• Title/Summary/Keyword: Coal dust

Search Result 141, Processing Time 0.028 seconds

Suspended Particulate Concentration at the Drilling Site of Underground Coal Mines in Taebaek Area (태백지역 석탄광업 굴진부서의 부유분진 농도)

  • 윤영노;김영식;이영신
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.1
    • /
    • pp.32-38
    • /
    • 1991
  • Airborne suspended particulate concentration in drilling sites of underground coal mines in Taebaek area was evaluated. And respirable coal dust exposure level was evaluated. Airborne suspended particulate mass include total suspended particle(TSP) and thoracic particle(TPM). TSP (by open-face filter holder) and TPM(by elutriator) concentration were determined by low volume air samplers. Personal air samplers were attached to the coal workers including drillers, coal cutters, and their assistants. Normality and log-normality of TSP, TPM, and respirable dust(RPM) concentration were tested by Kolmogorov-Smirnov one-sample test. Differences of means of TSP, TPM, and RPM concentration were tested by paired t-test. Relation between TSP, TPM, and RPM with pairs were tested by regression test and Pearson's correlation.

  • PDF

Dust Removal Efficiency and Operation Characteristics of Metal Filters for Coal Gasification Fines and Standard Dust Sample (금속필터를 사용한 석탄가스화 분진 및 표준 분진의 집진 효율과 운전특성)

  • Yun, Yongseung;Chung, Seok Woo;Lee, Seung Jong
    • Korean Chemical Engineering Research
    • /
    • v.57 no.4
    • /
    • pp.461-468
    • /
    • 2019
  • Demand for improving dust removal efficiency in coal power plants and the dust removal requirement to the level of capturing fine particulate matter and ultrafine particles have been increasing. While bag filter and electrostatic precipitator (ESP) are typically used for dust removal in the processes operating at atmospheric pressure, metal filters or ceramic filters are employed for dust which is produced at high temperature/pressure system as in coal gasification. For dust removal at the high temperature/pressure conditions, two metal filters of five compressed/sintered layers were manufactured and applied to analyze the dust removal characteristics. Manufactured metal filters exhibited more than 99% dust removal efficiency on coal gasification fine particulates in mass basis. To evaluate the fine particulate removal efficiency of less than $2.5{\mu}m$, JIS standard fine sample was used and confirmed the removal efficiencies of 97% and 70~82% on the fine particulates of $1{\sim}2.5{\mu}m$ size range. For the size range of less than $1{\mu}m$, dust removal efficiency of manufactured metal filters significantly degraded with smaller particle size. Improving methods are proposed to overcome the limitations in applying to fine dust of less than $1{\mu}m$.

Occupational exposure to dust and respirable quartz in coal briquettes ash handling worker (연탄재 처리 환경미화원의 분진 및 호흡성 석영 노출)

  • Kim, Boowook
    • Particle and aerosol research
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • The purpose of this study is to assess respirable crystalline silica (RCS) exposure levels in workers who collect and dispose used coal briquette ash (CBA) in sanitation companies that are subcontracted by one medium-sized local government on the collection of municipal household waste (MHW), and to analyze the quartz content in CBA. When the CBA powder that undergone specialized pretreatment in several steps were subjected to mineral identification and quantitative analysis using X-ray diffraction (XRD), it was found that quartz represented 18%, and in addition, mullite, and plagioclase were included. For two CBA collectors, samples were collected by the personal sampling evaluation method. After respirable dust was collected in accordance with the National Institute for Occupational Safety and Health 7500 method, the concentration of quartz was analyzed using XRD. Meanwhile, a portable real-time dust monitor (Sidepak AM520, TSI Inc., USA) was also used to observe the dust exposure level for each time zone and job task. The RCS exposure level of one worker was as high as 0.024 mg/㎥, which was the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Values (TLV) level. The other worker also exhibited a concentration of 0.013 mg/㎥, which was more than half of TLV. The Sidepak results revealed that the work of collecting CBA and loading it onto a vehicle was hardly exposed to the dust of a significant level. It was found, however, that the work of transferring the collected CBA to a container through a conveyor belt was exposed to a very high average respirable dust concentration of 2.238 mg/㎥. The results of this study confirmed that quartz, which is crystalline silica and a carcinogen, is contained in CBA, one of municipal household waste (MHW), in high concentration. It was also confirmed that workers are exposed to high RCS concentrations while transferring collected CBA into a container. Although each local government in South Korea handles CBA in different ways, it is imperative to investigate the CBA exposure level of sanitation workers and improve their working conditions.

Effect of EAF dust on the formation of ultra lightweight aggregates by using bottom ash and dredged soil from coal power plant (인공경량골재의 EAF dust 첨가에 따른 초경량화에 관한 연구)

  • Choi, Yun-Jae;Kim, Yoo-Taek
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.21 no.3
    • /
    • pp.129-135
    • /
    • 2011
  • EAF dust from steel industry used as primary materials for the production of lightweight aggregates. Fe compounds in EAF dust plays an important role in the bloating reaction. This study was conducted to evaluate the feasibility of using bottom ash and dredged soil from coal power plant and EAF dust. The effect of different raw material compositions and sintering temperatures on the lightweight aggregate properties were evaluated. The characteristic of thermal bloating of bottom ash and dredged soil were mainly influenced by ferrous materials. The specific gravity of aggregate was decreased with the addition of EAF dust and kerosene was reduced sintering temperature on the bloating formation. Lightweight aggregate containing 10% EAF dust having apparent density under 1.0 g/$cm^3$ were produced at $1150{\sim}1200^{\circ}C$.

Density Distributions of Metallic Compounds in Particulate Matters (粒子狀 物質中 金屬成分의 密度分布)

  • 허문영;김형춘;손동헌
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.2
    • /
    • pp.9-18
    • /
    • 1986
  • For identification and apportionment of sources emitting particulate matters in environment, the multi-elemental characterization of size-density fractionated particulate matters was carried out. Eight types of samples were tested; soil, flyash released from burning of bunker-Coil, diesel oil, coal, and soft coal, urban road-way dust, urban dust fall, and airborne particulate matter. The fractions of particulate matters obtained by heavy liquid separation methos with a series of dichloromethane-bromoform were then analyzed using atomic absorption spectrophotometry for Ni, Cr, Cu, An, Fe, Al, and Mg. Each sample showed a different concentration profile as a function of density, and a number of useful conclusions concerning characterization of elemental distribution were obtained. From the density distributions of elements in soil, the maximum value was found for all elements in the density range of 2.2 $\sim 2.9g.cm^{-3}$, including the density of $SiO_2$. However, the distribution of metallic compounds with the density lower than $2.2g.cm^{-3}$ was prevalent in urban roadway dust, urban dust fall, and airborne particulate matter. And the density distribution curves of these urban dusts also have the higher distribution at the density of 2.2 - 2.9g.cm^{-3}$, including the density of wind-blown silica. This tendency generally was prevalent in the natural source elements, such as Al, Fe, Mn, and Mg. The maximum values were found in the density ranges of 1.3 $\sim 2.2g.cm^{-3}$ from the density distribution of elements in oil fired flyash. These distributions of anthropogenic source elements, such as Zn, Ni, Cu, and Cr were higher predominately than those of natural source elements. And the higher distribution was found in the density range of $2.2 \sim 2.9g.cm^{-3}$ from the density distribution of elements in coal and soft-coal fired flyash. These distributions showed similar patterns to soil. But anthropogenic source elements somewhat predominated at the density ranges of $1.3 \sim 2.2g.cm{-3} and 2.9g.cm^{-3}$ to soil. Therefore the higher distribution of anthropogenic source elements in the density ranges of $1.3 \sim 2.2g.cm^{-3} and 2.9g.cm^{-3}$ was considered as anthropogenic origin.

  • PDF

Effect of Adding Gypsum and Coal Fly Ash on Composting Process of Pig Manure (돈분 퇴비화 공정에서 석고 및 석탄회의 첨가효과)

  • 유현철;김정섭;곽명화;이히인;박승조
    • Resources Recycling
    • /
    • v.11 no.1
    • /
    • pp.32-36
    • /
    • 2002
  • This study was conducted to compost the mixture of Pig manure, gypsum and fly ash. Initial moisture contents of sample A (Pig manure : saw dust = 6 : 4) and C (Pig manure : saw dust : gypsum : coal fly ash= 6 : 2 : 1 : 1) in the reactor were 64 and 50%. Also temperature and pH of samples in the reactor was nearly the same. Total Organic Carbon (TOC) concentration of sample A and C were about 5500, 2900 mg/kg respectively. This sample was needed a lot of time to mature as viewing cation exchange capacity (CEC) after experiment was over. However added with gypsum and coal fly ash in Process of Pig manure composting Process was suggested that gypsum and coal fly ash have a roles of additive agent.

A Study on Methods for Developing by Nurturing Clean Thermal Power Generation Technology (청정화력발전 기술 육성 방안 연구)

  • Kim, Yeong-Mi;Lee, Won-Hak
    • Journal of Climate Change Research
    • /
    • v.9 no.2
    • /
    • pp.197-207
    • /
    • 2018
  • The Korean government views coal-fired power plants as the key cause of the fine dust generation, and is developing an energy policy to replace and demolish old coal-fired power plants. According to the Eighth Power Supply Base Plan (2017-2031), the maximum power capacity in 2030 is expected to be 100.5GW, which is 17.9% higher than the current level (85.2GW). The plan aims to reduce the facility size and power generation ratio from nuclear and coal resources to even lower levels than today, and to rapidly expand power generation from new and renewable energy. Despite that, the proportion of coal power generation is still much higher than other resources, and it is expected that the reliance on goal will maintain for next several decades. Under such circumstances, the development, supply, and expansion of clean coal technology (CCT) that is eco-friendly and highly efficient, is crucial to minimize the emission of pollutants such as carbon dioxide and fine dust, as well as maximize the energy efficiency. The Korean government designated the Yong-Dong Thermoelectric Power Plant in Gangneung to develop clean coal power generation, and executed related projects for three years. The current study aims to suggest a plan to develop parts, technologies, testing, evaluation, certification, and commercialization efforts for coal-fired power generation, In addition, the study proposes a strategy to vitalize local economy and connect the development with creation of more jobs.

Relationship between the Measurement Values of the Digital Dust Indicator and Personal Dust Sampler (Digital 분진계와 개인용 분진 포집기의 측정값의 관계)

  • Yoon, Young-No;Lee, Jeong-Joo;Chung, Ho-Keun;Choi, Ho-Chun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.20 no.2 s.22
    • /
    • pp.255-260
    • /
    • 1987
  • The digital dust indicator (Sibata P-5), one of the direct·reading instruments was evaluated for the respirable dust in the underground coal mine environments. As a reference, respirable dust was determined using three cyclones and/or impactors. All the tests were performed on aerosol in twenty underground coal mines. The coefficients of mass-relative concentration were $0.067{\pm}0.054$ (Mean$\pm$Standard deviation) (range: 0.006-0.172). The relationship between relative concentration and temperature was not significant statistically. Also, the relationship of relative concentration and relative humidity was not significant. Mass concentration and relative concentration were $5.31{\pm}5.22mg/m^3$ and $162{\pm}163$ CPM ($Mean{\pm}Standard$ deviation) respectively. The range of mass concentration was $1.22-22.69mg/m^3$; relative concentration 16-628 CPM. The relationship of mass concentration and relative concentration was not significant in these ranges.

  • PDF

Assessment of Coal Dust Exposure in Korean Mine in 1980's (1980년대 초 한국 석탄 탄광의 자료를 이용한 로그-정규분포의 적용)

  • Lee, Kiyoung;Sherwood, R.J.
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.4
    • /
    • pp.345-352
    • /
    • 2012
  • 1980년대 초 Sherwood교수가 한국에 와 있으면 당시 탄광의 호흡성먼지의 농도를 측정한 자료를 활용하여 로그-정규분포에 대한 분석을 한 자료이다. 탄광의 건조상태에서 농도는 물을 뿌리면서 하는 작업에 비해 매우 높은 수준을 보인다. 건조한 탄광에서 기하평균농도는 $26.1mg/m^{3}$이었고 물을 뿌린 탄광에서는 $4.1mg/m^{3}$이었다. 이는 매우 높은 수준이었음을 알 수 있다. 각 탄갱에서의 농도는 로그정규분포를 하였고 석탄을 접하는 탄갱에서의 농도는 $1.65mg/m^{3}$에서 $35mg/m^{3}$까지 다양하였다. 호흡성분진의 농도는 석탄을 접하는 탄갱에서 암석을 접하는 탄갱보다 높았는데 이는 분진의 원인이 석탄 때문이었다.

The System of Plasma Ignition for Coal-Dust and Water-Coal Fuels Ignition

  • Park, Hyun-Seo;I. M. Zasypkin;A. N. Timoshevskii
    • Resources Recycling
    • /
    • v.12 no.2
    • /
    • pp.54-61
    • /
    • 2003
  • In this paper a system of plasma ignition(SPI) which is applied for the ignition and stabilization of coal-dust fuel burning for decreasing fuel black oil consumption is described. The advantages of SPI are demonstrated, and the positive results of SPI which is operated at the thermal-clamping boilers installed in production and heating plants are described. The similar system was tested in demonstration and industrial installations to confirm the results. The improvement of economical, operating and ecological performances of the boiler are shown.