• Title/Summary/Keyword: Coal Power Plant

Search Result 531, Processing Time 0.023 seconds

Characteristic studies of coal power plants ash sample and monitoring of PM 2.5

  • Thriveni., T;Ramakrishna., CH;Nam, Seong Young;kim, Chunsik;Ahn, Ji Whan
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.45-56
    • /
    • 2017
  • Coal power plants produce electricity for the nation's power grid, but they also produce more hazardous air emissions than any other industrial pollution sources. The quantity is staggering, over 386,000 tons of 84 separate hazardous air pollutants spew from over 400 plants in 46 states. In South Korea also, annual coal ash generation from coal-fired power plants were about 6 million tons in 2015. Pollutants containing particulate matter 10, 2.5 (PM10, PM2.5), heavy metals and dioxins from coal-fired power plant. The emissions threaten the health of people who live near these power plants, as well as those who live hundreds of miles away. These pollutants that have long-term impacts on the environment because they accumulate in soil, water and animals. The present study is to investigate the physical and chemical characteristics of coal-fired power plant fly ash and bottom ash contains particulate matter, whose particulate sizes are lower than $PM_{10}$ and $PM_{2.5}$ and heavy metals. There are wide commercial technologies were available for monitoring the PM 2.5 and ultra-fine particles, among those carbonation technology is a good tool for stabilizing the alkaline waste materials. We collected the coal ash samples from different coal power plants and the chemical composition of coal fly ash was characterized by XRF. In the present laboratory research approach reveals that potential application of carbonation technology for particulate matter $PM_{10}$, $PM_{2.5}$ and stabilization of heavy metals. The significance of this emerging carbonation technology was improving the chemical and physical properties of fly ash and bottom ash samples can facilitate wide re use in construction applications.

Process Modeling of the Coal-firing Power Plant as a Testbed for the Improvement of the System and Equipment (화력발전 시스템 및 설비 개선 실증을 위한 열물질정산 공정모델 개발)

  • Ahn, Hyungjun;Choi, Seukcheun;Lee, Youngjae;Kim, Beom Soo
    • Journal of the Korean Society of Combustion
    • /
    • v.23 no.1
    • /
    • pp.44-54
    • /
    • 2018
  • Heat and mass balance process modeling has been conducted for a coal-firing power plant to be used as a testbed facility for development of various plant systems and equipment. As the material and design of the boiler tube bundle and fuel conversion to the biomass have become major concerns, the process modeling is required to incorporate those features in its calculation. The simulation cases for two different generation load show the satisfying results compared to the operational data from the actual system. Based on the established process conditions, the hypothetical case using wood pellet has also been simulated. Additional calculations for the tube bundle has been conducted regarding the changes in the tube material and design.

An Experimental Study on the Separating Effect of Pulverized Coal at Coal Nozzle with Coal Separator (석탄 노즐내 미분탄 분리장치의 입자 분리 효과에 관한 실험적 연구)

  • Kim, Hyuk-Je;Song, Si-Hong;Lee, Gun-Myung;Kim, Sang-Hyeun;Lee, Ik-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.764-769
    • /
    • 2001
  • Recently, according to increase in the requirement of electric power, a thermoelectric power plant equipped with pulverized coal combustion system is highly valued, because coal has abundant deposits and a low price compared with others. For efficient use of coal fuel, most of plant makers are studying to improve combustion performance and flame stability, and reduce pollutant emission. One of these studies is how to control the profile of particle injection and velocity dependant on coal nozzle. Basically, a mixed flow of gas and particle in coal nozzle is required to have appropriate injection and concentration distribution at exit to achieve flame stability and low pollutant, but it is very difficult to obtain that without help of a coal separating device within nozzle. In this study, each distribution of air and coal flow rate is measured for the coal nozzle with coal separator developed by us. The coal concentration at exit is various according to inlet swirl values and positions of coal separator. Also pressure drop is measured for various operating conditions of this nozzle. From these results, we can find the separation characteristic of new developed coal separator, and select proper operation range of coal nozzle. When this coal nozzle is applied to actual plant, these investigations will be very useful to confirm the shape of coal separator to have efficient particle injection.

  • PDF

The Effect of Multi-Coal Combustion on the Generation of Slagging in a Bituminous Coal-fired Power Plant Boiler (연탄 화력발전소 보일러에서 다탄종 연소가 슬래깅 발생에 미치는 영향)

  • Park, Jihoon;Yoo, Hoseon
    • Plant Journal
    • /
    • v.18 no.1
    • /
    • pp.55-61
    • /
    • 2022
  • In this study, I analyzed the effect of slagging caused by blending bituminous coal and subbituminous coal while maintaining the generator output, combustion conditions, and ventilation conditions for 870MW thermal power plant designed with bituminous coal. Accordingly I proposed an acceptable method of blending coal method. the blending ratio of sub-bituminous coal was adjusted to 10%, 20%, 40%, 60%, 80%, etc. to confirm ultimate analysis, proximate analysis, ash fusion temperature change, slagging indices, etc. Proper blending coal conditions are blending with sub-bituminous coal at 40% or less, ratio of base component to acid component(B/A) is 0.4 or less or 1 or more, total alkali(TA) is 3.5 or less, fusion slagging index(Rfs) is 1,345℃ or more, and ash content is 13% or less in ultimate analysis, the ash content in proximate analysis is 15% or less, and the initial deformation temperature(IDT) should be at least 1,200℃ or more

  • PDF

Protection Performance Simulation of Coal Tar-Coated Pipes Buried in a Domestic Nuclear Power Plant Using Cathodic Protection and FEM Method (국내원전에 매설된 콜타르 코팅 배관의 음극방식과 FEM법을 이용한 방식성능 시뮬레이션)

  • Chang, H.Y.;Kim, K.T.;Lim, B.T.;Kim, K.S.;Kim, J.W.;Park, H.B.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.115-127
    • /
    • 2017
  • Coal tar-coated pipes buried in a domestic nuclear power plant have operated under the cathodic protection. This work conducted the simulation of the coating performance of these pipes using a FEM method. The pipes, being ductile cast iron have been suffered under considerably high cathodic protection condition beyond the appropriate condition. However, cathodic potential measured at the site revealed non-protected status. Converting from 3D CAD data of the power plant to appropriate type for a FEM simulation was conducted and cathodic potential under the applied voltage and current was calculated using primary and secondary current distribution and physical conditions. FEM simulation for coal tar-coated pipe without defects revealed over-protection condition if the pipes were well-coated. However, the simulation for coal tar-coated pipes with many defects predict that the coated pipes may be severely degraded. Therefore, for high risk pipes, direct examination and repair or renewal of pipes are strongly recommended.

Reduction of unburned carbon derived from coal-fired power plant by changing operating conditions (운전조건병경에 의한 미분탄화력의 미연분 저감)

  • Park, Ho-Young;Kim, Young-Ju;Yu, Guen-Sil;Kim, Chun-Kun;Kim, Dong-Hun
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.299-303
    • /
    • 2006
  • From the analysis of fly ash, which contains unburned carbon, collected from the coal-fired Yong Hung power station, most particles are turned out to be hollow cenosphere and agglomerated soot particles. The sooting potential from six coals used in the plant were investigated with CPD model. The results show that the higher potential presented to Peabody, Arthur, Shenhua coals rather than other coals. It is necessary to measure the coal flow rates at each coal feeding pipe for four burner levels since they affect the extent of mixing of soot with oxidant, in turn, the oxidation rate of soot particles. The unbalance in coal flow rate was found in several coal pipes. We successfully reduced unburned carbon in ash by increasing the excess air and changing the SOFA yaw angle.

  • PDF

Co-combustion of RPF in the Coal Power plant (석탄보일러에서 각종 RDF혼소시 다이옥신 농도 조사)

  • Choi, Yeon-Seok;Choi, Hang-Seok;Kim, Seock-Joon;Yoon, Kyoon-Duk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.452-455
    • /
    • 2008
  • The co-combustion of coal and three kinds of RDFs(Refuse Plastic Fuel) mixture has been experimented in a commercially operating CFB coal boiler respectively and the pollutant emissions such as SOx, NOx, TSP and dioxine were measured at the stack. The mixing ratio with coal was 7.5% RPF, 7.5% RDF and 10% SDF respectively. During co-combustion, dioxine emission level was very low and SOx, NOx and TSP were decreased comparing the single coal combustion. Emitting dioxine concentration was proportioned to the chlorine content of RDF. These RPF, SDF and RDF could be determined to be a good alternative fuel of general coal.

  • PDF

Boiler Performance Characteristics Change by UC Contents Increase for Coal Fired Power Plant (석탄연소 화력발전소에서 미연탄소분 농도 증가가 보일러 성능에 미치는 영향에 관한 연구)

  • Kim, Taehyung;Park, Byungchul
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.99-102
    • /
    • 2015
  • To operate coal fired power plant efficiently is considered unburned carbon as important factor. But, unburned carbon contents change does not have an impact on Boiler performance simultaneously. we evaluated that unburned carbon contents change had an little influence on unburned carbon loss change for performance side at a real power plant.

  • PDF

Specification of Chemical Properties of Feed Coal and Bottom Ash Collected at a Coal-fired Power Plant

  • Ma, Chang-Jin;Kim, Jong-Ho;Kim, Ki-Hyun;Tohno, Susumu;Kasahara, Mikio
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.80-88
    • /
    • 2010
  • In order to offer a better understanding of air pollution of China as well as East Asia we attempted to characterize the chemical properties of the raw coal materials mined in China and their combusted bottom ashes generated from coal fired power plant. To this end, we measured the chemical characteristics of individual bottom ashes and feed coal fragments collected at a coal fired power generator which was operated with the raw coal dug at a coal mine in China. The chemical properties of these two sample types were determined by a synchrotron radiation X-ray fluorescence (SR-XRF) microprobe method. Through an application of such technique, it was possible to draw the 2D elemental maps in and/or on raw coal fragments and fired bottom ashes. The pulverized fine pieces of feed coal mainly consisted of mineral components such as Fe, Ca, Ti, Ca, and Si, while Fe was detected as overwhelming majority. The elemental mass of combusted bottom ash shows strong enrichment of many elements that exist naturally in coal. There were significant variations in chemical properties of ash-to-ash and fragment-to-fragment. Although we were not able to clearly distinguish As and Pb peaks because of the folding in their X-ray energies, these two elements can be used as tracers of coal fire origin.

A Study on the Design Concepts and Main Construction Processes of the Coal Shed at Thermal Power Plant (화력발전소 석탄저장고 설계개념과 시공과정 상의 주요 공정에 관한 연구)

  • Kim, Si-Hyun;Choi, Jang-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3619-3626
    • /
    • 2015
  • The coal shed at thermal power plant(T.P.P) is the biggest building on size among nuclear, coal and other power plant industry buildings. This the coal shed of indoor type is mass volume, the size of 6 soccer fields and 73 meter in height. Structural and functional elements take priority over aesthetic factors. The shed is built to make mighty space for structural safety and functional store by using the concrete, $75,000m^3$ on the total of central retaining wall and sub buttress, and the steel frame used by 11,744-ton P.E.B. system. The design requirement on its wall and frame, P.E.B. system's feature, and specific data of main process followed by construction are inquired. The aim of this study is to suggest the design requirement and guide for the indoor type of the coal shed.