Statistical reliability in the sensory evaluation measures the agreement of judgements for several observers. Kendall's coefficient of concordance for multiple rankings. and coefficient of consistence and coefficient of agreement for paired comparisons are frequently used as the standard reliability measures. The main idea and the computational formula of these coefficients in various situations are explained in detail with some real (cloth designing) examples. Moreover a user-friendly computer program called as MultPair is introduced. We expect that this expository paper and the computer program give a practical help to the researchers who use the sensory evaluation techniques.
International Journal of Internet, Broadcasting and Communication
/
v.10
no.3
/
pp.65-72
/
2018
The purpose of this study was to assess the intra-tester and inter-tester reliability and validity of elbow flexion range of motion using a smart phone used by the general public. Thirty-one general people participated in this study. The range of motion in active elbow flexion was measured with a goniometer and smart phone over two times by two observers. The intra-taster and inter-tester reliability were evaluated using the intraclass correlation coefficient(ICC). The validity was measured by Pearson's correlation coefficient. The intra-observer reliability was good in all measured items ICC>0.900. The inter-observer reliability was high with ICC>0.806. All correlation coefficients of android app and goniometer were greater than 0.868 and showed a significant positive correlation (p<0.01). The range of motion measurement with a smart phone showed acceptable reliability. Therefore, using a smartphone to measure the range of motion of the elbow joint could provide convenience and economic benefits.
In this study, the reliability analysis of internal and external stabilities of Reinforced Soil Walls (RSWs) under static and seismic loads are investigated so that it can help the geotechnical engineers to perform the design more realistically. The effect of various variables such as angle of internal soil friction, soil specific gravity, tensile strength of the reinforcements, base friction, surcharge load and finally horizontal earthquake acceleration are examined assuming the variables uncertainties. Also, the correlation coefficient impact between variables, sensitivity analysis, mean change, coefficient of variation and type of probability distribution function were evaluated. In this research, external stability (sliding, overturning and bearing capacity) and internal stability (tensile rupture and pull out) in both static and seismic conditions were investigated. Results of this study indicated sliding as the predominant failure mode in the external stability and reinforcing rupture in the internal stability. First-Order Reliability Method (FORM) are applied to estimate the reliability index (or failure probability) and results are validated using the Monte Carlo Simulation (MCS) method. The results showed among all variables, the internal friction angle and horizontal earthquake acceleration have dominant impact on the both reinforced soil wall internal and external stabilities limit states. Also, the type of probability distribution function affects the reliability index significantly and coefficient of variation of internal friction angle has the greatest influence in the static and seismic limits states compared to the other variables.
Background: The Sasang constitutional analysis tool (SCAT) is an integrated Sasang constitutional analysis system developed by the Korea Institute of Oriental Medicine. This study aimed to evaluate the reliability of a questionnaire for measuring personality and pathophysiological symptoms that is one of the components of the SCAT. Methods: In this study, data were collected from university students in their twenties. Tests were administered twice, with an interval of 4 weeks between tests. Test-retest data from 176 students were collected and used for analysis. Internal consistency reliability was analyzed by using Cronbach's alpha coefficient, and test-retest reliability was analyzed by using Spearman's rank correlation coefficient. Results: Cronbach's alpha coefficient was 0.788 for personality, 0.511 for eating habits, 0.718 for digestion, 0.667 for heat- or cold-wise penchant, and 0.612 for water ingestion. Spearman's rank correlation coefficients, which were used to assess correlations between test and retest results, ranged from 0.444 to 0.828. Conclusion: The internal consistency and test-retest reliability of the SCAT questionnaire were found to be satisfactory.
Purpose: The aim of this study was to examine the validity and reliability on Psychometric Arthritis Impact Measurement Scale-Short Form (AIMS-SF) in patients with knee osteoarthritis(OA). Methods: The sample consisted of 62 patients who had received physical therapy at the physical therapy units of the Andong Medical Center, Sungso Hospital, Ahn Orthopedic Surgery Clinic, and St. Luke Clinic in Andong city in June 2006. Questionnaire on the AIMS-SF was recruited by 5 physical therapists. The internal structure and reliability of the scales were evaluated by means of item-internal consistency(Cronbach's alpha coefficient: ${\alpha}$), item-discriminant validity, Pearson's relation coefficient. To explore construct validity we conducted a principal component factor analysis with varimax rotation analysis. The criterion for factor extraction was an eigenvalue >1.0. Results: 62 OA patients's an average $age{\pm}standard$ deviation was $53.8{\pm}14.4$ years (range: $40{\sim}81$ yr). The internal consistency reliability of 11 items, as estimated by Cronbach's ${\alpha}$ coefficient, was high ranging $0.60{\sim}0.78$ (except for 0.40 for mobility level and -0.48 for mood). The internal consistency reliability of item-each scale was also high $0.82{\sim}0.93$ (except for 0.48 for mood). Of 11 items, the item-discriminant validity on 6 items was high (${\alpha}$ coefficient range: $0.11{\sim}0.25$), however, others (0.57 for tension level, 0.48 for arthritis pain, 0.41 for walking and bending, and 0.40 for work) were a little low. The construct validity by factor analysis was a little low. Conclusion: In conclusion, the results reported here confirm the validity and reliability of the AIMS-SF in patients with OA of the knee. The Collection of information on health status using this instrument was acceptable to patients. A further prospective multi-center study will be necessary to prove the construct validity.
Journal of Korean Tunnelling and Underground Space Association
/
v.21
no.6
/
pp.875-885
/
2019
This paper is aimed to suggest the coefficient of variation of the total load on the segment lining and the coefficient of variation of earth pressure in reliability based design of shield tunnel. For this purpose, the statistical characteristics of weathered soil and weathered rock were calculated by analyzing the site survey data of the domestic urban section. The coefficient of variation could be estimated by applying these values to Terzaghi's theory using MCS technique. As a result, the coefficient of variation of rock load for weathered soil and weathered rock was 0.08~0.14. The coefficient of variation for the total load acting on the tunnel was LC1 = 0.38, LC2 = 0.33, and LC3 = 0.37. The proposed coefficients of variation can be used in the reliability-based design of shield tunnel segments.
Purpose: The purpose of the current study was to determine the intra- and inter-rater reliability of muscle thickness measurement of the TA using ultrasonography (US) conducted at different inward pressures of approximately 0.5 kg, 1.0 kg, and no pressure control. Methods: Twenty healthy subjects were recruited for this study. Two different examiners measured the thicknesses of the dominant TA of each subject randomly to assess the intra- and inter-rater reliability. The measurement values were analyzed using the intra-class correlation coefficient (ICC) with a 95% confidence interval, standard error of measurement, minimal detectable change, and coefficient of variance. Results: All intra-rater reliability ICC values showed high reliability above 0.9. Inter-rater reliability ICC values showed high reliability above 0.9 with 0.5 and 1.0 kg of inward pressure. In contrast, Inter-rater reliability ICC values showed poor reliability (0.23) with no pressure control of inward pressure. Conclusion: The findings showed that maintaining consistent inward pressure is essential for reliable results when the muscle thickness of the TA is measured by different examiners in a clinical setting.
Kim, Bum-Su;Lim, Jung-Hwa;Lee, Min-Hee;Yun, Young-Ju
The Journal of the Society of Korean Medicine Diagnostics
/
v.17
no.1
/
pp.29-44
/
2013
Objectives This study is aimed at assessing the reliability of the Pattern identification questionnaire (PIQ) developed by Korea Institute of Oriental Medicine and examining the validity of the PIQ by comparing the pattern identification scores of different groups. Methods We conducted a survey of 258 participants (79 teachers and 179 graduate students at one School of Korean Medicine) using self-reported questionnaire and all the samples were retested. The test-retest reliability was assessed by Kappa coefficient(${\kappa}$) and Pearson correlation coefficient. Also we compared the differences in pattern identification scores according to sex, age and occupation. Results 1. One of 116 questions are impossible to calculate; 22 of them (18.97%) scored under 0.4 in ${\kappa}$; 90(77.59%) ranged from 0.4 to 0.8 in ${\kappa}$; and three questions (3.58%) scored 0.8 or over in ${\kappa}$. 2. Pearson correlation coefficients between test score and retest score of all pattern identification items are 0.4 or over. 3. The mean score for pattern identification in women was generally higher than that in men, particularly in patterns of blood-deficiency, blood-stasis, yang-deficiency and kidney disease. 4. The mean score for pattern identification in the graduate student group was generally higher than that in the teacher group. Conclusion In test-retest reliability, the PIQ showed relatively high reliability. The mean pattern identification score showed differences in regards to retaining knowledge about Korean medicine. Therefore, future research involving modification of questionnaire items and confirming the validity of this questionnaire is required.
Journal of the Korean Academy of Child and Adolescent Psychiatry
/
v.33
no.3
/
pp.67-72
/
2022
Objectives: This study investigated the reliability and validity of the Korean version of the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) Level 2 Cross-Cutting Symptom Measure-Patient-Reported Outcomes Measurement Information System (PROMIS)-Depression and the Irritability for parents of children aged 6-17 years. Methods: Participants were 190 children diagnosed with depressive disorder (n=14), anxiety disorder (n=21), attention-deficit/hyperactivity disorder (ADHD; n=111), ADHD with anxious depression (n=13), and tic disorder with somatic symptoms (n=31). Patients were 8-15 years of age. The participants' mothers completed the Korean versions of the DSM-5 Level 2 Cross-Cutting Symptom Measure-PROMIS Depression and Irritability (Affective Reactivity Index, ARI), and the Korean Child Behavior Checklist (K-CBCL). Using these data, we calculated the reliability coefficient and examined the concurrent and discriminant validity of the PROMIS Depression and the Irritability (ARI) scales for assessing depression and irritability in children. Results: The reliability coefficient of the PROMIS Depression scale (Cronbach's α) was 0.93. The correlation coefficient with the K-CBCL DSM emotional problem score was 0.71. The PROMIS Depression scale significantly discriminated children with depressive disorders from those with other conditions. The reliability coefficient of the Irritability (ARI) scale was 0.91, suggesting its high reliability. Conclusion: Our results suggest that the Korean version of the DSM-5 Level 2 Cross-Cutting Symptom Measure for Depression and Irritability Scales for parents of children aged 6-17 years is reliable and valid and may be an efficient alternative to the K-CBCL.
The purpose of the study was to test the reliability and validity of the Korean version of Pittsburgh Sleep Quality Index (PSQI-K) and to examine the cutoff point of the PSQI-K for screening insomnia among young adults. The subjective quality and patterns of sleep in 64 participants were measured using PSQI-K and Fitbit Charge 3TM. The properties of the instrument were analyzed using Cronbach's alpha coefficient for the internal consistency reliability, factor analysis for the construct validity, and Spearman's rho correlation coefficient for the correlation between the PSQI-K total scores and Fitbit tracker scores. The Cronbach's alpha coefficient of the PSQI-K was 0.69. The Spearman's rho correlation coefficient between the PSQI-K and Fitbit tracker was higher than 0.67. A cutoff point of ≥6.0 had a sensitivity of 0.93 and a specificity of 0.84. In conclusion, the PSQI-K is a reliable and valid instrument to evaluate sleep disturbance in Korean young adults.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.