• Title/Summary/Keyword: Code distribution

Search Result 1,274, Processing Time 0.026 seconds

Buckling and Post buckling Analysis of Composite Plates with Internal Flaws

  • Sreehari, VM;Maiti, DK
    • International Journal of Aerospace System Engineering
    • /
    • v.2 no.2
    • /
    • pp.19-23
    • /
    • 2015
  • This work deals with the study of buckling and post buckling characteristics of laminated composite plates with and without localized regions of damage. The need of a detailed study on Finite Element Analysis of buckling and post buckling of laminated composite structures considering various aspects enhances the interest among researchers. Mathematical formulation is developed for damaged composite plates using a finite element technique based on Inverse Hyperbolic Shear Deformation Theory. This theory satisfies zero transverse shear stresses conditions at the top and bottom surfaces of the plate and provides a non-linear transverse shear stress distribution. Damage modeling is done using an anisotropic damage formulation, which is based on the concept of stiffness change. The structural elements are subjected to in-plane loading. The computer program is developed in MATLAB environment. The numerical results are presented after through validation of developed finite element code. The effect of damage on buckling and post buckling has been carried out for various parameters such as amount of percentage of damaged area, damage intensity, etc. The results show that the presence of internal flaws will significantly affect the buckling characteristics of laminated composite plates. The outcomes and remarks from this work will assist to address some key issues concerning composite structures.

On the Adaptive 3-dimensional Transform Coding Technique Employing the Variable Length Coding Scheme (가변 길이 부호화를 이용한 적응 3차원 변환 부호화 기법)

  • 김종원;이신호;이상욱
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.7
    • /
    • pp.70-82
    • /
    • 1993
  • In this paper, employing the 3-dimensional discrete cosine transform (DCT) for the utilization of the temporal correlation, an adaptive motion sequence coding technique is proposed. The energy distribution in a 3-D DCT block, due to the nonstationary nature of the image data, varies along the veritical, horizontal and temporal directions. Thus, aiming an adaptive system to local variations, adaptive procedures, such as the 3-D classification, the classified linear scanning technique and the VLC table selection scheme, have been implemented in our approach. Also, a hybrid structure which adaptively combines inter-frame coding is presented, and it is found that the adaptive hybrid frame coding technique shows a significant performance gain for a moving sequence which contains a relatively small moving area. Through an intensive computer simulation, it is demonstrated that, the performance of the proposed 3-D transform coding technique shows a close relation with the temporal variation of the sequence to be code. And the proposed technique has the advantages of skipping the computationally complex motion compensation procedure and improving the performance over the 2-D motion compensated transform coding technique for rates in the range of 0.5 ~ 1.0 bpp.

  • PDF

A Study on the Fluid Mixing Analysis for Proving Shell Wall Thinning of a Feedwater Heater (급수가열기 동체 감육 현상 규명을 위한 유동해석 연구)

  • Kim, Kyung-Hoon;Hwang, Kyeong-Mo;Kim, Sang-Nyung
    • Journal of ILASS-Korea
    • /
    • v.9 no.4
    • /
    • pp.24-30
    • /
    • 2004
  • Feedwater flowing tube side of number 5 high pressure feedwatrr heaters was heated by extracting steam from high pressure turbine and draining water from moisture separators and number 6 high pressure feedwater heaters and supplied into steam generators. Because the extracting steam from the high pressure turbine is two phase fluid of high temperature, high pressure, and high speed and flows to inverse direction after impinging to impingement baffle. the shell wall of the number 5 high pressure feedwater heater may be affected by flow accelerated corrosion. On May 14, 1999, Point Beach Nuclear Plant (PBNP) with operating at full power experienced a steam leak from rupture of shell side of number 4B feedwater heater. Also, d domestic nuclear power plant experienced a severe wall thinning of shell side of number 5A and 5B feedwater heaters. This paper describes the fluid mixing analysis study using PHOENICS code in order to get at the root of the shell wall thinning of the feedwater heaters. The sections included in the fluid mixing analysis model are around the number 5h feedwater heater shell including the extracting pipeline. To identify the relation between the local velocities and wall thinning. the local velocities according to the analysis results were compared with the distribution of the shell wall thickness by ultrasonic test.

  • PDF

DYNAMICAL INTERACTION OF SUPERNOVA REMNANT WITH PRE-EXISTING WIND BUBBLE (항성풍 거품 내에서의 초신성 잔해의 동역학적 구조)

  • Choi, Seung-Eon;Cha, Seung-Hun;Gu, Bon-Cheol
    • Publications of The Korean Astronomical Society
    • /
    • v.11 no.1
    • /
    • pp.27-47
    • /
    • 1996
  • We have performed the high resolution computer simulation with 1D spherical hydrodynamic code in order to study the dynamical evolution of supernova ejecta interacting with a pre-existing fast wind structure. The fast wind structure has been calculated with $M_{in}=3{\times}10^{-6}M_{\odot}yr^{-1}$ and ${\upsilon}_{in}=1000km/sec$, which velocity is higher than the critical velocity relating to the initial radiative cooling. The fast wind becomes initially adiabatic. After a shell formation time of ${\sim}4000yrs$, the wind becomes radiative cooling at the shell zone, forming a thin dense radiative shell and an adiabatic wind bubble afterward. When supernova explodes in the wind center at 20,000yrs after the wind evolves, the supernova ejecta, which has a dense distribution of ${\rho}{\propto}r^{-n}$(here we have n = 9), interacts initially with, the understood wind zone, producing forward and reverse shocks. The reverse shock heats the supernova ejecta and its temperature increases. In this study, as the mass of the supernova ejecta is larger than that of the wind shell ($M_{ej}=5M_{\odot}$, $M_{sw}=2M_{\odot}$), we can conform two shell structures: an outer shell by the supernova ejecta and a secondarily shocked wind shell by it. The secondarily shocked wind shell should accelerates in this case to be R-T unstable, consequently producing the knots.

  • PDF

Analysis of Smoke Control According to Jet Fan Location in Straight Long Tunnel (제트 팬 설치 위치에 따른 직선터널 내의 제연해석)

  • Byun, Ju-Suk;Lim, Hyo-Jae;Kang, Shin-Hyung;Lee, Jin-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.9
    • /
    • pp.662-668
    • /
    • 2007
  • In this study, jet fans are installed with 4 cases in the straight long tunnel; inlet-side setup, middle-side setup, outlet-side setup, and dispersion setup. A bus is selected as fired car, of which fire size is 20MW. And fired car locates at 100m, 700m, 1500m position from tunnel inlet, respectively. FLUENT, commercial finite-volume code, is used to analyze the performance. The velocity profile, $CO_2$ concentration, temperature distribution are examined for analysis. Performance of smoke control is compared by the backlayering length. Consequently, inlet-side setup of jet fans is a little more efficient than other cases considering the fire occurrence frequency in tunnel.

Ventilation Analysis According to Jet Fan Location in Curved Long Road Tunnel (제트 팬 위치에 따른 곡선형 장대터널의 환기해석)

  • Byun, Ju-Suk;Kang, Shin-Hyung;Kim, Ji-Sung;Lee, Jin-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.9
    • /
    • pp.669-678
    • /
    • 2007
  • In this study, the ventilation characteristics is investigated numerically of the longitudinal ventilation method in the curved long road tunnel. Numerical work has been conducted for the jet fan location by utilizing the commercial finite-volume code, FLUENT. Configuration of the tunnel is three-lane, 1600 m long, $120m^2$ in area, 3000 m curvature radius. The velocity profile, distribution of mono-dioxide carbon and flow rate of air are examined in the tunnel. Through the analysis, it is found that the difference of ventilation flow rate Is a little by the jet fan location, but tunnel outlet setup (CASEIII) of jet fans is the most efficient concerned with CO concentration.

Thermal-flow Analysis of the Cooling System in the Medicated Water Electrolysis Apparatus (냉이온수기 냉각시스템에 관한 열유동 해석)

  • Jeon, Seong-Oh;Lee, Sang-Jun;Lee, Jong-Chul;Kim, Youn-Jea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.3
    • /
    • pp.33-38
    • /
    • 2011
  • Medicated water electrolysis apparatus, which electrolyzes water into acidic water and alkaline water, was in the spotlight as becoming known the effect of alkaline water. It is known as good for health as removing active oxygen in the human's body and promoting digestion. But, the customers could not get that desired water temperature because these apparatuses are directly connected with a water pipe. So, the cooling system was developed for controlling the temperature of the alkaline water. One of the typical way is to store water in water tank and control the temperature. But, in this way, storing water can be polluted impurities coming from outside. For protecting this pollution, the cooling system based on indirect heat exchange method through phase change between water and ice was developed. In this study, we have calculated efficiency of the cooling system with phase change by experiment and commercial CFD(Computational Fluid Dynamics) code, ANSYS CFX. To consider the effect of latent heat that is generated by melting ice, we have simulated two phase numerical analyses used enthalpy method and found the temperature, velocity, and ice mass distribution for calculating the efficiency of cooling. From the results of numerical analysis, we have obtained the relationship between the cooling efficiency and each design factor.

Coupling of nonlinear models for steel-concrete interaction in structural RC joints

  • Dominguez, Norberto;Perez-Mota, Jesus
    • Coupled systems mechanics
    • /
    • v.3 no.2
    • /
    • pp.195-211
    • /
    • 2014
  • When strong seismic forces act on reinforced concrete structures, their beam-column connections are very susceptible to damage during the earthquake event. The aim of this numerical work is to evaluate the influence of the internal steel reinforcement array on the nonlinear response of a RC beam-column connection when it is subjected to strong cyclic loading -as a seismic load. For this, two specimens (extracted from an experimental test of 12 RC beam-column connections reported in literature) were modeled in the Finite Element code FEAP considering different stirrup's arrays. In order to evaluate the nonlinear response of the RC beam-column connection, the 2D model takes into account the nonlinear thermodynamic behavior of each component: for concrete, a damage model is used; for steel reinforcement, it is adopted a classical plasticity model; in the case of the steel-concrete bonding, this one is considered perfect without degradation. At the end, we show a comparison between the experimental test's responses and the numerical results, which includes the distribution of shear stresses and damage inside the concrete core of the beam-column connection; in the other hand, the effects on the connection of a low and high state of confinement are analyzed for all cases.

Design of Personal Career Records Management and Duistribution using Block Chain (블록체인을 활용한 개인 경력 관리 및 유통 시스템 설계)

  • Bae, Su-Hwan;Shin, Yong-Tae
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.3
    • /
    • pp.235-242
    • /
    • 2020
  • This paper proposes a system that can manage and verify personal career information through a block chain to solve the problem of getting a job by forging an individual's career when hiring employees. Blockchain network uses private network, and inside the block, the user's academic and career information is kept. The functions of the block chain perform the functions of block creation, block internal data retrieval, career and academic verification, which works through chain code. As a result of the performance evaluation of the proposed system, the processing time per transaction was measured at approximately 110 ms and the search time was measured at 10 ms, and it was applied to the actual system to confirm that it was available.

Autonomous Operation Analysis of DC Microgrid based on Droop Control (Droop 제어를 기반으로 한 직류 마이크로그리드의 자율 동작 분석)

  • Lee, Ji-Heon;Kim, Hyun-Jun;Han, Byung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.342-350
    • /
    • 2011
  • This paper describes the autonomous operation analysis of DC microgrid based on droop control. In order to verify the whole system operation, detailed simulation models for wind power generation, solar power generation, and battery were developed with user-defined models programmed with C-code in PSCAD/ EMTDC software. The simulation results confirm that the DC microgrid with droop control make it feasible to provide power to the load with stable manner. Based on simulation results a prototype of DC microgrid was built and tested in the lab to verify the autonomous operation experimentally. The droop control scheme can suppress the circulating current, and offers each unit to be controlled autonomously without any communication link.