• Title/Summary/Keyword: Coefficient Of Performance

Search Result 4,665, Processing Time 0.026 seconds

Study on the Aerodynamic Performance of a Cross-Flow Fan for the Various Design Factors of an Indoor Room Air-Conditioner (룸에어콘 실내기의 설계인자 변화에 따른 관류홴의 공력성능 연구)

  • Kim, J.K.;Jeong, K.J.
    • Journal of Power System Engineering
    • /
    • v.9 no.3
    • /
    • pp.33-38
    • /
    • 2005
  • The aerodynamic performance of a cross-flow fan is strongly influenced by the various design factors of a rear-guider and a stabilizer. The purpose of this paper is to investigate the effects of a rear-guider and a stabilizer on the aerodynamic performance of a cross-flow fan. The design factors considered in this paper are a rear-guider clearance, a stabilizer clearance, and a stabilizer setup angle, respectively. This experiment was carried out with a constant revolution number of 700 rpm in a cross-flow fan installed in the fan tester. The static pressure, flowrate, torque, and revolution number were measured in this paper. Also, the pressure coefficient and the efficiency were analysed according to the various assembly conditions using a stabilizer setup angle, a stabilizer clearance, and a rear-guider clearance in the indoor room air-conditioner.

  • PDF

An Investigation on the Torque Converter Characteristics at Various Operating Conditions (작동 조건 변화에 대한 토크 컨버터의 성능 특성 분석)

  • Jang, Wook-Jin;Lee, Chin-Won;Lim, Won-Sik;Park, Yeong-Il;Lee, Jang-Moo
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.678-683
    • /
    • 2000
  • The one-dimensional performance model of a torque converter has been widely used to analyze and predict the performance and dynamic behavior of a torque converter. But this model doesn't include the information of the operating fluid properties. Therefore, to precisely predict dynamic performance of a torque converter, the effect of operating conditions must be considered through experimental coefficients such as friction loss coefficient and shock loss coefficient. And these coefficients cannot be achieved without experiments or internal flow analysis. In this study, the effects of varying material properties of operating fluid according to various operating temperatures are clarified with flow analysis of a torque converter. And these results are verified by comparing with those of performance experiment.

  • PDF

Computer simulation for the performance analysis of automobile air conditioning system (자동차용 에어컨 시스템의 성능해석을 위한 컴퓨터 시뮬레이션)

  • 이건호;유정열;정종대;최규환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.202-216
    • /
    • 1998
  • A computer simulation for the performance analysis of automobile air conditioning components is carried out for the various operating conditions. The automobile air conditioning system consists of laminated type evaporator, swash plate type compressor, parallel flow type condenser, externally equalized thermostatic expansion valve and receiver drier. The overall heat transfer coefficient and the pressure drop in laminated type evaporator were obtained through experiments. In parallel flow type condenser, the performance analysis computer program using the empirical equation for heat transfer coefficient has been developed and the results are compared with experimental results. A model for matching the performance analysis programs of respective components .of automobile air conditioning system is introduced. Further, the effects of varying condenser size and refrigerant charge on the performance of automobile air conditioning system are discussed clearly.

  • PDF

A Review on the Performance of Fin-and-Tube Heat Exchangers Under Frosting and Defrosting Conditions

  • Kim, Yong-Chan;Lee, Ho-Seong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.3
    • /
    • pp.152-157
    • /
    • 2005
  • This paper reviews the literature on the performance of fin-and-tube heat exchangers under frosting and defrosting conditions. The effects of frosting and defrosting on the following parameters were discussed: frost growth, overall heat transfer coefficient, surface roughness, and surface characteristics on the heat exchanger. Comparisons of the experimental results and empirical correlations that were obtained from open literature were presented. In addition, a review of the defrosting methods was conducted.

Electronic Questionnaire of Organizational Citizenship, Job Satisfaction and Their Relationship to Performance Quality for Physical Education Teachers in the Western Region - KSA

  • Hesham Sayed Ahmed Abdalfatah
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.2
    • /
    • pp.227-236
    • /
    • 2023
  • The research aims to identify the degree of the organizational citizenship, satisfaction and performance quality of the teachers and relationship between organizational citizenship, job satisfaction and performance quality for physical education teachers . The researcher used the descriptive method, The participants were (195) teachers. The researcher conducted the research main study in the period from 05/12/2022 to 30/12/2022 use the website to distribute and collect the questionnaire: https://www.surveymonkey.com. The researcher used the computer in the statistical processing, using the SPSS statistical program, and the following methods: Mean, SD, percentages, Correlation Coefficient, Alpha Cronbach coefficient, differences Indicator using chi2 . Conclusions: There is high degree of organizational citizenship behavior practices, job satisfaction and performance quality for some teachers at the schools. Recommendation the importance of enhancing the organizational citizenship behavior in schools, according to the positive effects of these behaviors on the individual and group performances.

A Study on the Performance Characteristics of the 2-D Centrifugal Turbomachinery (2차원 원심식 터보기계의 성능특성에 관한 연구)

  • 최민선;김춘식;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.43-51
    • /
    • 1994
  • The design technique of turbo pumps has been developed due to an increasing demand from related industrial fields. But infant stage of turbomachinery in the domestic industry needs more fundamental design method. Among various types of pumps, centrifugal pump was chosen because of its wide industrial application. It is difficult to decide the correct specification of centrifugal impeller, because of its complex flow analysis at the inlet, passage and outlet. This study is limited on the impeller blade design and its related performance analysis.

  • PDF

Incremental Best Relay Selection System with Outdated CSI in Rayleigh Fading Channels (레일레이 페이딩 채널에서 CSI 지연을 갖는 증가 최적 릴레이 선택 시스템)

  • Kim, Nam-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.17-23
    • /
    • 2012
  • Recently, for spectral efficiency and power saving, an incremental best relay selection of a cooperative diversity scheme is proposed. However during the best relay selection process, there may exist a delay between channel estimation and actual data transmission. Consequently, this delay causes outdated channel state information (CSI). We analytically derive the effect of the outdated CSI to an incremental best relay selection diversity scheme. It is noted that the system performance deteriorates with decreasing the value of the correlation coefficient sensitively. When the correlation coefficient reduces from 1 to 0.9, the most performance degradation is denoted. However, the performance degradation is diminished with decreasing the correlation coefficient.

Performance Evaluation and Convergence Analysis of a VEDNSS LMS Adaptive Filter Algorithm

  • Park, Chee-Hyun;Hong, Kwang-Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.2E
    • /
    • pp.64-68
    • /
    • 2008
  • This paper investigates noise reduction performance and performs convergence analysis of a Variable Error Data Normalized Step-Size Least Mean Square(VEDNSS LMS) algorithm. Adopting VEDNSS LMS results in higher system complexity, but noise is reduced providing fast convergence speed Mathematical analysis demonstrates that tap coefficient misadjustment converges. This is confirmed by computer simulation with the proposed algorithm.

Evaluation of Power Performance by Anemometer on WTGS (풍력발전기 너셀에 장착된 풍속계를 이용한 출력성능 평가)

  • Kim, Soo-Sang;Park, Se-Kwang
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.303-310
    • /
    • 2012
  • We carried out the power performance evaluation for 1.5 MW${\times}$2 by using anemometer installed on WTGS(Wind Turbine Generator System) in the wind farm at Shi-hwa bang-a-mu-ri. In this paper, we compared and analyzed the performance of guaranteed output and measured output of WTGS which includes output curve, output coefficient, AEP(Annual Energy Product) and availability, etc.. The power performance of WTGS was optimized in the low wind speed sections(3 m/s ~ 10 m/s) and the measured output was more produced by AEP 109 % and availability 112 % than the guaranteed output. In addition, we could also cut the high cost of testing WTGS performance by using anemometer as a substitute for weather mast.

Heat transfer coefficient measurement in the Blockage channel with Repeated Jet Impingement (반복된 제트 충돌을 갖는 내부 유로의 평균 열전달 계수 측정)

  • Park, Seoung Duck;Lee, Ki Seon;Kim, Sug Bum;Jo, Yong Hwa;Jeon, Chang Soo;Kwak, Jea Su;Huh, Jae-Sung
    • Journal of Aerospace System Engineering
    • /
    • v.2 no.4
    • /
    • pp.7-12
    • /
    • 2008
  • Averaged heat transfer coefficients were measured in a turbine blade internal cooling passage model with three blockage walls. Each blockage wall was equipped with 9 staggered holes or slots in order to create different shaper of repeated jet impingement. The effect of jet shape on the averaged heat transfer coefficient was studied by the copper-thermocouple method and three Reynolds number of 10,000, 20,000, and 30,000 were tested. Results showed that the repeated stagger jets could increase the averaged heat transfer coefficient by at least 9 times compared to the smooth channel cases. Due to the large pressure drop induced by the repeated jet impingement, the thermal performance was less than 1 for all cases and decreased as the Reynolds number increased. Among the tested cases, the widest slot showed the best thermal performance. The measurement results showed that the thermal performance of the heat transfer augmentation by repeated stagger jets could be improved by altering the jet shape, and other shape of impingement jet will be studied in near future.

  • PDF