• Title/Summary/Keyword: Coagulation system

Search Result 271, Processing Time 0.025 seconds

General Pharmacology of LB71350, a New HIV-1 Pretense Inhibitor

  • Kim, Hee-Jin;Oh, Jeng-In;Park, Hee-Dong;Kang, Ju-Seop;Ko, Hyun-Chul;Lee, Chang-Ho
    • Biomolecules & Therapeutics
    • /
    • v.7 no.3
    • /
    • pp.271-277
    • /
    • 1999
  • Safety evaluation of LB71350, a new HIV-1 protease inhibitor, was performed in mice, rats and dogs. For the general behavior of mice, LB71350 at an oral dose of 200 mg/kg did not show any significant effects on muscle tone and locomotor activity. In terms of central nervous system, at oral doses of 200 mg/kg and 1000 mg/kg, LB71350 inhibited acetic acid-induced pain response approximately 41% and 83% of control. respectively. At oral doses of 200 mg/kg and 500 mg/kg, it reduced the rectal body temperature in rats. Pentylenetetrazole-induced seizure in mice was slightly potentiated by oral administration of LB71350 at doses ranging from 200 mg/kg to 1000 mg/Ag. Single or five day treatment of LB71350 doubled the hexobarbital- induced sleeping time in mice at oral doses ranging from 50 mg/kg to 500 mg/kg. It did not cause any effects on gastric secretion and acidity in rat at oral doses of 200 mg/kg and 1000 mg/kg and also it did not change intestinal motility in mice up to 1000 mg/kg. Blood coagulation indices such as prothrombin time (PT), activated partial thromboplastin time (aPTT), and thrombin time (TT) in rats were not affected by the treatment of LB71350 up to 500 mg/kg. LB71350 caused no significant effects on the cardiac output, stroke volume, heart rate, and mean blood pressure when infused intravenously to the anesthetized rats and dogs. Taken together, LB71350 at high oral doses caused significant pharmacological effects on the central nervous system and the hexobarbital-induced sleeping time.

  • PDF

Inhibitory Effect of Hirudo on Neuroinflammation in LPS-stimulated Microglial Cells (Lipopolysccharides에 의해 활성화된 미세아교세포에서 수질(水蛭) 추출물의 NF-kB 억제를 통한 뇌신경염증 억제 효과)

  • Gunhyuk Park;Sungyu Yang;Byeong Cheol Moon;Sumin Noh;Hye-Sun Lim
    • Journal of Environmental Science International
    • /
    • v.32 no.4
    • /
    • pp.259-266
    • /
    • 2023
  • Today, environmental pollution has been found to be one of the causes of various diseases, including brain and nervous system diseases. In particular, neurodegenerative diseases have been found to be caused by hyperactivation of immune system cells such as microglia. Preventive and therapeutic measures are needed to suppress them. Hirudo is known as a traditional herbal medicine, based on its multiple biological activities such as anti-eczema and anti-coagulation. In the present study, the anti-neuroinflammatory potential of hirudo extract was investigated in lipopolysccharide (LPS)-stimulated BV2 microglial cells and in mice. Hirudo extract significantly inhibited LPS-stimulated nitric oxide (NO) production and cytokine (IL-1Ra, KC, MCP-5, and RANTES) expression in a dose-dependent manner without causing cytotoxicity. Pretreatment with hirudo extract suppressed LPS-induced NF-κB p65 nuclear translocation. Moreover, hirudo extract reduced LPS-stimulated microglial acitivation and improved memory impairments. The results demonstrated that hirudo extract exerts anti-neuroinflammation activities, partly through inhibition of the NF-κB signaling pathway. These findings suggest that hirudo extract might have therapeutic potential with respect to neuroinflammation and neurodegenerative diseases.

Evaluation of Streaming Current Detector (SCD) and Charge Analyzing System (CAS) for automation of coagulant dosage determination (낙동강 하류 원수의 응집제 주입 자동화를 위한 Streaming Current Detector (SCD)와 Charge Analyzing System (CAS)의 평가)

  • Kim, Sang-Goo;Son, Hee-Jong;Lee, Jeong-Kyu;Yeom, Hoon-Sik;Yoo, Pyung-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.4
    • /
    • pp.201-207
    • /
    • 2017
  • This study was conducted to investigate the characteristics of the stream current detector (SCD) and charge analyzing system (CAS), which are well known as the automatic coagulant dosage determination instruments. When the SCD system was used, the current charge value set at pH 9.3 could not be used as the coagulant dosage when the pH of the raw water decreased to 5.7, and the current charge value corresponding to pH 5.7 was required to be reset. In case of CAS system, polydadmac is stable as a cationic titrant when the pH of the raw water ranged 9.3 to 6.0. And it was effective to use polydadmac as a cationic titrant for high turbidity water. The current charge of polydadmac was almost constant between pH 5 and 11, however, the difference in charge of alum is six times in this pH range. Therefore, when the pH of the raw water was changed, it seems that the coagulant used in the actual water treatment plant was as a good cationic titrant.

Evaluation of System operated by Feed-and-discontinuous Bleed Mode using Tubular Type Ultrafiltration Membrane for Water Treatment (Feed-and-discontinuous Bleed 방식으로 운전되는 정수처리용 관상형 한외여과막 시스템의 평가)

  • Choi, Hyeok;Seo, Young-Woo;Kim, Hyung-Soo;Im, Jong-Seong;Hwang, Sun-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2187-2195
    • /
    • 2000
  • A water treatment system using membrane separation technology can provide stable effluent quality and its maintenance is relatively easy comparing to the conventional water treatment system. In addition, the membrane filtration system is very compact such that it can replace existing water treatment processes of coagulation/sedimentation/filtration by only one process. However, a major problem associated with membrane filtration is flux decline with operating time due to concentration polarization and fouling, so a systematic study on evaluation of long-term filtration performance is necessary. A membrane filtration system using tubular type ultrafiltration membranes with MWCO of 30.000 Da was constructed for this study and it had been operated in a feed-and-discontinuous bleed mode. Flux was stabilized after operation of 1.500 hours and maintaining above 25 LMH until 4.000 hours. Contaminants causing SS and turbidity were almost completely removed while the $UV_{260}$ and DOC removals were 55% and 49%, respectively. A simple mass balance equation was developed to predict maximum concentrations of SS, turbidity, $UV_{260}$ and DOC in a operation cycle. For SS and turbidity the measured max, concentrations in each cycle agree well with the predicted values while the measured max, concentrations of $UV_{260}$ and DOC were 59% and 37% of the predicted values, respectively.

  • PDF

Comparative performance evaluation of two UF pilot plants at the Alto da Boa Vista WTP (São Paulo, Brazil)

  • Oliveira, T.F.;Mierzwa, J.C.
    • Membrane and Water Treatment
    • /
    • v.2 no.3
    • /
    • pp.175-185
    • /
    • 2011
  • Ultrafiltration is an emerging technology for drinking water treatment because it produces better water quality as compared with conventional treatment systems. More recently, the combination of UF technology with other processes in order to improve its performance has been observed. These associations aim to maximize the contaminants removal and reduce membrane fouling. The operational performance of contaminants removal and water production of two UF pilot plants was compared. The first plant (Guarapiranga) was fed with raw water and the second plant (ABV) with pre-treated water by the coagulation, flocculation and sedimentation processes at Alto da Boa Vista WTP (Sao Paulo, Brazil). Both units operated continuously for approximately 2,500 hours, from September/2009 to January/2010. The results showed that the ABV UF pilot plant was able to operate at higher specific fluxes (6.2 $L.d^{-1}.m^{-2}.kPa^{-1}$ @ $25^{\circ}C$) than Guarapiranga (3.1 $L.d^{-1}.m^{-2}.kPa^{-1}$ @ $25^{\circ}C$). However, the number of chemical cleanings conducted in both pilot units during the considered operation period was the same (4 chemical cleanings for each plant), which shows that the pre-treatment reduced the membrane fouling. The water quality at ABV for all the variables analyzed was better, but the feed water quality was also better due to pretreatment. The rejection values for the different contaminants were higher at Guarapiranga mainly because of a pollution load reduction after pre-treatment at ABV. Even with the better performance of the ABV UF pilot plant, it is necessary to take into consideration the complexity of the complete treatment system, and also the costs involved in the construction and operation of a full-scale treatment unit.

Review for Clinical Studies of Oriental Medicine on the Treatment of Ovarian Hyperstimulation Syndrome (난소과자극증후군의 치료에 관한 한의 임상 연구 고찰)

  • Ku, Su-Jeong;Hwang, Deok-Sang;Lee, Jin-Moo;Lee, Chang-Hoon;Jang, Jun-Bock
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.33 no.3
    • /
    • pp.60-79
    • /
    • 2020
  • Objectives: This review plans to assess the efficacy and effectiveness of oriental medicine for the treatment of Ovarian Hyperstimulation Syndrome (OHSS) through literature research and overview. Methods: Database searching was conducted to identify relevant randomized controlled trials (RCTs) on oriental medicine for the treatment of Ovarian Hyperstimulation Syndrome. Studies were searched from Journal of Korean Obstetrics and Gynecology, Korean Medical Database, Korean studies Information Service System, China National Knowledge Infrastructure, Cochrane library, PubMed and EmBase up to 21st May, 2020. Results: Seventeen studies were finally selected. Fifteen studies intervened with oral Chinese herb medicine, two studies intervened with acupuncture and moxibustion. Nine studies concluded that intervention with oriental medicine significantly relieved OHSS symptoms. Three studies reporting ovary diameter, four studies reporting abdominal circumference and other four studies reporting pelvic effusion showed significant reduction compared to control groups. Six studies showed significantly shorter duration for hospitalization in intervention groups. Only one study showed significantly higher pregnancy rate. Factors related with vascular permeability and blood cell coagulation were significantly lowered in intervention groups in general. Conclusions: From seventeen studies, oriental medicine relieved OHSS symptoms and showed treatment effectiveness. Further strictly designed studies and long-term observed studies are needed to establish evidences.

General Pharmacology of DA-125, A New Anthracycline Anticancer Agent (새로운 Anthracycline계 항암제 DA-125의 일반약리작용)

  • Kim, Myung-Suk;Park, Jong-Wan;Kim, Young-Hoon;Kim, Soon-Hoe;Shin, Myeong-Soo;Kim, Won-Bae;Yang, Junn-Ick
    • The Korean Journal of Pharmacology
    • /
    • v.30 no.2
    • /
    • pp.227-242
    • /
    • 1994
  • The general pharmacological effects of a new anthracycline anticancer agent, DA-125 $[7-0-(2,\;6-dideoxy-2-fluoro-{\alpha}-L-talopyranosyl)-adriamycinone-14-{\beta}-alaninate{\cdot}HCI]$ were investigated in mice, rats, guinea pigs, rabbits and dogs. Intravenous administration of DA-125 presented no significant effects on the central and peripheral nervous systems of ICR mice except a decrease in the numbers of acetic acid-induced writhing response at a dose of 10 mg/kg. In anesthetized rats and dogs, DA-125 produced a transient depression of blood pressure and an increase in heart rate, but did not affect the peripheral blood flow in the isolated ear vessels of rabbits and the mechanical functions of the isolated hearts of guinea pigs. No significant effects were observed on the gastrointestinal functions and the contractilities of smooth muscle preparations obtained from guinea pig trachea, rabbit ileum, pregnant and non-pregnant uterus and vas deferens of rats. DA-125 Increased the contractility of the isolated ileum of guinea pigs in a dose range of $10^{-6}{\sim}10^{-9}g/ml$, and also increased, but weaker than adriamycin, the vascular permeability in rat skin. DA-125 had no effect on the kallikrein-induced increase in permeability and the permeability of the visceral organs. DA-125 did not adversely affect the liver function and the blood coagulation system, and did not induce hemolysis in vitro. It is concluded from the results that the general pharmachological effects of DA-125 are similar to or weaker than those of adriamycin, and that little adverse effects are anticipated with a therapeutic dose range.

  • PDF

PTCR Characteristics of Multifunctional Polymeric Nano Composites (PTCR 나노 복합기능 소재의 전류 차단 특성 연구)

  • 김재철;박기헌;서수정;이영관;이성재
    • Polymer(Korea)
    • /
    • v.26 no.3
    • /
    • pp.367-374
    • /
    • 2002
  • Electrical characteristics of crystalline polymer composites filled with nano-sized carbon black particle were studied. The developed composite system exhibited a typical positive temperature coefficient resistance (PTCR) characteristic, where the electrical resistance sharply increased at a specific temperature. The PTCR effect was sometimes followed by a negative temperature coefficient resistance (NTCR) feature with temperature, which seemingly caused by the coagulation of nano-sized carbon black particles in the excessive quantity. The PTCR temperature was controlled by the carbon black content and the external voltage. The change of electric conductivity was shown as a function of carbon black content, and the resistance was constant when the carbon black content was over 20 wt%. The room-temperature resistance was maintained by a repeated heating and cooling. The excellent PTCR characteristic was demonstrated by the low resistance in the initial stage and the instantaneous heating capability.

Development and Performance Evaluation of a Liquid Particle Generator (액적 발생 장치 개발 및 성능 평가)

  • Heo, Jung-Hyuk;Kim, Dae-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4334-4340
    • /
    • 2012
  • In this work, we developed and evaluated the Liquid Particle Generator for generating fine particles in the air. The Liquid Particle Generator, which was based on the spray-evaporation method, had two kinds of orifices: 0.3 mm and 0.5 mm. The Liquid Particle Generator was operated at different pressure between 1 bar and 4 bars to find relationship between input pressure and droplet output rate. In addition, the size distribution of the droplets generated by the Liquid Particle Generator with different orifices was measured by the SMPS system and the optical particle counter. As a result, it was shown that the Liquid Particle Generator with 0.3 mm orifice generated droplets of around 0.3 ${\mu}m$ and atomized particles very stably. The Liquid Particle Generator having 0.5 mm orifice generated bigger droplets, compared with the Liquid Particle Generator with 0.3 mm orifice. Additionally, in these Liquid Particle Generators (0.3 mm and 0.5 mm orifice), little coagulation of particles did occur because of fine droplets atomized by the jet. Therefore, the Liquid Particle Generator could be used as an aerosol generator for atomizing fine particles.

Phosphorus Removal and Operating Performance of Mesh Filtration Bio-reactor with the Addition of Alum (Alum 주입 메쉬 침지 여과분리형 생물반응조의 운전 특성과 인 제거)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.458-463
    • /
    • 2005
  • Considering the characteristics of a filtration bio-reactor equipped with a mesh filter module which can effectively maintain high concentration of biomass and enhanced solid-liquid separation performance, the hybrid process of filtration bio-reactor combined with coagulation was investigated to get improved filtration characteristics as well as water quality in this work. Two bio-reactors (Run-1 & Run-2) were operated under the following conditions: working volume of 25 L, continuous loading of a synthetic wastewater (BOD: 200 mg/L, T-N: 50 mg/L, T-P: 5 mg/L), where an appropriate amount of alum ($Al_2(SO_4)_3{\cdot}18H_2O$) was added once a day into the reactor (Run-2). In the system without using a alum (Run-1), the clogging of mesh filter module was observed two times through 85 days of whole operation. Meanwhile, the filter module did not clog even at higher MLSS concentration (6,000~12,000 mg/L) and the stable filtration (0.7 mid) was continued in the case of using a alum. Due to the stable formation of cake layers, BOD and SS were shown below 6 and 3 mg/L, respectively. T-P and pH of the effluent were changed because of the intermittent addition of the alum. In the case of Al/P=2.5, the average T-P removal efficiency per day was 85.2% and the average T-P concentration of the effluent was 0.3 mg/L. However, the removal efficiency of phosphate was influenced by pH in the reactor.