• Title/Summary/Keyword: Coating Inspection

Search Result 99, Processing Time 0.023 seconds

A Study on the Working Clothes in the Changwon National Industrial Complex -Considering Clothing Performance and Motion Factors in Work Places- (창원국가산업공단 근로자들 작업복 착용실태에 관한 연구 -작업분야별 작업복 기능성 및 동작요인 중심으로-)

  • Park, Gin-Ah;Bae, Hyun-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.10
    • /
    • pp.1571-1583
    • /
    • 2008
  • The study aimed to investigate the actual condition of working clothes in the Changwon National Industrial Complex and to analyze the industrial workers' satisfaction with and preference to the working clothes in terms of the clothing performance and work motion factors. 1 major companies in machinery, automotive, industrial engineering, shipbuilding and rolling stock industries located in the industrial complex were selected as the subject firms. Approximately 900 workers responded to the questionnaire designed for the research and the results derived from the research were as follows. (1) The subject employees were divided into 4 work groups, i.e. the $1^{st}$ work group: managerial, general affairs, sales, production planning; the $2^{nd}$ group: quality assurance, material planning and distribution, product inspection; the $3^{rd}$ group: electric, facilities, machinery, vehicles; and the $4^{th}$ group: cutting, pressing, rolling, welding and coating. (2) The significant work environmental factors considered by all work groups were air ventilation, noise and dust factors and in particular, the most dissatisfied factors evaluated by manufacture workers were insulation, noise, dust and vibration. (3) According to the employees' work motion evaluation, the work motion diversity and frequency increased in proportion to the degree of work intensity. Besides, manufacture workers more frequently wore the working clothes even during the off-duty hours comparing to the evaluation of the other work groups. (4) The most important clothing performance factors considered by manufacture work groups were perspiration absorption, stretch, air permeability, tactile sense softness, soil proof in order.

Piezoelectric nanocomposite sensors assembled using zinc oxide nanoparticles and poly(vinylidene fluoride)

  • Dodds, John S.;Meyers, Frederick N.;Loh, Kenneth J.
    • Smart Structures and Systems
    • /
    • v.12 no.1
    • /
    • pp.55-71
    • /
    • 2013
  • Structural health monitoring (SHM) is vital for detecting the onset of damage and for preventing catastrophic failure of civil infrastructure systems. In particular, piezoelectric transducers have the ability to excite and actively interrogate structures (e.g., using surface waves) while measuring their response for sensing and damage detection. In fact, piezoelectric transducers such as lead zirconate titanate (PZT) and poly(vinylidene fluoride) (PVDF) have been used for various laboratory/field tests and possess significant advantages as compared to visual inspection and vibration-based methods, to name a few. However, PZTs are inherently brittle, and PVDF films do not possess high piezoelectricity, thereby limiting each of these devices to certain specific applications. The objective of this study is to design, characterize, and validate piezoelectric nanocomposites consisting of zinc oxide (ZnO) nanoparticles assembled in a PVDF copolymer matrix for sensing and SHM applications. These films provide greater mechanical flexibility as compared to PZTs, yet possess enhanced piezoelectricity as compared to pristine PVDF copolymers. This study started with spin coating dispersed ZnO- and PVDF-TrFE-based solutions to fabricate the piezoelectric nanocomposites. The concentration of ZnO nanoparticles was varied from 0 to 20 wt.% (in 5 % increments) to determine their influence on bulk film piezoelectricity. Second, their electric polarization responses were obtained for quantifying thin film remnant polarization, which is directly correlated to piezoelectricity. Based on these results, the films were poled (at 50 $MV-m^{-1}$) to permanently align their electrical domains and to enhance their bulk film piezoelectricity. Then, a series of hammer impact tests were conducted, and the voltage generated by poled ZnO-based thin films was compared to commercially poled PVDF copolymer thin films. The hammer impact tests showed comparable results between the prototype and commercial samples, and increasing ZnO content provided enhanced piezoelectric performance. Lastly, the films were further validated for sensing using different energy levels of hammer impact, different distances between the impact locations and the film electrodes, and cantilever free vibration testing for dynamic strain sensing.

A Study on the Development and Applicative Estimation of Safety Evaluation Model for Water Supply Pipelines using Quantification Theory Type II (수량화II류이론을 활용한 상수도관로의 안전성 평가 모델 개발 및 적용성 평가 연구)

  • Kim, Kibum;Shin, Hwisu;Seo, Jeewon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.1
    • /
    • pp.59-67
    • /
    • 2016
  • Owing to time and cost constraints, new methods that would make it possible to evaluate the safety of the water supply pipeline in a less time- and cost-consuming manner are urgently needed. In response to this exigency, the present study developed a new statistical model to assess the safety of the water supply pipeline using the quantification theory type II. In this research, the safety of the water supply pipeline was defined as 'a possibility of the pipeline failure'. Quantification analysis was conducted on the qualitative data, such as pipe material, coating, and buried condition. The results of analyses demonstrate that the hit ratio of the quantification function amounted to 77.8% of hit ratio, which was a fair value. In addition, all variables that were included in the quantification function were logically valid and demonstrated statistically significant. According to the results derived from the application of the safety evaluation model, the coefficient of determination ($R^2$) between K-region's water supply pipeline safety and the safety inspection amounted to 0.80. Therefore, these findings provide meaningful insight for the measured values in real applications of the model. The results of the present study can also be meaningfully used in further research on safety evaluation of pipelines, establishing of renewal prioritization, as well as asset management planning of the water supply infrastructure.

The Influence of Fillers (Zeolite, Serpentine and Talc) and their Fineness on Granulation of Sulfate of Potash (광물질(鑛物質)의 종류(種類) 및 입도(粒度)가 황산가리(黃酸加理) 조립(造粒)에 미치는 영향(影響))

  • Lee, Yun-Hwan;Lee, In-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.15 no.3
    • /
    • pp.188-193
    • /
    • 1982
  • Granulation formed from mixture of sulfate of potash (SOP) powder and pulverized silica minerals (Zeolite, Serpentine and Talc) was studied to establish granulation rate and physical properties of granules. These mixtures were granulated in a pan granulator with water and granules of SOP were coated with minerals powder. Mixture of SOP and mineral powder by half (w/w) were increased granulation rate compared with pure SOP powder, and talc was superior to them with SOP. Water was needed about 14% to granulate SOP powder alone, but it decreased by 2% with talc and increased by 4% and 2% with zeolite and serpentine, respectively. Granules of mixture of SOP with zeolite were harder than pure SOP granules but with another minerals powder decreased in hardness. Also breaking rate of granules in vinyl parcel falling from 2m height and abrasion rate of granules by agitation were improved by mixing and coating with zeolite but with the other were of inferior.

  • PDF

Statistical analysis of hazen-williams C and influencing factors in multi-regional water supply system (광역상수도 유속계수와 영향인자에 관한 통계적 분석)

  • Kim, Bumjun;Kim, Gilho;Kim, Hung soo
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.5
    • /
    • pp.399-410
    • /
    • 2016
  • In case of the application of Hazen-Williams C for design, operation or maintenance of water supply system, field situations always should be reflected on the factors. In this study, the relationships between C factors and influencing factors are analyzed using statistical techniques with 174 measured C factor data collected in periodic inspection for safety diagnosis in multi-regional water supply systems. To analyze their relationships, cross analysis, one-way ANOVA, correlation analysis were conducted. Analysis results showed that C factors had high correlations with both of elapsed year and pipe diameter and were relatively highly affected by coating material among influencing factors with the categorical type. On the other hand, elapsed year, pipe diameter and water type were meaningful influencing factors according to the results of multiple regression analysis. The Cluster analysis revealed that C factors had a tendency of being fundamentally classified on the basis of the elapsed year of about 20 years and the pipe diameter of 1500mm. Although C factors were generally greatly affected by elapsed year, size of pipe diameter relatively had an large influence on values of them in case of large diameter pipes. Lastly, It can be suggested that C factor estimation formulas using multiple regression analysis and clustering analysis in this study, can be applied as decision standards of C factor in multi-regional water supply systems.

Development of Auto-spray system to improve the quality of 3D Scanning Quality (3D 스캔 시 품질향상을 위한 스프레이 도포 자동화 장비 개발)

  • Kim, Wonseop;Jo, Jae Heung;Kim, Dongsu;Kim, Donggyoo;Hong, Seokmoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.100-105
    • /
    • 2016
  • The use of 3D scanners has increased gradually according to increasing 3D printer applications. The precision inspection of car parts or electronic components is an important issue not only in the field of mass production, but also in small-scale production. Recently, 3D scanner equipment efficiency and recognition technology has been improved continuously. On the other hand, the spraying time to prepare 3D scanning is time-consuming and has environmental problems. Therefore, an automatic spray system has been in demand by the manufacturing industry. Automatic spray equipment was newly developed for the preparation of a 3D scanner. In this research, the automatic spray system guarantees uniform spray operation. To determine the optimal spray parameters, various spraying methods, solutions and conditions were tested and compared with the experiments. The preparation time for 3D scanning was reduced to 1/10 compared to the manual spraying time, and indicates the optimal spraying conditions through a comparison of various spray coating conditions.

Preparation of Charged Composite Particles for Electrophoretic Display (전기영동 디스플레이용 대전 복합입자의 제조)

  • Na, Hae-Jin;Baek, Jeong-Ju;Kim, Ji-Suk;Kim, Sung-Soo
    • Polymer(Korea)
    • /
    • v.33 no.4
    • /
    • pp.347-352
    • /
    • 2009
  • Charged organic-inorganic composite particles were prepared for the application to electrophoretic display technology such as electronic paper. $TiO_2$ and $Co_3O_4$ particles were used for core particles and were coated with poly(methyl methacrylate) by dispersion polymerization. Composite particles were endowed with charge moiety for electrophoresis; positive charge for $TiO_2$ and negative charge for $Co_3O_4$ composite particles. Scanning electron microscopic results revealed that the charged composite particles have spherical shape. Densities of the composite particles were controlled to be that of medium of electrophoresis. Density of $TiO_2$ particle changed from 4.02 to 1.44 g/$cm^3$ after the polymer coating, and that of $Co_3O_4$ particles changed from 6.11 to 1.49 g/$cm^3$. Urea, melamine, and formaldehyde were used as wall materials for capsule, and microcapsule containing black or white particles inside were prepared by in-situ polymerization. Microcapsule showed the inspection by a video microscope demonstrated the formation of uniform transparent capsules.

Bacterins to Prevent the Contamination of Vbrio vulnificus in the Flounder, Paralichthys olivaceus (넙치에서의 Vbrio vulnificus 오염 방지를 위한 백신 연구)

  • Son Sang Gyu;Kim Myoung Sug;Park Jun Hyo;Yoo Min Ho;Jeong Hyun Do
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • To study the increased resistance in fish against Vibrio vulnificus known as an important agent of vibrio septicemia in human, we analyzed specific and nonspecific immune response in flounder after administration of V. vulnificus bacterins by oral route. It contained the comparison of antibody concentrations in the sera of flounder after oral administration by two different protocols with uncoated heat killed bacterin of V vulnificus (UHKB, 20 mg/kg body weight), i.e., 4 weeks continuously (group 4W) and taking 2 weeks resting period between the 1st and last week of administration (group 1-2-1W). Even though, 1-2-1W group showed significantly increased level of specific antibody in serum, it did not reach to that of 4W group. Certainly, flounder vaccinated twice a week for four weeks (20 mg/kg b.w.) showed increased concentration of specific antibody against V. vulnificus at week 2 after last administration by oral route and maintained throughout the experimental period. It also was confirmed by the increased numbers of specific antibody secreting cells (SASC) in the leukocytes isolated from the splenocytes of the flounder of 4W group at week 1 after last administration until the end of experimental period. However, enteric, acid-resistant film coated heat killed bacterin (ECHB) did not show both greater immune reaction for antibody production and faster elimination of a challenge dose of V. vulnificus compared with those of the UHKB. These results suggested that UHKB administered by oral route was very effective method to prevent the contamination of V vulnificus in flounder, and did not show the increased antigenicity by coating the surface with acid-resistant film.

Optimization for Underwater Welding of Marine Steel Plates (선박용 강판의 수중 용접 최적화에 관한 연구)

  • 오세규
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.20 no.1
    • /
    • pp.49-59
    • /
    • 1984
  • Optimizing investigation of characteristics of underwater welding by a gravity type arc welding process was experimentally carried out by using six types of domestic coated welding electrodes for welding of domestic marine structural steel plates (KR Grade A-1, SWS41A, SWS41B,) in order to develop the underwater welding techniques in practical use. Main results obtained are summarized as follows: 1. The absorption speed of the coating of domestic coated lime titania type welding-electrode became constant at about 60 minutes in water and it was about 0.18%/min during initial 8 minutes of absorption time. 2. Thus, the immediate welding electrode could be used in underwater welding for such a short time in comparison with the joint strength of in-atmosphere-and on-water-welding by dry-, wet-or immediate-welding-electrode. 3. By bead appearance and X-ray inspection, ilmenite, limetitania and high titanium oxide types of electrodes were found better for underwater-welding of 10 mm KR Grade A-1 steel plates, while proper welding angle, current and electrode diameter were 6$0^{\circ}C$, above 160A and 4mm respectively under 28cm/min of welding speed. 4. The weld metal tensile strength or proof stress of underwater-welded-joints has a quadratic relationship with the heat input, and the optimal heat input zone is about 13 to 15KJ/cm for 10mm SWS41A steel plates, resulting from consideration upon both joint efficiency of above-100% and recovery of impact strength and strain. Meanwhile, the optimal heat input zone resulting from tension-tension fatigue limit above the base metal's of SWS41A plates is 16 to 19KJ/cm. Reliability of all the empirical equations reveals 95% confidence level. 6. The microstructure of the underwater welds of SES41A welded in such a zone has no weld defects such as hydrogen brittleness with supreme high hardness, since the HAZ-bond boundary area adjacent to both surface and base metal has only Hv400 max with the microstructure of fine martensite, bainite, pearlite and small amount of ferrite.

  • PDF