• Title/Summary/Keyword: Coefficient of reliability

Search Result 1,619, Processing Time 0.031 seconds

Development of Korean Osteoarthritis Impact Measurement Scale(KAIMS) : from data collection to item development in the first study (한국형 골관절염영향측정도구 개발 - 자료수집에서 1차 문항개발까지 -)

  • Yi, Seung-Ju;Kim, Yeon-Ju
    • Journal of Korean Physical Therapy Science
    • /
    • v.19 no.1
    • /
    • pp.17-25
    • /
    • 2012
  • Purpose : The aim of this study was from data collection to item development in the first study before developing a valid and reliable instrument reflecting Korean's own language expression and culture. Methods : The fist survey was 140 osteoarthritis(OA) patients in 2 Cites was studied from November to December 2009. Open-ended questionnaire was decided 39 items from the first open survey. Questionnaire on the Korean Osteoarthritis Impact Measurement Scale(KAIMS) was recruited 2 professors and 5 physical therapists. Second survey was applied to 133 OA patients. Results : OA patients's average age${\pm}$standard deviation was $66.08{\pm}11.10$ years. The internal consistency reliability of 3 items. As estimated by Cronbach's alpha coefficient(${\alpha}$), was high(range, 0.86~0.96). 0.43~0.91 ${\alpha}$ coefficient for the internal consistency reliability of item-each scale was also high. However, item-discriminant validity on 3 items was low(${\alpha}$, 0.92~0.97). The construct validity by factor analysis was a little low. Conclusion : This study revealed that we confirmed a generation for 39 items on KAIMS reflecting Korean's own language expression and culture. Also, those of reliability were a little high. And, we will have to study the last instrument development (3rd study) by more subjects in the future.

  • PDF

Intertester and Intratester Reliability of Tape Measurement on Lower Extremities (줄자를 이용한 하지부피 측정시 부위별 검사자간, 검사자내 신뢰도 측정)

  • Kim, Seng-Jung;Yang, Hoi-Song;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.7 no.1
    • /
    • pp.38-45
    • /
    • 2000
  • Tape measurement for evaluating edema is frequently used by clinicians. The primary purpose of this study is to determine the intertester and intratester reliability of tape measurement carried out by two physical therapists on lower extremities. The intertester and intratester reliability of six anatomical landmarks measurements were determined in six healthy subjects. The measurements were taken in five sessions by each tester. The intraclass correlation coefficients (2,1) were between .87 and .99 for intertester reliability. Intratester reliability was .93 and .99 for A tester and .82 and .99 for B tester. The average range of variation was .13 to .54 in six landmarks. The reliability of six volume measurements was very high. These results support the use tape measurement as a reliable tool for measuring limb girth.

  • PDF

Reliability of the Korean Version of Tampa Scale for Kinesiophobia for Temporomandibular Disorders

  • Park, In Hee;Jang, Ji Hee;Chung, Jin Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.43 no.2
    • /
    • pp.34-40
    • /
    • 2018
  • Purpose: The aim of this study was to translate the original English version of tampa scale for kinesiophobia for temporomandibular disorders (TSK-TMDs) for cultural equivalency into Korean language and to evaluate the reliability of the Korean version of the TSK-TMD among symptom free subjects. Methods: The original version of TSK-TMD was translated and cross-culturally adapted following international guidelines. A total 90 subjects (50 women, 40 men) were participated to fill out the questionnaire. The internal consistency and test-retest reliability with a one- or two-week time interval were evaluated. Results: The internal consistency of TSK-TMD of the original and the modified 12-item TSK-TMD were 0.866, and 0.858, respectively using the Cronbach's alpha coefficient. And the internal consistency of activity avoidance (AA) and somatic focus (SF) subscale were 0.838 and 0.807 assessed with Cronbach's alpha indicating excellent reliability. Test-retest reliability of the original TSK-TMD measured by the intra-class correlation coefficient (ICC) was 0.764, and coefficients value of the 12-question TSK-TMD was 0.752. Test-retest reliability of AA subscale was 0.722 and SF subscale was 0.677 measured by ICC. Conclusions: The Korean version of the TSK-TMD questionnaire was found to be a reliable instrument and successfully translated to Korean language. There are no significant differences between overall and modified version of TSK-TMD. It can be used as a valuable instrument for the analyses of the psychosocial aspects of the TMD patients in Korea.

Comparison of Vendor-Provided Volumetry Software and NeuroQuant Using 3D T1-Weighted Images in Subjects with Cognitive Impairment: How Large is the Inter-Method Discrepancy?

  • Chung, Jieun;Kim, Hayoung;Moon, Yeonsil;Moon, Won-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.2
    • /
    • pp.76-84
    • /
    • 2020
  • Background: Determination of inter-method differences between clinically available volumetry methods are essential for the clinical application of brain volumetry in a wider context. Purpose: The purpose of this study was to examine the inter-method reliability and differences between the Siemens morphometry (SM) software and the NeuroQuant (NQ) software. Materials and Methods: MR images of 86 subjects with subjective or objective cognitive impairment were included in this retrospective study. For this study, 3D T1 volume images were obtained in all subjects using a 3T MR scanner (Skyra 3T, Siemens). Volumetric analysis of the 3D T1 volume images was performed using SM and NQ. To analyze the inter-method difference, correlation, and reliability, we used the paired t-test, Bland-Altman plot, Pearson's correlation coefficient, intraclass correlation coefficient (ICC), and effect size (ES) using the MedCalc and SPSS software. Results: SM and NQ showed excellent reliability for cortical gray matter, cerebral white matter, and cerebrospinal fluid; and good reliability for intracranial volume, whole brain volume, both thalami, and both hippocampi. In contrast, poor reliability was observed for both basal ganglia including the caudate nucleus, putamen, and pallidum. Paired comparison revealed that while the mean volume of the right hippocampus was not different between the two software, the mean difference in the left hippocampus volume between the two methods was 0.17 ml (P < 0.001). The other brain regions showed significant differences in terms of measured volumes between the two software. Conclusion: SM and NQ provided good-to-excellent reliability in evaluating most brain structures, except for the basal ganglia in patients with cognitive impairment. Researchers and clinicians should be aware of the potential differences in the measured volumes when using these two different software interchangeably.

Reliability of the Functional Gait Assessment in Patients With Stroke (뇌졸중 환자에 대한 기능적 보행평가의 신뢰도)

  • Won, Jong-Im;Yu, Kyung-Hoon
    • Physical Therapy Korea
    • /
    • v.18 no.1
    • /
    • pp.64-73
    • /
    • 2011
  • After stroke, many people have problems with balance during movement. Balance is essential for the optimal functioning of the locomotor system and the performance of many activities of daily living. The Functional Gait Assessment (FGA) is a clinical tool for evaluating balance ability during walking. The test consists of ten tasks, seven tasks of the Dynamic Gait Index and three additional tasks. The purpose of this study was to evaluate the reliability and internal consistency of data obtained with the Korean version of the FGA when used with people after suffering a stroke. One-hundred participants, at least three months poststroke and able to walk at least six meters with or without a walking aid, participated in the study (age range=30~83 years; $mean{\pm}SD=58.8{\pm}10.9$). Two physical therapists and two physical therapy students rated the FGA. Intrarater and interrater reliability of the FGA were assessed using kappa statistic and intraclass correlation coefficients (2,1). The internal consistency of the FGA was assessed using the Cronbach alpha. The Cronbach alpha was good (${\alpha}$=.86~.93). The intrarater (intraclass correlation coefficient=.92~.95) and interrater reliability (intraclass correlation coefficient=.91, .95) of the total scores administered by the therapists and students were good, whereas the reliability for single item scores when administered by the physical therapists was moderate to good (kapa value=.42~.97). This study found that intrarater and interrater reliability for total FGA scores and internal consistency were good. Therefore, the Korean version of the FGA can be used as a reliable tool to assess the functional gait performance of patients after stroke.

An Evaluation of the Reliability and Validity of the Automatic Pennation Angle Measuring Program (깃각 자동측정 프로그램의 신뢰도와 타당도 평가)

  • Kim, Jong-Soon
    • PNF and Movement
    • /
    • v.17 no.2
    • /
    • pp.329-337
    • /
    • 2019
  • Purpose: Ultrasound imaging is commonly used to measure the pennation angle of human skeletal muscles in vivo. However, manual assessment of the pennation angle using ultrasound images is subjective and time-consuming and requires a high level of examiner skill. The architectural analysis of human skeletal muscles is thus challenging. Automated approaches using image processing techniques are therefore required to estimate the pennation angle in ultrasound images. The purpose of this study was thus to assess the intra-tester and inter-tester reliability and validity of the pennation angle using an automatic measurement program. Methods: Twenty-two healthy young adults (mean age = 22.55 years) with no medical history of neurological or musculoskeletal disorders voluntarily participated in this study. Ultrasound imaging was used to measure the pennation angle of the gastrocnemius muscle at rest. One examiner acquired images from all the participants. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC) to estimate reliability. Validity was measured using Pearson's correlation coefficient. Results: The intra-rater reliability was excellent for the automatic pennation angle measuring program and the manual pennation angle assessment method (ICC>0.95). The inter-rater reliability was also excellent for both methods (ICC>0.93). All the correlation coefficients for the automatic pennation angle measuring program and the manual pennation angle assessment method were 0.79, which indicated a significantly positive correlation (p<0.05). Conclusion: Pennation angle measurement using the automatic pennation angle measuring program showed acceptable reliability and validity. This study therefore demonstrated that the automatic measuring program was able to automatically measure the pennation angle of skeletal muscles using ultrasound images, and thus made it easy to investigate skeletal muscle architecture.

Reliability and Concurrent Validity of Korean Version of the Trunk Control Measurement Scale (K-TCMS) for Children with Cerebral Palsy

  • Ko, Jooyeon;Jung, Jeewoon
    • The Journal of Korean Physical Therapy
    • /
    • v.29 no.1
    • /
    • pp.16-26
    • /
    • 2017
  • Purpose: This study was conducted to develop a Korean version of the trunk control measurement scale (TCMS) and examine the reliability and concurrent validity of the K-TCMS in children with cerebral palsy. Methods: Subjects for the study were 23 children with cerebral palsy (CP)(mean age: 84.70 months) recruited from one CP clinic. For the interrater and test-retest reliabilities, four raters (A, B, C, D) measured the K-TCMS two times using video clips with an interval of two weeks. For the concurrent validity, the Korean version of the gross motor function measure (K-GMFM) was chosen. Inter-rater reliability and test-retest reliability of the three K-TCMS subscale (static sitting balance, dynamic sitting balance and dynamic reaching) scores and the total scores were investigated using the intra-correlation coefficient ($ICC_{3,1}$). Spearman's correlation coefficient (r) was calculated to investigate the concurrent validity. Results: The inter-rater reliability of the K-TCMS subscales and total scores were all high ($ICC_{3,1}=0.968-0.992$). For the test-retest reliability, $ICC_{3,1}=0.827-0.962$. The concurrent validity between the K-TCMS's total and three subscale scores and K-GMFM's total score were r=0.600-0.667. Conclusion: The results suggest that the K-TCMS can be used in clinical and research settings as a standardized tool for CP children. The K-TCMS might be also useful for selecting treatment goals and planning interventions for children with cerebral palsy.

Reliability and Convergent Validity of Standing Posture Measurement Using a Mobile Application in Forward Head Posture (전방머리자세 성인을 대상으로 모바일 어플리케이션을 이용한 자세정렬 측정의 신뢰도 및 수렴 타당도 연구)

  • Kang, Hyojeong;Kim, Minkyu;Yang, Hoesong;Lee, Wanhee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.173-180
    • /
    • 2020
  • Purpose : The aim of this study was to assess the intra- and inter-rater reliability and validity of measurements of head, neck, and pelvis posture using a mobile application in subjects with forward head posture. Methods : Forty-eight volunteers (22 men, 26 women) participated in this study. Two raters independently examined whole body picture images in a lateral standing posture with arms crossed using a CA-Smart Posture Reminder (CA-SPR), and a rater took and calculated posture images twice to assess reliability. We measured five parameters: craniovertebral angle 1 (CVA1), anterior shoulder translation (AST), pelvic tilt (PT), knee angle (KA), and ankle angle (AA) in the subject's sagittal plane using CA-SPR. We examined whole spine X-ray images in the same position to assess validity. We measured four variables in the subjects: CVA2, translation distance (AHT), anterior pelvic plane (APP), and sacral slope (SS). The intra- and inter-rater reliability were calculated using the intraclass correlation coefficient (ICC). Convergent validity was calculated using Pearson's correlation coefficient. Results : The intra-rater reliability (ICC=.889 -.989) and inter-rater reliability (ICC=.800 -.980) were excellent for all variables measured using CA-SPR. The variables measured using CA-SPR and X-ray were significantly positively correlated (r=.623, p<.01). However, the correlation of the variables in the pelvis was not statistically significant. Conclusion : This study shows that a mobile application (CA-SPR) is a useful tool for measuring head and neck posture in subjects with forward head posture. However, further study is needed to measure pelvic variables when using a mobile application.

The Reliability of the K-PEQ(Korean Prosthesis Evaluation Questionnaire) in Lower Extremity Amputees (절단장애인을 위한 한국어 의지평가 설문지의 신뢰도)

  • Seong, Woo-Sung;Kim, Jang-Hwan;Jeong, Dong-Hun
    • Journal of Digital Contents Society
    • /
    • v.19 no.7
    • /
    • pp.1405-1412
    • /
    • 2018
  • Korean-PEQ (prosthesis evaluation questionnaire) was developed and verified its validity research but, evaluating its reliability applied to the lower extremity amputees have not been conducted. The aim of this study was to apply the Korean-PEQ for lower extremity amputees to evaluate the reliability. As a result, all of the items responding of Korean-PEQ shown to less than 15% ceiling effect and floor effect. therefore, the results were shown to be appropriate. Korean-PEQ reliability of each region of intra-class coefficient was shown to .719(95% CI .600~.811)~920(95%CI .890~.945) and the inter-region reliability was higher as 0.958. Item internal consistency Cronbach's ${\alpha}$ values are shown as higher .910.

Reliability and Validity of the Korean Version of Melbourne Low-Vision ADL Index (한국판 맬버른 저시력 일상생활지수(Melbourne Low-vision ADL Index: MLVAI)의 신뢰도 및 타당도)

  • Yoo, Yeon Hwan;Park, Ji-Hyuk;Jung, Min-Ye;Park, Hae Yean
    • Therapeutic Science for Rehabilitation
    • /
    • v.7 no.2
    • /
    • pp.51-61
    • /
    • 2018
  • Objective: The purpose of this study was performed to modify the performance-based assessment tool, Melbourne Low-Vision ADL Index (MLVAI) had been developed in Australia to suit the Korea culture to verify the reliability and validity. Methods: The subjects were only over the age of 20 living in communities, 26 with low-vision and 42 normal persons. The Korean MLVAI was completed through the expert translation verification and validation of the configuration tool. The validity of the Korean MLVAI was established through the content, discriminant, and convergent validity. Also, the reliability was analyzed through internal consistency reliability for the items, test-retest, and interrater reliability. Results: The Content Validity Index(CVI) was more than .78. There was a statically significant low in low-vision. Also, there was a statically significant low in low-vision. The convergent validity was determined the correlation coefficient of .751 analyzing LVQOL and Korean MLVAI total score, had a significant correlation(p<.05). Cronbach's ${\alpha}$ coefficient indicated an internal consistency of .983(p<.05). Test-retest reliability had a high, significant correlation of .976 and interrater reliability had a high, an intraclass correlation coefficient of .91(p<.05). Conclusion: The results of this study mean that the Korean MLVAI which was modified to fit the Korean is the ADL assessment tool with both validity and reliability. Based on this study, the Korean MLVAI can be used as a useful ADL assessment for OT interventions in low vision.