• Title/Summary/Keyword: Coil Design

Search Result 998, Processing Time 0.029 seconds

Preliminary Study of Hybrid Micro Gas Turbine Engine (하이브리드 타입 초소형 가스터빈엔진 개발 및 초도 시운전)

  • Seo, Junhyuk;Choi, Juchan;Kwon, Kilsung;Baek, Jehyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.1
    • /
    • pp.24-30
    • /
    • 2016
  • In this study, a 2W micro-gas turbine engine was designed using micro-electro-mechanical systems (MEMS) technology, and experimental investigations of its potential under actual combustion conditions were performed. A micro-gas turbine (MGT) contains a turbo-charger, combustor, and generator. Compressor and turbine blades, and generator coil were manufactured using MEMS technology. The shaft was supported by a precision computer numerical control (CNC) machined static air bearing, and a permanent magnet was attached to the end of the shaft for generation. A heat transfer analysis found that the cooling effect of the air bearing and compressor was sufficient to cover the combustor's high temperature, which was verified in an actual experiment. The generator performance test showed that it can generate 2W at design rotational speed. Prototype micro-gas turbine generated maximum 1 mW electric power and lasted up to 15 minutes.

Improvement of Current Limiting and Recovery Characteristics of Flux-Lock Type SFCL with Series Connection of Two Coils Using Its Third Coil

  • Ko, Seok-Cheol;Kim, Young-Pil;Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.472-477
    • /
    • 2017
  • In this work, the current limiting and recovery characteristics of a flux-lock type superconducting fault current limiter (SFCL) with series connection of two coils were effectively improved by adding a third winding into the conventional flux-lock type SFCL with series connection of two coils. To confirm the contribution of the third winding to the current limiting and recovery characteristics of this type of the SFCL, short-circuit testing was carried out with consideration of the third winding, and the effect of the third winding on the current limiting and recovery characteristics was examined by comparative analysis of the amplitude of the limited fault current and the power burden of the high-TC superconducting (HTSC) element comprising the SFCL. Through the analysis of both the limiting impedance and the operational current as the main design parameter of the SFCL, the improved current limiting and recovery characteristics of the flux-lock type SFCL using the third winding could be verified.

On the Current Limiting Characteristics and Parameters of Superconducting Fault Current Limiter Introduced to 345kV Electric Power System due to Resistive-Type, Reactive-Type (유도형과 저항형 초전도한류기의 파라메타를 고려한 전력계통도입효과의 분석 및 고찰)

  • 홍원표;김용학;전영환;이승학
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.285-290
    • /
    • 2002
  • Power systems are becoming larger and larger for meeting electric power demand. Therefore, the over-currents resulting from contingencies such short circuits are increasing higher. The Maximum short circuit current of modern power system is becoming so large that circuit breaker are not expected th be able to shut down the current in the future. In order to cut over-currents, a system composed of a superconducting fault current limiter(SFCL) and traditional breaker seems to provide a promising solution for future power operation. In present paper, three line-to-ground fault is assumed to happen at the center of 345kV transmission lines in a large capacity electric power system The superconducting fault current limiter was represented using a commutation type, which consists of a non-inductive superconducting coil and current limiting element(resistor or reactor). The introduction merits of the SFCL were investigated quantitatively by RTDS/EMTDC from the viewpoint of current limiting performance, the prevention of the voltage drop at the load bus and comparison characteristics for two type SFCL. Desired design specification and operation parameters of SFCL were also given qualitatively by the performance evaluation of the two type SFCL in the power system.

  • PDF

Design of ultraprecision hi-directional actuator for nm using a permanent magnet and electromagnet (영구 자석과 전자석의 상호작용을 이용한 초정밀 양방향 구동기 설계)

  • Kim Ki-Hyun;Gweon Dae-Gab
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.9 s.174
    • /
    • pp.147-154
    • /
    • 2005
  • A precision hi-directional actuator for a high precision leveling system with $Z{\Theta}_x{\Theta}_y$ motions is proposed and designed in this paper. The actuator is composed of a force generation structure, a guide mechanism, and a symmetric structure. At first, its driving force is generated by a change of flux in air gaps by permanent and changeable flux. The permanent flux is generated by a permanent magnet. The changeable flux is created by variable current flowing through coil. The combination of permanent and changeable flux makes various flux densities in air gaps between moving part and fixed yokes. And then, the difference between flux densities in lower and upper gaps creates forces fur the $bi-direction({\pm}z)$ motion. The guide mechanism of this actuator is composed of two circular plates and one shaft. Reducing motions generated by forces except z-motion, these circular plates endow the actuator with high stiffness for fast settling time. And the function of the shaft is to transfer motion to an object. At last, total body has a symmetric structure to be stable on thermal error. The actuator is designed by MAXWELL 2D and ProMECHANICA. The designed actuator is evaluated by 8nm laser doppler vibrometer, dynamic signal analyzer, and simple PID controller.

Development of In-Process Polishing Pressure Control System (실시간 폴리싱 압력 제어시스템 개발)

  • 오창진;전문식;김옥현
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.1
    • /
    • pp.109-115
    • /
    • 2004
  • Polishing process has been applied to get extremely fine surfaces, e.g., mirror surfaces such as optical mirrors, lens, molds and etc. Nowadays not only fine surface quality but also submicron order of dimensional accuracy is required for many applications. To meet the requirements polishing process should be provided with an active control of polishing pressure especially for automation of polishing process. In this paper a study on development of an active polishing pressure control system has been presented. A new type of tool assembly has been developed to facilitate the control. The tool is attached to an axis of a polishing machine with a coil spring and control of the polishing pressure is done by the position control of the axis, which needs no additional actuator. The polishing pressure is successfully measured by the measurement of the spring deformation. Control specifications were quantitatively considered by weighting functions and a controller was designed by using loop-shaping technique based on the no synthesis. Some experiments have been executed on a polishing machine with a PC-NC controller. It is shown that the results were coincident well with the theoretical analyses and satisfied the design specifications.

Design of Slotless BLDC Motor Considering the Thermal Characteristic (SLotless BLDC motor의 열적 특성을 고려한 설계)

  • Baek, S.H.;Cha, H.R.;Yun, C.H.;Kang, S.Y.;An, J.Y.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.104-106
    • /
    • 2006
  • Slotless BLDC motor는 Slot과 Teeth가 없으므로 이에 따른 Cogging Torque 및 Torque Ripple이 거의 존재 하지 않으며, 전동기의 무게 또한 감소하게 된다. 또한 권선의 장주(Span)가 짧아 Inductance가 낮기 때문에 고속화가 용이해지며, Slot의 부재는 좀 더 많은 Coil권선을 이용 할 수 있다. 하지만 모터의 구조상 전기장하가 높아짐에 따라 권선의 온도 상승에 대한 보완 등이 필요로 되어 지고 있다. 따라서 본 논문에서는 온도 상승 문제를 해결하기 위해 열 발생과 모터사이의 관계 규명을 전류 밀도 함수로 표시 하였고, 전류 밀도 최소화 설계 방법을 제안하였다. 퍼미언스법에 의한 간략 설계에 의해서 기본 설계를 실시 한 후 FEM을 통한 정밀 해석을 통해서 각각의 민감도를 분석하여 최적의 파라메타를 선정하는 방식을 취하였다. 또한 고속 회전시 발생되는 진동을 저감하기 위해 모터의 길이방향 즉 적층과의 관계를 통하여 진동 저감 설계를 제안하였다.

  • PDF

The Design of Phase Angle Controller Reducing Sub-harmonic Current for Universal Motor in Vacuum Cleaner (진공청소기용 유니버셜모터의 고조파전류 저감 위상각제어기 설계)

  • 임홍우;장용해;백형래
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.237-243
    • /
    • 2002
  • The single phase angle control system may become noisy when speed Is modulated with a conventional TRIAC AC controller. But this system is widely used despise of occurring sub-harmonic current because of its simply structure and low cost. Most of the vacuum cleaner drive control system regulates TRIAC's phase angle, so that it is controlled the speed. In the case of marketing product, it is not considered linearity of the speed to minimize occurring harmonic current. The sub-harmonic current reduces effectively in regulating specification TRIAC trigger phase angle. In this paper, we examined about characteristics of phase angle controller and parameter of parallel coil for eliminating sub-harmonic current.

Sequence Control of Small-scaled ITER Power Supply for Reactive Power Compensation (무효전력을 보상하는 축소형 ITER 전원공급장치의 순차제어)

  • Heo, Hye-Seong;Park, Ki-Won;Ahn, Hyun-Sik;Jang, Gye-Yong;Shin, Hyun-Seok;Choi, Jung-Wan;Oh, Jong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.932_933
    • /
    • 2009
  • A technology based on thyristors will be used to manufacture the super-conducting coil AC/DC converters because of the low ratio of cost over installed power compared to a design based on GTO or similar technology. But phase-controlled converter suffers from fundamental disadvantage. They inject current harmonics into the input ac mains due to their nonlinear characteristics, thereby distort the supply voltage waveform, and demand reactive power from the associated ac power system at retarded angles. To overcome this disadvantage, in the case of two series converters at the DC side, connected to the same step-down transformer, apply for the sequence control. It is the most simple and efficient way to reduce the reactive power consumption at low cost. Analytical sequence control algorithm is suggested, the validity of the proposed scheme has been verified by experimental results with the small-scaled International Thermonuclear Experimental Reactor (ITER) Power Supply to minimize reactive power consumption.

  • PDF

Analysis on the Measured Natural Frequencies Due to the Structure-Exciter Interaction (구조물-가진기 상호작용에 의한 공진주파수 변동에 대한 해석)

  • Han, Sang-Bo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.7
    • /
    • pp.2108-2117
    • /
    • 1996
  • The purpose of this paper is to investigate the influence of the exciter attached for the measurement of natural frequencies when extracting the frequency response functions of the test structure in experimental modal analysis. The procedure is first to model the attached exciter as an additional degree of freedom system and next to verify the suggested model by experimentally extracting the natural frequencies of the test structure with various values of exciter mass, stinger stiffness and attachment position of the exciter on the test structure. It is concluded that as additional degree of freedom system which includes the natural frequency of the exciter itself and axial stiffness of stinger should be considered to quantatively define the coupling effects of structure-exciter interaction on the measured natural frequencies. It is not the mass of the exciter itself but the coupling effect of the additional degree of freedom mass-spring system consisting of exciter body and armature coil that characterizes the natural frequency deviation. Therefore, when the natural frequency of this additional mass-spring system is outside of the test frequency range, the coupling effect of structure-exciter interaction can be minimized.

Design of Fault-Tolerant Inductive Position Sensor (고장 허용 유도형 위치 센서 설계)

  • Paek, Sung-Kuk;Park, Byeong-Cheol;Noh, Myoung-Gyu D.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.3
    • /
    • pp.232-239
    • /
    • 2008
  • The position sensors used in a magnetic bearing system are desirable to provide some degree of fault-tolerance as the rotor position is necessary for the feedback control to overcome the open-loop instability. In this paper, we propose an inductive position sensor that can cope with a partial fault in the sensor. The sensor has multiple poles which can be combined to sense the in-plane motion of the rotor. When a high-frequency voltage signal drives each pole of the sensor, the resulting current in the sensor coil contains information regarding the rotor position. The signal processing circuit of the sensor extracts this position information. In this paper, we used the magnetic circuit model of the sensor that shows the analytical relationship between the sensor output and the rotor motion. The multi-polar structure of the sensor makes it possible to introduce redundancy which can be exploited for fault-tolerant operation. The proposed sensor is applied to a magnetically levitated turbo-molecular vacuum pump. Experimental results validate the fault-tolerance algorithm.