• Title/Summary/Keyword: Code generator

Search Result 426, Processing Time 0.027 seconds

Physical Layer Wireless Network Security Through Channel Coding (채널 부호화를 통한 물리계층 무선 네트워크 보안 기술)

  • Asaduzzaman, Asaduzzaman;Kong, Hyung-Yun;Kim, Gun-Seok;Kim, Nae-Soo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2007.05a
    • /
    • pp.989-992
    • /
    • 2007
  • In this paper we introduce a new paradigm of physical layer security for wireless network. Existing security protocols like internet's transport layer security protocol has some security flaws that skilled hackers could exploit. Motivated from this point we introduce a new security protocol that works in physical layer which is much less vulnerable to hackers than any other higher layers. In our proposal, we incorporate the proposed security protocol within channel coding as channel coding is an essential part of wireless communication. We utilize the flexibility to choose a generator matrix (or generator polynomial) of a particular code that selects the code words as a core of our protocol. Each pair of wireless node will select a unique generator using their security key before they started to communicate with each other.

Thermal Hydraulic Analysis Methodology for PWR Nuclear Power Plant Steam Generators (원전 가압경수로 증기발생기 열유동 해석법)

  • Choi, Seok-Ki;Nam, Ho-Yun;Kim, Eui-Kwang;Kim, Hyung-Nam;Jang, Ki-Sang;Hong, Sung-Yull
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.463-468
    • /
    • 2001
  • This paper presents the methodology for thermal hydraulic analysis of Pressurized Water Reactor (PWR) steam generators. Topics include porous media approach, governing equations, physical models and correlations for solid-to-fluid interaction and heat transfer and numerical solution scheme. Some details about the ATHOS3 code currently used widely for thermal hydraulic analysis of PWR steam generators in the industry are presented. The ATHOS3 code is applied to the thermal hydraulic analysis of steam generator in the Korea YGN 3&4 nuclear power plant and the computed results are presented.

  • PDF

A study on the generation of JIT compiler using JBURG (JBURG를 이용한 JIT컴파일러 생성에 관한 연구)

  • Kang Kyung-Woo
    • The KIPS Transactions:PartA
    • /
    • v.12A no.1 s.91
    • /
    • pp.59-64
    • /
    • 2005
  • In this paper, we propose a method of generating a JIT compiler using JBURG. JBURG is a tool of generating the code generator using bottom-up tree pattern matching for Java. Our method can be derived from some relations over tree patterns. The proposed scheme is more efficient than JBURG because we can avoid unfruitful tests with the smaller site of the scheme. Furthermore, the relevant analyses needed for this proposal are largely achieved at non- compile time, which secures actual efficiency at compilation time.

BCCOMICS: Baryon-Cold dark matter COsMological Initial Condition generator for Small-scale structures

  • Ahn, Kyungjin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.35.3-36
    • /
    • 2016
  • Density and velocity perturbations in scales most relevant for the first galaxy formation are strongly affected by large-scale density perturbations, velocity-divergence perturbations and the baryon-cold dark matter (CDM) streaming velocities. Even at redshifts as high as z~200, this mode-mode coupling imprints a significant impact on the small-scale perturbations, at the wavenumber k >${\sim}100Mpc^{-1}$, as was calculated in our recent work. This implies that cosmological initial conditions based on the usual linear theory is no longer valid in these scales. We present a new cosmological initial condition generator, BCCOMICS, which generates initial conditions for the cold dark matter (CDM) and baryons in scales most relevant for the first galaxy formation. BCCOMICS is based on the linear perturbation theory including the mode-mode coupling terms, and generates cosmological initial conditions for the SPH-basded code GADGET and the AMR-based code ENZO. We also present our preliminary result on the cosmic variance of the first galaxy formation, studied by using BCCOMICS.

  • PDF

Linear Corrector Overcoming Minimum Distance Limitation for Secure TRNG from (17, 9, 5) Quadratic Residue Code

  • Kim, Young-Sik;Jang, Ji-Woong;Lim, Dae-Woon
    • ETRI Journal
    • /
    • v.32 no.1
    • /
    • pp.93-101
    • /
    • 2010
  • A true random number generator (TRNG) is widely used to generate secure random numbers for encryption, digital signatures, authentication, and so on in crypto-systems. Since TRNG is vulnerable to environmental changes, a deterministic function is normally used to reduce bias and improve the statistical properties of the TRNG output. In this paper, we propose a linear corrector for secure TRNG. The performance of a linear corrector is bounded by the minimum distance of the corresponding linear error correcting code. However, we show that it is possible to construct a linear corrector overcoming the minimum distance limitation. The proposed linear corrector shows better performance in terms of removing bias in that it can enlarge the acceptable bias range of the raw TRNG output. Moreover, it is possible to efficiently implement this linear corrector using only XOR gates, which must have a suitable hardware size for embedded security systems.

A Fixed-point Digital Signal Processor Development System Employing an Automatic Scaling (자동 스케일링 기능이 지원되는 고정 소수집 디지털 시그날 프로세서 개발 시스템)

  • 김시현;성원용
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.3
    • /
    • pp.96-105
    • /
    • 1992
  • The use of fixed-point digital signal processors, such as the TMS 320C25, requires scaling of data at each arithmetic step to prevent overflows while keeping the accuracy. A software which automatizes this process is developed for TMS 320C25. The programmers use a model of a hypothetical floating-point digital signal processor and a floating-point format for data representation. However, the program and data are automatically translated to a fixed-point version by this software. Thus, the execution speed is not sacrificed. A fixed-point variable has a unique binary-point location, which is dependent on the range of the variable. The range is estimated from the floating-point simulation. The number of shifts needed for arithmetic or data transfer step is determined by the binary-points of the variables associated with the operation. A fixed-point code generator is also developed by using the proposed automatic scaling software. This code generator produces floating-point assembly programs from the specifiations of FIR, IIR, and adaptive transversal filters, then floating-point programs are transformed to fixed-point versions by the automatic scaling software.

  • PDF

ESTABLISHMENT OF A SEVERE ACCIDENT MITIGATION STRATEGY FOR AN SBO AT WOLSONG UNIT 1 NUCLEAR POWER PLANT

  • Kim, Sungmin;Kim, Dongha
    • Nuclear Engineering and Technology
    • /
    • v.45 no.4
    • /
    • pp.459-468
    • /
    • 2013
  • During a station blackout (SBO), the initiating event is a loss of Class IV and Class III power, causing the loss of the pumps, used in systems such as the primary heat transporting system (PHTS), moderator cooling, shield cooling, steam generator feed water, and re-circulating cooling water. The reference case of the SBO case does not credit any of these active heat sinks, but only relies on the passive heat sinks, particularly the initial water inventories of the PHTS, moderator, steam generator secondary side, end shields, and reactor vault. The reference analysis is followed by a series of sensitivity cases assuming certain system availabilities, in order to assess their mitigating effects. This paper also establishes the strategies to mitigate SBO accidents. Current studies and strategies use the computer code of the Integrated Severe Accident Analysis Code (ISAAC) for Wolsong plants. The analysis results demonstrate that appropriate strategies to mitigate SBO accidents are established and, in addition, the symptoms of the SBO processes are understood.

QUASI-CYCLIC SELF-DUAL CODES WITH FOUR FACTORS

  • Hyun Jin Kim;Whan-Hyuk Choi;Jung-Kyung Lee
    • Korean Journal of Mathematics
    • /
    • v.32 no.3
    • /
    • pp.485-496
    • /
    • 2024
  • In this study, we examine ℓ-quasi-cyclic self-dual codes of length ℓm over 𝔽2, provided that the polynomial Xm - 1 has exactly four distinct irreducible factors in 𝔽2[X]. We find the standard form of generator matrices of codes over the ring R ≅ 𝔽q[X]/(Xm - 1) and the conditions for the codes to be self-dual. We explicitly determine the forms of generator matrices of self-dual codes of lengths 2 and 4 over R.

Numerical study on the reactive flow in Gas Generator (가스발생기 내부 유동 특성에 관한 수치 연구)

  • Yu Jungmin;Lee Changjin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.198-202
    • /
    • 2005
  • Gas generator is the equipment to produce high enthalpy gas used to generate sufficient power to operate turbine and pump system for propellant feeding in liquid rocket engine. Since the limit in operating temperature is imposed due to turbine blade, the gas generator has to be operated at the temperature far below stoichiometric maintaining fuel rich combustion. In this research, fundamental study was performed to understand the non-equilibrium combustion process with in-house code and CFD-ACE as well.

  • PDF

Finite Element Analysis for Wall Thinned Steam Generator Tubes (감육된 증기발생기 전열관의 유한요소 해석)

  • Seong, K.Y.;Ahn, S.H.;Nam, K.W.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.38-44
    • /
    • 2006
  • Failure assessment of steam generator tube are very important for the integrity of energy plants. In pipes of energy plants, sometimes, the local wall thinning may result from severe erosion-corrosion damage. Recently, the effects of local wall thinning on fracture strength and fracture behavior of piping system have been well studied. In this paper, the elasto-plastic analysis is performed by FE code ANSIS on steam generator tube with wall thinning. We evaluated the failure mode, fracture strength and fracture behavior from FE analysis. It was possible to predict the crack initiation point by estimating true fracture ductility under multi-axial stress conditions at the center of the thinned area.

  • PDF