• 제목/요약/키워드: Coil Channel

검색결과 96건 처리시간 0.032초

가솔린 직분사 엔진에서 운전 조건에 따른 공기 유동 특성에 의한 분무 거동 및 점화 채널에 관한 연구 (Study on Behavior of Spray and Spark Channel by Air Flow Characteristics According to Operating Conditions in Gasoline Direct Injection Engine)

  • 이호승;박성욱
    • 한국분무공학회지
    • /
    • 제28권4호
    • /
    • pp.198-206
    • /
    • 2023
  • In this study, visualization of in-cylinder spray behavior and spark channel stretching by air flow characteristics depending on engine operating conditions were investigated. For in-cylinder spray behavior, increase in engine rpm did not alter the counter-clockwise air flow direction and location of in-cylinder dominant air flow but increased average air flow velocity, which hindered spray propagation parallel to the piston surface. When injection timing was retarded, direction of in-cylinder dominant air flow was changed, and average air flow velocity was reduced resulting in an increase in spray penetration length and change in direction. For spark channel stretching, increase in air flow speed did not affect spark channel stretch direction but affected length due to increase in spark channel resistance and limitation of energy ignition coil can handle. Change in air flow direction affected spark channel stretch direction where the air flow was obstructed by ground electrode which caused spark channel direction to occur in the opposing direction of air flow. It also affected spark channel stretch length due to change in air flow speed around the spark plug electrode from the interaction between the air flow and ground electrode.

Development of Birdcage RF coil for 3T Animal MR Imaging

  • 추명자;최보영;강세권;최치봉;이형구;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제13권2호
    • /
    • pp.85-89
    • /
    • 2002
  • 목적 : 사람에 비하여 크기가 현저히 작은 동물의 자기공명영상 촬영을 위하여 상용으로 인체에 적용하는 Head 코일보다 원통 반지름이 작은 Low-Pass Type Birdcage 코일을 제작함으로써 보다 큰 신호대잡음비 (Signal-to-Noise Ratio. SNR)를 얻고자 하였다. 방법 : 자기공명영상을 얻기 위해 Spin Echo 펄스시퀀스와 Fast Spin Echo 펄스시퀀스를 사용하였다. T1 강조영상을 얻기 위한 Spin Echo 펄스시퀀스의 매개변수는 TR/TE=300/17 ㎳, Matrix=256$\times$256, Field Of View (FOV)=150 mm, Slice Thickness=2 mm 이었다. T2 강조영상을 얻기 위한 Fast Spin Echo 펄스시퀀스의 매개변수는 TR/TE=3000/96 ㎳, Matrix=256$\times$256, Field Of View (FOV)=150 mm, Slice Thickness=2 mm 이었다. 원통의 지름이 13 cm인 Birdcage 코일은 12개의 elements로 구성되어 있으며 길이는 22 cm로 제작되었다. 결과 : 코일 원통의 반지름의 크기에 따른 SNR을 비교하기 위하여 인체용 Knee 코일과 동물용으로 제작된 코일을 이용하여 각각의 팬톰 영상을 획득하였다. 팬톰 영상으로부터 측정된 SNR의 값을 통해 반지름이 작은 동물용 코일의 SNR이 더 크다는 걸 확인할 수 있었다. 토의 및 결론 : 본 연구를 통하여 같은 형태의 Birdcage 코일일 경우 원통의 반지름에 따라 SNR이 다르며, 특히 반지름이 작을 때 SNR이 더 크다는 것을 알 수 있었다. 따라서 코일의 크기에 비해 촬영하고자 하는 대상물의 부피가 작은 경우 대상물의 부피에 맞추어 코일을 제작하면 SNR이 보다 뛰어난 영상을 얻을 수 있을 것으로 사료된다.

  • PDF

700 W급 홀 전기추력기 랩모델 연구개발 (Development of a 700 W Class Laboratory Model Hall Thruster)

  • 도근태;김영호;이동호;박재홍;최원호
    • 한국추진공학회지
    • /
    • 제25권5호
    • /
    • pp.65-72
    • /
    • 2021
  • 소형위성의 궤도조정 및 궤도유지에 활용될 수 있는 700 W급 홀추력기 랩모델을 개발하였다. 스케일링 방정식을 사용하여 방전채널의 크기를 선정하였으며, 자기장이 방전채널 중심선을 기준으로 대칭성을 가지면서 방전채널 바깥에서 최대가 되도록 설계하였다. 개발된 홀추력기의 방전시험은 2.0×10-5 Torr 이하의 배경압력을 갖는 진공 환경에서 수행되었으며 추력 스탠드를 이용하여 추력을 측정하였다. 양극전압을 300 V로 고정하고 양극유량과 코일전류를 변수로 하여 추력을 측정하였으며, 양극유량 2.36 mg/s, 코일전류 2.4 A 조건에서 양극전력 620 W에서 추력 38 mN, 통합비추력 1,540 s, 양극효율 50 %로 가장 높은 성능을 보였다.

심자도 신호 검출을 위한 Flux Locked Loop (FLL) Emulation 회로 (Emulator Circuit for a Flux Locked Loop for Detection of Magnetocardiography Signal)

  • 안창범;이동훈;김인기;장경섭;김기태;정동현;최중필
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2749-2752
    • /
    • 2003
  • Magnetocardiography is a very weak biomagnetic field generated from the heart. Since the magnitude of the biomagnetic field is in the order of a few pico Tesla, it is measured with a superconducting quantum interference device (SQUID). SQUID is a transducer converting magnetic flux to voltage, however, its range of linear conversion is very restricted. In order to overcome the narrow dynamic range. a flux locked loop is used to feedback the output field with opposite polarity to the input field so that the total Held becomes zero. This prevents the operating point of the SQUID from moving too far away from the null point thereby escape from the linear region. In this paper, an emulator for the SQUID sensor and feedback coil is proposed. Magnetic courting between the original field and the generated field by the feedback coil is emulated by electronic circuits. By using the emulator, FLL circuits are analyzed and optimized without SQUID sensors. The emulator may be used as a test signal for multi-channel gain calibration and system maintenance.

  • PDF

Design and Fabrication of the Spiral Coils for Guided Wave Magnetostrictive Transducers

  • Choi, Myoung-Seon;Heo, Won-Nyoung;Jun, Jong-Kil
    • 비파괴검사학회지
    • /
    • 제28권6호
    • /
    • pp.496-503
    • /
    • 2008
  • We propose rectangular type spiral coils with folded comers for the applications to low frequency guided wave magnetostrictive transducers and describe a method for making the proposed coils from insulated electrical wire such as enameled copper wire. Expressions for the electrical properties of the coils are also presented and compared with experimental measurements. An overlapped-2-channel folded-comer spiral-coil array is fabricated and applied to a magnetostrictive strip transducer generating and detecting fundamental torsional mode guided waves. From the results we conclude that the design and fabrication method make it possible to use the magnetostrictive transducers optimized for various guided wave applications and also will greatly help engineers gain easy access to the optimized transducers.

HTS pancake 코일을 모의한 전극계에서의 전기절연 특성 (Electrical insulation characteristics with simulated electrode system of HTS)

  • 정종만;백승명;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.58-63
    • /
    • 2002
  • For the experiment the four types of spacer were distinguished by arrangement. The flashover characteristic on each types of spacer was investigated and the flashover phenomena were observed to understand breakdown mechanism in liquid nitrogen($LN_{2}$). The spacer should be placed interior coil as an insulator, a cooling channel and s supporter of structures. The simulated electrode used in the experiment was made from five turns of HTS tape. Experimental results revealed that multi-layer and barrier effects did work well in Air but did not in $LN_{2}$. These result suggested that the flashover in LN2 caused by the bubbles due to partial discharge at micro gap, g. The flashover characteristics decreased to 70% when g is 0.2 mm. The degradation was improved by even treatment on surface of coil electrode.

  • PDF

3차원 코일 모델링을 통해 위상배열코일 성능을 평가하기 위한 프로그램 (A Tool Box to Evaluate the Phased Array Coil Performance Using Retrospective 3D Coil Modeling)

  • ;;;조민형;이수열
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권2호
    • /
    • pp.107-119
    • /
    • 2014
  • 목적: 실제 촬영 결과와 전자기 모의실험 결과를 시각적으로 비교함으로써 위상배열코일을 이루는 모든 코일 요소의 감도를 효과적으로 검증할 수 있는 소프트웨어를 개발하였다. 대상과 방법: 위상배열코일검증기(PACE)라 불리는 프로그램을 MATLAB과 C언어를 이용해 구현하였다. 위상배열 코일검증기는 코일 소자의 3차원 형상 모델 구축, FDTD 모의실험 결과의 수용, 보통의 직각좌표계 및 코일면에 기준하는 직각좌표계 상에서 각기 코일 소자 감도를 도시하는 기능을 가지고 있다. 위상배열코일의 3차원 형상 모델을 구축하기 위해 바늘침 모양의 3차원 전자기 위치추적기를 사용하였다. 3차원 형상 모델을 만든 뒤, 이 형상 모델 데이터를 FDTD 모의실험 장치에 보낼 수 있게 하였다. 결과: 3차원 전자기 위치추적기를 이용해 실제 실험에 사용된 위상배열코일과 FDTD 모의실험에 사용된 위상배열코일 모델을 정확하게 일치시킴으로써, 각기 코일 소자의 공간적 감도를 평가할 때 모의실험 결과와 촬영실험 결과 사이 정확한 비교가 가능하게 되었다. 모의실험과 실제 촬영실험에는 36 채널의 헬멧형 위상배열코일을 사용하였다. MRI 촬영 대상체로는 FDTD 모의실험의 모델과 같은 크기와 형상을 가진 원통형 팬텀을 사용하였다. 개발한 프로그램에서는 위상배열코일의 성능을 편리하게 평가하기 위해 관심 코일 소자를 쉽게 선택할 수 있게 하였다. 결론: 개발한 위상배열코일 성능 검증 프로그램은 위상배열코일의 개발 및 정기적인 유지보수에 사용될 수 있을 것으로 기대한다.

6채널 SENSE Cardiac Array 코일을 이용한 검사 시 코일의 위치 변화에 따른 신호강도 (Signal Intensity Changes according to Coil Position Changes in MRI using 6 Channel SENSE Cardiac Array Coils)

  • 최관우;손순룡;유병규
    • 한국방사선학회논문지
    • /
    • 제12권5호
    • /
    • pp.699-706
    • /
    • 2018
  • 본 연구는 array 코일을 이용한 검사 시 코일의 위치변화에 따른 신호강도를 측정하여 영상의 신호강도가 급격히 저하되지 않는 기준 방향과 거리를 제시함으로써, 동일선상에 코일들이 위치하지 않았을 경우 신호강도가 저하되는 문제점을 개선해 보고자 하였다. 연구방법은 두 부분으로 나눠져 있는 array 코일에 multi-purpose MRI 팬텀을 위치시킨 다음 array 코일의 앞부분을 상, 하, 좌, 우 네 방향으로 중심에서 2 cm 씩 10 cm 까지 이동하며 영상을 획득한 후 신호강도를 측정하여 비교평가 하였다. 연구결과, T1, T2 강조 영상 모두 상 방향을 제외한 하 방향과 좌, 우 방향의 위치변화가 2 cm 이내인 경우 기준 신호강도인 중심의 신호강도와 유의한 차이가 없어 동일한 신호강도를 나타냄을 알 수 있었다. 결론적으로 array 코일을 이용한 검사 시 여러 가지 원인에 의해 동일선상에 코일들을 위치시킬 수 없을 경우 상 방향을 제외한 나머지 방향의 위치변화를 중심에서 2 cm 이내로 설정한다면 위치변화로 인해 신호강도가 저하되는 문제점을 개선할 수 있다.