• Title/Summary/Keyword: Code selection

Search Result 261, Processing Time 0.026 seconds

Performance and structural analysis of a radial inflow turbine for the organic Rankine cycle (유기랭킨사이클용 반경류 터빈의 성능 및 구조 해석)

  • Kim, Do-Yeop;Kim, You-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.484-492
    • /
    • 2016
  • The turbine is an important component and has a significant impact on the thermodynamic efficiency of the organic Rankine cycle. A precise preliminary design is essential to developing efficient turbines. In addition, performance analysis and structural analysis are needed to evaluate the performance and structural safety. However, there are only a few exclusive studies on the development process of the radial inflow turbines for the organic Rankine cycle (ORC). In this study, a preliminary design of the ORC radial inflow turbine was performed. Subsequently, the performance and structural analysis were also carried out. The RTDM, which was developed as an in-house code, was used in the preliminary design process. The results of the performance analysis were found to be in good agreement with target performances. Structural analysis of the designed turbine was also carried out in order to determine whether the material selection for this study is suitable for the flow conditions of the designed turbine, and it was found that the selected aluminum alloy is suitable for the designed turbine. However, the reliability of the preliminary design algorithms and numerical methods should be strictly verified by an actual experimental test.

Static Timing Analysis Tool for ARM-based Embedded Software (ARM용 내장형 소프트웨어의 정적인 수행시간 분석 도구)

  • Hwang Yo-Seop;Ahn Seong-Yong;Shim Jea-Hong;Lee Jeong-A
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.11 no.1
    • /
    • pp.15-25
    • /
    • 2005
  • Embedded systems have a set of tasks to execute. These tasks can be implemented either on application specific hardware or as software running on a specific processor. The design of an embedded system involves the selection of hardware software resources, Partition of tasks into hardware and software, and performance evaluation. An accurate estimation of execution time for extreme cases (best and worst case) is important for hardware/software codesign. A tighter estimation of the execution time bound nay allow the use of a slower processor to execute the code and may help lower the system cost. In this paper, we consider an ARM-based embedded system and developed a tool to estimate the tight boundary of execution time of a task with loop bounds and any additional program path information. The tool we developed is based on an exiting timing analysis tool named 'Cinderella' which currently supports i960 and m68k architectures. We add a module to handle ARM ELF object file, which extracts control flow and debugging information, and a module to handle ARM instruction set so that the new tool can support ARM processor. We validate the tool by comparing the estimated bound of execution time with the run-time execution time measured by ARMulator for a selected bechmark programs.

Sensitivity Analysis of Depletion Parameters for Heat Load Evaluation of PWR Spent Fuel Storage Pool (경수로 사용후핵연료 저장조 열부하 평가를 위한 연소조건 인자 민감도 분석)

  • Kim, In-Young;Lee, Un-Chul
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.4
    • /
    • pp.237-245
    • /
    • 2011
  • As necessity of safety re-evaluation for spent fuel storage facility has emphasized after the Fukushima accident, accuracy improvement of heat load evaluation has become more important to acquire reliable thermal-hydraulic evaluation results. As groundwork, parametric and sensitivity analyses of various storage conditions for Kori Unit 4 spent fuel storage pool and spent fuel depletion parameters such as axial burnup effect, operation history, and specific heat are conducted using ORIGEN2 code. According to heat load evaluation and parametric sensitivity analyses, decay heat of last discharged fuel comprises maximum 80.42% of total heat load of storage facility and there is a negative correlation between effect of depletion parameters and cooling period. It is determined that specific heat is most influential parameter and operation history is secondly influential parameter. And decay heat of just discharged fuel is varied from 0.34 to 1.66 times of average value and decay heat of 1 year cooled fuel is varied from 0.55 to 1.37 times of average value in accordance with change of specific power. Namely depletion parameters can cause large variation in decay heat calculation of short-term cooled fuel. Therefore application of real operation data instead of user selection value is needed to improve evaluation accuracy. It is expected that these results could be used to improve accuracy of heat load assessment and evaluate uncertainty of calculated heat load.

Adaptive Migration Path Technique of Mobile Agent Using the Metadata of Naming Agent (네이밍 에이전트의 메타데이터를 이용한 이동 에이전트의 적응적 이주 경로 기법)

  • Kim, Kwang-Jong;Ko, Hyun;Lee, Yon-Sik
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.3
    • /
    • pp.165-175
    • /
    • 2007
  • The mobile agent executes a given task by which the agent code moves to the server directly. Therefore, node migration method becomes an important factor which impact on the whole performance of distributed system. In this paper, we propose an adaptive migration path technique of mobile agent using the metadata of naming agent. In this proposed technique, node selection for migration depends on the content of referenced metadata, and the reliability of migrated information is determined by the metadata updating method and cooperative operations of individual agents in multi-agents system. For these, we design the metadata using by the number of hit documents, hit ratio, node processing time and network delay time, and describe the methods for creating, using and updating metadata for which determine the adaptive node migration path of mobile agent according to the cooperation of individual agents and number of hit documents using by designed metadata. And results of evaluated performance for proposed adaptive migration path technique through the proper experiment and analysis gain rate of high effective information earning, because of high hit ratio(72%) about of fathered documents by case of applying metadata move to the 13 nodes. But, in case of non-applying metadata is hit ratio(46%) of gathered documents and rate of effective information earning about of 26 nodes is 36.8%.

  • PDF

The Design Method of GNSS Signal Using the Analysis Result of Receiver Performance (수신 성능 분석을 이용한 위성항법 신호 설계 방안)

  • Jin, Mi-Hyun;Choi, Heon-Ho;Kim, Kap-Jin;Park, Chan-Sik;Ahn, Jae-Min;Lee, Sang-Jeong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.6C
    • /
    • pp.502-511
    • /
    • 2012
  • As the importance of GNSS system increases, the necessity of independent system is increased also. When the independent GNSS system is required, GNSS signal design is necessary with requirement definition. This paper suggests the design method of GNSS signal using the analysis result of receiver performance. First, the candidates are defined based on the design elements. Then the receiver performance of the candidates is analyzed based on the performance evaluation parameters. The weights of performance evaluation parameter are defined in order to consider the receiver performance in a various aspects. Finally, the calculation of normalized performance evaluation parameters and weights are derived to obtain the compared value for signal selection. Spreading code, modulation method and carrier frequency are considered as design parameters. Also, correlation width, DLL PLL thermal noise jitter, frequency bandwidth and side lobe peak ratio are considered as performance evaluation parameters. And positioning performance, robustness to noise, bandwidth efficiency are considered as the performance aspects. This paper analyzes the performance of each candidate using software based simulator and suggest the method to compare objectively the performance of each candidates.

Effect of Grid, Turbulence Modeling and Discretization on the Solution of CFD (격자, 난류모형 및 이산화 방법이 유동해석 결과에 미치는 영향)

  • Park, Dong-Woo;Yoon, Hyun-Sik
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.4
    • /
    • pp.419-425
    • /
    • 2014
  • The current work investigated the variation of numerical solutions according to the grid number, the distance of the first grid point off the ship surface, turbulence modeling and discretization. The subject vessel is KVLCC. A commercial code, Gridgen V15 and FLUENT were used the generation of the ship hull surface and spatial system and flow computation. The first part of examination, the effect of solutions were accessed depending on the grid number, turbulence modeling and discretization. The second part was focus on the suitable selection of the distance of the first grid point off the ship surface: $Y_P+$. When grid number and discretization were fixed the same value, the friction resistance showed differences within 1 % but the pressure resistance showed big differences 9 % depending on the turbulence modeling. When $Y_P+$ were set 30 and 50 for the same discretization, friction resistance showed almost same results within 1 % according to the turbulence modeling. However, when $Y_P+$ were fixed 100, friction resistance showed more differences of 3 % compared to $Y_P+$ of 30 and 50. Whereas pressure resistance showed big differences of 10 % regardless of turbulence modeling. When turbulence modeling and discretization were set the same value, friction, pressure and total resistance showed almost same result within 0.3 % depending on the grid number. Lastly, When turbulence modeling and discretization were fixed the same value, the friction resistance showed differences within 5~8 % but the pressure resistance showed small differences depending on the $Y_P+$.

Effect of Ozone Treatment for Safety Improvement of Fresh Vegetable Juice (녹즙의 위생화를 위한 오존처리의 효과)

  • Cho, Jae-Min;Kwon, Sang-Chul;Tu, Gi;Jeong, Jae-Hyun;Lee, Kyung-Haeng
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.5
    • /
    • pp.612-617
    • /
    • 2009
  • Fresh vegetable juice is a non-heat treated product and the only step to reduce microbial growth is washing. Therefore, the materials for fresh vegetable juice including Angelica keiskei, Brassica loeracea var. acephala, and Daucus carota L. were treated by ozone after the first washing process and investigated for microbial and chemical changes. The number of the total aerobic bacteria in materials after selection step were $8.2{\times}10^5{\sim}5.0{\times}10^6\;CFU/g$, which was a higher contamination level than the limit of Korea food code ($10^5\;CFU/g$). However, after the 1st washing process and ozone treatment, the total aerobic bacterial number was reduced to $4.7{\times}10^4{\sim}6.7{\times}10^4\;CFU/g$, which showed 2 log microbial reduction. After the 2nd washing step followed by ozone treatment, there was no difference in microbial number. The number of colifroms in the materials of fresh vegetable juice were $8.0{\times}10^3{\sim}3.5{\times}10^3\;CFU/g$ initially but showed $1.5{\times}10^2{\sim}3.0{\times}10^2\;CFU/g$ after the ozone treatment (1 log reduction). On the other hand, there was no changes in the contents of ascorbic acid, flavonoids, polyphenols, minerals (cadmium and lead) during all processes. In addition, no color changes were observed during washing process. Therefore, ozone treatment in the materials of fresh vegetable juice decreased the microbial numbers. Also, chemical characteristics of ozone treated sample were not different when compared with control.

A Study on Lambertian Color Segmentation and Canny Edge Detection Algorithms for Automatic Display Detection in CamCom (저속 카메라 통신용 자동 디스플레이 검출을 위한 Lambertian 색상 분할 및 Canny Edge Detection 알고리즘 연구)

  • Han, Jungdo;Said, Ngumanov;Vadim, Li;Cha, Jaesang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.5
    • /
    • pp.615-622
    • /
    • 2018
  • Recent advancements in camera communication (CamCom) technology using visible light exploited to use display as an luminance source to modulate the data for visible light data communication. The existing display-CamCom techniques uses the selected region of interest based camera capturing approach to detect and decode the 2D color coded data on display screen. This is not effective way to do communicate when the user on mobility. This paper propose the automatic display detection using Lambertian color segmentation combined with canny edge detection algorithms for CamCom in order to avoid manual region of interest selection to establish communication link between display and camera. The automatic display detection methods fails using conventional edge detection algorithms when content changes dynamically in displays. In order to solve this problem lambertian color segmentation combined with canny edge detection algorithms are proposed to detect display automatically. This research analysed different algorithms on display edge recognition and measured the performance on rendering dynamically changing content with color code on display. The display detection rate is achieved around 96% using this proposed solutions.

Cost Comparison of PWR and PHWR Nuclear Power Plants in Korea

  • Kim, Chang-Hyo;Chung, Chang-Hyun;So, Dong-Sub
    • Nuclear Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.263-274
    • /
    • 1979
  • A statistical approach is used to investigate the relative economic advantages of pressurized water reactor (PWR) and pressurized heavy water reactor (PHWR-CANDU) nuclear power plants for hypothetical 900Mwe systems with the throwaway fuel cycle to be built in the Republic of Korea. Power cost is decomposed into the cost components related to the plant capital, operation and maintenance, working capital requirements and fuel cycle operation. The calculation of construction cost is performed with the modified version of computer code ORCOST, and the modified POWERCO-50 is used to evaluate the cost components. Most of economic parameters are treated as statistical variables, each being given with a certain range. Through a random sampling procedures. the probability histograms on unit plant construction costs and power generating costs are obtained. The power cost probability histograms of the PWR and the PHWR plants overlap considerably, and the power costs of two systems appear to be almost same with the PHWR power cost being 0.4mil1/kwh lower compared with 39.4 mills/kwh for the PWR plant (July 1986 US-dollars). When a construction period of PHWR plant is longer by one year than that of PWR plant, there is no difference in the unit power cost of two plants. This comparison leads to no definite conclusion on the cost advantage of the PWR plant versus the PHWR plant. We conclude that the selection issue of nuclear power plants in Korea still remains an open question and that future effort to solve this question should be made toward economic quantification of those factors such as technology transfer and localization.

  • PDF

A Preliminary Study on the Evaluation of Internal Exposure Effect by Radioactive Aerosol Generated During Decommissioning of NPPs by Using BiDAS (BiDAS를 적용한 원전 해체 공정 시 발생되는 방사성 에어로졸의 내부피폭 영향평가 사전 연구)

  • Song, Jong Soon;Lee, Hak Yun;Kim, Sun Il
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.4
    • /
    • pp.473-478
    • /
    • 2018
  • Radioactive aerosol generated in cutting and melting work during the NPP decommissioning process can cause internal exposure to body through workers' breath. Thus, it is necessary to assess worker internal exposure due to the radioactive aerosol during decommissioning. The actually measured value of the working environment is needed for accurate assessment of internal exposure, but if it is difficult to actually measure that value, the internal exposure dose can be estimated through recommended values such as the fraction of amount of intake and the size of particles suggested by the International Committee on Radiological Protection (ICRP). As for the selection of particle size, this study applied a value of $5{\mu}m$, which is the size of particles considering the worker recommended by the ICRP. As for the amount of generation, the amount of intake was estimated using data on the mass of aerosol generated in a melting facility at a site in Kozloduy, Bulgaria. In addition, using these data, this study calculated the level of radioactivity in the worker's body and stool and conducted an assessment of internal exposure using the BiDAS computer code. The internal exposure dose of Type M was 0.0341 mSv, that of Type S was 0.0909 mSv. The two types of absorption showed levels that were 0.17% and 0.45% of the domestic annual dose limit, respectively.