• Title/Summary/Keyword: Co-flow

Search Result 3,423, Processing Time 0.036 seconds

Seismic AVO Analysis, AVO Modeling, AVO Inversion for understanding the gas-hydrate structure (가스 하이드레이트 부존층의 구조파악을 위한 탄성파 AVO 분석 AVO모델링, AVO역산)

  • Kim Gun-Duk;Chung Bu-Heung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.643-646
    • /
    • 2005
  • The gas hydrate exploration using seismic reflection data, the detection of BSR(Bottom Simulating Reflector) on the seismic section is the most important work flow because the BSR have been interpreted as being formed at the base of a gas hydrate zone. Usually, BSR has some dominant qualitative characteristics on seismic section i.e. Wavelet phase reversal compare to sea bottom signal, Parallel layer with sea bottom, Strong amplitude, Masking phenomenon above the BSR, Cross bedding with other geological layer. Even though a BSR can be selected on seismic section with these guidance, it is not enough to conform as being true BSR. Some other available methods for verifying the BSR with reliable analysis quantitatively i.e. Interval velocity analysis, AVO(Amplitude Variation with Offset)analysis etc. Usually, AVO analysis can be divided by three main parts. The first part is AVO analysis, the second is AVO modeling and the last is AVO inversion. AVO analysis is unique method for detecting the free gas zone on seismic section directly. Therefore it can be a kind of useful analysis method for discriminating true BSR, which might arise from an Possion ratio contrast between high velocity layer, partially hydrated sediment and low velocity layer, water saturated gas sediment. During the AVO interpretation, as the AVO response can be changed depend upon the water saturation ratio, it is confused to discriminate the AVO response of gas layer from dry layer. In that case, the AVO modeling is necessary to generate synthetic seismogram comparing with real data. It can be available to make conclusions from correspondence or lack of correspondence between the two seismograms. AVO inversion process is the method for driving a geological model by iterative operation that the result ing synthetic seismogram matches to real data seismogram wi thin some tolerance level. AVO inversion is a topic of current research and for now there is no general consensus on how the process should be done or even whether is valid for standard seismic data. Unfortunately, there are no well log data acquired from gas hydrate exploration area in Korea. Instead of that data, well log data and seismic data acquired from gas sand area located nearby the gas hydrate exploration area is used to AVO analysis, As the results of AVO modeling, type III AVO anomaly confirmed on the gas sand layer. The Castagna's equation constant value for estimating the S-wave velocity are evaluated as A=0.86190, B=-3845.14431 respectively and water saturation ratio is $50\%$. To calculate the reflection coefficient of synthetic seismogram, the Zoeppritz equation is used. For AVO inversion process, the dataset provided by Hampson-Rushell CO. is used.

  • PDF

Comparison of IUHs obtained by the Derived and Simple Equation of GIUH on Third and Fourth-Order Streams (3, 4차 하천에서의 GIUH 유도식과 간략식에 의해 산정된 순간단위도의 비교연구)

  • Joo, Jin-Gul;Ham, Dae-Heon;Jun, Hwan-Don;Lee, Jung-Ho;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.11
    • /
    • pp.1107-1121
    • /
    • 2008
  • The simple equation of GIUH are frequently used in many researches instead of the derived equation of GIUH. However it is still unknown whether the simple equation of GIUH is adaptable for estimating IUHs for basins with various geomorphologic conditions. To verify the applicability of the simple equation of GIUH, in this research, four basins which were Bangrim, Sanganmi, Museong, and Byeongcheon were selected and each basin was assumed as the third and fourth stream order basin according to variable resolutions. After than, IUHs were estimated using the derived and simple equations of GIUH. Eight to sixteen hydrographs were estimated from the each IUH, compared with observed graphs. In case of that the basin is assumed as a third order stream, the derived equation underestimated the peak flows while the simple equation overestimated them. When the basin is assumed as a fourth order stream, the simple equation generally overestimated the peak flows whereas the derived equation produced peak flows good agreement with the observed peak flow. Moreover, the simple equation showed various deviations in accuracy whereas the derived equation produced stable results. Based on the fact found from this research, it can be concluded that the derived equation of GIUH brings better results than the simple equation of GIUH to estimate IUHs for ungauged basins.

Clinical Experience of Continuous Epidural Analgesia Using Baxter $Infusor^{(R)}$ (Baxter $Infusor^{(R)}$를 이용한 경막외 진통제 지속 주입)

  • Bae, Sang-Chull;Lee, Jang-Won;Kim, Ill-Ho;Song, Hoo-Bin;Park, Wook;Kim, Sung-Yell
    • The Korean Journal of Pain
    • /
    • v.4 no.2
    • /
    • pp.127-132
    • /
    • 1991
  • Recently a non-electronic, disposable and portable infusor(Baxter infusor with patient control module, Baxter health care Co., Deerfield IL 60015 USA: BI $\bar{c}$ PCM) has been developed that will deliver both a continuous drug infusion as well as allow the patient to deliver extra doses of medication on a demand basis under predetermined limitation of analgesics. Patients may also not require as high analgesic dose rate to control pain when the acceptable and tolerable level of pain relief can be maintained by this device. From April l99l, we have used a total l93 units of BI $\bar{c}$ PCM. These units consisting of two components which one made by a balloon reservoir(capacity 65 ml, flow rate 0.5 ml/hr) to store medication and to regulate the pump power(490 torr), and another two PCMs to regulate additional analgesic administration by patients demand at intervals of 1S minutes and 60 minutes. The dose administered to the patient can be varied by changing the concentration of the infusate within the balloon reservoir. These devices were utilized for the pain control of 44 patients. These patients were divided into two groups. Twenty seven cases had cancer pain and 17 cases had non-cancer pain. The Touhy needle(No. l8 G.) tip was inserted into the epidural space and was used to guide the catheter to the spinal nerve level corresponding to the most painful area. The device was connected to the opposite site of the catheter tip and was filled with 60 ml of mixture solution such as 0.5% bupivacaine 15 ml, morphine HCl 10 mg, trazodone 10 ml, Tridol 3 ml and normal saline 31 ml were administed as the initial dose. When the initial dose was less effective, the next dose could be varied by increasing the concentration of bupivacaine, by adding more morphine (5~10 mg), and by reducing the volume of normal saline. Using these modules of drug self administration, we experienced the following: 1) Improvement of patient's self titration of analgesic requirement was provided. 2) The patients anxiety with pain recurrence resulting from delays in administering pain control medication was decreased significantly. 3) The working load accompanying with the single bolus injection as the usual method was reduced remarkably. 4) There was urinary retention in 5 cases and pruritus in 4 eases which developed as side effects but respiratory depression and vomiting was not encountered in a single case.

  • PDF

DESIGN AND DEVELOPMENT OF MULTI-PURPOSE CCD CAMERA SYSTEM WITH THERMOELECTRIC COOLING I. HARDWARE (열전냉각방식의 범용 CCD 카메라 시스템 개발 I. 하드웨어)

  • Kang, Y.W.;Byun, Y.I.;Rhee, J.H.;Oh, S.H.;Kim, D.K.
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.4
    • /
    • pp.349-366
    • /
    • 2007
  • We designed and developed a multi-purpose CCD camera system for three kinds of CCDs; KAF-0401E($768{\times}512$), KAF-1602E($1536{\times}1024$), KAF-3200E($2184{\times}1472$) made by KODAK Co.. The system supports fast USB port as well as parallel port for data I/O and control signal. The packing is based on two stage circuit boards for size reduction and contains built-in filter wheel. Basic hardware components include clock pattern circuit, A/D conversion circuit, CCD data flow control circuit, and CCD temperature control unit. The CCD temperature can be controlled with accuracy of approximately $0.4^{\circ}C$ in the max. range of temperature, ${\Delta}33^{\circ}C$. This CCD camera system has with readout noise $6\;e^-$, and system gain $5\;e^-/ADU$. A total of 10 CCD camera systems were produced and our tests show that all of them show passable performance.

Fire Modeling and Smoking Control Characteristic Analysis of Electric Room by Using FDS (FDS를 이용한 전기실의 화재모델링 및 연기제어 특성 분석)

  • Choi, Jeong-A;Lee, Min-Gu;Lee, Dae-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.662-668
    • /
    • 2018
  • Most electric rooms are located in the underground spaces of buildings. When a fire occurs in electrical equipment, the fire expands to cable insulation material, resulting in toxic smoke and combustion products. If the smoke and combustion products quickly move vertically and horizontally, the evacuation of occupants and firefighting activities will be hindered. Therefore, it is necessary to design optimal equipment for smoke control in cases of fires in electric rooms. This study analyzes the characteristics of smoke and combustion products in fires in a cubicle-type switchboard in an electric room using PyroSim, which is based on the program Fire Dynamics Simulator (FDS). The fire modeling consists of four scenarios according to the operation mode of the mechanical ventilation equipment, the amount of air supply and exhaust, and the location of the air supply slot. The analysis shows that the mechanical ventilation equipment improves the smoke density, visibility, carbon monoxide concentration, and temperature characteristics. The visibility and temperature characteristics were improved when the air flow rate and the location of the air supply slot from fire defense regulations were applied.

Assesment of the industrial Wood Waste Disposal Cost through Analysis of the Treatment Flow (사업장계 폐목재의 흐름 분석을 통한 처리비용영향 검토)

  • Kim, Jaenam;Kim, Sujin;Phae, Chaegun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.3
    • /
    • pp.34-40
    • /
    • 2012
  • This research has looked into the treatment process of wood waste generated from industrial waste within the region and in order to modify the problem that may occurred during the mass balance were analyzed for development of suitable solid waste recycling network regionally. As as result, quite amount of wood waste are being transferred to another region, even though a treatment facility's capacity could bear the total amount of waste generated within the area. Although the wood waste could be treated locally, it is analyzed that amount of wood waste are being transferred due to inefficient and irrational processing system between regions. It is assumed that $CO_2$ generated and loss of unnecessary fuel cost from these inefficient system is quite a lot and in order to modify this disorganized system, it will not inevitable to treat the waste based on the characteristics of each regions. Also, the wood waste recycling system should be studied with the efficient, environmental friendly processing and delivering network by minimized transfer distance and local systemizing the waste treatment system.

Effect of EC and pH of Nutrient Solution on the Growth and Quality of Single-Stemmed Rose in Cutted Rose Production Factory (절화장미 수경재배시 배양액의 농도와 pH가 생육과 품질에 미치는 영향)

  • Lee Hye Jin;Yang Eun-Young;Park Keum-Soon;Lee Yong-Beom;Bae Jong Hyang;Jeon Kyung Soo
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.258-265
    • /
    • 2004
  • The experiment was conducted to investigate the effect of EC and pH of nutrient solution on the growth and quality of the single-stemmed rose grown in a rose factory installed with hydroponic system. The growth and quality of the single-stemmed rose were not significantly different from each other with the EC of the nutrient solutions $1.0\~3.5dS{\cdot}m^{-1}$, which resulted in concluding high concentration of the nutrient solution was not necessary. The optimum range of the EC for single-stemmed rose was $1.5\~2.0dS{\cdot}m^{-1}$ considering plant growth, photosynthetic and transpiration rates. The optimum range of the pH for good plant growth without any visible physiological disorder was $4.0\~6.0$. Therefore, to keep the pH of the nutrient solution for rose low compared to other plants was beneficial for plant growth and uptake of the mineral ions.

A Study on Leaching Characteristics Change for Sediment Dredging in Yongwon Channel, Busan New Port (부산신항 용원수로에서의 퇴적물 준설에 의한 용출특성 변화 연구)

  • Choo, Min Ho;Kim, Young Do;Jeong, Weon Mu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.541-547
    • /
    • 2017
  • In Yongwon channel, its natural flow of seawater is blocked by the construction of Busan Newport including the container berth. The channel was transformed into a narrow and long one, where it is possible that ships are only allowed to pass through the north-side channel of Gyeonmado located at the point of river mouth to Songjeongcheon. So it is considered that the changes in the terrain characteristics of Yongwon channel is likely to alter the circulation of sea water, thereby changing its water quality. Contaminants are accumulated from the sediment release. In this study, before and after dredging the sediment release test was performed. As a result, after the sediment dredging is performed, the reduction rate was higher at the same point. The results show that the water quality can be improved by dredging. Each group (A~C) reduction rate of the evaluation of the reduction rate of 4.64% T-N, 18.00%, 18.59%, respectively. T-P rate of 24.75% reduction, 24.17%, 44.08%, respectively. COD reduction rate was 18.57%, 19.76%, 38.08%, respectively. These results can be used as basic data for controlling the contamination by dredging in Yongwon channel.

Establishment of Functional Cells for Vascular Defect Disease from Human Embryonic Stem Cell via Region Sorting Depending on Cell Volume (세포 크기 차이를 이용한 유세포 분석을 통한 인간배아줄기세포 유래 기능성 혈관세포의 확립)

  • Lee, Ji-Hye;Kim, Ju-Mi;Chung, Hyung-Min;Chae, Jung-Il
    • Microbiology and Biotechnology Letters
    • /
    • v.39 no.4
    • /
    • pp.364-373
    • /
    • 2011
  • Human embryonic stem cells have been highlighted as a valuable cellular source in the regenerative medicine field, due to their pluripotency. However, there is the challenge of the establishment of specific functional cell type forms of undifferentiated human embryonic stem cells (hESC). To establish and purify functional cell types from hESCs, we differentiated undifferentiated hESCs into vascular lineage cells and sorted the specific cell population from the whole cell population, depending on their cell volume, and compared them with the non-sorted cell population. We observed that about 10% of the PECAM positive population existed in the VEGF induced differentiating human embryoid body (hEB), and differentiated hEBs were made into single cells for cell transplantation. After making single cells, we performed cell sorting using a fluorescence-activated cell sorter (FACs), according to their cell volume on the basis of FSC region gating, and compared their therapeutic capacity with the non-sorted cell population through cell transplantation into hindlimb ischemic disease model mice. 4 Weeks after cell transplantation, the recovery rate of blood perfusion reached 54% and 17% in the FSC regions of sorted cells- and non-sorted cells, respectively. This result suggests that derivation of a functional cell population from hESCs can be performed through cell sorting on the basis of cell volume after preliminary differentiation induction. This approach may then greatly contribute to overcoming the limitations of marker sorting.

A Study on the Reorganization of the National Spatial Information System (국가공간정보시스템 개편 추진 방향 연구)

  • Kim, Jeong Hyun;Kim, Soon Han;Kim, Sun Kyu;Kim, Sang Min;Jung, Jae Hoon;Heo, Joon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.5
    • /
    • pp.373-383
    • /
    • 2015
  • Spatial information has been widely used for efficient land use and management, disaster management, environment management, infrastructure management, corporate marketing, and cultural assets management, and the need for spatial information is expected to be increased. For this reason, central government, local government and public institutions must establish a National Spatial Information System (Fifteen systems related to spatial information managed by National Spatial Data Infrastructure Policy office, NSIS) framework that guarantees high accuracy and quality. The NSIS will provide convenience usage of spatial information in the field of decision-making or civil support. However the current National Spatial Information System is mainly established with separate processes, which causes data redundancy, deterioration of information, passive opening, and sharing of the spatial data. This study suggests 4 standards, which has been derived by applying value-chain model to NSIS data flow, and they are ‘Production and Establishment’, ‘Integration and Sharing’, ‘Application and Fusion’ and ‘Release and Opening’. Based on these standards, the 15 NSIS were analyzed to draw out implications and reforming directions were suggested. By following these suggestions we expect more recent, consist, accurate, and connected National Spatial Information Service which will be more open to public and then satisfy the demands.