• Title/Summary/Keyword: Coagulant Dosage Rate

Search Result 37, Processing Time 0.031 seconds

Treatment of Dye-Processing Wastewater by Chemical Precipitation (화학적 침전공정에 의한 염색가공폐수의 처리)

  • Han, Myung-Ho;Huh, Man-Woo;Kim, Jeong-Mog;Lee, Jin-Sik;Lim, Hak-Sang
    • Textile Coloration and Finishing
    • /
    • v.9 no.6
    • /
    • pp.26-32
    • /
    • 1997
  • In order to remove the pollutants effectively in the dye-processing wastewater by chemical precipitation, coagulation and flocculation test was carried out using several coagulants on various reaction conditions. It was found that the Ferric sulfate was best coagulant for the treatment of mixed dye-processing wastewater. When the Ferric sulfate dosage was 1,100mg/$\ell$, the COD removal rate was very high(50%), and the color was removed very effectively. The COD was decreased relatively well up to 40%, when Alum was dosed as coagulant. But it was difficult to remove the color effectively. Test results about COD removal for the Ferrous sulfate and the Ferric chloride used were mostly same as those of the Alum used. However, the color removal by the Ferrous sulfate was much better than the case of the Alum or the Ferric chloride. It was found that the COD removal was increased and the sludge yield was decreased by pH control before polymer flocculant addition, during the jar test for the Ferrous sulfate and the Ferric sulfate as a coagulant.

  • PDF

Co-precipitation of Turbidity and Dissolved Organic Matters by Coagulation (응집(凝集)에 의한 탁도물질(濁度物質) 및 용존(溶存) 유기물질(有機物質)의 동시제거(同時除去)에 대한 연구(硏究))

  • Jeong, Sang-Gi;Jun, Hang-Bae;Kim, Hag-Seong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.3
    • /
    • pp.99-107
    • /
    • 1995
  • Various humic substances are widely distributed in natural water body, such as rivers and lakes and cause the yellowish or brownish color to water. The evidence that humic substances are precursors of THMs formation in chlorinated drinking water has been reported m the Jiteratures. For the reason of public health as well as aesthetics, needs for humic substances removal have been increased in the conventional water treatment processes. In this research, the characteristics of aluminium coagulation of humic acids and humic acids were investigated. The optimum pH and coagulants dosage to remove these materials simultaneously by coagulation were alto studied. The results are as followed; 1. UV-254 absorptiometry for measuring the concentration of aquatic humic acids showed good applicability and stable results. 2. The optimal pH range for humic acids removal by aluminium coagulation was 5 to 5.5, however, an increase in aluminium coagulant dosage could enhance the removal rate of humic acids in the wide pH range. 3. Coprecipitation of humic acids in the typical pH range of 6.5 to 8 in water treatment processes may require the sweep coagulation mechanism with the excess aluminium coagulant dosage. 4. Using PAC(poly aluminium chloride) or PASS(poly aluminium silica sulfate) as coagulants was able to expand the operating range for removing humic acids. 5. From the coagulation of humic substances(UV-254) and turbidity at pH range of 5.5 - 6.0 and alum dose of 86 ppm, the removal efficiency of turbidity from the reservoir water was above 90% and that of UV-254 was above 70%. 6. By using the reservoir water, the optimum condition of rapid mixing for simultaneous removal of turbidity and UV-254 absorbance was pH of 5.8 and LAS dose of 86 ppm, in this study.

  • PDF

Optimum Coagulation Conditions for Ceramic Microfiltration Membrane Process (세라믹 정밀여과막 공정을 위한 최적 응집조건)

  • Lim, Jae-Lim;Lee, Kyung-Hyuk;Lee, Young-Joo;Park, Jong-Yul
    • Membrane Journal
    • /
    • v.22 no.2
    • /
    • pp.135-141
    • /
    • 2012
  • This study was carried out to find the optimum coagulation conditions for ceramic microfiltration process of Y water treatment plant. When pH of raw water from Y Dam was adjusted to 7, the efficiency of coagulation was the best and the optimun dosage of coagulant was 3 mg/L(as $Al_2O_3$) for turbidity of raw water less then 10 NTU in Jar test. In mini module test, the decay rate of specific flux was the lowest when PAC (poly Aluminum Chloride) was used among coagulants and pH was adjusted to 7. The decay rate of specific flux for raw water turbidity of 10~30 NTU was greatly decreased with increase of dosage of coagulant (PAC) while the rate was not significantly decreased for turbidity more than 50 NTU. In conclusion, the optimum dosage of PAC (11% as $Al_2O_3$) was 30 and 50 mg/L for raw water turbidity of less than 10 NTU and more than 50 NTU, respectively. The dosage of PAC should be increased linearly 30 to 50 mg/L depending on raw water turbidity of 10 to 50 NTU.

Treatment of Phosphorus Species using Iron Coagulation and Fenton Oxidation (철염 응집과 펜톤 산화를 이용한 인의 존재형태별 처리)

  • Park, Sung-Hwan;Moon, Byung-Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.6
    • /
    • pp.653-657
    • /
    • 2014
  • Effects of $H_2O_2$ addition for fenton oxidation on iron coagulation for treatment of phosphorus species, such as orthophosphate, metaphosphate, pyrophosphate, organic phosphate, were investigated. The effects of coagulant dosage, hydrogen peroxide dosage and the combined sequence ferric coagulation and $H_2O_2$ addition for fenton oxidation and coagulation were studied. The characteristics of floc growth rate were monitored using the PDA. The removal efficiencies of phosphorus species by iron coagulation were increased as Fe/P molar ratio increased. However, the removal efficiencies of metaphosphate, pyrophosphate, organic phosphate by a ferric coagulation were not increased as Fe/P molar ratio increased. The removal efficiency of metaphosphate, pyrophosphate, organic phosphate was increased by using iron coagulation and $H_2O_2$ addition for fenton oxidation. The result indicated that non-reactive phosphorus after iron coagulation was changed to reactive phosphorus by $H_2O_2$ addition for fenton oxidation and the oxidized iron enhanced the coagulation efficiencies.

Zeolite Filtration for Ammonium Nitrogen Removal in Drinking Water Treatment (정수처리에서 암모니아성질소 제거를 위한 제올라이트 여과)

  • 김우항;김충환
    • Journal of Environmental Science International
    • /
    • v.12 no.3
    • /
    • pp.281-286
    • /
    • 2003
  • This study was conducted to evaluate the feasibility of ammonia removal by zeolite adsorption in drinking water treatment. In generally, drinking water treatment process is conducted coagulation/flocculation, sedimentation, sand filtration and disinfection. We tested feasibility with two method, one is powdered zeolite dosing to coagulation tank and the other is to substitute granular zeolite for sand of sand filter. In powdered zeolite test, raw water is used tap water with putting of 2 mg/l of NH$_4$$\^$+/-N. Filtration of granular zeolite was conducted with 80 cm of effective column high and 120 m/d of flow rate. At above 100 mg/1 of zeolite dosage, ammonia concentration was decreased below 0.5 mg/l of NH$_4$$\^$+/-N in powdered zeolite test. But, turbidity was increased to 30 NTU by powdered zeolite dosage. That turbidity was scarcely decreased in generally coagulant using condition in drinking water treatment. In granular zeolite test, ammonia was not detected in treated water until 8 days. This result suggest that using of granular zeolite in sand filter could be removal ammonia in winter. But we need regeneration at zeolite filtration for ammonia removal. So, it is to make clear that zeolite regeneration ability was compared KCl with NaCl. The result reveal that KCl was more excellent than NaCl. Optimum regeneration concentration of KCl was revealed 100 mM. Regeneration efficient was not increased at pH range 10∼12.5.

Effect of coagaulation on ceramic microfiltration membrane fouling (응집공정이 세라믹 정밀여과막 파울링에 미치는 영향)

  • Hwang, Young Jin;Lim, Jae Lim;Choi, Young Jong;Wang, Chang Gun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.459-469
    • /
    • 2009
  • It is well known that coagulation pretreatment can reduce foulants prior to membrane filtration. The purpose of this research was to investigate the effects of coagulation on fouling of ceramic microfiltration membrane($0.1 {\mu}m$) using pilot plant of $150m^3/day/train$ capacity. Train A membrane system has pretreatment process of ozonation and coagulation while train B has only coagulation. Two types of coagulation operation were investigated: back mixer(rapid mixing with or without slow mixing) which is a conventional mechanically stirred mixer and an inline static mixer. Ozone dose rate for train A was 1 mg/L and ozone contact time was 12 min. The coagulation dose(PACl 10% as $Al_2O_3$) rate was changed 20~40 mg/L according to experimental schedule. In this experimental conditions, the coagulation of back mixer type with rapid mixing(GT=72,000) and slow mixing(GT=45,000) was the best effective in reduction of ceramic membrane fouling regardless preozonation. Especially, the effect of inline static mixer was sensitive to change in water quality. Ozonation mainly affected irreversible fouling rather than reversible fouling in accordance with less adsorption of NOM on the membrane surface. Thus, the increase rate of the nomalized TMP(trans membrane pressure) at $25^{\circ}C$ for train A was relatively lower than that of train B under same coagulation process with same coagulant dosage. The best performance of ceramic membrane appeared in case of combined process with ozonation, therefore this integrated process is able to archive less coagulant dosing and secure a stability of ceramic membrane system.

Removal of Microalgae Using Inorganic Coagulants in Coagulation and Sedimentation Processes for Water Treatment (응집.침전공정에서 무기고분자응집제를 이용한 미세조류의 제거)

  • Cheong, Cheong-Jo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.1
    • /
    • pp.85-89
    • /
    • 2008
  • The purpose of this study is to understand the removal possibility of microalgae using inorganic coagulants in coagulation and sedimentation process for water treatment. Removal of microalgae was studied according to coagulant type(Alum and PAC), coagulation factors(alkalinity, coagulant dosage, and setting time), and size fraction of microalgae. The contribution of applied coagulants for removal of microalgae was also examined. The removal rate of the microalgae by change of alkalinity was most high in 25 mg/L of alkalinity(Alum) as 87.2% and 30 mg/L of that(PAC) as 90.1%. Optimal coagulant dosage to remove the microalgae was 40 mg/L(removal effi.; 88.1%), and PAC was 50 mg/L(removal effi.; 90.1%). Alum was better than the PAC to remove the microlgae. In the water treatment processes such as rapid slow mixing and sedimentation the removal efficiency of microalgae with coagulants was 2 times higher than that of without. In optimal condition, the removal efficiencies of microalgae were nanoplankton > microplankton > picoplankton. Especially, the removal efficiency of the picoplankton was very low as below 30%.

Evaluation of Design Parameter on Residuals Treatment Facilities in Membrane Water Treatment Plants (막여과 정수장에서의 배출수처리시설 설계인자 평가)

  • Moon, Yong-Taik;Seo, In-Seok;Kim, Hong-Suck;Park, No-Suk;Ahn, Hyo-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.138-146
    • /
    • 2006
  • The characteristics of backwash and concentrate discharges depend upon the quality of the water being treated and the net recovery of the membrane system. This paper is to indicate a design methods on the capacities of residuals treatment facilities in membrane processes for drinking water. We operated a demonstration membrane plant with a recovery rate of 90% for designing G-water treatment plant. We investigated on design parameter (optimum coagulant dosage and surface loading rate etc.) to design efficiently the residuals treatment facilities. The settling test was conducted with 1m columns dosing PACl to kaolin and membrane residuals under the experimental condition that discharge permit was under a 60mg/L. When the quantity of membrane residuals was $1,575m^3/day$, the estimated results for 1st thickener demonstrated the surface loading rate of 14.4m/day, detention time of 5.83hr, available depth of 3.5m.

Application of Water Treatment with Membrane in Seomjin River (섬진강 수계에서 막여과 정수처리 공정 적용성 평가)

  • Kim, Jongdoo;Park, Kyungwook;Park, Chulhwi
    • Membrane Journal
    • /
    • v.23 no.1
    • /
    • pp.12-23
    • /
    • 2013
  • On the subject of river bed water in Seomjin river, it had accomplished the verifying experiment of membrane filtration pilot plant for evaluating the applicability of its process throughout the prediction of membrane fouling as a function of the pore size of membrane and the determination of optimum coagulant dosage. On the result of the experiment for the evaluation of the membrane fouling as a function of the pore size, a increasing rate of irreversible resistance of membrane pore size $0.1{\mu}m$ and $0.01{\mu}m$ was measured each $0.44{\times}10^{12}/m^2$ and $0.42{\times}10^{12}/m^2$, respectively. And on the result of Flux-test, it showed that the optimum coagulant dosage was measured lower than the it of the Jar-test. The result to be operated in a condition of a permeate flux $1.0{\sim}1.5m^3/m^2{\cdot}day$ without coagulation and a permeate flux $1.0{\sim}2.0m^3/m^2{\cdot}day$ with coagulation was maintained at stable trans-membrane pressure (TMP) value for 6 months up to. Therefore it showed that the stable operation without the coagulation was possible on permeate flux $1.0{\sim}1.5m^3/m^2{\cdot}day$ in the operation of membrane filtration process.

Effective correlation between coagulation efficiency and the sludge settling characteristic (슬러지 응집효율이 침강특성에 미치는 상관관계에 대한 연구)

  • Han, Gee-Bong;Yoon, Ji-Hyun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.1
    • /
    • pp.151-159
    • /
    • 2006
  • In these days, the importance of sludge treatment is emerging due to the London Convention, so this study was conducted to propose the alternatives for the improved sludge treatment on the organic wastewater and sewage sludge with JAR test and settling column equipped with stirrer. The minimum coagulant dosage to earn the optimum sludge settling efficiency resulted from 200mg/l and each critical sludge settling interface showed no distinct difference when PAC was dosed over 200mg/l. Accordingly, Clarification Rate(CR) with 200mg/l dosage was calculated to CR=(Ho-Ht) / Ho=1-0.4=0.6 because the critical sludge settling height stopped at 0.4. The settling velocity of sludge interface was decreased with the increase of MLSS concentration but rather increased with MLSS concentration over 1,000mg/l. This resulted from positive effect of interacted coagulation for floc formation by transfer to the zone of compressed settling when MLSS concentration increased over 1,000mg/l. The settling velocity of sludge interface showed $28.66{\times}10^{-3}/min$ for average settling velocity of sewage sludge which is 6.7 times higher than $4.25{\times}10^{-3}/min$ for average settling velocity of organic wastewater sludge. The increasing rate of CR for organic wastewater activated sludge was higher than that of settling velocity under 200mg/l of PAC dosage but settling velocity was higher than CR over 200mg/l of PAC dosage. However, in case of sewage sludge, the differential rate of CR was low when PAC dosage was increased but the settling velocity was suddenly increased with over 200mg/l dosage. Therefore coagulation effect was more efficient to MLSS settling velocity rather than SS removal effect in the supernatant.

  • PDF