• Title/Summary/Keyword: Co-frequency detection

Search Result 115, Processing Time 0.033 seconds

Residue Levels of Organochlorine Pesticides on Paddy Field Soils in the Chungnam Area (충남지역(忠南地域) 논토양중 유기염소계(有機鹽素系) 농약(農藥)의 잔류수준(殘留水準))

  • Choi, Jong-Woo;Lee, Kyu-Seung;Lee, Jung-Kil;Noh, Kil-Bong
    • Korean Journal of Environmental Agriculture
    • /
    • v.6 no.2
    • /
    • pp.12-21
    • /
    • 1987
  • Residues of some organo-chlorine pesticides on 108 solis collected from 5 sites of Chungnam avea during March 20-April 6, 1986 were investigated. 12 different kinds of Chemical components were detected showing the highest detection frequency with P.P'-DDE(67.6%) and the lowest with Heptachlor(1.8%). 4 different chemicals, ${\alpha}-BHC$, ${\gamma}-chlordane$, P.P'-DDD and P.P'-DDD and P.P'-DDE showed their average contents in the soils of 0.001 ppm and 0.005ppm for ${\beta}-BHC$, respectively. On the other hand, ${\alpha}-BHC$, ${\gamma}-chlordane$, P.P'-DDT. O.P'-DDT and P.P'-DDD showed 0.002ppm for their average contents of residues, respectively.

  • PDF

TEMPORAL VARIATIONS OF THE GLOBAL SEISMIC PARAMETERS OF HD 49933 OVER A MAGNETIC CYCLE

  • Kim, Ki-Beom;Chang, Heon-Young
    • Journal of The Korean Astronomical Society
    • /
    • v.54 no.4
    • /
    • pp.129-137
    • /
    • 2021
  • It has been established that the acoustic mode parameters of the Sun and Sun-like stars vary over activity cycles. Since the observed variations are not consistent with an activity-related origin, even Sun-like stars showing out-of-phase changes of mode frequencies and amplitudes need to be carefully studied using other observational quantities. In order to test whether the presumed relations between the global seismic parameters are a signature of the stellar activity cycle, we analyze the photometric light curve of HD 49933 for which the first direct detection of an asteroseismic signature for activity-induced variations in a Sun-like star was made, using observations by the CoRoT space telescope. We find that the amplitude of the envelope significantly anti-correlates with both the maximum frequency of the envelope and the width of the envelope unless superflare-like events completely contaminate the light curve. However, even though the photometric proxy for stellar magnetic activity appears to show relations with the global asteroseismic parameters, they are statistically insignificant. Therefore, we conclude that the global asteroseismic parameters can be utilized in cross-checking asteroseismic detections of activity-related variations in Sun-like stars, and that it is probably less secure and effective to construct a photometric magnetic activity proxy to indirectly correlate the global asteroseismic parameters. Finally, we seismically estimate the mass of HD 49933 based on our determination of the large separation of HD 49933 with evolutionary tracks computed by the MESA code and find a value of about 1.2M and a sub-solar metallicity of Z = 0.008, which agrees with the current consensus and with asteroseismic and non-asteroseismic data.

Feasibility Study of a Verification Tool for the Treatment of Cervical Intraepithelial Neoplasia Using Relative Electrical Property Change Before and After Laser Irradiation (레이저 조사 전후 자궁경부조직의 상대적 전기물성 스펙트럼 변화를 이용한 자궁경부 이형성증 치료검증도구의 가능성 평가)

  • Jun Beom, Heo;Tingting, Zhang;Tong In, Oh;Dong Choon, Park
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.409-416
    • /
    • 2022
  • Since the detection of cervical intraepithelial neoplasia (CIN) is increasing due to regular cervical cancer screening, there is a high demand for simpler tools to diagnose and treat CIN in the clinic. In this study, we proposed an electric property of cervical tissue to verify treatment using a laser. At first, we observed the depth and width of ablated cervical tissues for 29 samples according to four different pulse energy of the fractional CO2 laser to find enough pulse energy to reach the basement layer for initiated CIN. And then, the relative frequency differences in impedance spectrum before and after laser irradiation for ten non-CIN samples were collected using bioimpedance spectroscopy with a multi-electrode probe. As a result, the laser ablated the cervical tissues with a depth of more than 300 ㎛ at 100 mJ pulse energy. Also, we confirmed that the relative changes of electrical property for cervical tissue increased as the pulse energy of laser output increased, and the variation between samples decreased. Since the relative change in electrical properties of cervical tissue can be easily and quickly measured, the proposed technique paves the way for further verification and follow-up study of laser treatment for CIN.

Development of Power Supply for Small Anti-air Tracking Radar (소형 대공 추적레이다용 전원공급기 개발)

  • Kim, Hongrak;Kim, Younjin;Lee, Wonyoung;Woo, Seonkeol;Kim, Gwanghee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.4
    • /
    • pp.119-125
    • /
    • 2022
  • The power supply for the anti-aircraft radar homing sensor should allow the system to receive power quickly and stably without the influence of noise. For this purpose, DC-DC converters are widely used for reliable power conversion. Also, switching of DC-DC converters Frequency noise should not cause false alarms and ghosts that may affect the detection and tracking performance of the system, and it should have a check function that can monitor power in real time while the homing sensor is operating. In order to apply to anti-aircraft radar homing sensor, we developed a multi-output switching power supply with maximum output 𐩒𐩒𐩒 W, efficiency 80% or more (@100% load), output power by receiving 28VDC input, and power supply to achieve more than 80% efficiency. A DC-DC converter was applied to this large output, and the multi-output flyback method was applied to the rest of the low-power output.

A Study on the Usefulness of Development of a Steam Sterilizer Equipped with an Electronic Bowie-Dick Test System

  • Bae, Young Ok;Hwang, Jun Soo;Kim, Sung Il;Lee, Joon Ha
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.156-163
    • /
    • 2017
  • To verify the usefulness of a steam sterilizer equipped with an electronic Bowie-Dick test system, this study was carried out using two methods, utilizing both a steam sterilizer and an electronic Bowie-Dick tester. The first method is to confirm the error detection of the chemical Bowie-Dick test pack and the electronic Bowie-Dick tester in a malfunctioning sterilizer environment. For this purpose, the Bowie-Dick test program for the steam sterilizer was used to test three types of test packs commonly used in hospitals and the electronic Bowie-Dick tester by changing the set values of temperature, time, and vacuum frequency. The second is an experiment to check the sterilizer's normal operation with the electronic Bowie-Dick tester and the usefulness of grasping the cause of the malfunction. The results showed that the sterilization temperature was the same as that of the test pack at a temperature $1{\sim}6^{\circ}C$ lower than the reference temperature of $134^{\circ}C$. In the test with the sterilization exposure time as a variable, there was a normal discoloration at a time difference of 30~90 s. In the experiment using the number of vacuum cycles, the test was correct by performing the normal discoloration only at the normal condition of 3 times. The test results of 30 hospitals were 100 failure tests by a total of 291 Bowie-Dick tests. Of these, the failure factors related to an internal temperature that the chemical test packs could not detect were the greatest, and the four factors related to temperature, including the internal temperature, were found to be 71.18% of total malfunctions. In addition, the Bowie-Dick tester was provided within 30 min after the start of the Bowie-Dick test to confirm the performance of the sterilizer and the detailed cause. A steam sterilizer equipped with an electronic Bowie-Dick test system is used to manage individual sterilizers. In the current steam sterilizer with many temperature-related errors, it is possible to check the malfunction of the temperature difference that the test pack cannot detect, and the cause of error for the sterilizer is immediately detected after the test. The steam sterilizer equipped with the electronic Bowie-Dick test system assists with infection control with accurate sterilizer performance assurance.

Design of a LTCC Front End Module with Power Detecting Function (전력 검출 기능을 포함하는 LTCC 프런트 엔드 모듈 설계)

  • Hwang, Mun-Su;Koo, Jae-Jin;Koo, Ja-Kyung;Lim, Jong-Sik;Ahn, Dal;Yang, Gyu-Yeol;Kim, Jun-Chul;Kim, Dong-Su;Park, Ung-Hee
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.8
    • /
    • pp.844-853
    • /
    • 2008
  • This paper describes the design of a FEM(Front End Module) having power detection function for mobile handset application. The designed FEM consists of a MMIC(Monolithic Microwave Integrated Circuits) power amplifier chip, SAW Tx filter and duplexer, diode power detector and stripline matching circuit. An LTCC(Low Temperature Co-fired Ceramics) technology is adopted for miniaturized FEM. The frequency band is $824{\sim}869$ MHz which is the uplink Tx band of the CDMA mobile system. The size of designed FEM is $7.0{\times}5.5{\times}1.5\;mm^3$, which is an ultra-small size even though the power detector circuit is included. All sub-components of FEM have been developed and measured in advance before being integrated into FEM. The measured output power and gain are 27 dBm and 27 dB, respectively. In addition, the measured ACPR characteristics are 46.59 dBc and 55.5 dBc at 885 kHz and 1.98 MHz offset, respectively.

ICT based Wireless Power Transmission System Development (ICT 기반의 무선전력전송 시스템 개발)

  • Lee, Jong-Hee;Bang, Junho;Chun, Hyun-Jun;Seo, Beom-Geun;Ryu, In-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.67-73
    • /
    • 2016
  • Recently, wireless power transmission has attracted much interest and is the subject of much research in industry and academia. As its name implies, it is a technology which involves transferring power without wires. This paper presents the design of an ICT-based wireless power transmission system. The proposed system consists of a wireless transceiver unit and high-efficiency coil unit, which can increase both the transmission efficiency and the effective power distance. In particular, the wireless transceiver unit was designed to work with the ICT technique to enable real-time remote monitoring. Also, studies were done relating to the effect of reducing the standby power. The optimal frequency of IGBT devices used in industrial wireless power systems of 20[KHz] was utilized. The values of $23.9[{\mu}H]$ and $2.64[{\mu}F]$ were selected for L and C, respectively, through many field experiments designed to optimize the system design. In addition, an output current controlling algorithm was developed for the purpose of reducing the standby power. The results presented in this paper represent a 75[%] to 85[%] higher power transmission efficiency with a 10[%] increase in the effective power transmission distance compared with the existing systems. As a result, the proposed system exhibits a lower standby power and maintenance costs. Also, the designed wireless transceiver unit facilitates fault detection by means of user acquired data with the development of the ICT applied program.

Development of deep learning network based low-quality image enhancement techniques for improving foreign object detection performance (이물 객체 탐지 성능 개선을 위한 딥러닝 네트워크 기반 저품질 영상 개선 기법 개발)

  • Ki-Yeol Eom;Byeong-Seok Min
    • Journal of Internet Computing and Services
    • /
    • v.25 no.1
    • /
    • pp.99-107
    • /
    • 2024
  • Along with economic growth and industrial development, there is an increasing demand for various electronic components and device production of semiconductor, SMT component, and electrical battery products. However, these products may contain foreign substances coming from manufacturing process such as iron, aluminum, plastic and so on, which could lead to serious problems or malfunctioning of the product, and fire on the electric vehicle. To solve these problems, it is necessary to determine whether there are foreign materials inside the product, and may tests have been done by means of non-destructive testing methodology such as ultrasound ot X-ray. Nevertheless, there are technical challenges and limitation in acquiring X-ray images and determining the presence of foreign materials. In particular Small-sized or low-density foreign materials may not be visible even when X-ray equipment is used, and noise can also make it difficult to detect foreign objects. Moreover, in order to meet the manufacturing speed requirement, the x-ray acquisition time should be reduced, which can result in the very low signal- to-noise ratio(SNR) lowering the foreign material detection accuracy. Therefore, in this paper, we propose a five-step approach to overcome the limitations of low resolution, which make it challenging to detect foreign substances. Firstly, global contrast of X-ray images are increased through histogram stretching methodology. Second, to strengthen the high frequency signal and local contrast, we applied local contrast enhancement technique. Third, to improve the edge clearness, Unsharp masking is applied to enhance edges, making objects more visible. Forth, the super-resolution method of the Residual Dense Block (RDB) is used for noise reduction and image enhancement. Last, the Yolov5 algorithm is employed to train and detect foreign objects after learning. Using the proposed method in this study, experimental results show an improvement of more than 10% in performance metrics such as precision compared to low-density images.

Detection and Type-Distribution of Human Papillomavirus in Vulva and Vaginal Abnormal Cytology Lesions and Cancer Tissues from Thai Women

  • Ngamkham, Jarunya;Boonmark, Krittika;Phansri, Thainsang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.1129-1134
    • /
    • 2016
  • Vulva and Vaginal cancers are rare among all gynecological cancers worldwide, including Thailand, and typically affect women in later life. Persistent high risk human papillomavirus (HR-HPV) infection is one of several important causes of cancer development. In this study, we focused on HPV investigation and specific type distribution from Thai women with abnormality lesions and cancers of the vulva and Vaginal. A total of ninety paraffin-embedded samples of vulva and Vaginal abnormalities and cancer cells with histologically confirmed were collected from Thai women, who were diagnosed in 2003-2012 at the National Cancer Institute, Thailand. HPV DNA was detected and genotyped using polymerase chain reaction and enzyme immunoassay with GP5+/bio 6+ consensus specific primers and digoxigenin-labeled specific oligoprobes, respectively. The human ${\beta}$-globin gene was used as an internal control. Overall results represented that HPV frequency was 16/34 (47.1%) and 8/20 (40.0%) samples of vulva with cancer and abnormal cytology lesions, respectively, while, 3/5 (60%) and 16/33 (51.61%) samples of Vaginal cancer and abnormal cytology lesions, respectively, were HPV DNA positive. Single HPV type and multiple HPV type infection could be observed in both type of cancers and abnormal lesion samples in the different histological categorizes. HPV16 was the most frequent type in all cancers and abnormal cytology lesions, whereas HPV 18 was less frequent and could be detected as co-infection with other high risk HPV types. In addition, low risk types such as HPV 6, 11 and 70 could be detected in Vulva cancer and abnormal cytology lesion samples, whereas, all Vaginal cancer samples exhibited only high risk HPV types; HPV 16 and 31. In conclusion, from our results in this study we suggest that women with persistent high risk HPV type infection are at risk of developing vulva and Vaginal cancers and HPV 16 was observed at the highest frequent both of these, similar to the cervical cancer cases. Although the number of samples in this study was limited and might not represent the overall incidence and prevalence in Thai women, but the baseline data are of interest and suggest further study for primary cancer screening and/or developing the efficiency of prophylactic HPV vaccines in Thailand.

Toothpick-Aided Detection of Sclerotinia homoeocarpa in the Turfgrass Leaf Canopy, Thatch, and Soil in Relation to Dollar Spot Infection Centers (이쑤시개를 이용한 잔디층, 대취층, 및 토양층에서 동전마름병 전염원의 검출)

  • Lee, Jung Han;Min, Gyu Young;Shim, Gyu Yul;Kim, Dong Soo;Sang, Hyunkyu;Jung, Geunhwa;Kwak, Youn-Sig
    • Weed & Turfgrass Science
    • /
    • v.4 no.4
    • /
    • pp.376-382
    • /
    • 2015
  • Dollar spot, caused by Sclerotinia homoeocarpa, is the major disease in cool-season turfgrasses. Understanding the distribution of this pathogen in soil and thatch is important to developing disease control strategies. In this study, toothpicks were used to detect S. homoeocarpa in the turfgrass canopy, thatch, and soil at different distances from dollar spot infection centers. The effect of penetrant and contact fungicide applications with different water volumes on distribution of S. homoeocarpa was also investigated. S. homoeocarpa was detected in 100% of samples taken from the leaf canopy, 83.3% in thatch area, and 0% in the soil from within the infection center. S. homoeocarpa was isolated in 100% of samples taken from the edge of the infection center, but was only detected in 13% of the samples taken at 1.5 cm away from the infection center edge. S. homoeocarpa was isolated at a higher frequency in the propiconazole treated plots than those treated with chlorothalonil and was not detected in leaf canopy samples when either fungicides was applied with 6.78 L of water. In conclusion, the toothpick-aided detection technique has improved our understanding of S. homoeocarpa epidemiology and could be used as a diagnostic tool to detect for fungicide resistance on golf courses.