• Title/Summary/Keyword: Coagulant Rate

Search Result 124, Processing Time 0.026 seconds

Modeling of Particle Removal in the Coarse Media of Direct Horizontal-Flow Roughing Filtration (Direct Horizontal-Flow Roughing Filtration의 조립 여상에서의 입자 제거 모델링)

  • Ahn, Hyo-Won;Park, No-Suk;Lee, Sun-Ju;Lee, Kyung-Hyuk;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.338-347
    • /
    • 2005
  • Horizontal-Flow Roughing Filtration (HRF) is one of altemative pretreatment methods e.g. prior to Slow Sand Filtration (SSF). However, some of its limitations are that the effluent quality drops drastically at higher turbidity (>200 NTU) and at higher filtration rate (>1 m/h). To overcome these drawbacks, we suggested Direct Horizontal-Flow Roughing Filtration (DHRF), which is a modified system of Horizontal-Flow Roughing (HRF) by addition of low dose of coagulant prior to filtration. In this study to optimize the DHRF configuration, a conceptual and mathematical model for the coarse compartment has been developed in analogy with multi-plate settlers. Data from simple column settling test can be used in the model to predict the filter performance. Furthermore, the model developed herein has been validated by successive experiments carried out. The conventional column settling test has been found to be an handy and useful to predict the performance of DHRF for different raw water characteristics (e.g. coagulated or uncoagulated water, different presence of organic matter, etc.) and different inital process conditions (e.g. coagulant dose, mixing time and intensity, etc.). An optimum filter design for the coarse compartment (grain size 20mm) has been found to be of 3 m/h filtration rate with filter length of 4-4.5 m.

The Effects of Mixer Geometry on Hydraulic Turbulence : Computational Modeling (3-D 전산유체를 이용한 급속혼화조 형상에 따른 난류 유동장 연구)

  • Park, No-Suk;Kim, Sung-Hoon;Park, Heekyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1173-1182
    • /
    • 2000
  • The rapid mixing process has been considered as an important step in water treatment. Since the coagulant dispersion into raw water by rapid mixer can influence on the flocculation and filtration efficiency, many researchers have developed various devices and mixing methodologies. Until now, they focused attention on only coagulant dose, pH. rotating velocity and G value but overlooked the real turbulent flow and mixer geometry in rapid mixer. Therefore this paper questions the significance of turbulent flows in rapid mixer and focuses on the analysis of turbulent fluid in various mixer geometry with CFD(Computational Fluid Dynamics). The results of the jar-tests using various geometries indicate that the turbidity removal rate in a circular jar without baffle is higher than that of a circular with baffle. And the turbidity removal rate in Hudson jar is also founded to be higher than in the circular jar with baffle. The CFD simulation of velocity fields in jar demonstrates that the differences of removal rates among the various geometries are largely due to the formation of the different turbulent fluids fields with different geometries.

  • PDF

Effect of Metal Salt Coagulant on Membrane Fouling During Coagulation-UF Membrane Process (응집-UF 막 공정의 적용시 금속염 응집제가 막오염에 미치는 영향)

  • Jung, Chul-Woo;Shim, Hyun-Sool;Sohn, In-Shik
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.523-528
    • /
    • 2007
  • The objectives of this research are to investigate the mechanism of coagulation affecting UF, find out the effect of metal salt coagulant on membrane fouling. Either rapid mixing + UF or slow mixing + UF process caused much less flux decline. For PACl coagulant, the rate of flux decline was reduced for both hydrophilic and hydrophobic membrane than alum due to higher formation of flocs. In addition, the rate of flux decline for the hydrophobic membrane was significantly greater than for the hydrophilic membrane, regardless of pretreatment conditions. In general, Coagulation pretreatment significantly reduced the fouling of the hydrophilic membrane, but did little decrease the flux reduction of the hydrophobic membrane. When an Al(III) salt is added to water, monomers, polymers, or solid precipitates may form. Different Al(III) coagulants (alum and PACl) show to have different Al species distribution over a rapid mixing condition. During the rapid mixing period, for alum, formation of dissolved Al(III) (monomer and polymer) increases, but for PACl, precipitates of $Al(OH)_{3(s)}$ increases rapidly. This experimental results pointed out that precipitates of $Al(OH)_{3(s)}$ rather than dissolved Al(III) formation is major factor affecting flux decline for the membrane.

The Experimental Study of Predicting Optimum Dosage of PAC Using Jar-Test Results (Jar-Test를 이용(利用)한 응집제(凝集劑) 주입율(注入率) 결정(決定)에 관한 실험연구(實驗硏究))

  • Kim, Hong Seog;Kim, Seong Heon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.7 no.2
    • /
    • pp.39-46
    • /
    • 1993
  • In this experimental study, it is concerned to develop a simple equation using jar-test results in order to predict the optimum dosage of coagulant, PAC(polyaluminum chloride). Considering the relationships with the reactions of coagulation and flocculation, the four independent variables (e.g. turbidity, temperature, pH and alkalinity) are selected out of many parameters and they are put into calculations to develop an equation by means of multi-regression method. As the result, the dosing rate of PAC is proportional to turbidity, pH and alkalinity, but in inverse to temperature. And the developed equation is as follow, $$D_c=\frac{3.2{\cdot}T^{0.37}{\cdot}A^{0.04}{\cdot}P^{0.5}}{t^{0.1}},\;(R^2=0.9443)$$ And also, comparing between the estimated value from the equation and the real dosing rate in the plant, Kwangam and Tdukdo, during 1988~1991, it is represented an agreement having a relative error of 16.4%, 17.8%, respectively.

  • PDF

Analytical Studies on Leaching of Plasticizers from Medical Grade Polyvinyl Chloride Containers (폴리염화비닐 의료용기의 가소제의 정량 및 용출에 관한 연구)

  • Lee, Min-Hwa
    • Journal of Pharmaceutical Investigation
    • /
    • v.16 no.3
    • /
    • pp.106-109
    • /
    • 1986
  • The elution of di(2-ethylhexyl) phthalate (DEHP) from flexible bags into human blood or transfusion was studied. The conditions of determination of DEHP using high performance liquid chromatography (HPLC) was established as follows: Condition I-column, ${\mu}-Bondapak^{TM}\;C_{18}$; mobile phase, methanol: water=91 : 9 ; flow rate, 1.2ml/min; wavelength, 254nm; injection volume, $10{\mu}l$. Condition II-column, Lichorsorb RP-18$(10{\mu}m)$; mobile phase, methanol: water=94 : 6 ; flow rate, 1.1ml/min; wavelength, 254nm; injection volume, $10{\mu}l$. DEHP was found to be migrating from PVC blood and total parentral nutrient bags into methanol, but not into anti, coagulant drug solution.

  • PDF

Evaluation of Design Parameter on Residuals Treatment Facilities in Membrane Water Treatment Plants (막여과 정수장에서의 배출수처리시설 설계인자 평가)

  • Moon, Yong-Taik;Seo, In-Seok;Kim, Hong-Suck;Park, No-Suk;Ahn, Hyo-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.138-146
    • /
    • 2006
  • The characteristics of backwash and concentrate discharges depend upon the quality of the water being treated and the net recovery of the membrane system. This paper is to indicate a design methods on the capacities of residuals treatment facilities in membrane processes for drinking water. We operated a demonstration membrane plant with a recovery rate of 90% for designing G-water treatment plant. We investigated on design parameter (optimum coagulant dosage and surface loading rate etc.) to design efficiently the residuals treatment facilities. The settling test was conducted with 1m columns dosing PACl to kaolin and membrane residuals under the experimental condition that discharge permit was under a 60mg/L. When the quantity of membrane residuals was $1,575m^3/day$, the estimated results for 1st thickener demonstrated the surface loading rate of 14.4m/day, detention time of 5.83hr, available depth of 3.5m.

Removal of Microalgae Using Inorganic Coagulants in Coagulation and Sedimentation Processes for Water Treatment (응집.침전공정에서 무기고분자응집제를 이용한 미세조류의 제거)

  • Cheong, Cheong-Jo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.1
    • /
    • pp.85-89
    • /
    • 2008
  • The purpose of this study is to understand the removal possibility of microalgae using inorganic coagulants in coagulation and sedimentation process for water treatment. Removal of microalgae was studied according to coagulant type(Alum and PAC), coagulation factors(alkalinity, coagulant dosage, and setting time), and size fraction of microalgae. The contribution of applied coagulants for removal of microalgae was also examined. The removal rate of the microalgae by change of alkalinity was most high in 25 mg/L of alkalinity(Alum) as 87.2% and 30 mg/L of that(PAC) as 90.1%. Optimal coagulant dosage to remove the microalgae was 40 mg/L(removal effi.; 88.1%), and PAC was 50 mg/L(removal effi.; 90.1%). Alum was better than the PAC to remove the microlgae. In the water treatment processes such as rapid slow mixing and sedimentation the removal efficiency of microalgae with coagulants was 2 times higher than that of without. In optimal condition, the removal efficiencies of microalgae were nanoplankton > microplankton > picoplankton. Especially, the removal efficiency of the picoplankton was very low as below 30%.

Removal Improvement in Water Treatment Plant for Occurrence of Diatoms (Synedra sp.) in the Nakdong River (낙동강유역 상수원의 규조류 발생에 따른 정수장에서 제거율 향상 방안)

  • Kim, Min-Chai;Kim, Ji-Hoon;Seo, Gyu-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.1
    • /
    • pp.29-34
    • /
    • 2014
  • This study was conducted to investigate removal characteristics for Synedra sp. and filter run time (FRT) according to the cell length in the Nakdong River. When used alone flocculent, the removal efficiency for Synedra tenera (around $100{\mu}m$) was constant with 90.9~94.4%, while Synedra acus (around $300{\mu}m$) had the lower removal efficiency as 60~70%. $PACS_2$ and PAC showed 5~6% higher removal for S. acus than others (HiB and LAS). When added coagulant aid, loess had no effect and also needed more amount of flocculent. Sodium Silicate increased the removal rate by max 10.6%. On the other hand, 2.5 mg/L of Polyamine showed 96.9% removal efficiency for S. acus increasing up to 25% more than $PACS_2$ alone. In the effect of water temperature, the removal for S. acus at $15^{\circ}C$ were 6% higher than at $4^{\circ}C$. There was no significant correlation between the removal efficiencys of turbidity and S. acus. The results of this study was similar to the actual water treatment process's removal characteristics for Synedra sp. depending on the cell length and temperature. In the actual process, the numbers of Synedra in settled water was established natural logarithm function with the filter run time (FRT), so we can predict FRT as Synedra numbers.

A Study on Purification of Water Works by Multi-filter Bed Method with Aeration(Appliction of Biological Oxidation by Aerobic Microorganism) (상수 정화법에 관한 연구 (폭기식 다단여과에 의한 호기성균의 생물화학적 산화작용을 응용))

  • Chung, Yo-Han;Moon, Jae-Kyu;Jhoo, Heung-Kyu;Seo, Hwa-Jung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.5 no.1
    • /
    • pp.43-48
    • /
    • 1972
  • 5 bed sand filter, applying biological oxidation, was designed and studied on the treatment of water works. Never using any coagulant agent (drugs), which may cause water pollution in pre-treatment of head water, the auther attempt a high rate filtration by the microorganism (nitrofication bacteria) end plant which populate in multi layer sand beds. The result are as follows : In order to evaluate the oxygen effect on filtration, oxygen was injected in aeration tank attached to each filter tank while filtration, and $NH_3$ was tested as a representaiive ingredient. It was found out that the aeration method was more effective, with over 33% of $NH_3$ removal capacity, than the anerobic and this 5 bed filter showed double removal capacity of $NH_3$ by comparing with conventional sand bed (2 stage bed). According to the examination of two kind of head water, pre-treated with coagulant agent and activated carton, the filtration capacity was affected by the polluted condition of head water, resulting that lower value of pollution and slower velocity of filtration showed more efficiency of $NH_3$ removal. In this experiment $NH_3$ content tested in treated water had a fairly good correlation with others.

  • PDF

Co-precipitation of Turbidity and Dissolved Organic Matters by Coagulation (응집(凝集)에 의한 탁도물질(濁度物質) 및 용존(溶存) 유기물질(有機物質)의 동시제거(同時除去)에 대한 연구(硏究))

  • Jeong, Sang-Gi;Jun, Hang-Bae;Kim, Hag-Seong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.3
    • /
    • pp.99-107
    • /
    • 1995
  • Various humic substances are widely distributed in natural water body, such as rivers and lakes and cause the yellowish or brownish color to water. The evidence that humic substances are precursors of THMs formation in chlorinated drinking water has been reported m the Jiteratures. For the reason of public health as well as aesthetics, needs for humic substances removal have been increased in the conventional water treatment processes. In this research, the characteristics of aluminium coagulation of humic acids and humic acids were investigated. The optimum pH and coagulants dosage to remove these materials simultaneously by coagulation were alto studied. The results are as followed; 1. UV-254 absorptiometry for measuring the concentration of aquatic humic acids showed good applicability and stable results. 2. The optimal pH range for humic acids removal by aluminium coagulation was 5 to 5.5, however, an increase in aluminium coagulant dosage could enhance the removal rate of humic acids in the wide pH range. 3. Coprecipitation of humic acids in the typical pH range of 6.5 to 8 in water treatment processes may require the sweep coagulation mechanism with the excess aluminium coagulant dosage. 4. Using PAC(poly aluminium chloride) or PASS(poly aluminium silica sulfate) as coagulants was able to expand the operating range for removing humic acids. 5. From the coagulation of humic substances(UV-254) and turbidity at pH range of 5.5 - 6.0 and alum dose of 86 ppm, the removal efficiency of turbidity from the reservoir water was above 90% and that of UV-254 was above 70%. 6. By using the reservoir water, the optimum condition of rapid mixing for simultaneous removal of turbidity and UV-254 absorbance was pH of 5.8 and LAS dose of 86 ppm, in this study.

  • PDF