• Title/Summary/Keyword: Coil diameter

Search Result 251, Processing Time 0.044 seconds

Ice Making Characteristics according to Shape and Diameter on Ice-on-Coil Tube (관외착빙형 제빙관의 형태 및 관경 변화에 따른 제빙 특성)

  • Park, K.W.;Jeong, E.H.;Hwang, S.S.
    • Journal of Power System Engineering
    • /
    • v.16 no.5
    • /
    • pp.32-39
    • /
    • 2012
  • The study experimented to understand ice-on-coil type ice making characteristics on to 3 kinds of circular tube, oval tube and small diameter tube using ice maker. The experiment were carried out under various conditions, that used brine temperature($-10^{\circ}C$, $-6^{\circ}C$), brine flow rate(1.0m/s, 1.8m/s) and inlet water temperature ($6^{\circ}C$, $12^{\circ}C$) etc. Mass of ice per ice making area increased according to the decrease of the brine temperature and inlet water temperature, but that was increased according to the increase of the brine flow rate. Oval ice making tube produced ice 1.11 to 2.46 times that of 9mm circular ice making tube, and 3mm small diameter ice making tube produced ice 1.06 to 1.51 times that of 9mm circular ice making tube.

Analytical and Experimental Study for Development of Composite Coil Springs (복합재 코일스프링 개발을 위한 수치해석 및 실험적 연구)

  • Oh, Sung Ha;Choi, Bok Lok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • This paper shows the feasibility of using carbon-fiber-reinforced polymer (CFRP) composite materials for manufacturing automotive coil springs. For achieving weight reduction by replacing steel with composite materials, it is essential to optimize the material parameters and design variables of the coil spring. First, the shear modulus of a CFRP beam model, which has $45^{\circ}$ ply angles for maximum torsional stiffness, was calculated and compared with the test results. The diameter of the composite spring was predicted to be 17.5 mm for ensuring a spring rate equal to that when using steel material. Finally, a finite element model of the composite coil spring with $45^{\circ}$ ply angles and 17.5 mm wire diameter was constructed and analyzed for obtaining the static spring rate, which was then compared with experimental results.

Evaluation of the Spring Constant of a Micro Coil Spring (마이크로 코일 스프링의 스프링 상수 평가)

  • Lee J. K.;Jeon B. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.10a
    • /
    • pp.255-259
    • /
    • 2001
  • The spring constant of a micro coil spring was measured by uniaxial tensile test. The inner diameter of it is $35{\mu}m$ and the pitch size is about $23{\mu}m$. A suing constant measurement system was developed. It consists of control units, load cell units, linear stages and several specially designed jigs and fixtures. Load and displacement are measured using a commercial load cell of 1000g capacity and a magnetic scale of $0.5{\mu}m$ resolution. In this study, a method to measure the spring constant of micro coil spring is presented and the relationship between misalignment of specimen and measurement error is discussed.

  • PDF

Reheating Process of Particulates Reinforced Metal Matrix Composites for Thixoforming (Thixoforming을 위한 입자강화형 금속복합재료의 Reheating 공정)

  • 이동건;안성수;강충길
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.04a
    • /
    • pp.218-223
    • /
    • 2000
  • A both mixing process of electro-magnetic stirring and mechanical process technique were used to fabricate particulate metal matrix composites(PMMCs) for variation of particle size. The PMMCs were tested for their tensile test for with and without heat treatment with T6. PMMCs fabrication processing conditions for both electrical and mechanical process are also suggested. In order to thixoforming of PMMCs, fabricated billet are reheated by using the optimal coil designed as a function of length between PMMC billet and coil surface, coil diameter and billet length. The effect of reinforcement distribution on billet temperature variation are investigated with calculated solid fraction theory proposed as a function of matrix alloy and volume fraction of reinforcement.

  • PDF

Evaluation of Heat Transfer performance of Wire-coil Inserted Tube (와이어코일 삽입법을 이용한 열전달 촉진기술 성능평가)

  • 이주동;박종호;이상천
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.5
    • /
    • pp.457-465
    • /
    • 2000
  • An experiment was carried out to evaluate the thermal performance of the wire-coil inserts method. Tested were the smooth tubes with the wire-nil inserts of various pitch and helix angle combinations. Test fluids were the 50%-solution of the ethylene glycol and the Hue water. Heat transfer coefficient and friction factors were deduced from the measured values of temperatures, flowrates and pressure drops. A unified dimensionless correlation for the heat transfer coefficients was developed as a function of the pitch to diameter ratio, the Reynolds number and the Prandtl number. An exergy analysis was performed to evaluate an optimal operating condition with the wire-coil inserts.

  • PDF

Parameters of a guiding coil for wireless power transfer (근거리 전송에 적합한 가이딩 코일의 파라미터)

  • Woo, Dae-Woong;Kim, Jae-Hee;Lee, Dong-Hyun;Park, Kyung-Ho;Park, Wee-Sang
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.345-346
    • /
    • 2008
  • We analyzed the structural parameters of a guiding coil and a feeding loop for wireless power transfer in mid-range. The length, diameter, and number of turns of the guiding coil are the major factors to determine the resonant frequency. The separation distance between the coil and the loop also affects the power transfer ratio. This scheme has a greater transmission efficiency than using dipoles.

  • PDF

Usefuless of Multi-functional Gastroduodenal Coil Catheter with Gastric Phantom (팬텀을 이용한 다기능 위$\cdot$십이지전관 코일 카테타의 유용성 평가)

  • Lim Jin-Oh;Kim Tae-Hyung;Jung Yang-Hwa;Choi Won-Chan;Lee Kwang-Jong;Song In-Wook;Lee hyeong-Jin
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.29 no.1
    • /
    • pp.61-66
    • /
    • 2003
  • Purpose : To evaluate was the newly designed gastroduodenal coil catheter: in-vitro test. Material and Method : the coil catheter that we made in our laboratory was 150 cm. The coil that is made of stainless steel wire was composed 1.3m inner diameter and

  • PDF

A study on Rogowski coil for measuring Short-circuit currents (단락전류 측정용 Rogowski coil 개발)

  • Lee, Yong-Shin;Park, Ji-Hoon;Ham, Gil-Ho;Choi, Won-Suk;Chang, Yong-Moo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.787-789
    • /
    • 2000
  • This paper describes the theory and practical design of Rogowski coil and active integrator. The coils and integrators have the ratings as follows. 1) current ratings between 20kArms and 200kArms 2) current duration 3 seconds 3) time constant of primary circuit looms 4) inner diameter of coil is suitable for mounting at the busbar $200mm{\times}200mm$. The actual results in the short-circuit tests and compare with other sensors, such that shunt. are given also.

  • PDF

Effect of Heat Treatment on Properties of Tungsten Embolization Coils (텅스텐 색전코일의 특성에 미치는 열처리 효과)

  • Son, Ung-Hui;Hong, Sun-Hyeong;Sin, Gyeong-Min;Lee, Yun-Sin;Park, Jae-Hyeong
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.333-339
    • /
    • 1998
  • The effect of heat treatment conditions on the properties of tungsten(W) embolization coils has been evaluated. The W embolization coils were fabricated by coiling the primary W coil with a diameter of 30.mm on a alumina rod mandrel with a diameter of 2.92mm. The secondary coils were then heat treated at 475$^{\circ}C$and 600$^{\circ}C$ for various heat treatment time ranging from 5 minutes to 36hours. The pitch distance, diameter and shape retention capability of the W embolization coils were characterized after the heat treatment. The pitch distance of the W embolization coils increased with the heat treatment time. The diameter of W emboliazation coils decreased continuously with heat treatment time. The shape retention capability of the W embolization coils increased with the heat treatment time due to an increase in elasticity by formation of tungsten oxide film on W coil surface during the heat treatment. The heat treatment condition of W embolization Col at 600$^{\circ}C$ for 20 minute was considered desirable based on the optimization of the shape retention capability, pitch distance and secondary coil diameter after heat treatment.

  • PDF

A Study on the Pressure Loss in Helically Coiled Tubes (나선코일 튜브 내에서의 압력손실에 관한 연구)

  • Han, K.I.;Bark, J.U.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.155-165
    • /
    • 1998
  • The resistance coefficient and heat transfer performance are studied for the turbulent water flow in a smooth coiled tube having variable curvature ratios and a corrugated-coiled tube having a ratio of coil to tube diameter of 22. Experiments are carried out for the fully developed turbulent flow of water in tube coils on the uniform wall temperature condition. This work is limited to tube coils of R/a between 22 and 60 and Reynolds numbers from 13000 to 53000. The tube having a ratio of coil to tube diameter of 27 among the 3 smooth tube coils shows the best heat transfer performance. A corrugated-coiled tube(R/a=60) shows more excellent performance than a smooth coiled tub (R/a=60) at a similar curvature ratio. The friction factor f is sensitive to changes in the velocity profile caused by a temperature gradient. Allowance was made for the pressure loss in the short inlet and outlet lengths and due to the presence of the thermocouple inlet and outlet as a result of separate experimental on a straight tube. It is to be expected that the allowance at the exit will be somewhat too low because of secondary flow effects carried over from the coil.

  • PDF