• Title/Summary/Keyword: Code tracking

Search Result 224, Processing Time 0.022 seconds

Knowledge Modeling and Database Construction for Human Biomonitoring Data (인체 바이오모니터링 지식 모델링 및 데이터베이스 구축)

  • Lee, Jangwoo;Yang, Sehee;Lee, Hunjoo
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.6
    • /
    • pp.607-617
    • /
    • 2020
  • Human bio-monitoring (HBM) data is a very important resource for tracking total exposure and concentrations of a parent chemical or its metabolites in human biomarkers. However, until now, it was difficult to execute the integration of different types of HBM data due to incompatibility problems caused by gaps in study design, chemical description and coding system between different sources in Korea. In this study, we presented a standardized code system and HBM knowledge model (KM) based on relational database modeling methodology. For this purpose, we used 11 raw datasets collected from the Ministry of Food and Drug Safety (MFDS) between 2006 and 2018. We then constructed the HBM database (DB) using a total of 205,491 concentration-related data points for 18,870 participants and 86 chemicals. In addition, we developed a summary report-type statistical analysis program to verify the inputted HBM datasets. This study will contribute to promoting the sustainable creation and versatile utilization of big-data for HBM results at the MFDS.

Numerical Analysis of Wave Transformation of Bore in 2-Dimensional Water Channel and Resultant Wave Loads Acting on 2-Dimensional Vertical Structure (2차원수조내에서 단파의 변형과 구조물에 작용하는 단파파력에 관한 수치해석)

  • Lee, Kwang Ho;Kim, Chang Hoon;Kim, Do Sam;Hwang, Young Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5B
    • /
    • pp.473-482
    • /
    • 2009
  • This study numerically discusses wave forces acting on a vertical wall such as breakwaters or revetments, subjected to incident undular or turbulent bores. Due to the complex hydrodynamics of bore, its wave forces have been predicted, mainly through laboratory experiments. Numerical simulations in this paper were carried out by CADMAS-SURF(CDIT, 2001), which is based on Navier-Stokes momentum equations and VOF method (Hirt and Nichols, 1981) for tracking free water surface. Its original source code was also partly revised to generate bore in the numerical water channel. Numerical raw data computed by CADMAS-SURF included great strong spike phenomena that show the abrupt jumps of wave loads. To resolve this undesired noise of raw data, the band-pass filter with the frequency of 5Hz was utilized. The filtered results showed reasonable agreements with the experimental results performed by Matsutomi (1991) and Ramsden (1996). It was confirmed that CADMASSURF can be applied to the design of coastal structures against tsunami bores. In addition, the transformation process and propagation speed of bores in the same 2-d water channel were discussed by the variations of water level for time and space. The numerical results indicated that the propagation speed of bore was changed due to the nonlinear interactions between negative and reflected waves.

Monte Carlo Simulations of Detection Efficiency and Position Resolution of NaI(TI)-PMT Detector used in Small Gamma Camera (소형 감마카메라 제작에 사용되는 NaI(TI)- 광전자증배관 검출기의 민감도와 위치 분해능 특성 연구를 위한 몬테카를로 시뮬레이션)

  • Kim, Jong-Ho;Choi, Yong;Kim, Jun-Young;Im, Ki-Chun;Kim, Sang-Eun;Choi, Yeon-Sung;Joo, Kwan-Sik;Kim, Young-Jin;Kim, Byung-Tae
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.67-76
    • /
    • 1997
  • We studied optical behavior of scintillation light generated in NaI(TI) crystal using Monte Carlo simulation method. The simulation was performed for the model of NaI(TI) scintillator (size: 60 mm ${\times}$ 60 mm ${\times}$ 6 mm) using an optical tracking code. The sensitivity as a function of surface treatment (Ground, Polished, Metal-0.95RC, Polished-0.98RC, Painted- 0.98RC) of the incident surface of the scintillator was compared. The effects of NaI(TI) scintillator thickness and the refractive index of light guide optically coupling between the NaI(TI) scintillator and photomultiplier tube (PMT) were simulated. We also evaluated intrinsic position resolution of the system by calculating the spread of scintillation light generated. The sensitivities of the system having the surface treatment of Ground, Polished, Metal-0.95RC, Polished-0.98RC and Painted-0.98RC were 70.9%, 73.9%, 78.6%, 80.1% and 85.2%, respectively, and the surface treatment of Painted-0.98RC allowed the highest sensitivity. As increasing the thickness of scintillation crystal and light guide, the sensitivity of the system was decreased. As the refractive index of light guide increases, the sensitivity was increased. The intrinsic position resolution of the system was estimated to be 1.2 mm in horizontal and vertical directions. In this study, the performance of NaI(TI)-PMT detector system was evaluated using Monte Carlo simulation. Based on the results, we concluded that the NaI(TI)-PMT detector array is a favorable configuration for small gamma camera imaging breast tumor using Tc-99m labeled radiopharmaceuticals.

  • PDF

A Development of Facility Web Program for Small and Medium-Sized PSM Workplaces (중·소규모 공정안전관리 사업장의 웹 전산시스템 개발)

  • Kim, Young Suk;Park, Dal Jae
    • Korean Chemical Engineering Research
    • /
    • v.60 no.3
    • /
    • pp.334-346
    • /
    • 2022
  • There is a lack of knowledge and information on the understanding and application of the Process Safety Management (PSM) system, recognized as a major cause of industrial accidents in small-and medium-sized workplaces. Hence, it is necessary to prepare a protocol to secure the practical and continuous levels of implementation for PSM and eliminate human errors through tracking management. However, insufficient research has been conducted on this. Therefore, this study investigated and analyzed the various violations in the administrative measures, based on the regulations announced by the Ministry of Employment and Labor, in approximately 200 small-and medium-sized PSM workplaces with fewer than 300 employees across in korea. This study intended to contribute to the prevention of major industrial accidents by developing a facility maintenance web program that removed human errors in small-and medium-sized workplaces. The major results are summarized as follows. First, It accessed the web via a QR code on a smart device to check the equipment's specification search function, cause of failure, and photos for the convenience of accessing the program, which made it possible to make requests for the it inspection and maintenance in real time. Second, it linked the identification of the targets to be changed, risk assessment, worker training, and pre-operation inspection with the program, which allowed the administrator to track all the procedures from start to finish. Third, it made it possible to predict the life of the equipment and verify its reliability based on the data accumulated through the registration of the pictures for improvements, repairs, time required, cost, etc. after the work was completed. It is suggested that these research results will be helpful in the practical and systematic operation of small-and medium-sized PSM workplaces. In addition, it can be utilized in a useful manner for the development and dissemination of a facility maintenance web program when establishing future smart factories in small-and medium-sized PSM workplaces under the direction of the government.