• Title/Summary/Keyword: Coagulant Rate

Search Result 124, Processing Time 0.024 seconds

Improvement of Cooling Water Quality by Coagulation and Sedimentation in Steel Mill (응집침전에 의한 제철공장 냉각수질향상)

  • Jo, Kwan-Hyung;Woo, Dal-Sik;Hwang, Byung-Gi;Lee, Seon-Ju;Park, Duck-Weon
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.5
    • /
    • pp.411-416
    • /
    • 2009
  • This study was initiated to improve the cooling water quality by chemical coagulation and sedimentation in steel mills. Due to the inefficient flocculation in the settling tanks of blast furnace cooling water systems, the solid particles in the cooling water overflow accumulate and clog the cooling system. To protect the cooling water system from such fouling, proper flocculants must be continuously used. Laboratory tests were performed for the indirect cooling water system of a plate mill. The batch test in the gas scrubbing cooling water system of a blast furnace showed that the proposed coagulant was more effective for the improvement of coagulation and sedimentation than the existing one. During the tests, cationic flocculants were more effective than use of only an anionic flocculant. The suggested combination of anionic and cationic flocculants can probably improve the turbidity removal efficiency of the cooling water. Proper control of the overflow rate by the designed residence time would help turbidity removal efficiency in the settling tank. In addition, the settling can be enhanced by adopting rapid and slow mixing alternatively. Scale problems in blast furnace cooling water system were reduced to some extent by efficient settling.

Effects of membrane fouling formation by feed water quality and membrane flux in water treatment process using ceramic membrane (세라믹 막여과 정수처리 공정에서 유입수질 및 막여과유속이 막오염 형성에 미치는 영향)

  • Kang, Joon-Seok;Park, Seo-Gyeong;Lee, Jeong-Jun;Kim, Han-Seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.77-87
    • /
    • 2018
  • In this study, the effects of operating conditions on the formation of reversible and irreversible fouling were investigated in the filtration using ceramic membrane for water treatment process. The effect of coagulation pretreatment on fouling formation was also evaluated by comparing the performance of membrane filtration both with and without addition of coagulant. A resistance-in-series-model was applied for the analysis of membrane fouling. Total resistance (RT) and internal fouling resistance (Rf) increased in the membrane filtration process without coagulation as membrane flux and feed water concentrations increased. Internal fouling resistance, which was not recovered by physical cleaning, was more than 70% of the total resistance at the range of the membrane flux more than $5m^3/m^2{\cdot}day$. In the combined process with coagulation, the cake layer resistance (Rc) increased to about 30-80% of total resistance. As the cake layer formed by coagulation floc was easily removed by physical cleaning, the recovery rate by physical cleaning was 54~90%. It was confirmed from the results that the combined process was more efficient to recover the filtration performance by physical cleaning due to higher formation ratio of reversible fouling, resulted in the mitigation of the frequency of chemical cleaning.

The Removal of Algae by Pre-oxidation (전산화 공정을 이용한 조류제거)

  • Son, Hee-Jong;Jung, Chul-Woo;Bae, Sang-Dae;Choi, Young-Ik;Kang, Lim-Seok
    • Journal of Environmental Science International
    • /
    • v.18 no.3
    • /
    • pp.289-298
    • /
    • 2009
  • The blue-green algae which caused odor problem in the tap water are difficult to precipitate in sedimentation basin and clogged the filter void rapidly. The studies of this paper were not only oxidation, coagulation and sedimentation processes for effectively removing blue-green algae but yellow clay and polyamine for verification as coagulants aids. The results of this research are summarized as follows: Higher ozone dose(C) and longer contact time(T) were needed for a high degree of removing blue-green algae efficiency. the removal rate of blue-green algae was proportional to the $C\times T$ value. The removal percent of chlorophyll-a by sedimentation and filter without pre-ozonation was about 75% but 1 mg/L pre-ozonation could increase the removal percent of chlorophyll-a to 99% and more pre-ozonation could remove completely. Though the removal efficiency of turbidity could increased by high dose of chlorination, the dissolved organic carbon was increased. More chlorine dose from 4 to 10 mg/L dissolved organic carbon was decreased. Using yellow clay as coagulant aids increased density of floc so the settling velocity of floc become rising but polyamine could not increase settling velocity of floc though it could formated large floc.

A Study on the Elimination of Microcystis sp. using Microbubble (미세기포를 이용한 Microcystis sp. 제거에 관한 연구)

  • Hyung, Sung-Hee;Lee, Kap-Du;Park, Sang-Won
    • Journal of Environmental Science International
    • /
    • v.25 no.3
    • /
    • pp.425-438
    • /
    • 2016
  • This study carried out zeta potential measurements of the Microcystis sp. under various solutions condition and investigated the characteristics of Microcystis sp. through the size control of microbubbles to eliminate algae that causes problems in aquatic ecosystems and human activities. DAF process was adopted and several coagulants were used to remove the Microcystis sp. CCD Camera was used to measure and analyze the size of microbubble, and fluorescent microscope was used to observe the particle, algae species and community. Zeta potential behavior of the algae was analyzed by using ELS-Z. Lab-scale and pilot-scale experiments were conducted to test flotation process. Polyaluminium chloride(PAC) coagulant was used, and the removal efficiency of the algae was assessed through Chlorophyll-a analysis. In the Lab-scale experiment, 2.2 ppm, 11 ppm, 22 ppm, and 44 ppm of polyaluminium chloride was injected to coagulate the algae. The coagulated algae was floated by the microbubble. The microbubbles in the experiments were generated at a air pressure of 450 ~ 550 kPa. The microbubble size was controlled in $36{\mu}m$, $100{\mu}m$, and $200{\mu}m$, respectively by using different diffuser. The results of lab-scale experiments on flotation plant indicated that the average removal rate was about 90% or above for 11 ppm, 22 ppm, and 44 ppm of polyaluminium chloride. On the other hand, in the pilot-scale experiment, the removal efficiency was in the range of 85% to 95% in all dose ranges of polyalumium chloride and aluminium sulfate coagulants.

A Study on Removal of Dissolved Organic Matter and Phosphorus in Eutrophic Lake by Coagulation Process Using Powdered Activated Carbon (분말활성탄 응집침전 공정을 이용한 부영양화 호소수의 용존 유기물 및 인의 제거 연구)

  • Cho, Kyung Chul;Lee, Min Hee;Park, Jung Hwan;Jung, Jongtai
    • Journal of Wetlands Research
    • /
    • v.14 no.4
    • /
    • pp.629-635
    • /
    • 2012
  • This study was conducted to evaluate the removal behaviors of DOM(dissolved organic matter) and phosphorus in eutrophic lake water by coagulation process with PAC(powdered activated carbon). It was observed that the removal characteristic of soluble matter was different from that of dissolved one, and the removal of DOM was effected by both pH and coagulant dosage. It was founded that PAC could increase the removal efficiency by an adsorption of DOM in coagulation process. A formation of soluble and colloidal matters resulted in the degradation of phosphorus removal efficiency in a chemical precipitation process. The phosphorus removal efficiency could be enhanced by an absorption of colloidal matter and dissolved complex with PAC addition. In addition, the PAC addition caused the increase of floc density in coagulation process, that led to the rise of sedimentation rate, and resulted in a significant improvement of solid-liquid separation efficiency.

An Experimental Study on Engineering Characteristics of Wet Dredged Soil and Dry Dredged Soil after Chemical Treatment (습윤준설토와 노건조준설토의 약품처리 후 공학적 특성에 관한 실험적 연구)

  • Chang, Yongchai;Park, Kiyoun;Park, Jongcheol;Lee, Ingyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.3
    • /
    • pp.71-76
    • /
    • 2012
  • Since sediment in a stable state is disturbed during the process from sediment in a natural state to dredged soil, the turbidity of water is not good. When the dredged soil settles again, the volume change in the sediment occurs. Coagulant and flocculant are added for turbidity mitigation of the water and faster settling process of suspended solid, and the amount of the substances affects the characteristics of the dredged soil. This study is to investigate the characteristics of the dredged soil depending on the amount of three chemical products added to the wet dredged soil and the dry dredged soil through measuring the suspended solids (SS), volume change and sedimentation velocity. The experimental measurements show that the SS decreased, the volume change rate increased, and the sedimentation velocity increased, as the chemical amount increased. In addition, it was found that the dry dredged soil reacted even with little quantity of the chemicals because derelict and microorganism are removed due to the drying process at $100{\pm}5^{\circ}C$.

Evaluation of Solids Removal Characteristics on Sewage Treatment Plants Using T-P sludge Return into the Primary Settling Tank (총인슬러지의 1차 침전지 반송에 따른 하수처리장 고형물 제거특성 연구)

  • Kim, Jong-Oh;Jung, Dong-Gi;Kwon, Hye-Jeong;Hwang, Joon-Seok
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.73-80
    • /
    • 2018
  • In this study, the solids removal characteristics using T-P sludge generated from PACl coagulation were analyzed by laboratory scale and full scale experiment. As the amounts of T-P sludge injection into the raw sewage influent increased at the rate of 0, 1, 2, 3, 4 %, the suspended solids concentrations after 20 minutes setting test decreased to 210, 137, 91, 64, 43 mg/L, respectively. The filtration time required for dewatering test of the raw sewage influent decreased to 982, 728, 658, 581, 492 sec for 0, 1, 2, 3, 4% of T-P sludge injection, respectively. As the amounts of PACl coagulant into the effluent from final setting tank increased at 0, 10, 20, 30, 40 mg/L, the required filtration times for T-P sludge increased into 12.3, 41.7, 53.7, 67.2, 79.5 sec and the dewaterability of T-P sludge decreased. After T-P sludge returned into the primary settling tank on J-si sewage treatment plants, the effluent concentrations of COD, SS, T-N and T-P from primary settling tank into bioreactor decreased by 35.9, 27.9, 22.2, and 52.6% due to the coagulation effects of the T-P sludge. Finally, it was found that the return of T-P sludge into the primary settling tank could result into the sludge reduction having a lower water content of 3.03% p than in case of the only T-P sludge dehydration.

Evaluation of Pressurized Water Mixing of Big Pipe with CFD at Water Treatment Process (CFD를 활용한 수처리공정 대형관에서 압력수 혼합공정 평가)

  • Cho, Young-Man;Yu, Hyun-chul;Jang, Gyeong-Hyuk;Jung, Yong-Jun
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.3
    • /
    • pp.168-174
    • /
    • 2021
  • Mixing is a very important unit in water treatment process. A mechanical stirring method is generally used for mixing, but recently, the use of pressurized water mixing method (pump diffusion flash mixer) has gained interest because it is more advantageous in terms of mixing time, noise, energy consumption, and maintenance. The following conclusions were obtained from the study of pressurized water mixing method by Computational Fluid Dynamics. Firstly, the mixing degree in the pipe increased as the density of water increased. Secondly, even if the relative velocity between flow rate in the pipe and the pressurized water was constant, the mixing degree decreased as the flow velocity in the pipe increased. Thirdly, the stronger the injection energy the higher the mixing degree. It was also found that the mixing degree was greatly affected by the injection velocity as compared to the injection flow amount. Finally, the required energy to achieve 95% mixing degree at the distance of 10 times diameter in big pipes of 500 mm to 3000 mm was 0.3 to 4.5 kJ. The result of this study could be used in the process design of injection with water purification chemicals, such as, ozone, chlorine, and coagulant.

Treatment of Phosphorus and Suspended Solid in Reject Water of Sewage Using an Integrated Slow Mixing/Sedimentation and Net Fit Fiber Filtration System (일체형 완속교반/침전 그물망 압착식 섬유여과장치를 이용한 하수처리장 반류수 내 고농도 인 및 부유물질 처리)

  • Kim, Jeongsook;Kim, Min-Ho;Kim, Mi-Ran;Jang, Jeong-Gook
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.816-821
    • /
    • 2017
  • An integrated slow mixing/sedimentation and net fit fiber filtration system has been developed to reduce the high concentrations of suspended solid (SS) and total phosphorus (T-P) in the reject water from sewage/wastewater. A filtration device used in this experiment consists of coagulation, in-line mixing, air injection, slow mixing/sedimentation, and filtration processes. The performance test using this device was carried out with six operational modes for reject water from sewage treatment plant. Experimental conditions used were 16.7, 33.3, 41.7 and 50.0 ton/day of flow rate and 2~4 of Al/P molar ratio. By injection of coagulant in each operational mode, the high removal efficiencies of SS and T-P were obtained, but continuous operation time was decreased to 7.8~11.4 min in most modes. However, when the Mode 5 of the developed filtration device was applied, the continuous operation time was maintained up to 88.2 min. Also, it was found that the continuous operation time in the Mode 5 using the developed system was increased from 8 to 11.3 times longer than those in other modes. Backwashing flow rate was also very low at 5.4% of total filtered water. Therefore, it can be concluded that the Mode 5 of the developed filtration system was the most efficient treatment method for the removal of high concentrations of SS and T-P.

Evaluation of Biological Aerated Filter Position on Water Treatment Processes for Water Quality Improvement (상수원수 전처리 시 효율향상을 위한 생물여과 반응기 위치선정)

  • Choi, Hyung-Joo;Choi, Dong-Ho;Bae, Woo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.677-686
    • /
    • 2006
  • This study was the effectiveness of two downflow BAF(Biological Aerated Filter) systems at conventional water treatment system. A BAF reactor placed in front of coagulation and sedimentation tanks(Mode A) and after coagulation and sedimentation tanks(Mode B) that were compared in terms of removal of suspended particles, organic matters, and ammonia nitrogen. The suspended particles removal efficiency was over 80% for both Mode A and B, although Mode A gave slightly better results. $BOD_5$ removal and nitrification efficiencies were more than 90% for both reactor. The organic matter and ammonia removals were also superior in the Mode A. The biofilm thickness and biomass increased as increment of EBCT and the upper part of reactor more about 30% than lower part. The specific oxygen uptake rate(SOUR) was higher the upper part of reactor and Mode A than the lower part of reactor and Mode B. A cost analysis showed that the Mode A system was more cost effectiveness. It could save the coagulant dose by about 67% and the chlorine demand by about 95%. The ideal place to put the BAF reactor was in front of the coagulation/sedimentation process.