• Title/Summary/Keyword: Coaxial air

Search Result 110, Processing Time 0.022 seconds

Numerical Study of CH4/LOx Combustion of Shear-coaxial Injector in High Pressure Combustion Chamber of Liquid Rocket (액체로켓 동축인젝터(CH4/LOx)의 고압 연소실 내 연소 유동장에 대한 수치적 연구)

  • Kim, Jung Eun;Jeung, In-Seuck
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.311-313
    • /
    • 2014
  • High pressure combustion with multiphase--liquid, gas, and supercritical phase--mixtures are widely used technology in the high efficiency liquid propellent rocket engine. This is the typical characteristics differentiate from the combustor of conventional air-breathing engines. Therefore, successful research of high pressure combustion at supercritical condition is essential to develope a high efficiency liquid rocket engine. Numerical studies have been carried out to explore capabilities of numerical method for LOx-CH4 non-premixed flames at high pressure. In this paper, corresponding numerical results are presented and compared with experimental result of MASCOTTE facility.

  • PDF

Measurement on the permittivity and propagation velocity of used insulation oil at UHF Band using time domain reflectometry (TDR을 이용한 극초단파 대역에서 사용 절연유의 유전율과 전파속도 측정)

  • Goo, Sun-Geun;Ju, Hyoung-Jun;Park, Ki-Jun;Han, Ki-Seon;Yoon, Jin-Yul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2011-2014
    • /
    • 2008
  • We measured the permittivity and electromagnetic wave propagation velocity of used insulation oil with wide frequency range including ultra-high frequency by time domain reflectometry. The permittivity or propagation velocity is essential for locating discharge faults of oil filled power transformer. We derived 2.21 as a permittivity and $2.03{\times}10^8 m/s$ as a velocity from the measurement of pulse travelling time along a coaxial line filled with used insulation oil or air. The permittivity measurement system we designed shows high measurement accuracy and the convenience for field use.

Optimization of Microwave Absorbing Performance in Polymer Matrix Composite Laminate (고분자 기기 복합재료 적층판의 전자파 흡수 최적화)

  • 김진봉;김태욱
    • Composites Research
    • /
    • v.14 no.6
    • /
    • pp.38-46
    • /
    • 2001
  • In this study, An optimization code that can design microwave absorbing composite laminates is developed, and 3-layered microwave absorbing composite laminates are developed by optimizing the thickness of each layer. The layers are 3 different composite laminates. Many variables including lay-up angles of electromagnetically orthotropic composite layer can be considered in this code. The developed laminate is composed of an impedance matching layer of glass/epoxy fabric laminate, a glass/epoxy fabric laminate layer containing aluminum filler and carbon/epoxy fabric laminate layer. Permittivities of the materials are obtained using a network analyzer and a coaxial air line.

  • PDF

A study on the Heat Transfer Performance according to Ground Heat Exchanger Types (지중열교환기의 종류에 따른 열전달 성능에 관한 연구)

  • Hwang, SuckHo;Song, Doosam
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.75-80
    • /
    • 2010
  • Generally, ground-source heat pump (GSHP) systems have a higher performance than conventional air-source systems. However, the major fault of GSHP systems is their expensive boring costs. Therefore, it is important issue that to reduce initial cost and ensure stability of system through accurate prediction of the heat extraction and injection rates of the ground heat exchanger. Conventional analysis methods employed by line source theory are used to predict heat transfer rate between ground heat exchanger and soil. Shape of ground heat exchanger was simplified by equivalent diameter model, but these methods do not accurately reflect the heat transfer characteristics according to the heat exchanger geometry. In this study, a numerical model that combines a user subroutine module that calculates circulation water conditions in the ground heat exchanger and FEFLOW program which can simulate heat/moisture transfer in the soil, is developed. Heat transfer performance was evaluated for 3 different types ground heat exchanger(U-tube, Double U-tube, Coaxial).

Performance analysis of Coaxial Propeller for Multicopter Type PAV (Personal Air Vehicle) (멀티콥터형 PAV(Personal Air Vehicle)의 동축반전 프로펠러에 대한 성능해석)

  • Kim, Young Tae;Park, Chang Hwan;Kim, Hak Yoon
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.3
    • /
    • pp.56-63
    • /
    • 2019
  • Performance analyses were performed on a propeller developed for use in a PAV (Personal Air Vehicle) under 600 kg Maximum Take-Off Weight (MTOW). The actuator disc theory and CFD analyses were used to estimate the hovering time with regards to MTOW variation for a given battery weight. The interference induced power factor kint was introduced to account for the effect of flow interference between the propellers and to estimate the performance of counter-rotating propellers. The Maximum Figure of Merit (FM) value of the propeller pitch was determined and the design RPM range for the required power inversely obtained from the CFD results. Previous research indicate that the flight time of large multi-copter is limited by the available battery energy density. Similarly, the propeller pitch settings and spacing are important factors in reducing the kint value.

A study on the exhaust gas recirculation in a MILD combustion furnace by using a Venturi nozzle (MILD 이용한 배기가스 재순환에 관한 연구)

  • Ha, Ji Soo;Shim, Sung Hoon
    • Journal of Energy Engineering
    • /
    • v.22 no.4
    • /
    • pp.413-419
    • /
    • 2013
  • The present study used the MILD combustor, which has coaxial cylindrical tube. The outside tube of the MILD combustor corresponds to the exhaust gas passage and the inner side tube is the furnace passage. A numerical analysis was accomplished to elucidate the characteristics of exhaust gas entrainment toward the inner furnace with the changes of venturi nozzle geometrical parameters, nozzle position, nozzle gap between high pressure air nozzle and venturi nozzle, and with the change of high pressure nozzle inlet velocity. The entrainment flow rate for the case with the high pressure air nozzle attached at the exhaust gas wall has relatively small change with the change of nozzle gap. That for the case with the high pressure air nozzle exposed to the exhaust gas has monotonically increase with the change of nozzle gap. The flow rate ratio of entrainment flow rate has considerably increase tendency with relatively lower air inlet velocity, on the other hand, that with relatively higher air inlet velocity could be seen relatively small increase.

Combustion Characteristics of CH4 Nonpremixed Flame with Recession Distance (메탄 비예혼합 화염의 후퇴거리에 따른 연소특성)

  • Kim, Jun-Hee;Ku, Kun-Woo;Hong, Jung-Goo;Lee, Choong-Won;Kim, In-Su;Cheong, In-Mo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.285-291
    • /
    • 2012
  • A lot of research on the stability of nonpremixed flames has focused on the fuel-nozzle and quarl geometries. Of the work carried out, only a small amount has focused on the stability of the nonpremixed flame according to the recession distance and air-nozzle geometry. Therefore, in this study, a coaxial-diffusion-type gas burner with a swirler is designed for the systematic investigation of the combustion characteristics of a $CH_4$ flame depending on the recession distance and secondary air-nozzle geometry. 1st air is flowed through the swirler, and 2nd air is flowed through each nozzle. It is shown that the secondary air velocity greatly influences the flame length and shape. There is an optimum recession distance for each nozzle for the best combustion efficiency. In this study, it is shown that the optimized recession distance is nearly half the outer diameter of the air-supply nozzle.

Design and fabrication of a RFID Reader Antenna in 900MHz Band (900MHz 대역 RFID 리더기 안테나 설계 및 제작)

  • Kim, Chan-Baek;Park, Seong-Il;Ko, Young-Hyuk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.125-128
    • /
    • 2008
  • In this paper, a stand-type planar antenna of 900MHz RFID band is designed and fabricated. As the proposed antenna is stand-type use of air permittivity, Bandwidth used ground height at rectangle patch structure and coaxial feed line is widen. Also wideband width can solve problem that RFID tag attached to things happens frequency shift keying phenomenon by liquid, special metal, temperature, humidity etc. Bandwidth of fabricated antenna to VSWR less than 2 is satisfied 11.9% at $890MHz{\sim}1000MHz$. And proposed antenna is circular polarization antenna of operating characteristics that axial ratio is less than 2 and gain is 6dBi.

  • PDF

Determination of stress intensity factor by means of ACPD technique for ferromagnetic materials (교류전위차법에 의한 강자성체의 응력확대계수 결정)

  • Lee, Jeong-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.9
    • /
    • pp.1392-1399
    • /
    • 1997
  • In order to determine the Mode I stress intensity factor ($K_1$) experimentally by means of the alternating current potential drop(ACPD) technique, the change in potential drop due to load for a ferromagnetic material containing a two-dimensional surface crack was examined. The cause of the change in potential drop and the effect of the magnetic flux on the change in potential drop were clarified by using the measuring systems with and without removing the magnetic flux from the circumference of the specimen. To remove the magnetic flux, a new measuring system was made by utilizing the characteristic of coaxial transmission line. The change in potential drop in the case without magnetic flux in the air was caused by the change in electromagnetic properties near the crack tip due to magnetization. The relationship between the change in potential drop and the change in $K_I$ was linealized by demagnetization and was found to be independent of the crack length.

Design of a Model Combustor for Studying the Combustion Characteristics of O2/H2 Flames at Supercritical Conditions (O2/H2 화염의 초임계 조건 연소 특성 연구를 위한 모델 연소기 설계)

  • AHN, YEONG JONG;KIM, YOUNG HOO;KWON, OH CHAE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.1
    • /
    • pp.96-104
    • /
    • 2020
  • A model combustor has been designed and fabricated for studying the combustion characteristics of oxygen (O2)/hydrogen (H2) flames under supercritical conditions. The combustor is designed to allow combustion experiments up to 60 bar, the supercritical pressure condition of O2 and H2. Injectors can be replaced to study various types of flames and the combustion chamber is designed to visualize flames by installing optical windows. Through the preliminary tests, including a high-pressure (up to 60 bar) test using air and combustion tests for coaxial jet flames of liquid oxygen (LO2)/gaseous hydrogen (GH2) at elevated pressure, the reliability of the combustor has been demonstrated.