주공간에 대한 급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • In this study, the combined-type diffuser developed by the Authors, in a previous study, was applied to a residential space. The performance of a ventilation and thermal environment, created by the use of a combined-type diffuser was compared to the pan-type diffuser widely used in apartment houses. In cooling conditions, because of the relatively high air flow rate of ceiling cassette-type air conditioners, the characteristics of airflow distribution in a room were governed by the air conditioner's airflow. In heating conditions, because of the low air flow rate of the diffuser, the characteristics of airflow distribution were governed by the buoyancy effect created by cold external walls and a hot floor. In terms of the Air Diffusion Performance Index (ADPI), which is a thermal environmental index, the result of a combined-type diffuser was greater than a pan-type diffuser in both of cooling and heating conditions. Consequently, the combined-type diffuser showed equal or superior ventilation and thermal environment performance compared to a pan-type diffuser.

A Study on the Characteristics of Perceived Temperature over the Korean Peninsula During 2007 Summer (한반도 2007년 여름철 인지온도 특성 연구)

  • Byon, Jae-Young;Kim, Jeong-Sik;Kim, Ji-Young;Choi, Byoung-Cheol;Choi, Young-Jean;Graetz, Angelika
    • Atmosphere
    • /
    • v.18 no.2
    • /
    • pp.137-146
    • /
    • 2008
  • This study examines one thermal index, perceived temperature (PT), over the Korean Peninsula during 2007 summer. Heat/cold stress has been described using air temperature and humidity for warm seasons and air temperature and wind velocity in the cold conditions, while PT is based on a heat budget model of the human body that considers air temperature, humidity, wind velocity and radiation effect regardless of climates, regions and seasons. PT is higher about $4-5^{\circ}C$ than air temperature in the summer. Humidity increases PT, while wind tends to reduces PT possibly by evaporation of water vapor. The geographical distribution of summer PT indicates that the lowest PT happened in the east central region, with the appearance of the highest PT in the inland of southern region in Korea. Although the latitudinal trend shows that PT decreases northward, inland PT is higher than that of coastal region. Compared to the heat index or the discomfort index that considers air temperature and humidity, PT represents distinctive regional characteristics of thermal comfort. The distribution of PT shows that it may be a useful thermal index for the assessment of thermal comfort or stress region in the Korean Peninsula.

Research on Packaging and Palletization for Improving Distribution Efficiency of Exported Fresh Agricultural Products (신선농산물의 수출 포장개발 및 파렛트화에 관한 연구)

  • Lee, Soo-Keun;Lee, Myung-Hoon
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.11 no.2
    • /
    • pp.75-79
    • /
    • 2005
  • With three kinds of agricultural products such as perilla leaves, this research is focussed on how to keep a freshness of agricultural products during long time transport by sea. In case of export fresh agricultural products by sea, research on products loading method onto the pallet is very important factor for keeping effective cold air circulation inside the freezing marine container. Details are as follows: Clear examination of palletization for cold air ventilation inside the container. Optimization of package dimension for best loading efficiency onto the standard pallet. Best layout of palletized products inside the container. Research for the change of circumstance and product quality inside the pack.

  • PDF

A Field Measuring Study on the Thermal Environment of Human Surrounding in the Classroom Equipped with Ceiling Unit (천장형 유닛을 설치한 교실 내의 인체 주변 온열환경에 관한 실측연구)

  • Cho Sung-Woo;Im Young-Bin;Lee Kyung-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.240-246
    • /
    • 2006
  • This paper performed to investigate on vertical temperature distribution, effective draft temperature (ETD) and PMV (Predicted Mean Vote) in the classroom, which is located YangSan city (Kyungsangnam-Do), Korea, is equipped with ceiling unit. The vertical temperature difference between F.L+10 cm (ankle) and F.L+120 cm (neck) of a measuring point which is adjacent corridor in the classroom showed about $1^{\circ}C$ but of measuring point which is adjacent outdoor expressed up to $4^{\circ}C$, The effective draft temperature (ETD) is -2.3 and -0.52 and 0.67 at near ceiling unit but is 1.2 and 3.3 at far from ceiling unit. The PMV of total classroom showed the range of 'Cold' and 'Slightly Cold.' Therefore, to achieve comfort condition in the classroom is equipped with ceiling unit, the location of ceiling unit and discharge angle and discharge distance from ceiling unit are very important elements.

The Utilization of MPCM Slurry for a Cooling System

  • Lee Hyo-Jin;Lee Jae-Goo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.4
    • /
    • pp.175-183
    • /
    • 2005
  • The present study has been conducted for manufacturing MPCM (microencapsulated phase change material) slurry with in-situ polymerization and proving their applicabilities for cooling system. The tetradecane as a core material of MPCM is coated with melamine. The produced capsules are observed by the optical microscope and SEM for superficial shapes and analysed their properties by DSC and particle size distribution by FA particle analyzer. It is found that narrow size distribution in 1 to $10{\mu}m$ is resulted in $5{\mu}m$ of average diameter and $9^{\circ}C$ melting temperature. The durability of MPCM capsules is tested with various types of pumps such as centrifugal, peristaltic, and mono. For the centrifugal and peristaltic pumps the breakage fraction of the capsules is resulted within $6\%$ during 10,000 cycles, while the mono is over $8\%$. The cooling system, which has adopted MPCM slurry as a medium for transporting cold thermal energy, is designed to investigate the performance of newly developed coolant. The discharging times of cold energy in circulating 10 and $20wt\%$ MPCM slurry are lasted to 105 and 285 minutes, respectively.

The temperature distributions of the curing space according to blocking the opening of gang-form at the apartment in the cold weather (동절기 공동주택 갱폼 개구부 천막보양에 따른 보양 온도 분포 분석)

  • Cho, Hong-Bum;Song, Jin-Hee;Kim, Young-Sun;Choi, Ji-Su;Lee, Kyu-Nam
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.140-141
    • /
    • 2022
  • CFD analysis was performed to analyze the temperature distribution of the inner space of the curing house according to blocking the opening of the gang-form with a tent in case of concrete pouring and heat curing of the apartment house during the winter season. If the gang-form opening is closed with a tent during internal heating using a hot air blower in the winter, the internal temperature rises compared to the non-reserved due to air-tightness of the curing spaces, and uniform temperature distribution can be ensured. In addition, it is possible to increase curing efficiency by reducing the amount of heat supplied and shortening the heating time.

  • PDF

The Study on the Effect of Passenger Coach temperature When Aircurtains Installed At Electrical Rolling Stock At Entrance Door (전동차 출입문에 에어커튼 설치시 객실 온도 변화 연구)

  • Ahn Jong-Kon;Kim Chul-Ho;Park Duk-Sin
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.489-496
    • /
    • 2004
  • The effect of airconditioning and heating system when aircurtains installed in subway electrical rolling stock at entrance door. It blocks cold/hot air of outside. It is good for health with its blocking effect against dusts exhaust fumes, odor bugs and smoke from outside. It always maintains clean and pleasant atmosphere inside. It helps you to have health with its ever-equal temperature distribution at inside. It saves lots of maintenance cost for heating/cooling (about 86$\%$) since it cuts the loss of hot air under heating as well as of cold air under air-conditionin. Customers can feel pleasant go in and out (better than before) with the door. It is an indispensable product for the employers to cut the cost. It makes customers feel pleasant near doors, since it isnt influenced by temperature difference of cold/hot air when the door opens/closes. In electrical rolling stock passenger temperature is a lot different from that the door opens/closes. One of the main aims is to create an acceptable thermal environment without draught problem. Temperature, gradients when aircurtains installed in subway electrical rolling stock at entrance door have been studied. And the temperature measured at 0.1, 0.5, 1.3, 1.7m above the floor. It has been found that temperature, with large fluctuations caused more draught influence.

  • PDF