• Title/Summary/Keyword: Cogeneration Plant

Search Result 67, Processing Time 0.025 seconds

Thermoeconomics to divided the energetic cost into each working fluid (CGAM problem analysis) (엑서지 단가를 각 작동유체별로 나눈 열경제학 (CGAM 문제해석))

  • Kim, Deok-Bong;Kim, Deok-Jin
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.222-227
    • /
    • 2000
  • At representative thermoeconomic theory to determine the unit cost of multiple products, there are the $\ulcorner$SPECO$\lrcorner$ method of Tsatsaronis's study group and the $\ulcorner$MOPSA$\lrcorner$ method of chung-ang university phase laboratory. Against this theory, we propose new theory called $\ulcorner$Thermoeconomics to divide the exergetic cost into each working fluid$\lrcorner$ in this study. Also, we apply new thermoeconomic theory to CGAM problem (30MW-grade imaginary gas turbine cogeneration power plant) that it is representative power system in thermoeconomics theory, and we fixed to interpreted the unit cost of electricity on the part of gas turbine and the unit cost of steam exergy(enthalpy) on the part of HRSG.

  • PDF

Development of Design Technology for Combined and Cogeneration Power Plant (복합열병합 발전 플랜트의 설계기술 개발사업의 추진 전략)

  • 오군섭
    • Journal of the KSME
    • /
    • v.35 no.6
    • /
    • pp.542-553
    • /
    • 1995
  • 복합열병합 발전 플랜트의 장점은 도시 근교에 발전 플랜트를 간단히 건설할 수 있으며, 공해를 크게 줄이면서 독립적인 발전이 가능하다는 측면에서 신도시, 신공업단지, 도서지방 등에서 아주 유리한 것으로 알려져 있다. 또한 가스 터빈 배기열을 이용하여 대규모 주거 지역이나 공업 단 지내에서 필요한 난\ulcorner냉방열이나 공업열원으로의 활용이 손쉬우며, 주변 시설이 복잡하지 않고, 개선된 연소기술에 의하여 공해를 크게 줄일 수 있다. 최근 들어 분당\ulcorner일산\ulcorner부천 지역 등에 열병합 플랜트가 건설되고 있으나 거의 모든 설계기술은 외국 기술에 의존되고 있으며, 국산화 율도 극히 저조하여 '93년도에 완공된 부천 화력(473MW)의 경우 약 30% 정도이다. 복합열병합 발전 시스템은 가스 터빈, 스팀 터빈 등의 터보기계 기술을 근간으로 하며, 열회수장치 및 열교 환장치의 설계기술, 각종 제어기술 등의 종합 설계기술로서 이미 선진국에서는 실용화된지 오 래되었으며 우리 나라에도 여러 종류의 플랜트가 도입되어 사용되고 있다.

  • PDF

Performance Characteristics of the Desiccant Cooling System in Various Outdoor and Load Conditions (외기조건에 따른 제습냉방시스템의 성능 특성)

  • Lee, Dae-Young;Chang, Young-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.623-628
    • /
    • 2009
  • Desiccant based air conditioning system offers a promising alternative to conventional one using vapour compression refrigeration for energy saving and greenhouse gas reduction. It is a heat driven cycle which has high potential for the use of low grade heat source such as the waste heat from the cogeneration plant or the solar thermal energy. In this study, the cooling performance of a desiccant cooling system incorporating a regenerative evaporative cooler was characterized in various operation conditions through numerical simulation. The cooling capacity and COP were evaluated at various outdoor conditions, regeneration temperatures, and supply flow rates. Based on the performance characteristics, the optimal control scheme was discussed to minimize the cooling cost at part load condition.

  • PDF

Design of a generator control system for small nuclear distributed generation

  • Yoon, Dong-Hee;Jang, Gil-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.311-318
    • /
    • 2011
  • Small-scale reactors have recently attracted attention as a potential power generation source for the future. The Regional Energy Research Institute for Next Generation is currently developing a small-scale reactor called Regional Energy rX 10 MVA (REX-10). The current paper deals with a power system to be used with small-scale reactors for multi-purpose regional energy systems. This small nuclear system can supply electric and thermal energy like a co-generation system. The electrical model of the REX-10 has been developed as a part of the SCADA system. REX-10's dynamic and electromagnetic performance on the power system is analyzed. Simulations are carried out on a test system based on Ulleung Island's power system to validate REX-10 availability on a power system. RSCAD/RTDS and PSS/E software tools are used for the simulation.

Energy Generating Self-cooling Greenhouse (열-전기 병합 에너지 생산 겸 자체 냉각 온실)

  • Kleinwachter, Jurgen;Chung, Mo;Kim, Jong-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.584-587
    • /
    • 2006
  • An energy generating greenhouse based on fluoropolymer envelope and fresnel lens is proposed. The outstanding properties of the fluoropolymer films make them very suitable for large scale solar applications. Extremely high optical transmission over the whole solar spectrum, combined with mechanical strength, and durability allows us to design a highly optimized greenhouses for both plant growing and energy generation. Systems such as photovoltaic triple junction cells are especially attractive since they have up to 35% efficiency with much less cell material when the sun beam is focused with concentrators such as fresnel lenses. Cooling such devices will enhance the efficiency and provide useful thermal energy that could be further utilized for various applications depending on the local demands. This article introduces the basic ideas and principles of the energy generating greenhouses as a first step towards the actual deployment of such systems under Korean environment.

  • PDF

POTENTIAL APPLICATIONS FOR NUCLEAR ENERGY BESIDES ELECTRICITY GENERATION: A GLOBAL PERSPECTIVE

  • Gauthier, Jean-Claude;Ballot, Bernard;Lebrun, Jean-Philippe;Lecomte, Michel;Hittner, Dominique;Carre, Frank
    • Nuclear Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.31-42
    • /
    • 2007
  • Energy supply is increasingly showing up as a major issue for electricity supply, transportation, settlement, and process heat industrial supply including hydrogen production. Nuclear power is part of the solution. For electricity supply, as exemplified in Finland and France, the EPR brings an immediate answer; HTR could bring another solution in some specific cases. For other supply, mostly heat, the HTR brings a solution inaccessible to conventional nuclear power plants for very high or even high temperature. As fossil fuels costs increase and efforts to avoid generation of Greenhouse gases are implemented, a market for nuclear generated process heat will be developed. Following active developments in the 80's, HTR have been put on the back burner up to 5 years ago. Light water reactors are widely dominating the nuclear production field today. However, interest in the HTR technology was renewed in the past few years. Several commercial projects are actively promoted, most of them aiming at electricity production. ANTARES is today AREVA's response to the cogeneration market. It distinguishes itself from other concepts with its indirect cycle design powering a combined cycle power plant. Several reasons support this design choice, one of the most important of which is the design flexibility to adapt readily to combined heat and power applications. From the start, AREVA made the choice of such flexibility with the belief that the HTR market is not so much in competition with LWR in the sole electricity market but in the specific added value market of cogeneration and process heat. In view of the volatility of the costs of fossil fuels, AREVA's choice brings to the large industrial heat applications the fuel cost predictability of nuclear fuel with the efficiency of a high temperature heat source tree of Greenhouse gases emissions. The ANTARES module produces 600 MWth which can be split into the required process heat, the remaining power drives an adapted prorated electric plant. Depending on the process heat temperature and power needs, up to 80% of the nuclear heat is converted into useful power. An important feature of the design is the standardization of the heat source, as independent as possible of the process heat application. This should expedite licensing. The essential conditions for success include: ${\bullet}$ Timely adapted licensing process and regulations, codes and standards for such application and design ${\bullet}$ An industry oriented R&D program to meet the technological challenges making the best use of the international collaboration. Gen IV could be the vector ${\bullet}$ Identification of an end user(or a consortium of) willing to fund a FOAK

Economic analysis of Frequency Regulation Battery Energy Storage System for Czech combined heat & power plant (체코 열병합발전소 주파수조정용 배터리에너지저장장치 경제성 분석)

  • KIM, YuTack;Cha, DongMin;Jung, SooAn;Son, SangHak
    • Journal of Energy Engineering
    • /
    • v.29 no.2
    • /
    • pp.68-78
    • /
    • 2020
  • According to the new climate change agreement, technology development to reduce greenhouse gases is actively conducted worldwide, and research on energy efficiency improvement in the field of power generation and transmission and distribution is underway [1,2]. Economic analysis of the operation method of storing and supplying surplus electricity using energy storage devices, and using energy storage devices as a frequency adjustment reserve power in regional cogeneration plants has been reported as the most profitable operation method [3-7]. Therefore, this study conducted an economic analysis for the installation of energy storage devices in the combined heat and power plant in the Czech Republic. The most important factor in evaluating the economics of battery energy storage devices is the lifespan, and the warranty life is generally 10 to 15 years, based on charging and discharging once a day. For the simulation, the ratio of battery and PCS was designed as 1: 1 and 1: 2. In general, the primary frequency control is designed as 1: 4, but considering the characteristics of the cogeneration plant, it is set at a ratio of up to 1: 2, and the capacity is simulated at 1MW to 10MW and 2MWh to 20MWh according to each ratio. Therefore, life was evaluated based on the number of cycles per year. In the case of installing a battery energy storage system in a combined heat and power plant in the Czech Republic, the payback period of 3MW / 3MWh is more favorable than 5MW / 5MWh, considering the local infrastructure and power market. It is estimated to be about 3 years or 5 years from the simple payback period considering the estimated purchase price without subsidies. If you lower the purchase price by 50%, the purchase cost is an important part of the cost for the entire lifetime, so the payback period is about half as short. It can be, but it is impossible to secure profitability through the economy at the scale of 3MWh and 5MWh. If the price of the electricity market falls by 50%, the payback period will be three years longer in P1 mode and two years longer in P2 and P3 modes.

Field study of 5kW class PEMFC system (5kW급 고분자전해질 연료전지 시스템 실증연구)

  • Lee, SooJae;Choi, Dae Hyun;Jun, HeeKwon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.87.1-87.1
    • /
    • 2011
  • The residential Fuel Cell system has high efficiency of 85% with transferring natural gas to electrical power and heat, directly and it is a friendly environmental new technology in that $CO_2$ emission can reduce 40% compared with conventional power generator and boiler. The residential fuel cell system consists of two main parts which have electrical and hot storage units. The electrical unit contains a fuel processor, a stack, an inverter, a control unit and balance of plant(BOP), and the cogeneration unit has heat exchanger, hot water tank, and auxiliaries. 5kW class fuel process was developed and tested from 2009, it was evaluated for long-term durability and reliability test including with improvement in optimal operation logic. Stack development was crried out through improvement of design and evaluation protocol. Development of system controller was successfully accomplished through strenuous efforts and original control logic was optimized in 5kW class PEMFC system. In addition, we have been focused on development of system process and assembly technology, which bring about excellent improvement of reliability of system. The 5kW class PEMFC system was operated under dynamic conditions for 1,000 hours and it showed a good performance of total efficiency and durability.

  • PDF

An Economic Feasibility Study on Power Plant Construction and Operation Using Real Options (실물옵션을 활용한 발전소 건설 타당성 분석)

  • Yun, Won-Cheol;Sonn, Yang-Hoon;Kim, Suduk
    • Environmental and Resource Economics Review
    • /
    • v.12 no.2
    • /
    • pp.217-244
    • /
    • 2003
  • As energy industry is undergoing a rapid structural changes, economic feasibility analysis based on the conventional discounted cash flow (DCF) method has limitations to incorporate management's flexibilities. We present a real options pricing method (ROPM) which can be applied to an energy sector as an alternative. In order to examine the usefulness of ROPM, this study compares the result of DCF method applied to the investment of cogeneration power plant with that based on the ROPM incorporating the value of real of options inherent in the project. The simulation results show that the value of investment opportunities improves using ROPM compared to that with the conventional DCF methods. Therefore, a specific project which appears to be unprofitable from the conventional point of view could be, actually, an economically feasible one based on ROPM method, when properly incorporating the management's flexibilities inherent in the project.

  • PDF

Study on Local Buckling of District Heating Pipes Using Limit State Design (한계상태 설계법을 이용한 지역난방 열배관의 국부좌굴 연구)

  • Kim, Joo-Yong;Lee, Sang-Youn;Ko, Hyun-Il;Cho, Chong-Du
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1829-1836
    • /
    • 2010
  • The district heating system distributes the heat generated from a cogeneration plant to wider locations. In this process, the district heating pipe (DHP) is subjected to internal and external loadings. The internal loadings are generally caused by the operating conditions such as water temperature and internal pressure. Frictional interactions between the pipes and the soil contribute to the external loadings. Thus, investigation of the mechanisms of failure of DHPs will help to guarantee both mechanical stability and heating efficiency. In this study, we investigate the local buckling of DHPs using limit state design (LSD). Two methods are considered: the use of the limit state for the width-thickness ratio and the use of the limit state for the strain. The results are used to confirm that the DHP is stable under local buckling. Finally, we suggest a minimum preheating temperature for avoiding local buckling.