• 제목/요약/키워드: Co-inserted

Search Result 252, Processing Time 0.03 seconds

Local tissue effects of various barrier membranes in a rat subcutaneous model

  • Naenni, Nadja;Lim, Hyun-Chang;Strauss, Franz-Josef;Jung, Ronald E.;Hammerle, Christoph H.F.;Thoma, Daniel S.
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.5
    • /
    • pp.327-339
    • /
    • 2020
  • Purpose: The purpose of this study was to examine the local tissue reactions associated with 3 different poly(lactic-co-glycolic acid) (PLGA) prototype membranes and to compare them to the reactions associated with commercially available resorbable membranes in rats. Methods: Seven different membranes-3 synthetic PLGA prototypes (T1, T2, and T3) and 4 commercially available membranes (a PLGA membrane, a poly[lactic acid] membrane, a native collagen membrane, and a cross-linked collagen membrane)-were randomly inserted into 6 unconnected subcutaneous pouches in the backs of 42 rats. The animals were sacrificed at 4, 13, and 26 weeks. Descriptive histologic and histomorphometric assessments were performed to evaluate membrane degradation, visibility, tissue integration, tissue ingrowth, neovascularization, encapsulation, and inflammation. Means and standard deviations were calculated. Results: The histological analysis revealed complete integration and tissue ingrowth of PLGA prototype T1 at 26 weeks. In contrast, the T2 and T3 prototypes displayed slight to moderate integration and tissue ingrowth regardless of time point. The degradation patterns of the 3 synthetic prototypes were similar at 4 and 13 weeks, but differed at 26 weeks. T1 showed marked degradation at 26 weeks, whereas T2 and T3 displayed moderate degradation. Inflammatory cells were present in all 3 prototype membranes at all time points, and these membranes did not meaningfully differ from commercially available membranes with regard to the extent of inflammatory cell infiltration. Conclusions: The 3 PLGA prototypes, particularly T1, induced favorable tissue integration, exhibited a similar degradation rate to native collagen membranes, and elicited a similar inflammatory response to commercially available non-cross-linked resorbable membranes. The intensity of inflammation associated with degradable dental membranes appears to relate to their degradation kinetics, irrespective of their material composition.

Results of immediate loading for implant restoration in partially edentulous patients: a 6-month preliminary prospective study using SinusQuickTM EB implant system

  • Kim, Jong-Hwa;Kim, Young-Kyun;Yi, Yang-Jin;Yun, Pil-Young;Lee, Hyo-Jung;Kim, Myung-Jin;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.3
    • /
    • pp.136-139
    • /
    • 2009
  • STATEMENT OF PROBLEM. Many dental clinicians are concerned about immediate loading of inserted implants. However, there have been few clinical studies surveying the success rates of immediate loading, based on Korean implant systems. PURPOSE. The aim of this study was to evaluate the outcome of immediate functional loading of the implant ($SinusQuick^{TM}$EB, Neobiotech Co., Seoul, Korea) in partially edentulous maxilla or mandible. MATERIAL AND METHODS. Total 15 implants were placed. Within 2 weeks after implant insertion, provisional implant-supported fixed partial dentures were delivered to the patients. Quantitatively, marginal bone loss was measured at the time of immediate loading, after 3-months of continued loading and at the last follow-up. The mean follow-up period was 4.8 months. RESULTS. Mean marginal bone loss from implant surgery to early loading, 3-months follow-up and last follow-up was $0.03\pm0.07$ mm, $0.16\pm0.17$ mm and $0.29\pm0.19$ mm. No implant failed up to 6 months after insertion, resulting in a 100% survival rate. CONCLUSION. Immediate loading exhibited high success rate in partial edentulism for up to 6 months. Well-controlled long term clinical studies with large sample size are necessary to confirm this finding.

Design of Broadband Spiral Antenna for Non-Linear Junction Detector (비선형 소자 탐지용 광대역 스파이럴 안테나의 설계)

  • Kim, Tae-Geun;Min, Kyeong-Sik;Lee, Kwang-Kun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.1
    • /
    • pp.81-88
    • /
    • 2011
  • This paper presents a design of spiral antenna with broad bandwidth for non-linear junction detector(NLJD). An elliptical patch as radiating element located on center position of radiating surface, as well as the spiral elements on radiating surface was designed for broad bandwidth of spiral antenna. An antenna ground structure generating the multi resonance by spiral slit inserted on ground surface was also proposed. In order to realize high directivity and high gain of the proposed antenna, the cavity wall made of Fr4-epoxy and the metal cap were considered in design. As a result, the calculated gain of antenna with metal cap was improved about 3 dB with comparison of antenna without metal cap and the measured main beam directivity toward -z axis direction agreed well with calculation result. The measured axial ratio satisfied the circular polarization within -z axis ${\pm}45^{\circ}$ at design frequency bands and showed reasonable agreement with prediction.

Cloning of the dextranase gene(lsd11) from Lipomyces starkeyi and its expression in Pichia pastoris.

  • Park, Ji-Young;Kang, Hee-Kyoung;Jin, Xing-Ji;Ahn, Joon-Seob;Kim, Seung-Heuk;Kim, Do-Won;Kim, Do-Man
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.644-648
    • /
    • 2005
  • Dextranase (${\alpha}$-1,6-D-glucan-6-glucanogydrolase:E.C. 3.2.1.11) catalyzes the hydrolysis of ${\alpha}$-(1.6) linkages of dextran. A lsd1 gene encoding an extracellular dextranase was isolated from the genomic DNA of L. starkeyi. The lsd11 gene is a synthetic dextranase (lsd1) after codon optimization for gene expression with Pichia pastoris system. A open reading frame of lsd11 gene was 1827 bp and it was inserted into the pPIC3.5K expression vector. The plasmid linearized by Sac I was integrated into the 5'AOX region of the chromosomal DNA of P. pastoris. The lsd11 gene fragment encoding a mature protein of 608 amino acids with a predicted molecular weight of 70 kDa, was expressed in the methylotrophic yeast P. pastoris by controling the alcohol oxidase-1 (AOX1) promoter. The recombinant lds11 was optimized by using the shake-flask expression and upscaled using fermentation technology. More than 9.8 mg/L of active dextranase was obtained after induction by methanol. The optimum pH of LSD11 was found to be 5.5 and the optimum temperature $28^{\circ}C$.

  • PDF

A study on the fracture strength of collarless metal-ceramic fixed partial dentures

  • Yoon, Jong-Wook;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.4
    • /
    • pp.134-141
    • /
    • 2010
  • PURPOSE. The objective of this study was to evaluate fracture strength of collarless metal-ceramic FPDs according to their metal coping designs. MATERIALS AND METHODS. Four different facial margin design groups were investigated. Group A was a coping with a thin facial metal collar, group B was a collarless coping with its facial metal to the shoulder, group C was a collarless coping with its facial metal 1 mm short of the shoulder, and group D was a collarless coping with its facial metal 2 mm short of the shoulder. Fifteen 3-unit collarless metal-ceramic FPDs were fabricated in each group. Finished FPDs were cemented to PBT (Polybutylene terephthalate) dies with resin cement. The fracture strength test was carried out using universal testing machine (Instron 4465, Instron Co., Norwood MA, USA) at a cross head speed of 0.5 mm/min. Aluminum foil folded to about 1 mm of thickness was inserted between the plunger tip and the incisal edge of the pontic. Vertical load was applied until catastrophic porcelain fracture occurred. RESULTS. The greater the bulk of unsupported facial shoulder porcelain was, the lower the fracture strength became. However, there were no significant differences between experimental groups (P > .05). CONCLUSION. All groups of collarless metal-ceramic FPDs had higher fracture strength than maximum incisive biting force. Modified collarless metal-ceramic FPD can be an alternative to all-ceramic FPDs in clinical situations.

Subsurface Antenna for Remote Management of Underground Facility (지하 매설물 원격 관리를 위한 지표면 매입형 안테나)

  • Park, Dong-Kook;Cho, Ik-Hyun;Seo, Hong-Eun;Yun, Na-Ra;Hong, Che-Sup
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.10
    • /
    • pp.1150-1156
    • /
    • 2007
  • In this paper, two novel subsurface antennas for remote management of underground facilities using PCS and cellular wireless network are proposed. The proposed subsurface antenna is a dual band circular patch which is inserted and molded for the protection of the antenna into a metal such as a manhole cover. The antenna is designed considering the resonant frequency shift of the antenna due to the insertion and molding. The measured return loss and receiving power of the fabricated antenna comparison with a dipole shows that two proposed subsurface antenna can be used for remote management of underground facilities using PCS and cellular systems.

Analysis of Telomerase Activity by HPV E6/E7 Expression in SW13

  • Kim, Young-Kwon;Park, Yuk-Pheel
    • Biomedical Science Letters
    • /
    • v.12 no.4
    • /
    • pp.399-403
    • /
    • 2006
  • Cervical cancer is one of the most prevalent cancers developed in women worldwide, and human papillomavirus (HPV) type 16 is the most common agent linked to human cerivical carcinoma. Viral oncogenes E6 and E7 are selectively ratined and expressed in carcinoma cells infected with human papillomavirus type 16 and cooperated with each other in immortalization and transformation of primary keratinocytes. Because of HPV oncogenesis mechanism was not completely solved, the more studies be required thoroughly. In the present study, to investigate the telomere independent role of telomerase in HPV oncogenesis, we constructed the E6 mutant, E7, E6/E7 and hTERT over-expressed stable cells with a telomerase negative cell line, SW13. Expressions of Inserted genes were measured by RT-PCR. E6, E7 and hTERT genes were well expressed in each cell lines comparing with the control groups. By analyzing the cell morphology under the microscope, hTERT clone size was a more smaller than the mock control but oncogene expressed clones were slightly lengthened the marginal region. In addition, hTERT cells has also, a tendency of brief dividing time compared to the mock control. To determine whether telomerase activity associated with a HPV oncogenesis by oncoprotein expression, we performed the PCR based TRAP assay and Northern blot analysis. In TRAP assay data, telomerase activities in hTERT and oncogene clones were more increased than the mock control. In addition, SW13/ E6/E7 cells appeared a extremely increased activity than any other clones. Induced TERT mRNA by E6/E7 wasn't, however, detected in Northern blotting. In conclusion, these findings suggest that telomerase activity closely associated the HPV oncogenesis and E6/E7 co-expression is a most important factor of telomerase activity.

  • PDF

Red Emission Properties of Organic EL Having Hole Blocking Layer (정공블록킹층을 설치한 유기 EL의 적색발광특성)

  • Kim, Hyeong-Gweon;Lee, Eun-Hak
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.6
    • /
    • pp.17-23
    • /
    • 2000
  • In this study, we prepared red organic light-emitting-diode(OLED) with a fluorescent dye(Sq)-doped and inserted between emission and cathode layer 1,3-bis(5-p-t-butylphenyl)-1,3,4-oxadiazol-2-yl)benzene (OXD7) or/and tris(8-hydroxyquinoline) aluminum ($Alq_3$) layers for increasing electroluminescent(EL) efficiency. This inserting effect has been observed and EL mechanism characteristics have been examined. The hole transfer layer is a N,N'-diphenyl-N,N'-bis-(3-methyl phenyl)-1,1'-diphenyl-4,4'-diamine (TPD), and the host and guest materials of emission layer is $Alq_3$ and bis[1-methyl-3,3'-dimethyl-2-indorindiylmethyl] squaraine (Sq), respectively. For the inserting of $Alq_3$, emission efficiency increased. But we can not obtained highly pure red emission owing to the emission of inserting $Alq_3$ layer. The inserting of OXD7 makes hole block and accumulate. Because of increasing recombination probability of electron and hole, highly pure red color can be held. Simultaneously brightness characteristics and emission efficiency could improve.

  • PDF

Design of Wedge in the Electro-Mechanical Brakes for Commercial Vehicles to Boost Braking Friction Forces (브레이크 마찰력 증가를 위한 상용차용 전기-기계식 브레이크의 쐐기 설계)

  • Lee, Sang Min;Park, Jeonghun;Nam, Kanghyun;Yoo, Chang-Hee;Park, Sang-Shin
    • Tribology and Lubricants
    • /
    • v.34 no.2
    • /
    • pp.55-59
    • /
    • 2018
  • This paper proposes a new type of electro-mechanical wedge brake for commercial vehicles. The brake operates on a novel mechanism for self-boosting braking friction forces using eccentric shafts, and involves wedges that are inserted between the rampbridge and traverse; this self-boosting mechanism is explained herein. A dynamic analysis using ADAMS was conducted, and the findings are reported. The constraint and contact conditions are explained to verify the precision of the dynamic analysis. The dynamic analysis shows that in the proposed mechanism, the self-boosting effect occurs as desired. However, it is also noted that the system has a limitation in terms of the production of unlimited braking forces that can jam the roller inside the wedges. After demonstrating the self-boosting effect, dynamic analyses are performed for several values of the wedge angles and friction coefficients between the brake pads and disks. Conventionally, a lower wedge angle has been suggested owing to its provision of a larger clamping force for given friction coefficients. However, it is noted that lower wedge angles can lead to a higher probability of occurrence of undesirable high braking forces, which can jam the roller into the wedge; thus, a larger wedge angle is preferable for avoiding the undesirable jamming phenomena. These analysis results are presented and discussed herein.

Comparison of removal torques between laser-treated and SLA-treated implant surfaces in rabbit tibiae

  • Kang, Nam-Seok;Li, Lin-Jie;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.302-308
    • /
    • 2014
  • PURPOSE. The purpose of this study was to compare removal torques and surface topography between laser treated and sandblasted, large-grit, acid-etched (SLA) treated implants. MATERIALS AND METHODS. Laser-treated implants (experimental group) and SLA-treated implants (control group) 8 mm in length and 3.4 mm in diameter were inserted into both sides of the tibiae of 12 rabbits. Surface analysis was accomplished using a field emission scanning electron microscope (FE-SEM; Hitachi S-4800; Japan) under ${\times}25$, ${\times}150$ and ${\times}1,000$ magnification. Surface components were analyzed using energy dispersive spectroscopy (EDS). Rabbits were sacrificed after a 6-week healing period. The removal torque was measured using the MGT-12 digital torque meter (Mark-10 Co., Copiague, NY, USA). RESULTS. In the experimental group, the surface analysis showed uniform porous structures under ${\times}25$, ${\times}150$ and ${\times}1,000$ magnification. Pore sizes in the experimental group were 20-40 mm and consisted of numerous small pores, whereas pore sizes in the control group were 0.5-2.0 mm. EDS analysis showed no significant difference between the two groups. The mean removal torque in the laser-treated and the SLA-treated implant groups were 79.4 Ncm (SD = 20.4; range 34.6-104.3 Ncm) and 52.7 Ncm (SD = 17.2; range 18.7-73.8 Ncm), respectively. The removal torque in the laser-treated surface implant group was significantly higher than that in the control group (P=.004). CONCLUSION. In this study, removal torque values were significantly higher for laser-treated surface implants than for SLA-treated surface implants.