• Title/Summary/Keyword: CoTi

Search Result 1,690, Processing Time 0.035 seconds

Occurrence and Chemical Composition of White Mica from Wallrock Alteration Zone of Janggun Pb-Zn Deposit (장군 연-아연 광상의 모암변질대에서 산출되는 백색운모의 산상 및 화학조성)

  • Bong Chul, Yoo
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.4
    • /
    • pp.469-484
    • /
    • 2022
  • The Janggun Pb-Zn deposit has been known one of the four largest deposits (Yeonhwa, Shinyemi, Uljin) in South Korea. The geology of this deposit consists of Precambrian Weonnam formation, Yulri group, Paleozoic Jangsan formation, Dueumri formation, Janggum limestone formation, Dongsugok formation, Jaesan formation and Mesozoic Dongwhachi formation and Chungyang granite. This Pb-Zn deposit is hydrothermal replacement deposit in Paleozoic Janggum limestone formation. The wallrock alteration that is remarkably recognized with Pb-Zn mineralization at this deposit consists of mainly rhodochrositization and dolomitization with minor of pyritization, sericitization and chloritization. Wallrock alteration is divided into the five zones (Pb-Zn orebody -> rhodochrosite zone -> dolomite zone -> dolomitic limestone zone -> limestone or dolomitic marble) from orebody to wallrock. The white mica from wallrock alteration occurs as fine or medium aggregate associated with Ca-dolomite, Ferroan ankerite, sideroplesite, rutile, apatite, arsenopyrite, pyrite, sphalerite, galena, quartz, chlorite and calcite. The structural formular of white mica from wallrock alteration is (K0.77-0.62Na0.03-0.00Ca0.03-0.00Ba0.00Sr0.01)0.82-0.64(Al1.72-1.48Mg0.48-0.20Fe0.04-0.01Mn0.03-0.00Ti0.01-0.00Cr0.00As0.01-0.00Co0.03-0.00Zn0.03-0.00Pb0.05-0.00Ni0.01-0.00)2.07-1.92 (Si3.43-3.33Al0.67-0.57)4.00O10(OH1.94-1.80F0.20-0.06)2.00. It indicated that white mica from wallrock alteration has less K, Na and Ca, and more Si than theoretical dioctahedral micas. The white micas from wallrock alteration of Janggun Pb-Zn deposit, Yeonhwa 1 Pb-Zn deposit and Baekjeon Au-Ag deposit, and limestone of Gumoonso area correspond to muscovite and phengite and white mica from wallrock alteration of Dunjeon Au-Ag deposit corresponds to muscovite. Compositional variations in white mica from wallrock alteration of these deposits and limeston of Gumoonso area are caused by mainly phengitic or Tschermark substitution mechanism (Janggun Pb-Zn deposit), mainly phengitic or Tschermark substitution and partly illitic substitution mechanism (Yeonhwa 1 Pb-Zn deposit, Dunjeon Au-Ag deposit and Baekjeon Au-Ag deposit), and mainly phengitic or Tschermark substitution and partly illitic substitution or Na+ <-> K+ substitution mechanism (Gumoonso area).

Preliminary Study on the Ultramafic Rocks from the Chungnam Province, Korea (충남지역에 분포하는 초염기성암의 기원규명을 위한 기초연구)

  • Wee, Soo-Meen;Choi, Seon-Gyu;So, Chil-Sup
    • Economic and Environmental Geology
    • /
    • v.27 no.2
    • /
    • pp.171-180
    • /
    • 1994
  • Several ultramafic bodies and ultramafic origin talc deposits are distributed in Chungnam province near the contact zone with Ogchun fold belt They occur as discontinued belt form with northeast trending, and most of them are more or less sepentinized. Major, trace, and rare earth elements analyses were made of the ultramafics from the study area to constrain their origin and genetic relationships. Compared to the primitive mantle estimates of privious workers, the correlations defined by the studied rock samples indicate similar Ni but very lower $Al_{2}O_{3}$, CaO and $TiO_{2}$ contents. It is inferred that source material of the studied rocks might be residual mantle which had undergone a large degree of partial melting event. The REE patterns show relatively flat to enriched in LREE (chondrite normalized La/Yb and Sm/Yb ratios are 1.1-5.2 and 1.2-1.6). Several alternative explaination are possible for LREE enrichment patterns in the studied ultramafic rocks such as 1) enrichment due to late stage alteration, 2) enriched pre-melting composition, and 3) mixing of two components. Based on the result, the LREE enrichment characteristic of the studied rocks might be result from the mixture of two geochemically distinct components; one is depleted residual mantle and the other component which determine the abundances of incompatible elements and responsible for the LREE enrichment.

  • PDF

Preparations of Universal, Functionalized Long-Chain Alkylthiol Linkers for Self-assembled Monolayers (자기조립단분자막을 위한 보편적이고 기능화된 긴 사슬 알킬티올 연결자의 제조)

  • Yoo, Dong-Jin;Lee, Kyong-Sub;Kim, Ae-Rhan;Nahm, Kee-Suk
    • Korean Chemical Engineering Research
    • /
    • v.49 no.3
    • /
    • pp.330-337
    • /
    • 2011
  • In this research, the preparation processes for making a series of $\omega$-mercapto alkylamine 1 and $\omega$-mercapto alkanoic acid 2 useful for studying of the self-assembled monolayer(SAM) are described. The preparation methods of the first goal materials, $\omega$-mercapto alkylamines 1 were carried out as follows: First, $\omega$-phthalimide alkanol 3 was synthesized from commercially available potassium phthalimide derivatives and $\omega$-bromoalkanol in DMF at $80{^{\circ}C}$ via substitution reaction. After refluxing $\omega$-phthalimide alkanol 3 with hydrazine hydrate in ethanol followed by treating with c-HCl, $\omega$-aminoalkanol 4 was obtained in 76-98% yield, accompanied with side-product 5. Bromination of hydroxyl moiety of $\omega$-aminoalkanol 4 using aqueous hydrobromic acid furnished $\omega$-bromoamine 6 in 34-97% yields. Substitution reaction 6 with thiourea in 95% ethanol gave $\omega$-aminoalkanthiuronium 7, which was treated with aqueous strong base and aqueous strong sulfuric acid gave desired products, $\omega$-mercapto alkylamines 1 through overall 5 steps. The second target material, $\omega$-mercapto alkanoic acid 2 was prepared via 2 steps. $\omega$-bromo alkanoic acid was reacted with thiourea to give $\omega$-thiourea alkanoic acid 7 in 69-85%, which was treated with aqueous strong base and strong acid to furnish $\omega$-mercapto alkanoic acid 2 in 50-98%. The fabricated long-chain alkylthiol(LCAT) can be used as linkers to immobilize protein, enzyme and various kinds of biomolecules on the surface of metallic materials(Au, Pt, Ti) by SAM, and can be useful chemical tools for the application study on the surface modification of metallic materials.

Electrochemical Characteristics of Dental Implant in the Various Simulated Body Fluid and Artificial Saliva (다양한 유사체액과 인공타액에서 치과용 임플란트의 전기화학적 특성)

  • Kim, T.H.;Park, G.H.;Son, M.K.;Kim, W.G.;Jang, S.H.;Choe, H.C.
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.5
    • /
    • pp.226-231
    • /
    • 2008
  • Titanium and its alloy have been widely used in dental implant and orthopedic prostheses. Electrochemical characteristics of dental implant in the various simulated body fluids have been researched by using electrochemical methods. Ti-6Al-4V alloy implant was used for corrosion test in 0.9% NaCl, artificial saliva and simulated body fluids. The surface morphology was observed using scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX). The electrochemical stability was investigated using potentiosat (EG&G Co, 263A). The corrosion surface was observed using scanning electron microscopy (SEM). From the results of potentiodynamic test in various solution, the current density of implant tested in SBF and AS solution was lower than that of implant tested in 0.9% NaCl solution. From the results of passive film stability test, the variation of current density at constant 250 mV showed the consistent with time in the case of implant tested in SBF and AS solution, whereas, the current density at constant 250mV in the case of implant tested in 0.9% NaCl solution showed higher compared to SBF and AS solution as time increased. From the results of cyclic potentiodynamic test, the pitting potential and |$E_{pit}\;-\;E_{corr}$| of implant tested in SBF and AS solution were higher than those of implant tested in 0.9% NaCl solution.

Characteristics of the Number and the Mass Concentrations and the Elemental Compositions of PM10 in Jeju Area (제주지역 PM10의 수농도 및 질량농도와 원소성분 조성 특성)

  • Kang, Chang-Hee;Hu, Chul-Goo
    • Journal of Environmental Science International
    • /
    • v.23 no.3
    • /
    • pp.447-457
    • /
    • 2014
  • The number concentrations, the mass concentrations and the elemental concentrations of $PM_{10}$ have measured at Gosan site in Jeju, Korea, from March 2010 to December 2010. And the correlation and the factor analysis for the number, the mass and the elemental concentrations of $PM_{10}$ are performed to identify their relationships and sources. The average $PM_{10}$ number concentration is observed $246\;particles/cm^3$($35.7{\sim}1,017\;particles/cm^3$) and the average $PM_{10}$ mass concentration is shown $50.1{\mu}g/m^3$($16.7{\sim}441.4{\mu}g/m^3$) during this experimental period. The number concentrations are significantly decreased with increasing particle size, hence the concentrations for the smaller particles less than $2.5{\mu}m$($PM_{2.5}$) are contributed 99.6% to the total $PM_{10}$ number concentrations. The highest concentration of the 20 elements in $PM_{10}$ determined in this study is shown by S with a mean value of $1,497ng/m^3$ and the lowest concentration of them is found by Cd with a mean value of $0.57ng/m^3$. The elements in $PM_{10}$ are evidently classified into two group based on their concentrations: In group 1, including S>Na>Al>Fe>Ca>Mg>K, the elemental mean concentrations are higher than several hundred $ng/m^3$, on the other hand, the concentrations are lower than several ten $ng/m^3$ in group 2, including Zn>Mn>Ni>Ti>Cr>Co>Cu>Mo>Sr>Ba>V>Cd. The size-separated number concentrations are shown positively correlated with the mass concentrations in overall size ranges, although their correlation coefficients, which are monotonously increased or decreased with size range, are not high. The concentrations of the elements in group 1 are shown highly correlated with the mass concentrations, but the concentrations in group 2 are shown hardly correlated with the mass concentrations. The elements originated from natural sources have been predominantly related to the mass concentrations while the elements from anthropogenic sources have mainly affected on the number concentrations of $PM_{10}$.

Source Apportionment Study and Chemical Composition of PM10 and PM2.5 in the Industrial Complex of Busan City, Korea (SEM-EDX 분석법에 의한 부산 S공업단지의 PM10과 PM2.5의 화학적 조성 및 발생원 추정)

  • Kim, Yong-Seog;Choi, Kum-Chan;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.26 no.11
    • /
    • pp.1297-1306
    • /
    • 2017
  • This study identified physical characteristics and aerosol particle sources of $PM_{10}$ and $PM_{2.5}$ in the industrial complex of Busan Metropolitan City, Korea. Samples of $PM_{10}$, $PM_{2.5}$ and also soil, were collected in several areas during the year of 2012 to investigate elemental composition. A URG cyclone sampler was used for collection. The samples were collected according to each experimental condition, and the analysis method of SEM-EDX was used to determine the concentration of each metallic element. The comparative analysis indicated that their mass concentration ranged from 1% to 3%. The elements in the industrial region that were above 10% were Si, Al, Fe, and Ca. Those below 5% were Na, Mg, and S. The remaining elements (1% of total mass) consisted of elements such as Ni, Co, Br and Pb. Finally, a statistical tool was applied to the elemental results to identify each source for the industrial region. From a principal components analysis (SPSS, Ver 20.0) performed to analyze the possible sources of $PM_{10}$ in the industrial region, five main factors were determined. Factor 1 (Si, Al), which accounted for 15.8% of the total variance, was mostly affected by soil and dust from manufacturing facilities nearby, Factors 2 (Cu, Ni), 3 (Zn, Pb), and 4 (Mn, Fe), which also accounted for some of variance, were mainly related to iron, non-ferrous metals, and other industrial manufacturing sources. Also, five factors determined to access possible sources of $PM_{2.5}$, Factor 1 (Na, S), accounted for 13.5% of the total variance and was affected by sea-salt particles and fuel incineration sources, and Factors 2 (Ti, Mn), 3 (Pb, Cl), 4 (K, Al) also explained significant proportions of the variance. Theses factors mean that the $PM_{2.5}$ emission sources may be considered as sources of incineration, and metals, and non-ferrous manufacturing industries.

All Solution processed BiVO4/WO3/SnO2 Heterojunction Photoanode for Enhanced Photoelectrochemical Water Splitting

  • Baek, Ji Hyun;Lee, Dong Geon;Jin, Young Un;Han, Man Hyung;Kim, Won Bin;Cho, In Sun;Jung, Hyun Suk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.417-417
    • /
    • 2016
  • Global environmental deterioration has become more serious year by year and thus scientific interests in the renewable energy as environmental technology and replacement of fossil fuels have grown exponentially. Photoelectrochemical (PEC) cell consisting of semiconductor photoelectrodes that can harvest light and use this energy directly to split water, also known as photoelectrolysis or solar water splitting, is a promising renewable energy technology to produce hydrogen for uses in the future hydrogen economy. A major advantage of PEC systems is that they involve relatively simple processes steps as compared to many other H2 production systems. Until now, a number of materials including TiO2, WO3, Fe2O3, and BiVO4 were exploited as the photoelectrode. However, the PEC performance of these single absorber materials is limited due to their large charge recombinations in bulk, interface and surface, leading low charge separation/transport efficiencies. Recently, coupling of two materials, e.g., BiVO4/WO3, Fe2O3/WO3 and CuWO4/WO3, to form a type II heterojunction has been demonstrated to be a viable means to improve the PEC performance by enhancing the charge separation and transport efficiencies. In this study, we have prepared a triple-layer heterojunction BiVO4/WO3/SnO2 photoelectrode that shows a comparable PEC performance with previously reported best-performing nanostructured BiVO4/WO3 heterojunction photoelectrode via a facile solution method. Interestingly, we found that the incorporation of SnO2 nanoparticles layer in between WO3 and FTO largely promotes electron transport and thus minimizes interfacial recombination. The impact of the SnO2 interfacial layer was investigated in detail by TEM, hall measurement and electrochemical impedance spectroscopy (EIS) techniques. In addition, our planar-structured triple-layer photoelectrode shows a relatively high transmittance due to its low thickness (~300 nm), which benefits to couple with a solar cell to form a tandem PEC device. The overall PEC performance, especially the photocurrent onset potential (Vonset), were further improved by a reactive-ion etching (RIE) surface etching and electrocatalyst (CoOx) deposition.

  • PDF

Aerosol Deposition and Its Potential Use for Bioactive Ceramic Coatings

  • Hahn, Byung-Dong;Park, Dong-Soo;Lee, Jeong-Min;Choi, Jong-Jin;Ryu, Jung-Ho;Yoon, Woon-Ha;Lee, Byoung-Kuk;Choi, Joon-Hwan;Kim, Hyoun-Ee
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.41.1-41.1
    • /
    • 2009
  • Aerosol Deposition (AD) is anovel way to fabricate bioactive ceramic coatings in biomedical implants and prostheses applications. In the present work, silicon-substituted hydroxyapatite (HA) coatings on commercially pure titanium were prepared by aerosol deposition using Si-HA powders. The incorporation of silicon in the HA lattice is known to improve the bioactivity of the HA, makingsilicon-substitute HA an attractive alternative to pure HA in biomedical applications. Si-HA powders with the chemical formula $Ca_{10}(PO_4)_6-x(SiO_4)x(OH)_2-x$, having silicon contents up to x=0.5 (1.4 wt%), were synthesized by solid-state reaction of $Ca_2P_2O_7$, $CaCO_3$, and $SiO_2$. The Si-HA powders were characterized by X-ray diffraction (XRD), X-ray fluorescence spectrometry (XRF), and Fourier transform infrared spectroscopy(FT-IR). The corresponding coatings were also analyzed by XRD, scanning electron microscopy (SEM), and electron probe microanalyzer (EPMA). The results revealed that a single-phase Si-HA was obtained without any secondary phases such as $\alpha$- or $\beta$-tricalcium phosphate (TCP) for both the powders and the coatings.The Si-HA coating was about $5\;{\mu}m$ thick, had a densemicrostructure with no cracks or pores. In addition, the proliferation and alkaline phosphatase (ALP) activity of MC3T3-E1 preosteoblast cells grown on the Si-HA coatings were significantly higher than those on the bare Ti and pure HA coating. These results revealed the stimulatory effects induced by siliconsubstitution on the cellular response to the HA coating.

  • PDF

원자로내 용융물 재배치시 용기 하부의 온도 거동

  • Kang, Kyung-Ho;Kim, Jong-Hwan;Kim, Sang-Baek;Kim, Hui-Dong;Kim, Hyun-Seop;Heo, Hun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.581-586
    • /
    • 1997
  • 중대사고시 노심의 손상에 의한 노심용융물이 원자로 용기 하부 반구로 재배치될 때 고온의 노심용융물에 의한 열적 부하로 원자로 용기의 파손을 일으키게 된다. 원자로 용기하부 반구 내에서의 노심용융물의 열적 거동 및 하부 반구에 대한 열적 부하에 대한 분석은 용융물의 성분 및 재배치 과정의 복잡성 등으로 인한 실험적 모사의 한계성 및 현상 분석의 난이함에도 불구하고 기존 원자로의 중대사고에 대한 안전 여유도의 제고와 이에 따른 노내외 사고 관리 전략의 수립을 위하여 연구의 필요성이 제기된다. 본 연구에서는 노심용융물 냉각연구(SONATA-IV)의 예비 실험으로 노심용융물의 상사물로 $Al_2$O$_3$/Fe Thermite 용융물을 이용하여 실제 원자로 용기 하부 반구를 1/8 로 선형 축소한 반구형 실험 용기로 주입하는 실험을 수행하였다. 아울러 원자로 용기 하부 반구로 재배치된 노심용융물에 의한 열적, 기계적 부하에 대한 분석을 수행하기 개발된 유한 요소 프로그램인 CALF (Computer Analysis for Lower Head Failure ) 코드를 이용한 하부 반구의 열적 거동에 대한 해석 결과를 정리하였다. 용융물 주입 실험 결과 용융물 주입과 동시에 하부 반구에 직경 5cm 크기의 하부 반구 파손이 발생하였다. 이는 고온 용융물에 의한 제트류(Jet Impingement)의 효과로 생각된다 동일한 조건에서 CALF 코드로 하부 반구의 열적 거동을 분석하였는데, 실험과는 달리 하부 반구의 파손이 발생하지 않았다 이같은 해석 결과는 용융물의 제트류 효과가 존재하지 않는다면 고온의 용융물이 하부 반구 내로 재배치되더라도 하부 반구의 파손이 발생하지 않는다는 것을 보여준다.>$_3$ 흡착제 제조시 TiO$_2$ 함량에 따른 Co$^{2+}$ 흡착량과 25$0^{\circ}C$의 고온에서 ZrO$_2$$Al_2$O$_3$의 표면에 생성된 코발트 화합물을 XPS와 EPMA로 부터 확인하였다.인을 명시적으로 설명할 수 있다. 둘째, 오류의 시발점을 정확히 포착하여 동기가 분명한 수정대책을 강구할 수 있다. 셋째, 음운 과 정의 분석 모델은 새로운 언어 학습시에 관련된 언어 상호간의 구조적 마찰을 설명해 줄 수 있다. 넷째, 불규칙적이며 종잡기 힘들고 단편적인 것으로만 보이던 중간언어도 일정한 체계 속에서 변화한다는 사실을 알 수 있다. 다섯째, 종전의 오류 분석에서는 지나치게 모국어의 영향만 강조하고 다른 요인들에 대해서는 다분히 추상적인 언급으로 끝났지만 이 분석을 통 해서 배경어, 목표어, 특히 중간규칙의 역할이 괄목할 만한 것임을 가시적으로 관찰할 수 있 다. 이와 같은 오류분석 방법은 학습자의 모국어 및 관련 외국어의 음운규칙만 알면 어느 학습대상 외국어에라도 적용할 수 있는 보편성을 지니는 것으로 사료된다.없다. 그렇다면 겹의문사를 [-wh]의리를 지 닌 의문사의 병렬로 분석할 수 없다. 예를 들어 누구누구를 [주구-이-ν가] [누구누구-이- ν가]로부터 생성되었다고 볼 수 없다. 그러므로 [-wh] 겹의문사는 복수 의미를 지닐 수 없 다. 그러면 단수 의미는 어떻게 생성되는가\ulcorner 본 논문에서는 표면적 형태에도 불구하고 [-wh]의미의 겹의문사는 병렬적 관계의 합성어가 아니라 내부구조를 지니지 않은 단순한 단어(minim

  • PDF

Prevalence Rate of Low_Back Pain and Its Related Factors in Physical Therapists (물리치료사의 요통 유병률과 관련요인)

  • Jung Soo-yeoun;Shin Hyung-soo;Park Jae-yong
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.2
    • /
    • pp.22-37
    • /
    • 2005
  • This study was performed to investigate LBP(low-back pain) prevalence rate and its related factors inphysical therapists. A self-administered questionnaire survey was conducted to 522 physical therapists in Daegu and Gyeongsangbuk. The LBP prevalence rate for recent 6 months was $61.7\%$. According to age, the prevalence rate was highest in the group aged 24 or less for both male and female physical therapistis. For male physical therapists , it was higher in smokers and drivers, but for female ones, it was not in a significant relationship with smoking and driving. According to work experience, the prevalence rates of those who had been working for less than one year were the highest, and those who had been working at hospitals and clinics were $69.1\%$, significantly high. According to therapy techinque, the prevalence rate related ti PNF was $71.6\%$, the highest and to occupational therapy was $34.3\%$, the lowest. According to working environment for six months, in both male and female physical therapists. LBP prevalence rate was in a statistically significant relationship with work hours during the day, night and weekend duties, repetitive works, motions that bend or twist the waist, the number of patients per day, the number of time to help patients per day, the number of time to carry medical equipment per day and the length of time to work standing. The rate was also higher when physical therapists fekt nire stress from their work. According to the result of multiple logistic regression analysis, male was in a significant relationship with work experience and motions that bend or twist the waist and female was in a significant relationship with work hours during the night and weekend duties, the number of time to help patients per day, motions that bena or twist the waist, actions taken to protect the waist. As for the developmental pattem of LBP in the group of physical therapists with LBP for six moths, $15.7\%$ of them had LBP for first time, $42.3\%$ had recurred LBP, and $42.0\%$ had chronic LBP. As for the causes of LBP, $51.7\%$ said that it was because they worked in the same posture for a long time, and as for how to treat LBP, 48.8% said that they treated themselvs or got help from their co-wokers. The results presented above suggest that physical therapists are exposed to high risk of LBP caused form occupational activities. Therefire, it is necessary to improve working environment to reduce the occurrence of LBP and to develop education programs for preventing the occurrence and recurrence of LBP.

  • PDF