• Title/Summary/Keyword: Code distribution

Search Result 1,271, Processing Time 0.026 seconds

Spectral Infrared Signature Analysis of the Aircraft Exhaust Plume (항공기 배기 플룸의 파장별 IR 신호 해석)

  • Gu, Bonchan;Baek, Seung Wook;Yi, Kyung Joo;Kim, Man Young;Kim, Won Cheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.8
    • /
    • pp.640-647
    • /
    • 2014
  • Infrared signature of aircraft exhaust plume is the critical factor for aircraft survivability. To improve the military aircraft survivability, the accurate prediction of infrared signature for the propulsion system is needed. The numerical analysis of thermal fluid field for nozzle inflow, free stream flow, and plume region is conducted by using the in-house code. Weighted Sum of Gray Gases Model based on Narrow Band with regrouping is adopted to calculate the spectral infrared signature emitted from aircraft exhaust plume. The accuracy and reliability of the developed code are validated in the one-dimensional band model. It is found that the infrared radiant intensity is relatively more strong in the plume through the analysis, the results show the different characteristic of the spectral infrared signature along the temperature, the partial pressure, and the species distribution. The continuous spectral radiant intensity is shown near the nozzle exit due to the emission from the nozzle wall.

Study on the Development and Application of Image Viewer System (Image Viewer System의 개발 및 적용에 관한 고찰)

  • Yang, Oh-Nam;Seo, In-Ki;Hong, Dong-Ki;Kwon, Kyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.67-73
    • /
    • 2006
  • Purpose: The number of patients receiving radiotherapy has increased every year and will keep increasing in the future. Therefore, the technique of radiotherapy is developing from day to day, as a result of it, the quantities of image and data used for radiotherapy are also considerably increasing. Therefore, there have been many difficulties in storing, keeping and managing them. Then, we developed and applied this system for improving complicated work process as well as solving these problems with the collaboration Medical Information Team. Materials and Methods: We exported its image at R & V (Record and Verify: Varis vision, Varian, USA) system and planning system after giving some code to be able to access from management system(RO) for department of radiation oncology to PACS. And, we programmed their information by using necessary information among many information included in DICOM head. Results: All images and data generated by our working environment (Simulation CT, L-gram image and internal body structure, DRR, does distribution )were realized at PACS and it became to be possible for clear image to be printed from any computer in department of radiation oncology. Conclusion: It was inevitable to use film during radiotherapy for patients in the past, however, due to the development of this system, film-less system became to be possible. Therefore, the darkroom space and its management cost in relation to the development process disappeared and it became to be unnecessary for spending tangible and intangible financial expense including human resources, time needed for finding film storing space and film and purchasing separate storing equipment for storing images. Finally, we think this system would be very helpful to handle ail complicated processes for radiotherapy and increasing efficiency of overall working conditions.

  • PDF

Investigation of Aircraft Plume IR Signature for Various Nozzle Configurations and Atmospheric Conditions (노즐형상 및 대기조건에 따른 항공기의 플룸 IR 신호 연구)

  • Kang, Dong-Woo;Kim, In-Deok;Myong, Rho-Shin;Kim, Won-Cheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.1
    • /
    • pp.10-19
    • /
    • 2014
  • Nozzle configurations and atmospheric conditions play a significant role in the infrared signature level of aircraft propulsion system. Various convergent nozzles of an unmanned aircraft under different atmospheric conditions are considered. An analysis of thermal flow field and nozzle surface temperature distribution is conducted using a compressible CFD code. It is shown that the IR level in rear direction is considerably reduced in deformed nozzles, whereas the IR level in adjacent azimuth angles is increased in aspect ratios around 6 due to the plume spreading effect caused by high aspect ratio of nozzles. In addition, an analysis of atmospheric transmissivity for various seasons and observation distance is conducted using the LOWTRAN 7 code and subsequently plume IR signature is calculated by considering atmospheric effects. It is shown that the IR signature is reduced significantly in summer season and near the band of carbon dioxide in case of relatively close distance.

Tension Lap Splice Length in High-Strength Concrete Flexural Members (고강도 콘크리트 휨부재의 인장 겹침이음길이에 관한 연구)

  • Lee, Gi-Yeol;Kim, Woo;Lee, Hwa-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.6
    • /
    • pp.753-761
    • /
    • 2009
  • This paper presents the test results of total 24 beam-end specimens to investigate the effect of high-strength concrete and cover thickness on the development resistance capacity in tensile lap splice length regions. Based on bond characteristics that an increase in concrete strength results in higher bond stress and shortening of the transfer length, cracking behavior that thin cover thickness induced a splitting crack easily and brittle crack propagation, current design code that development length provisions as uniform bond stress assumption was investigated apply as it. The results showed that as higher strength concrete was employed, not only development resistance capacity was influenced by cover thickness, but also more sufficient safety factor reserved shorter than the lap splice length provision in current design code. From experimental research results, high-strength concrete development length was not inverse ratio of $\sqrt{f_{ck}}$ but directly inverse of $f_{ck}$, and it is also said that there is a certain limit length of the embedded steel over which the assumption of uniform bond stress distribution is valid specially for high-strength concrete not having a same embed length such as normal-strength concrete in current design criteria hypothesis.

Application of Variance Reduction Techniques for the Improvement of Monte Carlo Dose Calculation Efficiency (분산 감소 기법에 의한 몬테칼로 선량 계산 효율 평가)

  • Park, Chang-Hyun;Park, Sung-Yong;Park, Dal
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.240-248
    • /
    • 2003
  • The Monte Carlo calculation is the most accurate means of predicting radiation dose, but its accuracy is accompanied by an increase in the amount of time required to produce a statistically meaningful dose distribution. In this study, the effects on calculation time by introducing variance reduction techniques and increasing computing power, respectively, in the Monte Carlo dose calculation for a 6 MV photon beam from the Varian 600 C/D were estimated when maintaining accuracy of the Monte Carlo calculation results. The EGSnrc­based BEAMnrc code was used to simulate the beam and the EGSnrc­based DOSXYZnrc code to calculate dose distributions. Variance reduction techniques in the codes were used to describe reduced­physics, and a computer cluster consisting of ten PCs was built to execute parallel computing. As a result, time was more reduced by the use of variance reduction techniques than that by the increase of computing power. Because the use of the Monte Carlo dose calculation in clinical practice is yet limited by reducing the computational time only through improvements in computing power, introduction of reduced­physics into the Monte Carlo calculation is inevitable at this point. Therefore, a more active investigation of existing or new reduced­physics approaches is required.

  • PDF

An efficient 2.5D inversion of loop-loop electromagnetic data (루프-루프 전자탐사자료의 효과적인 2.5차원 역산)

  • Song, Yoon-Ho;Kim, Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.1
    • /
    • pp.68-77
    • /
    • 2008
  • We have developed an inversion algorithm for loop-loop electromagnetic (EM) data, based on the localised non-linear or extended Born approximation to the solution of the 2.5D integral equation describing an EM scattering problem. Source and receiver configuration may be horizontal co-planar (HCP) or vertical co-planar (VCP). Both multi-frequency and multi-separation data can be incorporated. Our inversion code runs on a PC platform without heavy computational load. For the sake of stable and high-resolution performance of the inversion, we implemented an algorithm determining an optimum spatially varying Lagrangian multiplier as a function of sensitivity distribution, through parameter resolution matrix and Backus-Gilbert spread function analysis. Considering that the different source-receiver orientation characteristics cause inconsistent sensitivities to the resistivity structure in simultaneous inversion of HCP and VCP data, which affects the stability and resolution of the inversion result, we adapted a weighting scheme based on the variances of misfits between the measured and calculated datasets. The accuracy of the modelling code that we have developed has been proven over the frequency, conductivity, and geometric ranges typically used in a loop-loop EM system through comparison with 2.5D finite-element modelling results. We first applied the inversion to synthetic data, from a model with resistive as well as conductive inhomogeneities embedded in a homogeneous half-space, to validate its performance. Applying the inversion to field data and comparing the result with that of dc resistivity data, we conclude that the newly developed algorithm provides a reasonable image of the subsurface.

Optical Design of Gradient-Index Objective for Optical Pickup (광 Pickup 용 Gradient-Index 대물렌즈 설계)

  • Park, In-Kyu;Lee, Jong-Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.4
    • /
    • pp.256-263
    • /
    • 2007
  • High NA objective design by using SELFOC materials was studied, and two kinds of objective for optical pick-up were designed. The SELFOC materials have radial gradient index distribution, and it gives additional degree of freedom in optical design. Therefore, we expect that optical design of high NA objective without aspheric surface will be possible. In this study, the variation of ms spot diameter was investigated as a function of quadratic constant and refractive index on axis for various combinations of axial thickness and entrance pupil diameter. For the survey, Code V was used for optimization and evaluation of the objective lenses. The result suggested that larger quadratic constant and higher refractive index on axis could give us better imaging performance for all combinations of axial thickness and pupil diameter. Based on the survey, we designed high NA objectives for DVR. There were two kinds of design solution consisting two spherical SELFOC lenses. The solution I had positive-positive lens configuration with short over-all-length, but it had poor off-axial performance compared with the solution II. The solution II had negative-positive lens configuration with good off-axial imaging performance. But the solution II had some disadvantages, long over-all-length and large diameter of the second lens.

A Monte Carlo Simulation Study of a Therapeutic Proton Beam Delivery System Using the Geant4 Code (Geant4 몬테카를로 코드를 이용한 양성자 치료기 노즐의 전산모사)

  • Shin, Jungwook;Shim, Hyunha;Kwak, Jungwon;Kim, Dongwook;Park, Sungyong;Cho, Kwan Ho;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.18 no.4
    • /
    • pp.226-232
    • /
    • 2007
  • We studied a Monte Carlo simulation of the proton beam delivery system at the National Cancer Center (NCC) using the Geant4 Monte Carlo toolkit and tested its feasibility as a dose verification framework. The Monte Carlo technique for dose calculation methodology has been recognized as the most accurate way for understanding the dose distribution in given materials. In order to take advantage of this methodology for application to external-beam radiotherapy, a precise modeling of the nozzle elements along with the beam delivery path and correct initial beam characteristics are mandatory. Among three different treatment modes, double/single-scattering, uniform scanning and pencil beam scanning, we have modeled and simulated the double-scattering mode for the nozzle elements, including all components and varying the time and space with the Geant4.8.2 Monte Carlo code. We have obtained simulation data that showed an excellent correlation to the measured dose distributions at a specific treatment depth. We successfully set up the Monte Carlo simulation platform for the NCC proton therapy facility. It can be adapted to the precise dosimetry for therapeutic proton beam use at the NCC. Additional Monte Carlo work for the full proton beam energy range can be performed.

  • PDF

Prediction of Salinity Changes for Seawater Inflow and Rainfall Runoff in Yongwon Channel (해수유입과 강우유출 영향에 따른 용원수로의 염분도 변화 예측)

  • Choo, Min Ho;Kim, Young Do;Jeong, Weon Mu
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.3
    • /
    • pp.297-306
    • /
    • 2014
  • In this study, EFDC (Environmental Fluid Dynamics Code) model was used to simulate the salinity distribution for sea water inflow and rainfall runoff. The flowrate was given to the boundary conditions, which can be calculated by areal-specific flowrate method from the measured flowrate of the representative outfall. The boundary condition of the water elevation can be obtained from the hourly tidal elevation. The flowrate from the outfall can be calculated using the condition of the 245 mm raifall. The simulation results showed that at Sites 1~2 and the Mangsan island (Site 4) the salinity becomes 0 ppt after the rainfall. However, the salinity is 30 ppt when there is no rainfall. Time series of the salinity changes were compared with the measured data from January 1 to December 31, 2010 at the four sites (Site 2~5) of Yongwon channel. Lower salinities are shown at the inner sites of Yongwon channel (Site 1~4) and the sites of Songjeong river (Site 7~8). The intensive investigation near the Mangsan island showed that the changes of salinity were 21.9~28.8 ppt after the rainfall of 17 mm and those of the salinity were 2.33~8.05 ppt after the cumulative rainfall of 160.5 mm. This means that the sea water circulation is blocked in Yongwon channel, and the salinity becomes lower rapidly after the heavy rain.

Analysis and Improving ways of Factors affecting the Ill-defined Causes of Death of the Aged in Korea (노인의 불명확한 사망원인진단 관련요인 분석과 개선방안)

  • Park, Sang-Hee;Lee, Tae-Yong
    • Health Policy and Management
    • /
    • v.21 no.2
    • /
    • pp.329-348
    • /
    • 2011
  • This research analyzed 168,010 cases of death of the aged over 65 from 244,867cases of death excluding 7 unknown age cases from 244,874 all age cases of death by using the death data of the National Statistical Office for 2007 to figure out factors affecting the quality of causes of death statistics of the aged and to suggest the ways of improving the quality of death statistics of the aged in korea. This research tried to derive factors affecting ill-defined cause of death category in acordance with WHO's guidelines and to find causes of lowering the accuracy of causes of death statistics of the aged. This research identified the problems of causes of death statistics of the aged by using both demographic characteristics such as sex, age, marital status, educational attainment, residential region, region size and factors of death items as independent variable to find causes of ill-defined cause of death of the aged. Logistic regression analysis was executed to calculate the hazard ratio about the ill-defined causes of death of the aged and multiple regression analysis was conducted to derive factors affecting the ill-defined cause of death by regional groups through using these independent variables such as the component ratio of over age 65, female death rates, doctors insitutions rate, medical institutions rate, attaching rates of death certificate by neighborhood. As a results of this research, R-code was the highest of ill-defined causes of death, accounting for 82.1%, and senility death(R54) of R-code was the highest, accounting for 91.2%. through subdivided order distribution of the ill-defined causes of death of the aged. As ill-defined causes of death by regional groups, attaching rates of death certificate by neighborhood was the most important factor(p<0.05) and also showed regression model's description with 83.8% ($R^2$=83.8%). Furthermore, Jeon-nam was the highest in the regional groups and these regions such as Je-ju, Jeon-buk, Chung-nam were not only attaching the death certificate by neighborhood but also were high at the rate of ill-defined causes of death. Therefore, this research found that both reconsideration about death certificate by neighborhood and education for doctors who write death certificate were needed the most.