• Title/Summary/Keyword: CoM(Center of Mass)

Search Result 130, Processing Time 0.025 seconds

Uncontrolled Manifold Analysis of Whole Body CoM of the Elderly: The Effect of Training using the Core Exercise Equipment

  • Park, Da Won;Koh, Kyung;Park, Yang Sun;Shim, Jae Kun
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.4
    • /
    • pp.213-218
    • /
    • 2018
  • Objective: The purpose of this study was to examine the effect of the core muscle strength enhancement of the elderly on 8 weeks training using the core exercise equipment for the elderly on the ability to control the whole-body center of mass in posture stabilization. Method: 16 females (10 exercise group, 6 control group) participated in this study. Exercise group took part in the core strength training program for 8 weeks with total of 16 repetitions (2 repetitions per week) using a training device. External perturbation during standing as pulling force applied at the pelvic level in the anterior direction was provided to the subject. In a UCM model, the controller selects within the space of elemental variables a subspace (a manifold, UCM) corresponding to a value of a performance variable that needs to be stabilized. In the present study, we were interested in how movements of the individual segment center of mass (elemental variables) affect the whole-body center of mass (the performance variable) during balance control. Results: At the variance of task-irrelevant space, there was significant $test^*$ group interactions ($F_{1,16}=7.482$, p<.05). However, there were no significant main effect of the test ($F_{1,16}=.899$, p>.05) and group ($F_{1,16}=1.039$, p>.05). At the variance of task-relevant space, there was significant $test^*$ group interactions ($F_{1,16}=7.382$, p<.05). However, there were no significant main effect of the test ($F_{1,16}=.754$, p>.05) and group ($F_{1,16}=1.106$, p>.05). Conclusion: The results of this study showed that the 8 weeks training through the core training equipment for the elderly showed a significant decrease in the $Vcm_{TIR}$ and $Vcm_{TR}$. This result indicates that the core strength training affects the trunk stiffness control strategy to maintain balance in the standing position by minimizing total variability of individual segment CMs.

The Stability Test of New Carbapenem DWP20418 and Partial Purification and Characterization of Renal Dehydropeptidase-I (돼지 신장으로부터 디펩티다제의 부분정제 및 그에 대한 신규 카바페넴계 항생물질 DWP20418의 안정성 평가)

  • Kim, Ji-Yeon;Park, Nam-Jun;Yu, Young-Hyo;Park, Myung-Hwan
    • YAKHAK HOEJI
    • /
    • v.41 no.5
    • /
    • pp.615-621
    • /
    • 1997
  • Dehydropeptidase-I (DHP-I) was solubilized from porcine kidney by treatment with n-butanol and partially purified 19.25 fold by $(NH_4)_2SO_4$ precipitation, DEAE-Sepharose CL-6B ion exchange chromatography and Sephacryl S-300 HR chromatography with an overall yield of 19.16. DHP-I showed its optimal activity at pH 7.5 and 25$^{\circ}C$. Its activity was stable under neutral and alkaline conditions, but was disappeared under acidic condition. And DHP-I was heat-labile and its activity remained at 45$^{\circ}C$ for 3hrs. The enzyme was not inhibited by dicationic ions, while its activity was increased by $Co^{2+}$(1mM) and $Zn^{2+}$ (0.1mM). The enzyme was inhibited by EDTA and N-ethylmaleimide. The relative molecular mass of DHP-I was estimated to be approximately 100kDa by gel filtration chromatography. The $K_m$ value of DHP-I for glycyldehydrophenylalanine (GDHP) was 1.98mM. DWP20418 [(1R, 5S, 6S)-6-[1-(R)-Hydroxyethyl]-1-methyl-2-[(2S, 4S)-2-(piperazinylcarbonyl)-1-(R)-hydroxyethyl)pyrrolidine-4-thio]carbapen-2-em-3-carboxylic acid], compared with meropenem (MEPM), was rather easily hydrolized by DHP-I, while it was four times more resistant than imipenem (IPM) to DHP-I.

  • PDF

Recent Development of Optically Compensated Bend (OCB) Mode TFT-LCD

  • Wakemoto, Hirofumi;Nishiyama, Kazuhiro;Nakao, Kenji;Takimoto, Akio
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.562-566
    • /
    • 2005
  • Toshiba Matsushita Display Technology (TMD) has firstly succeeded in mass production of OCB (Optically Compensated Bend) mode liquid crystal display panels which have excellent moving picture quality almost the same as CRT. We have newly developed 32 -inch diagonal HD ($1366{\times}768\;pixels$) panels using OCB mode and low temperature p-Si TFT (LTPS) array substrates. High performance of brightness of $600cd/m^2$ and contrast ratio of 600 : 1 was obtained by using pseudo-impulse driving method to insert a black period between continuous two frames, and also by using blinking backlight method. Furthermore, moving picture response time (MPRT) 6.5ms has been obtained by optimization of black insert driving and backlight blinking, without the great sacrifices of contrast ratio and luminance.

  • PDF

A Consideration on Segregation Process of Dopant at WC/Co and WC/WC Interfaces in VC Doped WC-Co Submicro-grained Hardmetal

  • Kawakami, Masaru;Terada, Osamu;Hayashi, Koji
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.334-335
    • /
    • 2006
  • WC/WC interface in VC mono-doped WC-10mass%Co submicro-grained hardmetals of $0.5\;{\mu}m$ was investigated together with WC/Co interface by using HRTEM and XMA. The thickness of V-rich layer and the analytical value of V at WC/WC interface were almost the same as those at WC/Co interfaces. These results, etc., suggested that the V-rich layers at both interfaces were not generated by an equilibrium segregation mechanism in the sintering stage, but generated by a preferential precipitation mechanism during the solidification of Co liquid phase in the cooling stage. Based on this suggestion, we succeeded in developing a nano-grained hardmetal with 100 nm $(0.1\;{\mu}m)$.

  • PDF

MOLECULAR CLOUDS WITH PECULIAR VELOCITY IN THE OUTER LOCAL ARM

  • Kang, Mi-Ju;Lee, Young-Ung
    • Journal of The Korean Astronomical Society
    • /
    • v.39 no.4
    • /
    • pp.107-114
    • /
    • 2006
  • We conducted an analysis of a selected region from the FCRAO $^{12}CO$ Outer Galaxy Survey. The selected region is located between galactic longitude $117^{\circ}$ and $124^{\circ}$ with the velocity of -23 km $s^{-1}. Molecular clouds in this region show a peculiar velocity field, protruding from the Local Arm population. The selected region is divided into 7 clouds by spatial location. Though we were not able to identify the direct driving source for peculiar velocity of our target region, we find that there are several internal YSOs or star forming activities; there are many associated sources like an outflows, a high-mass protostellar candidate and $H_2O$ maser sources. We attribute the driving energy source to older generation of episodic star formation. Masses of main clouds(cloud 1-4) estimated using a conversion factor from $^{12}CO$ luminosity are larger than $10^4M_{\odot}$. Other components have a small mass as about $10^3M_{\odot}$. Among main clouds, cloud 2 and 4 seem to be marginally gravitational bound systems as their ratio of $M_{CO}$ to $M_{VIR}$ is about $2{\sim}3$, and the internal velocity dispersion is larger than the centroid velocity dispersion. Total mass estimated using a conversion factor from $^{12}CO$ luminosity is $7.9{\times}10^4M_{\odot}$.

Determination of Tiapride in Human Plasma Using Hydrophilic Interaction Liquid Chromatography-Tandem Mass Spectrometry

  • Moon, Ya;Paek, In-Bok;Kim, Hui-Hyun;Ji, Hye-Young;Lee, Hye-Won;Park, Hyoung-Geun;Lee, Hye-Suk
    • Archives of Pharmacal Research
    • /
    • v.27 no.9
    • /
    • pp.901-905
    • /
    • 2004
  • A rapid, sensitive and selective hydrophilic interaction liquid chromatography-tandem mass spectrometric(HILIC-MS/MS) method for the determination of tiapride in human plasma was developed. Tiapride and internal standard, metoclopramide were extracted from human plasma with dichloromethane at basic pH and analyzed on an Atlantis HILIC silica column with the mobile phase of acetonitrile-ammonium formate (190 mM, pH 3.0) (94:6, v/v). The ana-Iytes were detected using an electrospray ionization tandem mass spectrometry in the multi-ple-reaction-monitoring mode. The standard curve was linear (r=0.999) over the concentration range of 1.00-200 ng/mL. The coefficient of variation and relative error for intra- and inter-assay at three QC levels were 6.4∼8.8% and -2.0∼3.6%, respectively. The recoveries of tiapride ranged from 96.3 to 97.4%, with that of metoclopramide (internal standard) being 94.2%. The lower limit of quantification for tiapride was 1.00 ng/mL using 1 00 $\mu$L of plasma sample.

Performance of fouled NF membrane as used for textile dyeing wastewater

  • Abdel-Fatah, Mona A.;Khater, E.M.H.;Hafez, A.I.;Shaaban, A.F.
    • Membrane and Water Treatment
    • /
    • v.11 no.2
    • /
    • pp.111-121
    • /
    • 2020
  • The fouling of Nanofiltration membrane (NF) was examined using wastewater containing reactive black dye RB5 of 1500 Pt/Co color concentrations with 16890 mg/l TDS collected from El-alamia Company for Dying and Weaving in Egypt. The NF-unit was operated at constant pressure of 10 bars, temperature of 25℃, and flowrate of 420 L/min. SEM, EDX, and FTIR were used for fouling characterization. Using the ROIFA-4 program, the total inorganic fouling load was 1.07 mM/kg present as 49.3% Carbonates, 10.1% Sulfates, 37.2% Silicates, 37.2% Phosphates, and 0.93% Iron oxides. The permeate flux, recovery, salt rejection and mass transfer coefficients of the dye molecules were reduced significantly after fouling. The results clearly demonstrate that the fouling had detrimental effect on membrane performance in dye removal, as indicated by a sharp decrease in permeate flux and dye recovery 68%. The dye mass transfer coefficient was dropped dramatically by 34%, and the salt permeability increased by 14%. In this study, all the properties of the membrane used and the fouling that caused its poor condition are identified. Another study was conducted to regeneration fouled membrane again by chemical methods in another article (Abdel-Fatah et al. 2017).

Comparison of Newton's and Euler's Algorithm in a Compound Pendulum (복합진자 모형의 뉴튼.오일러 알고리즘 비교)

  • Hah, Chong-Ku
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.1-7
    • /
    • 2006
  • The Primary type of swinging motion in human movement is that which is characteristic of a pendulum. The two types of pendulums are identified as simple and compound. A simple pendulum consist of a small body suspended by a relatively long cord. Its total mass is contained within the bob. The cord is not considered to have mass. A compound pendulum, on the other hand, is any pendulum such as the human body swinging by hands from a horizontal bar. Therefore a compound pendulum depicts important motions that are harmonic, periodic, and oscillatory. In this paper one discusses and compares two algorithms of Newton's method(F = m a) and Euler's method (M = $I{\times}{\alpha}$) in compound pendulum. Through exercise model such as human body with weight(m = 50 kg), body length(L = 1.5m), and center of gravity ($L_c$ = 0.4119L) from proximal end swinging by hands from a horizontal bar, one finds kinematic variables(angle displacement / velocity / acceleration), and simulates kinematic variables by changing body lengths and body mass. BSP by Clauser et al.(1969) & Chandler et al.(1975) is used to find moment of inertia of the compound pendulum. The radius of gyration about center of gravity (CoG) is $k_c\;=\;K_c{\times}L$ (단, k= radius of gyration, K= radius of gyration /segment length), and then moment of inertia about center of gravity(CoG) becomes $I_c\;=\;m\;k_c^2$. Finally, moment of inertia about Z-axis by parallel theorem becomes $I_o\;=\;I_c\;+\;m\;k^2$. The two-order ordinary differential equations of models are solved by ND function of numeric analysis method in Mathematica5.1. The results are as follows; First, The complexity of Newton's method is much more complex than that of Euler's method Second, one could be find kinematic variables according to changing body lengths(L = 1.3 / 1.7 m) and periods are increased by body length increment(L = 1.3 / 1.5 / 1.7 m). Third, one could be find that periods are not changing by means of changing mass(m = 50 / 55 / 60 kg). Conclusively, one is intended to meditate the possibility of applying a compound pendulum to sports(balling, golf, gymnastics and so on) necessary swinging motions. Further improvements to the study could be to apply Euler's method to real motions and one would be able to develop the simulator.

Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

  • Hur, Yeoun;Tae, Sookil;Koh, Yun-Joo;Hong, Sung-Hyun;Yoon, Young Ho;Jang, Haejong;Kim, Sooji;Kim, Kyeong Ho;Kang, Seung Woo;Lee, Youngshin;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.42-48
    • /
    • 2014
  • A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column ($150mm{\times}2.0mm$, $4{\mu}m$) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/v) at a flow rate of $450{\mu}L$/min. Porphyrins and the internal standard (IS), coproporphyrin I-$^{15}N_4$, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.

Kinesiology Based Human-like Walking Pattern Design for a Bipedal Robot (인체운동학에 기반한 이족로봇의 인간형 걸음새 설계)

  • Park, Jin-Hee;Kwon, Sang-Joo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.7
    • /
    • pp.659-667
    • /
    • 2011
  • The study of bipedal robot is towards similar shape and function with human. In this paper, we propose a human-like walking pattern compatible to the flexible foot with toe and heel structure. The new walking pattern for a bipedal robot consists of ZMP, center of mass (CoM), and ankle trajectory and is drawn by considering human kinesiology. First, the ZMP trajectory moves forward without stopping at a point even in the single support phase. The corresponding CoM trajectory to the ZMP one is derived by solving differential equations. As well, a CoM trajectory for the vertical axis is added by following the idea of human motion. The ankle trajectory closely mimics the rotational motion of human ankles during taking off and landing on the ground. The advantages of the proposed walking pattern are demonstrated by showing improved stability, decreased ankle torque, and the longer step length capability. Specifically, it is interesting to know that the vertical CoM motion is able to compensate for the initial transient response.