• Title/Summary/Keyword: Coal dust

Search Result 141, Processing Time 0.035 seconds

Effect of Coagulants on the Behavior of Ultra Fine Dust in a Coal Firing Boiler (석탄 화력 보일러에서의 응집제 이용에 따른 초미세먼지 거동)

  • Ryu, Hwanwoo;Song, Byungho
    • Applied Chemistry for Engineering
    • /
    • v.31 no.1
    • /
    • pp.84-89
    • /
    • 2020
  • Particulate matters of PM2.5, particularly focusing on 0.1~1 ㎛ decrease the efficiency of dust-collector due to the brownian-motion. This study is to verify the effect of coagulant on the particle size distributions of potassium and PM2.5. The activated coagulant was spayed to the coal fired fluidized bed combustion boiler by the weight ratio of 1,200 : 1 = coal : coagulant, and the size distributions of captured particles at both the cyclone (FP) and electrostatic precipitator (EP) were measured. As the result of XRP analysis, the potassium content of FP increased to 13.33% (averagely from 1.65% to 1.87%) and, in EP at 17.68% (averagely from 1.65% to 2.03%). And it was confirmed by the particle size distribution analyzer and SEM image analysis that the distribution rates of PM2.5 decreased at 89.53% on average in FP, and at 88.57% in EP. The total dust concentration (mg/㎥) confirmed by tele-monitering system (TMS) decreased during the primary test from 2.6 to 1.7~1.9 and also the secondary test from 2.9 to 1.7~1.9.

Comparision of Chest Radiographs and Pulmonary Function in Coal Workers' Pneumoconiosis and Welders' Lung (탄광부 진폐증과 용접공 폐증에 있어 흉부-X선 소견과 폐기능의 비교)

  • Park, Dong-Youl;Hwang, Joo-Ho;Kang, Byung-Son;Chung, Chan-Su;Kim, Wha-Jo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.713-722
    • /
    • 1995
  • Background: Chest X-ray of coal workers' pneumoconiosis and shipyard welders' lung show similar and regular opacities mostly, it is very difficult that we distinguish the former from the latter by only chest X-ray. so we performed this study to understand the progression of the disease and to provide the disease by considering pulmonary function and other factors in proportion to the profusion of small regular opacities of chest X-ray in both groups. Method: 430 coal workers' pneumoconiosis were compared with 311 shipyard welders' lung by the number, the age, the duration of dust exposure, %vital capacity(%VC), %FEV1.0, the type of ventilatory impairment, the combined pulmonary disease according to the profusion of small regular opacities on the chest radiographs, which were classified into category 0/1, category 1, and category 2. Result: 1) the percent of category 2 in coal workers' pneumoconiosis was 54.4%. the percent of category 1, and category 2 in welders' lung were 60.0%, 7.4%. the progression to the category 2 was higher in coal workers' pneumoconiosis than in welders' lung 2) The mean age was higher in coal workers' pneumoconiosis than in welders' lung, significantly increased in proportion to the progresion of profusion of small regular opacities in both groups 3) There was no difference in the duration of dust exposure by category 1/0, but the duration of dust exposure by category 1, 2 in coal workers' pneumoconiosis more significantly increased than in welders' lung. the duration in the proportion of category 2 to category 0/1, 1 significantly increased in the proportion to small regular opacities in coal workers' pneumoconiosis. but there was no significant difference in the proportion to small regular opacities in duration of dust exposure in welders' lung. 4) There was no significant difference of mean values of %VC(%vital capacity)in both groups except for category 1. the mean values of %VC had no relationship between the progression of small regular opacities in both groups. 5) The mean values of %FEV1.0 decreased more significantly in coal workers' pneumoconiosis than in welders' lung except for category 0/1. and decreased significantly in proportion to the profusion of small regular opacities in coal workers' pneumoconiosis. there was significant difference of %FEV1.0 in the proportion of category 2 to category 011 in welders' lung. 6) there were no significant difference of %FEV1.0, %VC in smoker and nonsmoker in both groups. 7) With regard to the type of ventilation in both groups in coal workers' pneumoconiosis 21.4 percent of patients belonged to the restrictive type, 11.6 percent to the obstructive type, 5.6 percent to the combined type, but in welders' lung 21.8 percent to the restrictive type, 2.9 percent to the obstructive type, 1.9 percent to the combined type. 8. in the pulmonary disease, the incidence of the pulmonary tuberculosis was the most in both groups, was more in coal workers' pneumoconiosis than welders' lung Conclusion: If we compare coal workers' pneumoconiosis with electric arc welders'lung by considering pulmonary function and other factors in proportion to the profusion of chest X-ray, I think that we will have the better result in understanding the progression of the disease and provision of the disease in both groups.

  • PDF

A Study of Heavy Metal Pollutants in the Respirable Dust in Seoul Area (호흡성분진중의 중금속 오염도에 관한 조사연구)

  • Lim, Young-Wook;Chung, Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.68-78
    • /
    • 1989
  • The heavy metal of suspended particulates with human health has long been studied in environmental interest concerned. This study was intended to identify harmful heavy metals of the ambient air borne dusts which were related with the respirable sizes in the aerodynamics. Two sampling sites were selected comparatively; one was in the Shinchon area, which is the commercial district with heavy traffic and the other site was in the Bulgwang area which is residential area. The supended particulates were sampled by high volume air sample with 6 cascade impactor stages. The heavy metals in terms of As, Cd, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Se, V and Zn were determined by stomic absorption spectrometry or inductively coupled plasma emission spectrometry. The samples weretaken bimothly for seven consecutive days from May 1987 to March 1988. The annual average concentration of the respirable suspended dust of which diameter is less than 10$\mum$ was 152.59 $\mug/m^3$ of the Shinchon air samples; the respirable dust was equivalent to approximately 85% of the total suspended particulates. The annual average concentration of the respirable suspended dust of the Bulgwang air samples was 112.56 $\mug/m^3$; that was approximately 86% of the total suspended particulates. The concentration of heavy metals was investigated in relation to the particle size. The concentration of Cr, Fe, Mn and V were tended to be much more in the coarse particles than in the fine particles. Cd and Pb in the fine particles were more than in the coarse particles. In the partial correlation coefficients; in the Shinchon area, high correlations among Fe, Se and Mn were determined; it is assumed that those sources would be originated from coal, gasolineand diesel. In Bulgwang area, would be high correlation among Fe, Se, Hg and Mn considered to be originated from coal, Bunker-C and heavy oil as well. From the above results, the hazardous heavy merals in air should be measured and controlled in originally their sources.

  • PDF

Elemental Composition of PM2.5 Particulate with a 3-Stage DRUM Sampler during Spring and Summer Seasons in Urban Area of Gwangju, Korea (3-Stage DRUM 샘플러를 이용한 광주 도심지역의 봄철과 여름철 PM2.5 원소적 조성 비교)

  • Ryu S.Y.;Kim Y.J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.6
    • /
    • pp.699-708
    • /
    • 2005
  • To characterize the elemental composition of fine particles in urban area, $PM_{2.5}$ was collected by a 3-stage DRUM impactor at Gwangju during spring and summer. Time and size resolved concentrations for 19 trace elements were obtained by synchrotron X-Ray fluorescence analysis. Trace elements in summer were distributed in smaller size range compared to those in spring. Almost trace element concentrations in fine particles were highly increased during the Asian dust. In spring, soil elements such as Si, K, Ca, Ti and Fe had low enrichment factors indicating the dominant influence of soil dust. However, all elements had high enrichment factors in summer implying that these elements could be emitted from the anthropogenic sources. Factor analysis was conducted with the elemental composition data in order to identify anthropogenic sources of aerosols in urban area during spring and summer. Fine particles in spring have several sources such as soil dust originating from China continental region, coal and oil combustion, biomass burning, sea salt, ferrous and nonferrous metal sources. On the other hand, fine particles in summer were influenced by road dust, gasoline vehicle as well as coal and oil combustion, sea salt, ferrous and nonferrous metal sources.

Quantitative Analysis of Quartz, Mica, and Feldspar in Respirable Coalmine Dust in Taebaek Area by Fourier Transform Infrared Spectrophotometry (간섭식 적외선 분광기에 의한 태백지역 석탄광의 호흡성 분진 중 석영, 운모 및 장석의 정량분석)

  • Choi, Ho-Chun;Cheon, Yong-Hee;Kim, Hae-Jeong;Lee, Jeong-Joo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.2 s.24
    • /
    • pp.271-283
    • /
    • 1988
  • A Fourier transform infrared spectrophotometric method was described for the determination of quartz, mica(sericite) and feldspar(potassium feldspar) in respirable dust in Taebaek area. The results were as follows; 1) The concentration of minerals were determined from the intensity of absorption peak of quartz at $799cm^{-1}$, sericite at $539cm^{-1}$, and potassium feldspar at $648cm^{-1}$ respectively. 2) The precision(C. V. %) for the quartz determination was $7.70{\pm}2.68%$ from 10 to $200{\mu}g$ of quartz. 3) The precision for the sericite determination was $16.34{\pm}6.82%$ from 30 to $500{\mu}g$ of serictite. 4) The precision for the potassium feldspar determination was $5.28{\pm}1.74%$ from 30 to $500{\mu}g$ of potassium feldspar. 5) The concentration of respirable dust in Taebaek area was $4.90{\pm}3.29mg/m^3$ (0.4-93.7%), percent quartz was $1.80{\pm}4.14%$ (0.01-20.56%), percent sericite was $11.37{\pm}6.43%$ (0.00-29.69%), percent potassium feldspar was 8.15% (n=7, 3.41-19.70%). 6) The difference of respirable coal dust, quartz, and sericite concentrations in drilling, coal cutting, hauling and seperating was significant respectively (p<0.05).

  • PDF

Evaluation of Environmental Benefit and Cost for Management of Air Quality - [Based on Fine Dust Pollution on Donghae Harbor] (공기질 관리에 관한 환경 비용편익 연구[동해항만 주변 미세먼지오염을 기준])

  • Kim, Eun-Joo;Lee, Choon-Gil;Kim, Ji-Hyun;Park, Young-Koo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.561-569
    • /
    • 2012
  • Study attempts to evaluate the environmental cost and benefit for management of particulate matters of Donghae harbor in Gangwondo. The level of fine dust suspended in the vicinity of the harbor was quite high, exceeding the national standard ($100{\mu}g/m^3$) depending on the places. The test field harbor deals with lots of limestone and coal, so that fine particulates could be generated while loading it and unloading. It was estimated that the direct handling of cargos might produce 12 tons of PM10(Particulate Matters of $10{\mu}m$) a year. In addition, heavy vehicles for transportation of various cargos including raw materials emit huge amount of diesel soots and cause to redispersion of road dust. The local government spends more than 2 billion won every year, and it contributes to reduce the atmospheric dust. According to the prediction of cost to benefit, it will present the effectiveness in 720 % maximum and at least 240 %.

Electrostatic Precipitation Characteristics of Coal Combustion Boiler (석탄연소 보일러용 분진의 전기집진특성)

  • Lee, Tae-Sik;Bun, Cha-Seok;Kim, Gyeong-Seok;Nam, Chang-U;Lee, Gyu-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.6
    • /
    • pp.475-482
    • /
    • 1999
  • The electrostatic precipitation characteristics of two kinds of fly ashes, one derived from a fluidized bed combustor(FBC), the other from a pulverized coal(PC) fired furnace, have been studied on a pilot plant. Experiments have been carried out to enhance the collection efficiency while changing the operating conditions for two kinds of coal ashes, respectively. It has been shown that collection efficiency is affected by many factors such as shape of the ashes, dust contents, humidity, and temperature, etc. Experimantal results showed that collection efficiency of the FBC ashes was higher than that of the PC fly ash in spite of the small size of the FBC ashes. The experimetal results have been applied to the collection efficiency equations to show that the modified Deutsch equation was well agreed with experiment results if modification parameter k was set to 0.6 for the fluidized bed fly ashes and to 0.43 for the pulverized coal fly ashes.

  • PDF

A Study on Emission Characteristics of Mercury from Coal Combustion at a Lab-scale Furnace (실험용 연소로에서 석탄 연소 시 발생하는 수은 배출특성 연구)

  • Park, Kyu-Shik;Lee, Ju-Hyoung;Kim, Jeong-Hun;Lee, Sang-Hyeob;Seo, Yong-Chil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.238-248
    • /
    • 2008
  • This study investigated mercury emission at various combustion conditions and analyzed mercury species in flue gas from coal combustion at a laboratory scale furnace in coal. The results of this study can be used to predict and to assess mercury emission at coal boilers and power plants. The coal used in the plants generally contains about $0.02{\sim}0.28\;mg$ of mercury per kg. Bituminous and anthracite coal used for the experiment contained 0.049 and 0.297 mg/kg of mercury, respectively. Mercury emissions during coal combustion at temperatures range of $600^{\circ}C$ to $1,400^{\circ}C$ was measured and analysed using Ontario Hydro method; the speciation changes were also observed in mercury emissions. The results showed higher fraction of elemental mercury than that of oxidised mercury at most temperatures tested in this experiment. The fraction of elemental mercury was lower in combustion of anthracite coal than in bituminous combustion. As expected, equilibrium calculations and real power plants data showed good similarity. The distribution of particle size in flue gas had the higher peak in size above $2.5\;{\mu}m$. However the peak of mercury enrichment in dust was at $0.3\;{\mu}m$, which could be easily emitted into atmosphere without filtration in combustion system. When the CEA(Chemical equilibrium and Application) code was used for combustion equilibrium calculation, Cl was found to be the important component effecting mercury oxidation, especially at the lower temperatures under $900^{\circ}C$.

Local Exhaust Ventilation Characteristics of Coal Dust in Coal Preparation Plant of a Coal Mine (석탄광산 선탄장에서 비산분진의 국소배기 특성)

  • Lee, Seung-Chul;Jo, Woo-Hyun;Park, Young-Rok;Ok, Yun-Yong;Kim, Tae-Hyuk
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.259-262
    • /
    • 2009
  • 본 연구에서는 석탄광산 선탄장설비와 국소배기시스템의 일부를 모형화하여 포집특성과 유동특성실험을 수행하였으며 동일조건에서 수치해석을 수행하여 그 결과를 비교 검토하였다. case 5가 46.35%의 가장 높은 포집효율을 보였으며 실험의 3가지 변수 중 고무 커튼의 사용유무가 국소배기시스템의 포집효율에 가장 큰 영향을 미치는 것으로 판단된다. 또한 case 1, 5, 6에 대해 포집된 입자크기 확인 결과, 포집성능이 우수한 case 5가 입경 $20{\mu}m$ 초과 입자들이 약 55%로 가장 많이 포집된 것을 알 수 있었다. 따라서 제어거리는 0.5m 이상이 적절한 것으로 판단된다.

  • PDF

Evaluation of Internal through Analysis of Airflow and Ventilation of Coal Storage Shed (옥내저탄장 기류 흐름 및 환기량 분석을 통한 내부 유동 평가)

  • Jo, Hyun-Joung;Lee, Jin-Hong
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.5
    • /
    • pp.334-342
    • /
    • 2022
  • The stringent air environment conservation act forced to build an indoor dome for coal storage. However, it causes some problems due to accumulation of fly ash and harmful substances inside. To solve this problem, this study analyzed the pattern of internal airflow and the amount of ventilation for an indoor coal yard. Overall, the airflow inside the indoor coal yard tended to move to the southwest facing the mountain. In addition, sea-breeze was blowing from the northern louver window facing the sea, where airflow was flowing in. The total flow rate flowing into the indoor coal yard was 918,691 m3/h, and the number of natural ventilation per hour was 0.6 times. Therefore, it is proposed to install a forced ventilation device at the location where internal air flow is concentrated.